• 제목/요약/키워드: PEEK(Poly Ether Ether Ketone)

검색결과 21건 처리시간 0.032초

반응성 기체를 첨가한 저 에너지 이온빔 처리에 의한 고분자와 금속 간의 계면 접착력 증가에 관한 연구 (Enhanced Interfacial Adhesion between Polymers and Metals(Cu) by Low Energy Ion-beam Irradiation with Reactive Gases)

  • 이지석;서용석;김한성;강태진
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.75-78
    • /
    • 2005
  • Using a low-energy Ar+ ion-beam with and without reactive gases, polymers such as chemically stable poly(ether ether ketone) (PTFE) and poly(ether ether ketone) (PEEK) films were modified to have special surface features. The adhesion strength between the polymers and the copper was significantly improved because of both changes in the surface topography and chemical interactions due to polymer surface functionalization (oxidation and amination). The surface modification altered the failure mode from adhesive failure for the unmodified polymer/Cu interface to cohesive failure for the surface-modified polymer/Cu layer interface..

  • PDF

PEMFC용 설폰화 Poly(ether ether ketone) (SPEEK) 전기방사 나노섬유 이온교환막의 제조 및 특성 (Preparation and Properties of Sulfonated Poly(ether ether ketone) (SPEEK) Electrospun Nanofibrous Ion-exchange Membrane for PEMFC)

  • 곽노석;최은정;황택성
    • 폴리머
    • /
    • 제36권2호
    • /
    • pp.155-162
    • /
    • 2012
  • 전기방사 방법으로 sulfonated poly(ether ether ketone) (SPEEK) 나노섬유를 제조하고, 압축성형법으로 고분자 전해질막 연료전지(polymer electrolyte membrane fuel cell, PEMFC)용 나노섬유막을 제조하였다. SPEEK의 최대 설폰화율은 95% 이었고 초기 열분해 온도는 약 $280^{\circ}C$로 PEEK 보다 낮았으며 접촉각은 설폰화도가 증가함에 따라 감소하였다. 전기방사 나노섬유의 최적 인가전압, 유속, 방사거리(tip to collector distance, TCD) 및 농도는 각각 22 kV, 0.3 mL/hr, 5 cm, 23 wt% 이었고 평균 섬유직경은 47.6 nm 이었다. 한편, SPEEK 이온교환 나노섬유막의 함수율 및 이온교환용량은 설폰화 시간과 설폰화제 함량이 증가함에 따라 증가하였으며 최적값은 각각 20%, 2.03 meq/g으로 Nafion 117 보다 우수하였다. 막의 전기저항은 설폰화 시간이 증가함에 따라 감소하였고 그 값은 0.58~0.06 ${\Omega}{\cdot}cm^2$로 측정되었다. 또한 막의 수소이온전도도는 설폰화 시간이 증가함에 따라 증가하였으며 최대 0.099 S/cm로 Nafion 117 보다 우수하였다.

직접 불소화에 의해 표면 개질된 SPEEK/APSf, SPEEK/APEI 바이폴라막을 이용한 차아염소산나트륨 생성 (Hypochlorite Production by Using SPEEK/APSf and SPEEK/APEI Bipolar Membranes Modified by the Direct Fluorination)

  • 김가영;정성일;임지원
    • 멤브레인
    • /
    • 제25권5호
    • /
    • pp.447-455
    • /
    • 2015
  • 본 연구에서는 Polysulfone (PSf), Polyetherimide (PEI)를 각각 비율을 달리하여 아민화하였고, Polyether ether ketone (PEEK)을 설폰화하였다. 합성한 두 이온교환고분자를 더블캐스팅방법으로 SPEEK (sulfonated PEEK)/APSf (aminated PSf) 및 SPEEK/APEI (aminated PEI) 바이폴라막을 제조하였다. 각각의 막 표면을 불소화하고, 아민화 비율에 따라 차아염소산나트륨발생량을 비교하였다. 아민화 비율이 증가할수록 차아염소산나트륨 발생 농도 또한 증가하였다. SPEEK/APSf 3 : 1 막의 경우 불소화 전의 차아염소산나트륨 농도와 총 운전시간은 61.0 ppm, 220 min이고, 불소화한 막의 경우 58.6 ppm, 570 min이다. 또한 SPEEK/APEI 3 : 1 막에서 역시 불소화 전후의 차아염소산나트륨 농도는 각각 60.1 ppm, 58.3 ppm이고, 총 운전시간은 150 min에서 440 min으로 내구성이 크게 향상되었다. 따라서 표면 불소화가 막의 내구성에 중요한 역할을 한다고 사료된다.

