Study of performance of a stack in the presence of CO and air

연료전지의 CO 피독 및 회복에 관한 연구

  • 김희수 ((주) 효성중공업 중공업연구소 분산전원 시스템팀) ;
  • 김동찬 ((주) 효성중공업 중공업연구소 분산전원 시스템팀) ;
  • 한지희 ((주) 효성중공업 중공업연구소 분산전원 시스템팀) ;
  • 이호준 ((주) 효성중공업 중공업연구소 분산전원 시스템팀)
  • Published : 2007.06.21

Abstract

CO in the reformed gas for proton exchange membrane fuel cell(PEMFC) has a strong tendency to adsorb on the surface of the catalyst and thus to block the sites that hydrogen needs for reactions. Even part per million levels of CO can cause serious poisoning. This CO poisoning can overcome to bleed trace amounts of air into the anode. In this study, we indicated the alteration of stack performance in various CO concentration and then bled a small amount of air. The performance of stack was reduced by increasing CO amount, and recovered by air bleeding. But the air-bleeding have an impact on performance of anode should be further explored.

Keywords