• 제목/요약/키워드: PEMFC Stack

검색결과 160건 처리시간 0.026초

공기공급 조건이 스택성능에 미치는 영향 (The effect of PEMFC stack performance at air supply condition)

  • 박창권;오병수
    • 한국수소및신에너지학회논문집
    • /
    • 제19권3호
    • /
    • pp.232-238
    • /
    • 2008
  • Research has been proceeded on fuel cell which is fueled by hydrogen. Polymer electrolyte membrane fuel cell (PEMFC) is promising power source due to high power density, simple construction and operation at low temperature. But it has problems such as high cost, temperature dependent performance. These problems could be solved by experiment which is useful for analysis and optimization of fuel cell performance and heat management. In this paper, when hydrogen flows constantly at the stoichiometry of ${\xi}=1.6$, the performance of the fuel cell stack was increased and the voltage difference between each cells was decreased according to the increase of air stoichiometry by 2.0, 2.5, 3.0. Therefore, the control of air flow rate in the same gas channel is important to get higher performance. Purpose of this research is to expect operation temperature, flow rate, performance and mass transportation through experiment and to help actual manufacture of PEM fuel cell stack.

연료전지의 CO 피독 및 회복에 관한 연구 (Study of performance of a stack in the presence of CO and air)

  • 김희수;김동찬;한지희;이호준
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.180-183
    • /
    • 2007
  • CO in the reformed gas for proton exchange membrane fuel cell(PEMFC) has a strong tendency to adsorb on the surface of the catalyst and thus to block the sites that hydrogen needs for reactions. Even part per million levels of CO can cause serious poisoning. This CO poisoning can overcome to bleed trace amounts of air into the anode. In this study, we indicated the alteration of stack performance in various CO concentration and then bled a small amount of air. The performance of stack was reduced by increasing CO amount, and recovered by air bleeding. But the air-bleeding have an impact on performance of anode should be further explored.

  • PDF

Perfonnance Evaluation of Single Cell and Stack of PolymerElectrolyte Fuel Cell by Using Transfer Printing Technique

  • KIM, CHANG SOO;CHUN, YOUNG-GAB;PECK, DONG-HYUN;YANG, TAE-HYUN
    • 한국수소및신에너지학회논문집
    • /
    • 제11권1호
    • /
    • pp.19-27
    • /
    • 2000
  • The polymer electrolyte membrane fuel cell (PEMFC) system was developed. In order to enhance the performance of membrane electrode assembly (MEA), the transfer printing method of the electrocatalyst layer on membrane was developed. The $H_2/O_2$ single cell with an electrode area of $50cm^2$ was fabricated and tested using 20 wt.% Pt/C as an electrocatalyst and the commercial and hand-made MEA such as Nafion 115, Hanwha, Dow, Flemion T and Gore Select. The 100-cell PEMFC stack with an active electrode area of $300cm^2$ was designed and fabricated using 40 wt.% Pt/C and 30 wt.% Pt-Ru/C as a cathode and anode electrocatalysts, respectively. The performance of PEMFC system was obtained to be 7kW (250A at 28V) and 3.5kW (70A at 50V) at $80^{\circ}C$ by flowing $H_2/air$ and methanol reformed fuel gas/air, respectively.

  • PDF

독립형 500W PEMFC 시스템의 최적 설계 및 구동 특성에 관한 연구 (A Study on Optimal Design and Operational Features of a Stand-alone 500W PEMFC System)

  • 박세준;하민호;최홍준;차인수;윤정필;임중열
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.320-322
    • /
    • 2008
  • The international oil price now has been going up every each day, about 120 USD per a gallon April 2008, so that most of countries in the world are concern of the the shortage of petroleum and the development of new and renewable energy resources. This paper presents optimal design and operational features of stand-alone 500W PEMFC(Proton Exchange Membrane Fuel Cell) system which can be a substitute instead fossil fuel. The stack of PEMFC is composed of 35 laminated graphites, and a unit cell of the stack has electrical characteristics as below; 14W, 0.9V, 15A. The other components of BOP(Balance of Plant) are composed of hydrogen and nitrogen tanks, regulators, 3way solenoid valves, mass flow meters, etc.

  • PDF

열전달 및 열하중을 고려한 자동차 연료전지(PEMFC) 분리판의 두께 최적설계 (Optimization of Automotive PEMFC Bipolar Plates considering Heat Transfer and Thermal Loads)

  • 김영성;김철
    • 한국자동차공학회논문집
    • /
    • 제23권1호
    • /
    • pp.34-40
    • /
    • 2015
  • A stack in the proton exchange membrane fuel cell (PEMFC) consists of bipolar plates, a membrane electrode assembly, a gas diffusion layer, a collector and end plates. High current density is usually obtainable partially from uniform temperature distribution in the fuel cell. A size optimization method considering the thermal expansion effect of stacked plates was developed on the basis of finite element analyses. The thermal stresses in end, bipolar, and cooling plates were calculated based on temperature distribution obtained from thermal analyses. Finally, the optimization method was applied and optimum thicknesses of the three plates were calculated considering both fastening bolt tension and thermal expansion of each unit cell (72 cells, 5kW). The optimum design considering both thermal and mechanical loads increases the thickness of an end plate by 0.64-0.83% the case considering only mechanical load. The effect can be enlarged if the number of stack increases as in an automotive application to 200-300 stacks.