방사선 열화에 따른 PEEK의 유전특성과 동적 기계적 특성 (Dielectric Analysis and Dynamic Mechanical Analysis of Radiation Degradation of PEEK)

  • 김기엽;강현구;류부형;이청;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.485-488
    • /
    • 2003
  • Radiation degradation of Poly(ether ether ketone) (PEEK) has been studied by dielectric analysis and dynamic mechanical analysis. It has been observed that dielectric properties are influenced by radiation degradation of PEEK. For radiation degradation of PEEK, dynamic mechanical properties were insensible.

  • PDF

A MOLECULAR SIMULATION STUDY ON BETA-CYCLODEXTRIN POLYMERIC MEMBRANES

  • Tocci, Elena;Fama, Angelo;Perrone, Maria Pia;Russo,Nino;Drioli, Enrico
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2003년도 The 4th Korea-Italy Workshop
    • /
    • pp.57-59
    • /
    • 2003
  • Molecular dynamics simulations have been performed on $\beta$-cyclodextrins octyl-derivative (b-CD) encapsulated into a polymer matrix of glassy poly(ether ether ketone) (PEEK-WC) material to investigate the effects of the complexation of p-nitrophenilacetate and naringin molecules with the aim to study the recognition properties of b-CD.

  • PDF

X-ray Diffraction Studies of Poly(aryl ether ether ketone) Fibers with Different Degrees of Crystallinity and Orientation

  • Karacan Ismail
    • Fibers and Polymers
    • /
    • 제6권3호
    • /
    • pp.206-218
    • /
    • 2005
  • Structural studies of series of 'as spun' and drawn PEEK fibers have been carried out using X-ray diffraction and optical microscopy techniques. The analysis of results suggest that fibers produced at a constant draw ratio with increasing draw temperatures show enhanced orientation and crystalline behaviour. The resolved equatorial and meridional traces provide additional structural parameters in terms of crystallinity, crystallite size, and crystallite thickness. It is concluded that drawing at a temperature below $T_g(i.e.,\;144^{\circ}C)$ results in poorly oriented non-crystalline materials, whereas drawing above $T_g$ results in highly oriented semi crystalline materials. Additional drawing proved to increase the overall orientation with slight improvements in lateral order of the chain molecules. Quantitative analysis revealed that the crystallite size increases with increasing drawing temperature. The results also revealed the increased crystallite size upon additional drawing. Crystalline orientation parameter, $_c$, suggests almost perfect orientation. In all cases, the amorphous orientation is found to be lower than the overall orientation parameter obtained from the optical birefringence. As a result of additional drawing, crystalline orientation was found to increase slightly but the increase in the orientation of non-crystalline material was found to be substantial. An average crystalline density was determined from the orthorhombic unit cell dimensions. It was found to vary as a result of processing conditions. It was also found that the value of the maximum birefringence shows heavy dependence on the chain conformation.

고분자 전해질 연료전지에서 sPEEK 막을 이용한 전극과 막 합체(MEA)의 열화에 관한 연구 (Study on the Degradation of MEA Using Sulfonated Poly(ether ether ketone) Membrane in Proton Exchange Membrane Fuel Cells)

  • 이혜리;이세훈;황병찬;나일채;이정훈;오성준;박권필
    • Korean Chemical Engineering Research
    • /
    • 제54권3호
    • /
    • pp.305-309
    • /
    • 2016
  • 최근에 저가의 고분자 전해질 연료전지(Proton Exchange Membrane Fuel Cells, PEMFC)용 비불소계 전해질 막 연구개발이 활발히 진행되고 있다. 본 연구에서는 sulfonated Poly (ether ether ketone) (sPEEK) MEA 내구성을 시험하기 위해 열화 가속화 기법을 이용하여 막과 전극이 동시에 열화되는 MEA 열화 실험을 진행하였다. 열화 전과 후에 I-V 분극곡선, 수소투과도, 전극 활성 면적, 막 저항과 부하 전달 저항을 측정하여 열화 전과 후를 비교하였다. sPEEK 막의 수소 투과도는 낮았지만, 저가습 OCV 조건에서 발생하는 라디칼에 Nafion과 같은 불소계막보다 sPEEK 막이 약했다. MEA 열화 실험 결과 144시간 후와 271시간 후 성능이 각각 15%와 65% 감소하였다. 144이후 급격한 성능감소의 주요인은 막에 발생한 핀홀의 Pt/C 입자에 의한 shorting 현상이라고 본다.

