Comparison of PET image quality using simultaneous PET/MR by attenuation correction with various MR pulse sequences

  • Park, Chan Rok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1610-1615
    • /
    • 2019
  • Positron emission tomography (PET)/magnetic resonance (MR) scanning has the advantage of less additional exposure to radiation than does PET/computed tomography (CT). In particular, MR based attenuation correction (MR AC) can greatly affect the image quality of PET and is frequently obtained using various MR sequences. Thus, the purpose of the current study was to quantitatively compare the image quality between MR non-AC (MR NAC) and MR AC in PET images with three MR sequences. Percent image uniformity (PIU), percent contrast recovery (PCR), and percent background variability (PBV) were estimated to evaluate the quality of PET images with MR AC. Based on the results of PIU, 15.2% increase in the average quality was observed for PET images with MR AC than for PET images with MR NAC. In addition, 28.6% and 71.1% improvement in the average results of PCR and PBV respectively, was observed for PET images with MR AC compared with that with MR NAC. Moreover, no significant difference was observed among the average values using three MR sequences. In conclusion, the current study demonstrated that PET with MR AC improved the image quality and can be help diagnosis in all MR sequence cases.

$^{18}F$-FDG PET 영상의 정량적 비교: PET/MR VS PET/CT (Quantitative Comparisons in $^{18}F$-FDG PET Images: PET/MR VS PET/CT)

  • 이무석;임영현;김재환;최규오
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.68-80
    • /
    • 2012
  • 감쇠 보정법과 산란 보정법은 정량적인 PET검사를 하기 위한 필수적인 방법이다. PET/CT에서는 PET에서 사용하는 소멸방사선과 CT의 X선이 같은 전리 방사선이기 때문에 측정에 의한 CT의 Hounsfield Units를 감쇠 계수로 전환해서 감쇠보정, 산란보정이 가능하다. 그러나 PET/MR에서 MR는 강한 자기장을 걸어 수소밀도와 조직의 이완률차이로 되돌아오는 변화로 신호를 획득하기 때문에 CT처럼 전환하는 것은 불가능하다. Ingenuity TF PET/MR장비는 soft tissue, lung, air로 3구역을 segment하여 MR 감쇠지도를 얻는다. 이에 신호획득원리가 완전히 상이한 PET/MR과 PET/CT에 대한 정량적 평가를 하고자 한다. Phantom study로 uniform cylinder phantom에 증류수 9293 ml와 $^{18}F$-FDG 199.8 MBq를 넣고 magnetic stirrer를 이용하여 균일하게 교반한 후 60 min부터 15분 간격으로 Ingenuity TF PET/MR, Gemini TF 64, Biograph Truepoint 40를 이용하여 각각 single-bed로 2 min씩으로 영상을 얻었다. phantom의 중심부분 10개의 slice에 대한 동일한 관심영역을 그려 SUVs를 측정하고 평균, 표준편차를 구하였다. 그리고 임상적용을 위한 평가로 $^{18}F$-FDG 섭취가 정상인 환자를 대상으로 90 sec/bed씩 Ingenuity TF PET/MR을 시행한 후 Gemini TF 64 PET/CT 검사를 실시하였다. 각각의 data에서 lung, liver, spleen, bone 위치에 동일한 관심영역을 그려 SUVs 최대값과 평균값을 측정하고, %Difference를 구하였다. 또한, PET 장비들 사이에서의 일치도를 평가하기 위해 Bland-Altman plot 분석을 하였다. Phantom study에서 3가지 장비에서 측정한 SUVs 최대값과 평균값은 Biograph Truepoint 40, Gemini TF 64, Ingenuity TF PET/MR 순으로 높은 것을 확인할 수 있었다. patients study에서는 MR과 CT로 감쇠 보정한 PET장비의 SUVs 최대값과 평균값이 서로 유의미한 차이가 없었다.(p<0.05) Lung에서 left middle lobe과 transverse bone을 제외하고는 MR로 감쇠 보정한 PET의 SUVs가 대체로 낮았다. Bland Altman Plot으로 분석한 결과 대부분의 항목에서 95% 신뢰구간의 일치한계선내에서 측정되었다. PET/CT에서는 time of flight 기능을 가진 PET이 SUVs가 낮게 측정되었다. PET/MR과 PET/CT에서 알아본 SUVs차이는 MR을 이용한 분할 감쇠 보정방법이 CT를 사용한 측정 감쇠보정방법보다 SUVs가 낮게 측정되었다. 이러한 다른 감쇠 보정법에 의한 SUVs의 차이는 임상적으로는 용인할 수준에 있었지만, 향후 PET/MR와 PET/CT의 정량적인 값을 비교 분석할 때 PET 장비들간의 특성은 고려할 필요가 있다.

