• 제목/요약/키워드: PFM

검색결과 250건 처리시간 0.028초

부하 환류모드를 제공하는 새로운 반 브리지 인버터의 손실해석 (Loss analysis for the novel half bridge inverter with load free-wheeling mode)

  • 연재을;조규민;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.216-219
    • /
    • 2003
  • The resonant inverter is widely used for induction heating, electronic ballast and supersonic motor driving circuit. In the meantime, control techniques of PWM, PFM etc.. are mainly applied to control the output power of the resonant inverter. But, in the case of using the half bridge resonant inverter, it is difficult to control the output power by PWM, because its main circuit does not provide the load free-wheeling mode. Therefore, PAM or PFM was usually applied to control output power of half bridge resonant inverter. However, PAM needs a variable DC voltage source, which makes the system structure more complex. On the other hand, in case of PFM, efficiency is declined by operation with poor power factor. This paper Proposed the novel half bridge resonant inverter which can provide the load free-wheeling mode. Also its analysis results for PWM operation with unity fundamental power factor are Presented and compared with other resonant inverters using PWM and PFM.

  • PDF

과학기술위성 2호 준비행모델 환경시험 결과 (STSAT-2 PFM Environmental Test Result)

  • 이승헌;박종오;심은섭;이승우;서정기;장태성;이상현;김성현
    • 항공우주기술
    • /
    • 제6권1호
    • /
    • pp.55-63
    • /
    • 2007
  • 과학기술위성 2호는 국내에서 최초로 개발되는 소형위성발사체(KSLV-1)에 의하여 국내 발사장(나로 우주센터)에서 발사될 위성이다. 2002년 개발을 시작하여 엔지니어링모델(EM), 준비행모델(PFM), 비행모델(FM)을 개발 완료하였다. 위성의 기능을 점검하기 위해 종합적인 전기/전자 기능시험과 우주환경시험, 발사환경시험을 수행한다. 본 논문은 성공적으로 수행한 과학기술위성 2호 준비행모델의 우주환경시험과 발사환경시험에 대한 분석과 그 결과를 보고한다.

  • PDF

The Development and Evaluation of an Incontinence Intervention Program for the Elderly Women at Elderly Welfare Center

  • Kim Jeungim
    • 대한간호학회지
    • /
    • 제34권8호
    • /
    • pp.1427-1433
    • /
    • 2004
  • Purpose. The elderly with UI experienced urine leakage for a long time. The prevalence of UI has increased and it makes costly. Particularly, the elderly were reluctant to visit a hospital or a clinic for the reasons of modesty and poverty. To solve this problem, incontinence intervention programs should be provided at the elderly welfare center. The purpose of this research was to develop Incontinence Intervention Program for the Elderly Women (IIPE) and evaluate in its effect. Methods. The study design was quasi-experimental with pre and post-test. The study was performed for ten weeks at one elderly welfare center, Seoul, Korea. The subjects were gathered through an official announcement and informed consent was obtained. IIPE, in this study, was consisted of diagnosis, education, exercise and evaluation. The study variables were PFM exercise adherence, pelvic muscle strength, Continence self-efficacy, geriatric depression and incontinence stress. The effects of the IIPE on PFM exercise adherence, pelvic muscle strength, Continence self-efficacy, geriatric depression and incontinence stress were also evaluated. Results. The mean age of the subjects was 75.2 years. The average attendance was 6.2 times. The IIPE improved PFM exercise adherence, intra-vaginal contraction power and CSE significantly. But it was not significant in incontinence stress and geriatric depression. Other important results were that the two-finger test and urine stream interruption were more useful for elderly women with rigid vaginas in teaching and evaluating. Conclusion. The Findings suggest that IIPE is effective to the community-residing elderly. Further investigation is needed on a long-term basis with control group.

Fracture resistance and marginal fit of the zirconia crowns with varied occlusal thickness

  • Tekin, Yadel Hazir;Hayran, Yeliz
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.283-290
    • /
    • 2020
  • PURPOSE. The present study aimed to evaluate the clinical applicability of monolithic zirconia (MZ) crowns of different thickness via determination of fracture resistance and marginal fit. MATERIALS AND METHODS. MZ crowns with 0.5, 0.8, 1.0, and 1.5 mm thickness and porcelain fused to metal (PFM) crowns were prepared, ten crowns in each group. Marginal gaps of the crowns were measured. All crowns were aged with thermal cycling (5 - 55℃/10000 cycle) and chewing simulator (50 N/1 Hz/lateral movement: 2 mm, mouth opening: 2 mm/240000 cycles). After aging, fracture resistance of crowns was determined. Statistical analysis was performed with one-way ANOVA and Tukey's HDS post hoc test. RESULTS. Fracture loads were higher in the PFM and 1 mm MZ crowns compared to 0.5 mm and 0.8 mm crowns. 1.5 mm MZ crowns were not broken even with the highest force applied (10 kN). All marginal gap values were below 86 ㎛ even in the PFM crowns, and PFM crowns had a higher marginal gap than the MZ crowns. CONCLUSION. The monolithic zirconia exhibited high fracture resistance and good marginal fit even with the 0.5 mm thickness, which might be used with reduced occlusal thickness and be beneficial in challengingly narrow interocclusal space.

