• Title/Summary/Keyword: PIV 측정

Search Result 247, Processing Time 0.027 seconds

Measurement of Flow Field Downstream of Polyurethane Artificial Heart Valve with Floating Valve Leaflet (열림판이 지지대에 고정되지 않은 폴리우레탄 인공판막 하류의 유동장 측정)

  • Kim, J.K.;Sung, J.;Chang, J.K.;Min, B.G.;Yoo, J.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.247-248
    • /
    • 1998
  • The effect of unattached valve leaflet on flow field downstream of a floating and flapping polyurethane heart valve prosthesis was investigated. With a triggering system and a time-delay circuit the instantaneous velocity field downstream of the valve was measured by particle image velocimetry (PIV) in conjunction with the opening posture of a flexible valve leaflet during a cardiac cycle. Reynolds shear stress distribution was calculated from the velocity fields and wall shear stress was directly measured by hot-film anemometry (HFA). The floating motion of the valve leaflet resulted in the reduction of pressure drop and recirculating flow region downstream of the valve.

  • PDF

볼텍스챔버의 유동 특성에 관한 실험

  • Cho, Seok;Seo, Jeong-Sik;Song, Cheol-Hwa;Cheon, Se-Young;Jeong, Mun-Ki
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.590-595
    • /
    • 1998
  • 차세대 원자로(KNGR : Korea Next Generation Reactor)에는 새로운 안전개념으로서 피동형 안전주입탱크(Safety Injection Tank. SIT)의 도입을 고려하고 있는데, 이러한 피동형 유량조절기능은 안전주입탱크내의 유체기구(Fluidic device)인 볼텍스챔버(vortex chamber)에 의해 이루어진다. 볼텍스챔버는 내부에서 발생되는 와류강도에 따라 유동저항의 강도가 달라짐을 이용하여 유량을 피동적으로 조절할 수 있는 유체기구이다. 본 연구에서는 볼텍스챔버의 유동특성을 관찰하기 위하여 소규모 실험장치를 구축하고, 이를 이용하여 실험을 수행하였다. 본 연구는 두 단계로 수행되었다. 제1단계 실험에서는 볼텍스챔버의 기하학적 특성이 안전주입탱크의 안전주입수 방출특성에 미치는 영향에 대한 거시적 관점에서의 연구로서. 볼텍스챔버의 기하학적 변수(유입구 및 방출구의 직경)가 안전주입수의 방출과정에서 발생되는 SIT 내의수위 거동, 안전주입수의 방출유량 특성등에 미치는 영향에 대해 중점적으로 고찰하였다 제2단계 실험에서는 1단계 실험에서 관찰된 안전주입탱크의 여러 가지 방출특성과 볼텍스챔버 내부 유동장의 유동특성과의 관련성을 규명하기 위해 PIV (Particle Image Velocimetry)를 이용하여 볼텍스챔버의 기하학적 변수에 따른 유동장 내부의 국소 유속분포를 측정하였다.

  • PDF

A Study on the Blood Flow Characteristics in the Abodminal Aortic Aneurysm (대동맥류 내부 혈류 유동 특성에 관한 연구)

  • 오태헌;김상욱;이계한
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.5
    • /
    • pp.601-608
    • /
    • 1999
  • 동맥의 일부분의 팽창하는 동맥류는 높은 사망률을 야기하는 혈관계 질환이다. 동맥류의 발생 및 파열에는 동맥류 내부의 혈류의 유동에 의한 혈관벽 전단 응력 및 압력이 주용한 원인 중 하나로 의심되고 있다. 복부대동맥류 내부의 혈류 유동 특성을 밝히기 위해서 동맥류의 최대 확장부가 복부동맥의 1.5배, 2배인 유리 모델을 제작하였다. 정상류 상태에서 다양한 레이놀즈수에 대해서 속도 및 난동도를 입자영상속도계를 이용하여 측정하였다. 경계층 박리로 인한 재순환 부분이 끝나는 재부착점은 동맥류 최대 확장부 후부에서 발생하였으며, 이 위치는 레이놀즈수의 변화에 따라 바뀌었다. 축방향 속도의 난동은 최대 확장부 후부에서 크게 나타났으며, 이 위치에서 난동에 의한 부가적 응력이 크며 혈관벽 구조변화가 발생하리라 예측된다. 동맥류 내부의 압력분포는 수치해석에 의해 계산되었다. 동맥류 내부 압력은 크기가 증가함에 따라 커졌으며 압력은 동맥류 최대 확장부 후부에서 발생하는 재부착점에서 최대값을 나타내었다. 동맥류 최대확장부 후부는 압력이 최대값을 가지며, 전단력의 변화 및 난동이 큰 지역이므로 동맥류의 파열이 발생하기 쉬운 지역으로 예측된다.