과도 응답 특성을 고려한 고분자 전해질 연료전지(PEMFC) 모델링 (Proton exchange membrane fuel cell stack modeling considering dynamic response characteristics)

  • 장예지;김나영;한경희;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1086_1087
    • /
    • 2009
  • 본 논문에서는 과도 응답 특성에 따른 고분자 전해질 연료전지(PEMFC)를 모델링하였다. 연료전지에 이러한 과도특성이 일어나는 것에 원인에 대하여 분석해보고, 실제 실험을 통해 과도특성이 일어나는 것을 확인하였다. 실험결과 파형을 분석하여 Matlab & Simulink를 이용하여 PEMFC의 과도 응답 특성을 모델링하였다.

  • PDF

가정용 연료전지 시스템 동특성 해석 모델 (A Dynamic Model of PEMFC for Residential Power Generator)

  • 유상석;김한석;이상민;이영덕;안국영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.12-16
    • /
    • 2007
  • A dynamic model of proton exchange membrane fuel cell(PEMFC) system is designed to understand the performance of the PEMFC in residential power generator(RPG) over various balance of plant(BOP) options. In particular, since the performance of PEMFC system should be optimized for given operating ranges, it is necessary to design suitable BDP components which can support the operating ranges. The objective of this study is to develop a dynamic system model for the study of PEMFC performance over various BOP options. Therefore, a dynamic model is composed of a PEMFC stack model, a water management system model, a thermal management system model and a fuel/air supply model and the model is integrated under SIMULINK(R)environment. Basic simulation results will be presented.

  • PDF

In-Situ 분석법에 의한 연료전지 특성 연구 (PEMFC Characterization Study by in-situ Analysis Method)

  • 김영민;이종현;임세준;안병기;임태원
    • 한국수소및신에너지학회논문집
    • /
    • 제20권3호
    • /
    • pp.208-215
    • /
    • 2009
  • PEMFC stack power output is needed to be around 100 kW to meet the requirements of automotive application and scaling-up the active area of the stack cells will allow a higher power. In the case of scaling-up the active area of cells, it is difficult to obtain uniform in-plane internal conditions such as temperature, relative humidity and stoichiometry of the feed gas. These ununiformity with the location in the cell would affect both the performance and durability of the stack, so it is important to understand phenomena in the cell for improving them. In this study, the current density, electrochemical resistance and performance distribution measurement was performed to understand the ununiformity in a single cell using in-situ method; (1) Current Density Distribution (CDD) Device and (2) Segmented Cell Fixture. The influence of location of feed gas on the performance of a single cell was experimentally measured and discussed by using a segmented single cell which was composed of 8 compartments. The correlation between the location and performance in a single cell was discussed by these two tools and it was extended between the local characterization and the durability in a MEA by comparing the used cell with a fresh one. It was also studied in terms of electrochemistry by Electrochemical Impedance Spectroscopy.

차량용 PEMFC 동적 모델을 이용한 시스템 부하 응답 특성 (System Response of Automotive PEMFC with Dynamic Modeling under Load Change)

  • 한재영;김성수;유상석
    • 한국자동차공학회논문집
    • /
    • 제21권1호
    • /
    • pp.43-50
    • /
    • 2013
  • The stringent emission regulation and future shortage of fossil fuel motivate the research of alternative powertrain. In this study, a system of proton exchange membrane fuel cell has been modeled to analyze the performance of the fuel cell system for automotive application. The model is composed of the fuel cell stack, air compressor, humidifier, and intercooler, and hydrogen supply which are implemented by using the Matlab/Simulink(R). Fuel cell stack model is empirical model but the water transport model is included so that the system performance can be predicted over various humidity conditions. On the other hand, the model of air compressor is composed of motor, static air compressor, and some manifolds so that the motor dynamics and manifold dynamics can be investigated. Since the model is concentrated on the strategic operation of compressor to reduce the power consumption, other balance of components (BOP) are modeled to be static components. Since the air compressor model is empirical model which is based on curve fitting of experiments, the stack model is validated with the commercial software and the experiments. The dynamics of air compressor is investigated over unit change of system load. The results shows that the power consumption of air compressor is about 12% to 25% of stack gross power and dynamic response should be reduced to optimize the system operation.