• 제목/요약/키워드: PIV measurements

검색결과 228건 처리시간 0.033초

축류팬의 성능 평가 및 주변 유동 특성 (Performance and Flow Characteristics of Axial Fan)

  • 김재원;정윤영
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.972-981
    • /
    • 2000
  • Comprehensive work is done for flows by an axial fan by experimental research. The present model fan is used for air handling device for out-door unit of an air conditioner in home appliance. PIV(Particle Image Velocimetry) system and wind tunnel are adopted for measurements of flows and performance evaluation, respectively. Major experimental conditions are the installation depth of a fan into a bellmouth of it. Optimal position of a fan in an inlet guide tube is observed by examination of fan-performance and flows in both upstream and downstream of the fan. Consequently, in the case of the fan inserted in half depth into the inlet tube, the efficiency of fan shows its maximum value and flow patterns is also streamlined.

  • PDF

Leakage Flow Influence on SHF pump model performances

  • Dupont, Patrick;Bayeul-Laine, Annie-Claude;Dazin, Antoine;Bois, Gerard;Roussette, Olivier;Si, Qiaorui
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권3호
    • /
    • pp.193-201
    • /
    • 2015
  • This paper deals with the influence of leakage flow existing in SHF pump model on the analysis of internal flow behaviour inside the vane diffuser of the pump model performance using both experiments and calculations. PIV measurements have been performed at different hub to shroud planes inside one diffuser channel passage for a given speed of rotation and various flow rates. For each operating condition, the PIV measurements have been trigged with different angular impeller positions. The performances and the static pressure rise of the diffuser were also measured using a three-hole probe. The numerical simulations were carried out with Star CCM+ 9.06 code (RANS frozen and unsteady calculations). Some results were already presented at the XXth IAHR Symposium for three flowrates for RANS frozen and URANS calculations. In the present paper, comparisons between URANS calculations with and without leakages and experimental results are presented and discussed for these flow rates. The performances of the diffuser obtained by numerical calculations are compared to those obtained by the three-holes probe measurements. The comparisons show the influence of fluid leakages on global performances and a real improvement concerning the efficiency of the diffuser, the pump and the velocity distributions. These results show that leakage is an important parameter that has to be taken into account in order to make improved comparisons between numerical approaches and experiments in such a specific model set up.

Leakage Flow Influence on SHF pump model performances

  • Dupont, Patrick;Bayeul-Laine, Annie-Claude;Dazin, Antoine;Bois, Gerard;Roussette, Olivier;Si, Qiaorui
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권4호
    • /
    • pp.274-282
    • /
    • 2015
  • This paper deals with the influence of leakage flow existing in SHF pump model on the analysis of internal flow behaviour inside the vane diffuser of the pump model performance using both experiments and calculations. PIV measurements have been performed at different hub to shroud planes inside one diffuser channel passage for a given speed of rotation and various flow rates. For each operating condition, the PIV measurements have been trigged with different angular impeller positions. The performances and the static pressure rise of the diffuser were also measured using a three-hole probe. The numerical simulations were carried out with Star CCM+ 9.06 code (RANS frozen and unsteady calculations). Some results were already presented at the XXth IAHR Symposium for three flowrates for RANS frozen and URANS calculations. In the present paper, comparisons between URANS calculations with and without leakages and experimental results are presented and discussed for these flow rates. The performances of the diffuser obtained by numerical calculations are compared to those obtained by the three-holes probe measurements. The comparisons show the influence of fluid leakages on global performances and a real improvement concerning the efficiency of the diffuser, the pump and the velocity distributions. These results show that leakage is an important parameter that has to be taken into account in order to make improved comparisons between numerical approaches and experiments in such a specific model set up.

회전기계용 비접촉식 토크 측정법 성능 평가 (Evaluations on Performances of a Non-Contact Torque Measurement Technique for Rotatory Machinery)

  • 김영환;김영호;조경래;김의간;도덕희
    • 한국수소및신에너지학회논문집
    • /
    • 제29권6호
    • /
    • pp.642-647
    • /
    • 2018
  • Gas compressors are mostly driven by motors. It is important to measure the power of motors to evaluate their power efficiency, because the mechanical loads of gas compressors are always varied. In order to measure the power given to the driving motors, the torque should be measured. Manufacturers of compressors usually use the torque data to calculate the compressors qualities such as power consumption, efficiencies and failures. In general, measurements for the shaft torque of the compressors have been based upon contact types, strain gauges. In the cases of larger compressors, the contact type of strain gauges have several disadvantages such as large size and high cost. In this study, a relatively inexpensive and simple torque sensing technique that is not restricted to shaft diameter is introduced using visualization technique. Particle image velocimetry (PIV) has been adopted to complete non-contact torques measurements for rotating motors. In order to compare the performance of the newly constructed torque measurement technique, torque measurement by a transducer based on MEMS technology has been performed simultaneously during experiments.