  • PDF

Numerical Simulation for Winnowing Failure of Bed Protection (바닥보호공의 흡출 파괴에 대한 수치모의)

  • Ha, Sung Won;Kim, Tae Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.308-308
    • /
    • 2017
  • 국내 하천에 설치된 횡단구조물은 2009년을 기준으로 약 20,753개로 알려져 있으며 수위 유지, 하상고 유지 등의 목적을 가지고 설치된다. 그러나 낙차를 가진 빠른 유속의 흐름을 형성시켜, 하류 하상에서 국소 세굴을 발생시킨다. 이를 방지하기 위해 횡단구조물 하류에 굴요성 구조(flexible structure)인 돌망태, 블록공, 사석 등으로 이루어진 바닥보호공(bed protection)이 설치되나 유실, 침하 등의 문제가 빈번히 발생되고 있어, 문제를 해결하기 위한 연구가 필요하다. 본 연구는 이러한 피복 대책에서 일어날 수 있는 파괴 기구인 전단파괴, 흡출 파괴, 경계 파괴, 하상 형태 변화에 따른 하부 침식 중 흡출 파괴(winnowing failure)를 유발하는 흐름을 검토하기 위한 수치모의를 수행하였다. 이때 흡출 파괴는 바닥보호공의 공극으로 미세한 하상 재료가 난류와 침투류의 작용에 의해 침식되어 바닥보호공이 침하되는 것을 말한다. 수치모의는 전산유체동역학(Computational Fluid Dynamics, CFD) 모형인 FLOW-3D 모형을 이용하였으며, 난류 모형으로 LES 모형을 적용하고 조밀한 격자를 부여하여 바닥보호공의 공극에서 발생되는 비교적 작은 척도의 와(vortex)를 해상할 수 있도록 하였다. 수치모의에 적용된 횡단구조물은 보, 물받이공, 바닥보호공으로 구성하였으며 특히, 바닥보호공의 형상은 구체(sphere)로 가정하여 다층으로 배치하였다. 바닥보호공의 공극 또는 구체 사이에서 발생되는 유속, 압력 등의 흐름특성을 분석한 결과, 바닥보호공 두께가 두꺼울수록 흡출 파괴에 대해 안정적인 것으로 나타났다. 이는 바닥보호공 설계를 위한 기초자료로 활용될 수 있으며, 향후 입자영상유속계(Particle Image Velocimeter, PIV)와 같이 공극에서 흐름을 측정할 수 있는 방법과 병행한 연구를 수행할 수 있을 것이다.

  • PDF

Heat transfer and flow characteristics of sweeping jet issued from rectangular nozzle with thin plate (박판이 부착된 사각노즐에서 분사되는 Sweeping jet의 유동 및 열전달 특성)

  • Kim, Donguk;Jung, Jae Hoon;Seo, Hyunduk;Kim, Hyun Dong;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.2
    • /
    • pp.58-66
    • /
    • 2019
  • This study investigated heat transfer and flow characteristics of a sweeping jet issued from a rectangular nozzle with a thin plate. A thin vertical aluminum plate was attached on outlet of fluidic oscillator to increase velocity of central area with Coanda effect and enhance heat transfer performance. From visualization and PIV experiments, sweeping jet with a thin plate has larger velocity distribution in center region than that of the normal sweeping jet while oscillating frequency is similar as the normal one. Thermographic phosphor thermometry method was used to visualize the temperature field and Nu distribution of plate with impinging sweeping jet with thin plate. Four Reynolds numbers and three jet-to-wall distances were selected as parameters. It is found that heat transfer performance in the low jet-to-wall spacing was enhanced as the cooled area was expanded. However, when the jet-to-wall spacing became greater than 8dh, heat transfer performance became similar due to reduced impinging velocity.

Uniformity of Temperature in Cold Storage Using CFD Simulation (CFD 시뮬레이션을 이용한 농산물 저온저장고내의 온도분포 균일화 연구)

  • Jeong, Hoon;Kwon, Jin-Kyung;Yun, Hong-Sun;Lee, Won-Ok;Kim, Young-Keun;Lee, Hyun-Dong
    • Food Science and Preservation
    • /
    • v.17 no.1
    • /
    • pp.16-22
    • /
    • 2010
  • To maintain the storage quality of agricultural products, temperature uniformity during cold storage, which is affected by fan flow rate and product arrangement, is important. We simulated and validated a CFD (Computational Fluid Dynamics) model that can predict both airflow and temperature distribution in a cold storage environment. Computations were based on a commercial code (FLUENT 6.2) and two turbulence models. The standard k-$\varepsilon$ model and the Reynolds stress model (RSM) were chosen to improve the accuracy of CFD prediction. To obtain comparative data, the temperature distribution and velocity vector profiles were measured in a full-scale cold storage facility and in a 1/5 scale model. The agricultural products domain in cold storage was modeled as porous for economical computation. The RSM prediction showed good agreement with experimental data. In addition, temperature distribution was simulated in the cold storage rooms to estimate the uniformity of temperature distribution using the validated model.

