• 제목/요약/키워드: PIV measurements

검색결과 228건 처리시간 0.034초

CH-OH PLIF와 Stereoscopic PIV동시계측에 의한 난류예혼합화염의 관찰 (Simultaneous Measurements of CH-OH PLIF and Stereoscopic PIV in Turbulent Premixed Flames)

  • 최경민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제29회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.91-96
    • /
    • 2004
  • Simultaneous CH and OH planar laser induced fluorescence(PLIF) and stereoscopic particle image velocimetry (PIV) measurements have been developed to investigate the local flame structure of turbulent premixed flames. The developed simultaneous two radical concentrations and three component velocity measurements on a two-dimensional plane was applied for relatively high Reynolds number turbulent premixed flames in a swirl stabilized combustor. All measurements were conducted for methane-air premixed flames in the corrugated flamelets regime. Strong three-dimensional fluctuation implies that misunderstanding of the flame/turbulent interactions would be caused by the analysis of two-component velocity distribution in a cross section. Furthermore, comparisons of CH-OH PLIF and three-component velocity field show that the burned gases not always have high-speed velocity in relatively high Reynolds number turbulent premixed flame. The Reynolds number dependence of the flame front was clearly captured by the simultaneous CH-OH PLIF and stereoscopic PIV measurements.

  • PDF

PIV 계측과 CFD 해석을 통한 오일펜스 만곡부 단면에서의 유동장 특성 (Characteristics of Flow Field at Curved Section of Oil Fence using PIV Measurements and CFD Simulations)

  • 김태호;장덕종;나선철;배재현;김대안
    • 해양환경안전학회지
    • /
    • 제17권1호
    • /
    • pp.29-37
    • /
    • 2011
  • 유속의 변화에 따른 오일펜스 만곡부 후면의 속도장과 압력장, 와도 및 난류 강도를 계측한 PIV 실험의 결과 유속이 증가함에 따라 유동 경계역의 후면부에서의 흐름 방향이 전면부의 흐름 방향에 가까워지는 현상이 나타났고, 압력 분포의 양상이 달라졌으며 난류도 더욱 불규칙적인 형태로 나타났다. PIV 실험과 동일 조건으로 수행한 CFD 해석 결과, 후류의 유동 패턴이 0.3m/s이하의 저속인 경우는 PIV 실험 결과와 유사하게 나타났으나, 유속이 0.4m/s일 때는 오일펜스 자체의 유연성으로 인해 다소 차이가 나타났고, 오일펜스 하단의 압력차로 인한 불규칙한 난류가 수면까지 영향을 주었다.

마이크로 채널 내부 유동의 Micro-PIV측정과 제반 문제점 (Micro- PIV Measurements of Microchannel Flows and Related Problems)

  • 이상준;김국배
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 마이크로/바이오 가시화기술부문 학술강연회
    • /
    • pp.79-84
    • /
    • 2002
  • Most microfluidic devices such as heat sinks for cooling micro-chips, DNA chip, Lab-On-Chip, and micro pumps etc. have microchannels of various size. Therefore, the design of practical microfluidics demands detail information on flow structure inside the microchannels. However, detail velocity field measurements are rare and difficult to carry out. In addition, as the microfluidics expands, accurate understanding of microscale transport phenomena becomes very important. In this research, micro-PIV system was employed to measure the velocity fields of flow inside a micro-channel. We carried out PIV measurements for several microchannels with varying channels width, inlet and outlet shape, filters, CCD camera and ICCD camera, etc. For effective composition of micro-PIV system, first of all, it is essential to understand optics related with micro-imaging of particles and the particle dynamics encountered in micro-scale channel flows. In addition, it is necessary to find the optimal condition for given experimental environment and? micro-scale flow to be investigated. The problems encountered in measuring velocity field of micro-channel flows are discussed in this paper.

  • PDF

표준화상을 이용한 2차원 PIV와 3차원 PIV계측 및 성능비교검정 (Performance Test of 2-Dimensional PIV and 3-Dimensional PIV using Standard Images)

  • 도덕희;황태규;송주석;백태실;편용범
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.646-651
    • /
    • 2003
  • Quantitative performance test on the conventional 2D-PIV and the hybrid angular 3D-PIV (Stereoscopic PIV) was carried out. LES Data sets on an impinging jet which are provided on the webpage(http://www.vsj.or.jp/piv) for the PIV Standard Project were used for the generation of virtual images. The generated virtual images were used for the 2D-PIV and 3D-PIV measurements. The measurement results showed that the results obtained by 2D-PIV on average values are closer to the LES data than those obtained by 3D-PIV, but the turbulent properties obtained by 2D-PIV are largely underestimated than those obtained by 3D-PIV.