생체자연모사 - 갈매기 운동과 유동 동시측정 해석 (Bio Nature Mimic - Simultaneous Measurements of a Seagull Model's Motion and its Flow Fields)

  • 도덕희;백태실;조경래;편용범;조용범
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.117-120
    • /
    • 2006
  • Inspiring or mimicking biological bodies is regarded as one of a breakthrough in the conventional engineering. The bird's motion is one of the mimicking objects. Seagulls fly under strong storm at sea. An attempt of investigating into the characteristics of a seagull model's motion and its flow fields has been made in this study. Three cameras, two for motion capture and one for flow field, were used. The motions of the seagull's wing have been reconstructed, and the flow characteristics around the wing have been investigated with 2D-PIV measurements.

  • PDF

역추진시 단동타 주위 유동특성에 대한 PIV계측 (PIV Measurements of the Flow characteristics around a single rudder in a backward state)

  • 손창배;김옥석;오우준;이창우;이경우
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2010년도 춘계학술대회
    • /
    • pp.383-384
    • /
    • 2010
  • 선박의 제어판은 전진 또는 후진시 조종성능을 결정하는 중요한 요소이다. 본 연구에서는 단동타의 성능평가를 위하여 $Re=2.0\times10^4$ 에서 2-프레임 그레이레벨 상호상관 PIV기법을 이용하여 모텔 주위의 속도장을 계측하였다. 특히 전진시 영각 10도와 20도 사이에서 발생하는 박리영역을 후진시에 나타나는 영향을 평가하였다. 단동타의 형상은 NACA0018을 사용하여 자유유동이 역 방향으로 위치하여 후진시의 효과를 알아본 결과 박리 영역은 전방과 비슷한 영각에서 발생함을 알 수 있었다.

  • PDF

PIV를 이용한 인공심장용 폴리우레탄 인공판막 하류의 유동 측정 : 맥동유동실험 (PIV Measurements of Flow Downstream of Polyurethane Heart Valve Prosthesis for Artificial Heart: Pulsatile Flow Experiment)

  • 유정열;김중경;성재용;장준근;민병구
    • 대한기계학회논문집B
    • /
    • 제26권5호
    • /
    • pp.629-639
    • /
    • 2002
  • In-vitro flow characteristics downstream of a polyurethane artificial heart valve and a Bjork-Shiley Monostrut mechanical valve have been comparatively investigated in pulsatile flow using particle image velocimetry (PIV). With a triggering system and a time-delayed circuit the velocity distributions on the two perpendicular measurement planes downstream of the valves are evaluated at any given instant in conjunction with the opening behaviors of valve leaflets during a cardiac cycle. The regions of stasis and high shear stress can be found simultaneously by examining the entire view of the instantaneous velocity and Reynolds shear stress fields. It is known that high shear stress regions exist at the interface between strong axial jet flows along the wall and vortical flows in the central area distal to the valves. In addition. there are large stagnation or recirculation regions in the vicinity of the valve leaflet, where thrombus formation can be induced by accumulation of blood elements damaged in the high shear stress zones. A correlation between the unsteady flow patterns downstream of the valve and the corresponding opening postures of the polyurethane valve membrane gives useful data necessary for improved design of the frame structure and leaflet geometry of the polyurethane valve.

POD 기법을 이용한 경계층 외부 수직날의 마찰저항 저감 기구에 관한 관측 (Investigation of Skin Friction Reduction Mechanism of Outer-Layer Vertical Blades Using POD Analysis)

  • 안남현;박성현;전호환;이인원
    • 대한기계학회논문집B
    • /
    • 제37권6호
    • /
    • pp.567-575
    • /
    • 2013
  • 외부경계층 수직 날의 마찰저항 저감 기구를 규명하기 위하여 회류수조에서 시간분해 입자영상유속계로 측정된 비정상 유동장에 POD 분석을 실시하였다. 최근의 PIV 결과에서는 수직날 평면 및 수직날 사이 평면에서 각각 2.73%, 7.95%의 마찰저항 저감효과가 발견되었다. 본 연구에서는 수직날 배열이 난류조직구조에 미치는 영향을 POD 방법을 통하여 분석하였다. 난류유동의 조직적인 와구조가 수직날에 의하여 절단, 변형되고 비정상 거동이 난류경계층에서의 마찰저항 저감 기구와 밀접하게 관련된 것으로 관찰되었다.

선체반류 중에서 작동하는 프로펠러에 의한 방향타 유입유동 PIV 계측 (PIV Measurements of Rudder Inflow Induced by Propeller Revolution in Hull Wake)

  • 백부근;김기섭;김경열;김건도;박영하
    • 대한조선학회논문집
    • /
    • 제48권2호
    • /
    • pp.128-133
    • /
    • 2011
  • In the present study, the flow fields in between the propeller and the semi-spade rudder are investigated by using PIV technique to find out the influences of both simulated hull wake and propeller wake on the incident flow to the rudder. The velocity fields are measured at the propeller rotation angle of $180^{\circ}$ and the rudder deflection angles of $0^{\circ}$. Flow fields measured at each rudder deflection angle are analyzed in terms of angle-of-attack against the rudder leading edge. The hull wake increases the angle-of-attack more than that in the uniform inflow condition, forming the angle-of-attack of about $20^{\circ}$ at 0.7R(R=propeller radius) position. The distribution of the angle-of-attack is strongly affected by the stagnation point around the leading edge and camber effect of the rudder. These effects provide asymmetric distribution of angle-of-attack with respect to the leading edge of the rudder.