고주파 결합 인덕터 직렬 공진형 ZCS-PFM 초퍼 제어 방식을 이용한 새로운 승압형 DC-DC 컨버터 (A Novel Boost DC-DC Converter using High Frequency Coupled Inductor Series Resonant ZCS-PFM Chopper Control Method)

  • 김홍신;허영환;문상필;박한석
    • 전기학회논문지P
    • /
    • 제66권2호
    • /
    • pp.63-68
    • /
    • 2017
  • This paper proposes a new non-isolated DC conversion circuit topology of the voltage source coupled inductor series resonant high-frequency PFM controlled boost chopper type DC-DC power converter using two in one IGBT power module, which can efficiently operate under a principle of zero current soft switching for wide output regulation voltage setting ranges and wide fluctuation of the input DC side voltage as well as the load variation ranges. Its steady state operating principle and the output voltage regulation characteristics in the open-loop-based output voltage control scheme without PI controller loop are described and evaluated from theoretical and experimented viewpoints. Finally, in this paper the computer-aided simulation steady-state analysis and the experimental results are presented in order to prove the effectiveness and the validity of voltage regulation characteristics of the proposed series resonant zero current soft switching boost chopper type DC-DC power converter circuit using IGBTs which is based on simple pulse frequency modulation strategy more than, 20kHz.

3중 모드 DC-DC 벅 변환기 설계 (Design of a Tripple-Mode DC-DC Buck Converter)

  • 유성목;박준호;박종태;유종근
    • 전기전자학회논문지
    • /
    • 제15권2호
    • /
    • pp.134-142
    • /
    • 2011
  • 본 논문에서는 3중 모드 고효율 DC-DC 벅 변환기를 설계하였다. 설계된 벅 변환기는 부하 전류가 큰 경우(100mA~500mA)에는 PWM(Pulse Width Modulation) 제어 방식을 사용하고, 부하 전류가 작은 경우(1mA~100mA)에는 PFM(Pulse Frequency Modulation) 제어 방식을 사용하며, 부하 전류가 1mA 이하인 대기모드(sleep mode)에서는 LDO(Low Drop Out)를 사용한다. 또한, PFM 모드에서 부하 전류가 작은 경우 효율을 증가시키기 위해 DPSS(Dynamic Partial Shutdown Strategy) 기법을 사용하였다. 그 결과 설계된 변환기는 넓은 부하 전류 범위에서 높은 효율을 얻을 수 있다. 제안된 벅 변환기는 CMOS 0.18um공정을 이용하여 설계되었다. 최대 효율은 96.4% 이고, 최대 부하 전류는 500mA이다. 입력과 출력 전압은 각각 3.3V와 2.5V이며, 칩 크기는 PAD를 포함하여 1.15mm ${\times}$ 1.10mm이다.

요통유무에 따른 복부 드로우인과 골반바닥근 수축훈련이 배가로근과 골반바닥근에 미치는 영향 (The effect of abdominal drawing-in maneuver and pelvic floor muscle contraction in individuals with and without low back pain)

  • 윤혜진;김지선
    • 대한물리의학회지
    • /
    • 제11권1호
    • /
    • pp.53-60
    • /
    • 2016
  • PURPOSE: This study aimed to identify differences in the thickness of the transverse abdominis (TrA) and pelvic floor muscles (PFM) between those with (LBP) and without low back pain (non-LBP). The standardized methods of contraction for the TrA and PFM were used to perform the abdominal draw-in maneuver (ADIM) and pelvic floor muscle contraction (PFC), respectively. METHODS: This study included 27 young men and women, who were verbally instructed regarding the maneuvers (LBP, n=14; non-LBP, n=13). For all subjects, TrA and PFM thickness were evaluated by ultrasonography during ADIM and PFC. RESULTS: The results of this study showed that TrA thickness increased during ADIM and PFC to a greater degree in the non-LBP group than in the LBP group (p < 0.01). PFM thickness increased more during PFC in the non-LBP group than in the LBP group (p < 0.05). Both groups showed greater increases in TrA thickness during ADIM than during PFC (p < 0.01), and greater increases in PFM thickness during PFC than during ADIM (p < 0.05). CONCLUSION: These results suggest that receiving verbal instructions on how to use each muscle for a specific maneuver was more beneficial than other verbal instruction. Further studies are needed determine how our results may be applied beneficially in research on this topic.

