• 제목/요약/키워드: PDP(Plasma display Panel)

검색결과 564건 처리시간 0.026초

AC PDP에서 2차원 수치해석을 이용한 Ramp Reset 구동파형에 따른 방전 특성 분석 (Discharge Characteristic Analysis with a Ramp Reset Waveform Using 2-Dimensional Simulation in the PDP)

  • 박석재;최훈영;서정현;이석현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.192-194
    • /
    • 2003
  • In this paper, we present a 2-Dimensional simulation model of the discharge in an ac plasma display panel cell. Therefore, we study a ramp reset waveform in an ac plasma display panel discharge cell using 2-Dimensional simulation. Finally We research a connection between priming particles' density and stability.

  • PDF

Ar Gas 첨가에 따른 칼라 플라즈마 디스플레이 패널의 효율 향상 (Color AC Plasma Display Panel of Luminous Efficiency Improvement by adding Ar Gas)

  • 최훈영;민병국;이석현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.919-921
    • /
    • 1998
  • In Color AC Plasma Display Panel(PDP). Low luminous efficiency is a major problem. We measured luminous efficiency of PDP as a function of the Ar mixing ratio. Our results show that efficiency has improved by $5{\sim}10%$ at the condition of 0.5% Ar mixing ratio, compared with Ne-Xe(4%) or He-Ne-Xe(4%) (He:Ne = 7:3) gas.

  • PDF

영역 카메라를 이용한 플라즈마 디스플레이의 컬러출력 검사 시스템 (Color Inspection System for Plasma Display Panel by Using Area Camera)

  • 김우섭;도현철;진성일
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅳ
    • /
    • pp.1763-1766
    • /
    • 2003
  • This paper proposes a non-contact color inspection system for plasma display panel (PDP). The red, green, and blue test pattern images are acquired by using the area color CCD camera at the various distance from the PDP. The RGB values are obtained from the region of interest (ROI) which are extracted by applying the image processing to the test pattern image. Finally, the CIE xy and u'v' chromaticity coordinates of the test pattern images according to the distance are acquired from the RGB color coordinates.

  • PDF

Realization of High Luminous Efficacy PDP with Low Voltage Driving

  • Whang, Ki-Woong;Bae, Hyun-Sook;Jung, Hae-Yoon;Kwon, O-Hyung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.153-156
    • /
    • 2008
  • The use of high Xe content gas is a powerful method for improving the discharge efficacy in PDP, but the accompanying high driving voltage prevents it from being used aggressively. In this paper, we tried to find a method to lower the driving voltage under high Xe gas condition with a new protecting layer. The effective secondary electron emission caused by Xe ions can result in the low voltage driving in panels with high Xe content gas and more importantly high luminous efficacy which were confirmed with the computer simulation and panel experiment.

  • PDF

Analysis of Energy Flow and Barrier Rib Height Effect using Ray-Optics Incorporated Three-dimensional PDP Cell Simulation

  • Chung, Woo-Joon;Jeong, Dong-Cheol;Whang, Ki-Woon;Park, Jae-Hyeung;Lee, Byoung-Ho
    • Journal of Information Display
    • /
    • 제2권4호
    • /
    • pp.46-51
    • /
    • 2001
  • Using ray-optics code incorporated with three-dimensional PDP cell simulation, we have analysed the energy flow in the PDP cell from the electric power input to the visible light output. Also, the visible light output profile and viewing angle distribution were obtained. We applied our code to the analysis of the barrier rib height effect on the visible light luminance and efficiency of the sustaining discharge. Although cells with higher barrier rib generate more VUV photons, less ratio of visible photons are emitted toward front panel due to the shadow effect. Thus, there exists optimal barrier rib height giving the highest visible luminance and efficiency. This kind of code can be a powerful tool in designing cell geometry.