  • PDF

표준영상을 이용한 2차원 PIV와 3차원 PIV 성능시험 (Performance Test on 2-Dimensional PIV and 3-Dimensional PIV Using Standard Images)

  • 황태규;도덕희
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1315-1321
    • /
    • 2004
  • Quantitative performance test on the conventional 2D-PIV and the hybrid angular 3D-PIV(Stereoscopic PIV) was carried out. LES Data sets on an impinging jet which are provided on the webpage(http://www.vsj.or.jp/piv) for the PIV Standard Project were used for the generation of virtual images. The generated virtual images were used for the 2D-PIV and 3D-PIV measurements test. It has been shown that the results obtained by 2D-PIV on average values are slightly closer to the LES data than those obtained by 3D-PIV, but the turbulent properties obtained by 2D-PIV are largely underestimated than those obtained by 3D-PIV.

PIV/OH PLIF 동시측정을 이용한 난류 대향 분출 예혼합화염 구조 연구 (Structure of Turbulent Premixed Opposed Impinging Jet Flame with Simultaneous PIV/OH PLIF Measurements)

  • 조용진;김지호;조태영;윤영빈
    • 한국연소학회지
    • /
    • 제8권1호
    • /
    • pp.36-45
    • /
    • 2003
  • The subject of turbulent premixed flames has been focused by many researchers for a number of decades. Especially, Borghi suggested a magnificent diagram classifying turbulent combustion areas and Lipatnikov and Chomiak modified this diagram. Recently, experimental techniques have been developed so that we can use PIV for measuring 2D velocity field and apply OH PLIF techniques for obtaining flame locations. In present study, a new diagram is proposed using strain rates and OH signal intensity. Thus, simultaneous PIV and OH PLIF measurements are used for shear strain rates and flame locations, respectively. It is believed that the shear strain rates represent flow characteristics such as turbulence intensity and the OH intensity indicates the flame characteristics such as burning velocities.

  • PDF

CH-OH PLIF와 Stereoscopic PIV계측법을 이용한 난류예혼합화염의 관찰 (Simultaneous Measurement of CH-OH PLIF and Stereoscopic PIV in Turbulent Premixed Flames)

  • 최경민
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.102-103
    • /
    • 2004
  • Simultaneous CH and OH planar laser induced fluorescence(PLIF) and stereoscopic particle image velocimetry(PIV) measurements have been developed to investigate the local flame structure of turbulent premixed flames. The developed simultaneous two radical concentrations and three component velocity measurements on a two-dimensional plane was applied for relatively high Renolds number turbulent premixed flames in a swirl stabilized combustor. All measurements were conducted for methane-air premixed flames in the corrugated flamelets regime. Strong three-dimensional fluctuation implies that misunderstanding of the flame/turbulent interactions would be caused by the analysis of two-component velocity distribution in a cross section. Furthermore, comparisons of CH-OH PLIF and three-component velocity field show that the burned gases not always have high-speed velocity in relatively high Renolds number turbulent premixed flame.

  • PDF

Measurements of Temperature and Flow Fields with Sub-Millimeter Spatial Resolution Using Two-Color Laser Induced Fluorescence (LIF) and Micro-Particle Image Velocimetry (PIV)

  • Kim Hyun Jung
    • Journal of Mechanical Science and Technology
    • /
    • 제19권2호
    • /
    • pp.716-727
    • /
    • 2005
  • Comprehensive measurements for velocity and temperature fields have been conducted. A Micro PIV 2-color LIF system have been setup to measure the buoyancy driven fields in a 1-mm heated channel with low Grashof-Prandtl numbers [$86]. Fluorescence microscopy is combined with an MPIV system to obtain enough intensity images and clear pictures from nano-scale fluorescence particles. The spatial resolution of the Micro PIV system is $75{\mu}m\;by\;67{\mu}m$ and error due to Brownian motion is estimated $1.05\%$. Temperature measurements have achieved the $4.7\;{\mu}m$ spatial resolution with relatively large data uncertainties the present experiment. The measurement uncertainties have been decreased down to less than ${\pm}1.0^{\circ}C$ when measurement resolution is equivalent to $76\;{\mu}m$. Measured velocity and temperature fields will be compared with numerical results to examine the feasibility of development as a diagnostic technique.

편광기법을 이용한 수직교차평면의 PIV 속도장 동시측정 (Simultaneous Measurements of Velocity Fields at Two Vertically Crossing Planes by PIV Systems Using Polarization Technique)

  • 김상문;윤상열;권성훈;김경천
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.60-63
    • /
    • 2004
  • A new PIV technique was developed for decreasing optical error which was created during simultaneous measurements of velocity fields at a wall-normal plane and wall-parallel plane by a plane PIV and a Stereoscopic PIV system. The two Nd:Yag laser systems and three CCD cameras were. synchronized to obtain instantaneous velocity fields at the same time. To avoid optical noise at the crossing line by the two laser light sheets, a new optical arrangement using polarization was applied. The obtained velocity fields show the existence of hairpin packet structure vividly and the idealized hairpin vortex signature is confirmed by experiment.

  • PDF