  • PDF

대장-직장암의 간전이에서 FDG PET과 MR의 진단 성능 (Diagnostic Accuracy of PET and MR for Detecting Liver Metastasis from Colorectal Cancer)

  • 박은경;강원준;어재선;이동수;정준기;이명철
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권5호
    • /
    • pp.249-256
    • /
    • 2006
  • 목적: 대장-직장암에서 간전이 여부를 진단하기 위한 영상 검사 방법으로 기존에는 CT 촬영을 시행하여 왔다. 최근에는 MR 및 FDG PET을 간전이 진단에 적극적으로 활용하고 있는 추세이다. 이에 이 연구에서는 대장-직장암 환자에서 간전이에 대한 FDG PET의 진단적 가치를 MR과 비교하여 보고자 하였다. 대상 및 방법 대장: 직장암으로 확진된 환자들 중에 간전이를 진단 또는 배제하기 위하여 CT 이외에도 MR 및 F-18-FDG PET (conventional PET 및 fusion PET)을 모두 시행한 환자는 26명이었다. 이 연구에서는 26명의 환자들에게서 영상화 된 35개의 병변을 분석의 대상으로 삼고, FDG PET과 MR의 민감도 및 특이도를 간분엽절제술 및 종양절제술을 통해 얻어진 병리소견 및 임상소견 또는 추적 영상 소견을 표준으로 하여 각각 구하였다. FDG PET과 MR은 평균 7일 간격으로 시행되었으며, 두 검사 사이에 치료적 요법을 시행 받은 환자는 한 명도 없었다. 결과: 병리 결과, 35개의 병변 중에서 18개(51.4%)의 병변은 간전이로 판명되었으며, 나머지 17개(48.6%)는 낭종, 지방, 혈관종, 농양, 호산구성농양 등의 양성 병변으로 판명되었다. 35개의 병변 중 MR과 FDG PET의 진단이 일치한 병변은 간전이 17개(94.4%)와 양성 병변 13개(76.5%)로 전체적으로는 85.7%의 일치도를 보였다. FDG PET의 민감도는 94.4% (17/18), 특이도는 94.1% (16/17)였으며 MR의 민감도는 100% (18/18), 특이도는 82.4% (14/17)이었다. MR에서 위양성을 보였던 3개의 병변은 낭종과 호산구성농양이었고, FDG PET에서 위음성을 보였던 1개의 병변은 직경 8 mm의 작은 병변이었다. 직경 10 mm 이하인 병변들만 분석했을 때, 총 20개의 병변에 대하여 FDG PET은 민감도 85.7%(6/7), 특이도 92.3%(12/13), MR은 민감도 100%(7/7), 특이도 76.9%(10/13)를 보였다. 그 외에도 간전이 병변의 평균 maxSUV는 $6.7{\pm}3.8$로 간전이와 양성병변을 최적으로 감별할 수 있는 maxSUV의 cutoff value는 3.1 이었다. (AUC=0.897, p<0.001, 민감도 83.3%, 특이도 94.1%) 결론: FDG PET은 간전이를 진단하는데 MR과 대등한 민감도와 특이도를 보였다. 통계적으로 유의한 차이를 보이지는 않았지만 간전이에 대한 FDG PET의 음성예측도는 MR보다 높았으며, 직경 10 mm 미만의 작은 병변에 대해서도 FDG PET은 우수한 성적을 보였다. 향후 대장암의 간전이 진단에 FDG PET이 유용하게 이용될 것이다.

PET/CT 검사에 있어서 MR Torso Coil의 CT 감쇄보정에 대한 영향 평가 (The Effects of a MR Torso Coil on CT Attenuation Correction for PET)