Study of Acoustic Streaming at Resonance by Longitudinal Ultrasonic Vibration Using Particle Imaging Velocimetry (입자 영상 유속계를 이용한 초음파 수직진동에 의해 유도된 공진상태에서의 음향유동에 관한 연구)

  • 노병국;이동렬
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.5
    • /
    • pp.340-352
    • /
    • 2004
  • Acoustic streaming induced by the microscopic longitudinal ultrasonic vibration at 28.5 ㎑ is visualized between the quiescent glass plate and ultrasonic vibrator by particle imaging velocimetry(PIV) using laser. To investigate the augmentation of air flow velocity of acoustic streaming. the velocity variations of air streaming between the stationary plate and ultrasonic vibrator are measured in real-time. It is experimentally investigated that the magnitude of the acoustic streaming dependent upon the gap between the ultrasonic vibrator and stationary p1ate results in the variations of the average velocity fields as a outcome of the bulk air flow caused by the ultrasonic vibration. In addition. maximum acoustic streaming velocity exists at resonant gap. 18mm that is one of the resonant gaps (H=18, 24, 30, 36㎜) at which resonance occurs. The variation of the local maximum turbulent intensity with axial direction appear to reveal the value of 8%∼70% dependent upon the gap between the quiescent glass plate and ultrasonic vibrator. Shearstress is also maximized at the center region of the vibrator and the vorticity is also maximum and minimum in the neighborhood of the center of the vibrator at which the local maximum turbulent intensity and shear stress exist.

The Change of Flow Characteristics in Lateral Aneurysm Models for Different Coil Locations (코일 위치에 따른 측방 동맥류 내부 혈류 유동의 변화)

  • 이계한;송계웅;변홍식
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.375-383
    • /
    • 2002
  • Aneurysm embolisation method using coils have been widely used. Micro coils are introduced via a small catheter, and are packed inside of aneurysm sac, which induces intraaneurysmal flow stagnation and thrombus formation. When partial blocking of an aneurysm is inevitable, the location of coils is important since it changes the flow patterns inside the aneurysm, which affect the embolisation process. We measured the flow field inside the partially blocked lateral aneurysm models in vitro, and tried to suggest the effective locations of coils for aneurysm embolisation. Velocity fields are measured using a particle image velocitimeter for different coil locations- proximal neck, distal neck, proximal dome and distal dome. Flow into the aneurysm sac was significantly reduced in the distally blocked models, and coils at distal neck blocked inflow more effectively comparing to those at distal dome. This study suggests that distal neck should be the most effective location for aneurysm embolisation.

Hospital-Acquired Measles: A Systematic Review Using the Outbreak Reports and Intervention Studies of Nosocomial Infection (ORION) Statement

  • Erdenetuya Bolormaa;Cho Ryok Kang;Han Ho Kim;Young June Choe
    • Pediatric Infection and Vaccine
    • /
    • v.31 no.1
    • /
    • pp.64-74
    • /
    • 2024
  • Purpose: Despite the recent increased number of nosocomial measles, the outbreak investigation reports are not usually standardized, thus posing unclear understanding of magnitude of its public health burden. We used the Outbreak Reports and Intervention Studies of Nosocomial Infection (ORION) statement, to compare nosocomial outbreaks and synthesize evidence to prevent hospital transmission of measles. Methods: A PubMed, Web of Science, Embase, Scopus, and Cochrane search in English, using the medical subject headings "measles," "nosocomial," "hospital," and "healthcare," was performed. We evaluated the quality of outbreak reports of nosocomial measles infection worldwide using the ORION statement findings and recommendations. Results: We reviewed 24 studies in accordance to the ORION statement. Measles transmission in healthcare settings is a significant burden on the morbidity, mortality, and economy of measles. The healthcare workers' booster vaccination guidelines should be monitored and enhanced during the post-elimination period of measles. The outcomes of infections must be explicit for outbreak reports. Conclusions: This study identified the epidemiological and clinical characteristics of nosocomial measles infections and provided strong evidence for infection control policies in hospitals.

The Flow Control by a Horizontal Splitter Plate for a Square Prism near a Wall (벽면에 근처에 놓인 정방형주의 수평 분리판에 의한 유동 제어)

  • Ro, Ki-Deok;Lee, Sang-Jun;Lee, Gyeong-Yun;Jang, Jae-Dong;Jung, Yong-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.625-631
    • /
    • 2011
  • The passive control of fluid force acting on a square prism near a plane wall was studied by attaching horizontal splitter plate on the corner of the prism. The width of the splitter plate was 10% of the square width. The experiments were performed by measuring of fluid force on the prism and by visualization of the flow field using PIV. The experimental parameters were the attaching position and the space ratios G/B between the prism and wall. The flow between the prism and wall was remarkable and Karman vortex in the wake of the prism was considerable in the space ratio over 0.4. The point of inflection of average lift coefficient and Strouhal number on the prism were represented at the space ratio G/B=0.4 for the prototype prism and G/B=0.6 for the prism having horizontal splitter plate. The drag of the prism was reduced average 4.5% with the space ratios by attaching the horizontal splitter plate at the rear and lower corner on the prism. In this case, the size of the separated region on the upside of the prism was smaller than that of prism without the splitter plate.