삼중수소를 이용한 지하수 연령측정 방법에 관한 연구 (A Study on Groundwater Age Dating Methods Using Tritium)

  • 오진석;김선준
    • 대한지하수환경학회지
    • /
    • 제2권2호
    • /
    • pp.49-57
    • /
    • 1995
  • 지하수에 대한삼중수소농도의 측정치가 발표된 충청남도 청양, 제주도 지역 및 미국 조지아지역에 대해 평균체제시간을 계산하는 지하수연령측정 모델인 PFM, CMM, DBM과 평균체제시간과 분산매개변수를 동시에 계산하는 DNM, DM( $C_{FF}$ )모델을 적용하여 그 결과를 비교하였다. 입력자료인 강우의 삼중수소 농도의 부족한 측정자료를 보완하기 위하여 한국의 포항, 카나다의 오타와지역의 강수자료를 이용하여 입력함수를 작성하였다. 내재적으로 적은 분산을 가정하는 PFM과 DBM모델에 의한 결과는 유사하게 계산되었으며, 동일한 지역에서도 특이하게 높은 농도를 보이는 지점은 CMM에 의한 계산이 되지 않았다. 평균체제시간과 분산매개변수가 동시에 계산된 DNM과 DM( $C_{FF}$ )모델의 결과는 PFM, CMM, DBM의 결과를 이용하여 매개변수값을 한정시켰다. 동일지역에서도 삼중수소농도의 변화가 큰 경우는 각 지점마다 특징적인 지하수유동특성을 보이는 것으로 판단되어, 전 지 역에 걸쳐 동일한 모델을 일률적으로 적용하는 것은 바람직하지 않은 것으로 사료된다.

  • PDF

새로운 주파수 가변형(PFM) 직렬 부스트 캐패시터(SBC) 풀 브리지 DC/DC 컨버터 (A New Pulse Frequency Modulation(PFM) Series Boost Capacitor(SBC) Full Bridge DC/DC Converter)

  • 신용생;장영수;노정욱;홍성수;이효범;한상규
    • 전력전자학회논문지
    • /
    • 제14권2호
    • /
    • pp.120-127
    • /
    • 2009
  • 본 논문에서는 고효율 및 고전력밀도의 새로운 주파수 가변형(PFM) 직렬 부스트 캐패시터(SBC) 풀 브리지 DC/DC 컨버터를 제안한다. 제안된 회로는 기존 위상천이 풀 브리지 컨버터와 달리 스위칭 주파수에 따라 직렬 부스트 캐패시터의 전압을 가변하여 출력전압을 제어하는 방식으로, 50% 고정 시비율로 구동되므로 환류구간이 존재하지 않아 도통손실이 작다. 또한 넓은 부하 영역에 대해 영전압 스위칭 동작이 보장되며, 출력 인덕터 전류 리플도 매우 작아 출력 인덕터의 사이즈를 줄일 수 있어 대전류 사양에 매우 적합한 장점을 갖는다. 본 논문에서는 제안된 회로의 이론적 해석 및 PSIM Simulation을 수행하며, 이를 실제로 1.2kW급(12V, 100A) 서버용 컴퓨터 전원장치의 프로토 타입 제작을 통한 실험결과로부터 제안된 회로의 동작특성과 타당성을 검증한다.

팔꿉관절 가쪽위관절 통증 환자에서 근위방향 기능적 마사지를 이용한 노쪽 손목 폄근 신장운동이 통증과 근력에 미치는 효과 (Effects of Stretching Extensor Carpi Radialis With Proximal Functional Massage on Pain and Strength in Patients With Lateral Epicondylalgia)

  • 정성대;하성민;김수정;박규남;권오윤
    • 한국전문물리치료학회지
    • /
    • 제19권1호
    • /
    • pp.66-75
    • /
    • 2012
  • The purpose of this study was to identify the effects of two types of stretching extensor carpi radialis on the visual analog scale (VAS), pressure-pain thresholds (PPTs), grip strength (GS), and strength of wrist extensor (SWE) in patients with lateral epicondylalgia. Sixteen patients with lateral epicondylalgia were recruited for this study and randomly assigned to two groups; the conventional stretching group (CS) and the stretching of proximal functional massage group (PFM); the VAS, PPTs, GS, and SWE were measured before and after the intervention. Over a period of stretching exercises were performed for five minutes per day, five days per week. The paired t-test and Wilcoxon signed-rank test were used to determine the statistical differences in the VAS, PPTs, GS, and SWE (pre- and post-test). The Independent t-test and Mann-Whitney U test were used to compare the effects of stretching exercises between the CS and PFM groups. The results of this study demonstrated that in the PFM group, the PPTs, GS, and SWE significantly increased, and the VAS decreased (p<.05). In the CS group, the VAS and GS increased significantly after the three-week intervention (p<.05). Pain was decreased and strength (GS and SWE) was increased in the PFM group, compared to the CS group (p<.05). The findings of this study indicate that PFM technique can be applied for decreasing pain and increasing the GS and SWE in patients with lateral epicondylalgia.