소산입자동역학과 분자동역학을 이용한 3D 프린터용 PEEK 분말에 대한 온도에 따른 미시적 구조변화에 대한 연구 (Investigation of Temperature-Dependent Microscopic Morphological Variation of PEEK Powder for a 3D Printer using Dissipative Particle and Molecular Dynamics Simulations)

  • 김남원;이태일
    • 한국기계가공학회지
    • /
    • 제17권5호
    • /
    • pp.117-122
    • /
    • 2018
  • 3D printing technology and its applications have grown rapidly in academia and industry. We consider a 3D printing system designed for the selective laser sintering (SLS) method, which is one of the powder bed fusion (PBF) techniques to build up the final product by layering sintered powder slices. Thermal distortion of printing products is a critical challenge in 3D printing. This study investigates temperature-dependent conformational behaviors of 3D printed samples of sintered poly-ether-ether-ketone (PEEK) powders using molecular dynamics simulations. The wear and chemical resistance properties of PEEK are understood, as it is a well-known biocompatible material used for implants. However, studies on physical phenomena at nanoscale in PEEK are rarely published in public. We simulate dissipative particle dynamics to elucidate how a cavity regime forms in PEEK at different system temperatures. We demonstrate how PEEK structures deform subject to the system temperature distribution.

SPEEK-Ag+ 촉진 수송막을 이용한 Propylene/Propane의 분리 (Separation of Propylene/Propane using SPEEK-Ag+ Facilitated Transport Membrane)

  • 이정인;장성철;최도영;방준하;김훈식;최대기
    • Korean Chemical Engineering Research
    • /
    • 제46권1호
    • /
    • pp.164-169
    • /
    • 2008
  • 본 연구에서 매개체로 $Ag^+$ 이온을 사용하고 polycarbonate 지지체 위에 sulfonated poly(ether ether ketone)(SPEEK) 코팅하여 촉진 수송 분리막을 제조하여 propylene/propane의 분리에서 막의 두께와 은의 농도의 영향을 알아보았다. PEEK와 황산을 이용하여 SPEEK를 합성하고 MeOH에 녹여 농도별(5, 10, 15, 20 wt%)로 polycarbonate 지지체 위에 코팅하였고, 은 수용액에 함침 시킨 후 어두운 곳에서 건조하여 사용하였다. 실험 결과, 막의 두께 증가하면 선택도는 증가하였고 투과 성능은 감소하였다. 또한 은의 농도가 증가할수록 선택도는 증가 하였으나, 투과 성능을 크게 변화 시키지는 않았다.

Improvement of Plating Characteristics Between Nickel and PEEK by Plasma Treatment and Chemical Etching

  • Lee, Hye W.;Lee, Jong K.;Park, Ki Y.
    • Corrosion Science and Technology
    • /
    • 제8권1호
    • /
    • pp.15-20
    • /
    • 2009
  • Surface of PEEK(poly-ether-ether-ketone) was modified by chemical etching, plasma treatment and mechanical grinding to improve the plating adhesion. The plating characteristics of these samples were studied by the contact angle, plating thickness, gloss and adhesion. Chemical etching and plasma treatment increased wettability, adhesion and gloss. The contact angle of as-received PEEK was $61^{\circ}$. The contact angles of chemical etched, plasma treated or both were improved to the range of $15{\sim}33^{\circ}$. In the case of electroless plating, the thickest layer without blister was $1.6{\mu}m$. The adhesion strengths by chemical etching, plasma treatment or both chemical etching and plasma treatment were $75kgf/cm^2$, $102kgf/cm^2$, $113kgf/cm^2$, respectively, comparing to the $24kgf/cm^2$ of as-received. In the case of mechanically ground PEEKs, the adhesion strengths were higher than those unground, with the sacrifice of surface gloss. The gloss of untreated PEEK were greater than mechanically ground PEEKs. Plating thickness increased linearly with the plating times.