  • 이승재;반영각;오신현;강천구;임한상;김재삼;이창호;서수현;박용성
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.81-86
    • /
    • 2012
  • PET과 융합된 MR 영상에서 MR coil은 PET 영상용 감쇄보정에 있어서 위치 정보 수집에 관한 오류를 극복하기 위한 노력이 시도 되어 왔다. 본원에서는 이런 문제점을 보완한 Three modality system (PET/CT +MR)을 이용하고 있다. 이 논문에서는 MR torso coil이 CT 감쇄보정에 미치는 영향을 평가하였다. MR torso coil을 장착하고 CT로 감쇄보정한 PET 영상에서 인공물에 대한 평가를 하였다. 균일도 평가용 팬텀과 1994 NEMA 실린더 팬텀을 사용하여, CT의 관전압과 관전류를 변경해가며 표준화섭취계수에 대한 변화를 추적하였다. MR torso coil안에 있는 금속 물질로 인한 줄무늬 인공물이 관찰되었다. CT 검사에 있어서 관전압과 관전류를 변화 시키면 선 감쇄계수도 일정하게 변화하였다. 관전압과 관전류의 수치가 높아짐에 따라 PET 영상에서의 표준화섭취계수가 증가하는 것을 볼 수 있었다. PET/CT 검사 시, MR torso coil은 금속으로 인한 줄무늬 인공물을 생성하며, 감쇄보정에 있어서 잠재적인 오류를 불러올 수 있다. 이와 같은 오류를 감소시키기 위해서는 첫째, 감쇄보정 알고리즘의 보완, 둘째, MR coil을 사용하지 않은 검사방법의 연구, 셋째, PET/CT 감쇄보정에 영향을 주지 않는 MR coil소재의 개발 등이 요구된다.

  • PDF

재생 방법에 따른 재생 폴리에스터사의 물성 변화 (Physical Properties of Recycled Polyester Yarns According to Recycling Methods)

  • 이선영;원종성;유재정;함완규;이승구
    • 한국염색가공학회지
    • /
    • 제24권1호
    • /
    • pp.91-96
    • /
    • 2012
  • The physical properties of recycled polyester yarns according to recycling methods were investigated. Virgin polyester draw texturized yarn(DTY), material-recycled(MR) polyester DTY and chemical-recycled(CR) polyester DTY were prepared. Surface morphology, thermal property, micro-structure and mechanical property of recycled polyester yarns were estimated. SEM-EDS analysis showed that the CR PET yarn had better crimp and more stable structure than MR PET yarn. Tm of the MR PET yarn was higher than that of the CR PET yarn. The intensity of the crystallization peak of the CR PET yarn was a little higher than that of the MR PET yarn. Tensile strength of the MR PET yarn was slightly higher than that of the CR PET yarn. Breaking elongation of the CR PET yarn was slightly higher than that of the MR PET yarn.

재구성 방법(점 확산함수 적용 유무)에 따른 PET/MR 영상 평가 (Comparison of PET/MR image quality with and without point spread function algorithm according to reconstruction type)

  • 박찬록;문일상;노경운
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.43-45
    • /
    • 2018
  • NEMA IEC body phantom으로 PET/MR 스캐너를 이용해 MR 영상 기반의 감쇠보정 된 PET 영상을 얻고, 반복재구성 기반의 점 확산 함수(PSF)에 적용 유무에 따라 PET 영상을 Contrast recovery 와 SNR 의 평가 인자를 적용해 평가하였다. 또한, 동일한 재구성 방법에 따라 본원의 내원한 환자의 영상도 평가하였다. 데이터는 임상환자 와 팬텀 실험 모두 PSF를 적용해 재구성한 영상이 모두 영상의 질이 향상됨을 확인하였다. MR 기반으로 얻어진 PET 영상 평가가 추후에도 계속해서 필요하다고 사료된다.

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • 대한방사성의약품학회지
    • /
    • 제1권2호
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.

3D Non-Rigid Registration for Abdominal PET-CT and MR Images Using Mutual Information and Independent Component Analysis

  • Lee, Hakjae;Chun, Jaehee;Lee, Kisung;Kim, Kyeong Min
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권5호
    • /
    • pp.311-317
    • /
    • 2015
  • The aim of this study is to develop a 3D registration algorithm for positron emission tomography/computed tomography (PET/CT) and magnetic resonance (MR) images acquired from independent PET/CT and MR imaging systems. Combined PET/CT images provide anatomic and functional information, and MR images have high resolution for soft tissue. With the registration technique, the strengths of each modality image can be combined to achieve higher performance in diagnosis and radiotherapy planning. The proposed method consists of two stages: normalized mutual information (NMI)-based global matching and independent component analysis (ICA)-based refinement. In global matching, the field of view of the CT and MR images are adjusted to the same size in the preprocessing step. Then, the target image is geometrically transformed, and the similarities between the two images are measured with NMI. The optimization step updates the transformation parameters to efficiently find the best matched parameter set. In the refinement stage, ICA planes from the windowed image slices are extracted and the similarity between the images is measured to determine the transformation parameters of the control points. B-spline. based freeform deformation is performed for the geometric transformation. The results show good agreement between PET/CT and MR images.

Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가 (Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study)

  • 도용호;이홍재;김진의;노경운
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.15-22
    • /
    • 2018
  • PET/MRI 검사 시 호흡에 의한 움직임은 영상의 질 저하는 물론 종양의 크기, 표준섭취계수의 오차를 발생시키는 원인이 된다. 본 연구에서는 일체형 PET/MRI 장비에서 MR기반 호흡 움직임 보정 방법의 적용에 따른 종양의 표준섭취계수, 크기와 영상 품질 변화를 평가하고자 하였다. Biograph mMR 3.0T (Siemens, Germany)장비에서 2016년 3월부터 7월까지 $^{18}F-FDG$ liver PET/MRI 검사를 시행한 30명 ($62.5{\pm}10.2$세)의 데이터를 분석하였다. 7분의 PET listmode 데이터를 획득하는 동안 MR 기반 호흡 움직임 보정 방법인 MAG, MTG와 NG T1 weighted MR 영상을 획득하였다. Gated PET 영상의 재구성은 35% efficiency window가 적용된 MAG와 MTG로부터 획득된 감쇄보정영상을 이용하여 시행하였다. Non-gate, MAG, MTG 영상에서 측정된 종양의 표준섭취계수와 Z축 방향의 크기 그리고 반치폭을 분석하였다 평균 $SUV_{max}$$SUV_{peak}$는 NG 대비 MAG 13.15%(P<0.0001), 8.66%(P<0.0001), MTG 13.27%(P<0.0001), 8.80%(P<0.0001) 증가하였으며 Z-축에서 평균 종양의 크기와 반치폭은 MAG 14.47%(P<0.0001), 15.49%(P=0.0004), MTG 14.89%(P<0.0001), 15.79%(P=0.0003) 감소하였으며 통계적으로 유의한 차이를 보였다. MAG와 MTG 비교 평가에서 MTG의 $SUV_{max}$$SUV_{peak}$는 MAG 대비 0.07%(P=0.8802), 0.13%(P=0.7766) 증가하였으며 Z-축에서 평균 종양의 크기와 반치폭은 0.49%(P=0.2786), 0.36%(P=0.2488) 감소하였다. 약 7분과 2분의 추가 검사시간이 필요한 MAG와 MTG에서 표준섭취계수와 종양의 크기, 반치폭에서 통계적으로 유의한 차이가 없었다. 간 PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법을 적용하였을 때 NG 대비 MAG, MTG 모두에서 표준섭취계수와 종양의 크기 및 공간분해능이 개선되었으며 MAG와 MTG의 결과 값은 통계적으로 유의한 차이가 없었다. 호흡에 의한 움직임에 영향을 받는 다양한 상 복부 검사에 MBRMCT를 적용 시 추가적인 장비의 설치 없이 약 2분의 추가 검사시간이 필요한 MTG 방법 적용하여 NG 대비 보다 정확한 정보를 제공할 수 있을 것으로 사료된다.

Feasibility study of improved median filtering in PET/MR fusion images with parallel imaging using generalized autocalibrating partially parallel acquisition

  • Chanrok Park;Jae-Young Kim;Chang-Hyeon An;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.222-228
    • /
    • 2023
  • This study aimed to analyze the applicability of the improved median filter in positron emission tomography (PET)/magnetic resonance (MR) fusion images based on parallel imaging using generalized autocalibrating partially parallel acquisition (GRAPPA). In this study, a PET/MR fusion imaging system based on a 3.0T magnetic field and 18F radioisotope were used. An improved median filter that can set a mask of the median value more efficiently than before was modeled and applied to the acquired image. As quantitative evaluation parameters of the noise level, the contrast to noise ratio (CNR) and coefficient of variation (COV) were calculated. Additionally, no-reference-based evaluation parameters were used to analyze the overall image quality. We confirmed that the CNR and COV values of the PET/MR fusion images to which the improved median filter was applied improved by approximately 3.32 and 2.19 times on average, respectively, compared to the noisy image. In addition, the no-reference-based evaluation results showed a similar trend for the noise-level results. In conclusion, we demonstrated that it can be supplemented by using an improved median filter, which suggests the problem of image quality degradation of PET/MR fusion images that shortens scan time using GRAPPA.