  • PDF

High Performance and Low Cost Single Switch Current-fed Energy Recovery Circuits for AC Plasma Display Panels

  • Han Sang-Kyoo;Youn Myung-Joong
    • Journal of Power Electronics
    • /
    • 제6권3호
    • /
    • pp.253-263
    • /
    • 2006
  • A high performance and low cost single switch current fed energy recovery circuit (ERC) for an alternating current (AC) plasma display panel (PDP) is proposed. Since it is composed of only one power switch compared with the conventional circuit consisting of four power switches and two large energy recovery capacitors, the ERC features a simpler structure and lower cost. Furthermore, since all power switches can be switched under soft switching operating conditions, the proposed circuit has desirable merits such as increased reliability and low switching loss. Specifically, there are no serious voltage notches across the PDP with the aid of gas discharge current compensation, which can greatly reduce the current stress of all inverter switches, and provide those switches with the turn on timing margin. To confirm the validity of proposed circuit, its operation and performance were verified on a prototype for 7-inch test PDP.

The 2-dimensional Discharge Cell Simulation for the Analysis of the Peset and Addressing of an Alternating Current Plasma Display Panel

  • Kim, Joong-Kyun;Chung, Woo-Jun;Seo, Jeong-Hyun;Whang, Ki-Woong
    • Journal of Information Display
    • /
    • 제2권1호
    • /
    • pp.24-33
    • /
    • 2001
  • The characteristics of the reset and the address discharges of an alternating current Plasma Display Panel (ac PDP) were studied using 2-dimensional numerical discharge cell simulation. We investigated the wall charge variations during the reset discharge adopting ramping reset pulse and the subsequent addressing discharge. The roles of the ramping reset scheme can be divided into two stages, each electrode gathers wall charges during ramping-up of the initial stage and the built-up wall charges are lost during ramping-down of the later stage. Address discharge does not only change the wall charge distributions on the address and the scan electrodes but also on the sustain electrode. The increase in the wall charges on the sustain electrode was observed with the variation of the applied voltage to the sustain electrode during the address period. The increase of the applied voltage to the sustain electrode during the address period is expected to induce the decrease of the sustain voltage during the display period.

  • PDF

어드레스 오방전 보상 저가형 플라즈마 디스플레이 패널 TV 구동 시스템 (Cost Effective Plasma Display Panel TV Driving system with an address misfiring compensation circuit)

  • 이강현;이대식
    • 한국산업정보학회논문지
    • /
    • 제18권3호
    • /
    • pp.1-8
    • /
    • 2013
  • 본 논문에서는 최근 3D 콘텐츠의 증가로 다시 주목을 받고 있는 PDP TV를 위한 저가형 구동 시스템을 제안한다. PDP TV의 경우 기체 방전을 이용하여 영상을 표시하는 장치로서 진공 상태의 패널에 수많은 전압을 가하여 플라즈마 상태로 만든 다음 영상 신호에 의하여 영상 및 밝기가 표현된다. 이러한 PDP TV는 많은 전압을 가하기 위하여 3개 전극에 각각 필요한 구동회로 보드가 붙게 되는데, 대 전력을 다루기 때문에 보드 사이즈와 사용되는 소자가 큰 가격을 차지하고 있다. 본 논문에서는 기존의 3개의 보드로 이루어진 구동 시스템을 오방전을 보상하기 위한 어드레스 에너지 회수 구동회로를 포함한 2개 보드로 이루어진 새로운 저가형 PDP TV 구동회로를 제안하고 이를 42인치 HD PDP TV를 통해 검증한다.

PDP 고효율 고화질 구동 알고리즘 설계 및 FPGA 구현 (A new Driving Algorithm Design and Implementation for High Efficiency and High Image Quality in PDP)

  • 차수익;이동호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.152-154
    • /
    • 2005
  • This paper proposes the new subfield method to erase reverse gray levels and low gray level contour in AC plasma display panel(PDP). In the conventional method, it is supposed that output luminance levels of a PDP increase regularly. But actual output luminance levels of a PDP increase irregularly. Therefore, conventional methods are unable to effectively reduce low gray-level contours and reverse gray levels. Accordingly, a new subfield method is applied to improve the low gray-level expression in PDP. Conclusively this paper clear proof that a new subfield method can suppress low gray-level contours and reverse gray levels more effectively than conventional methods.

  • PDF

Plasma Display Panel용 기판 유리의 조성과 성질 (Composition and Properties of Substrate Glasses for Plasma Display Panel)

  • 김기동;정우만;권성구;최세영
    • 한국세라믹학회지
    • /
    • 제43권5호
    • /
    • pp.293-298
    • /
    • 2006
  • For substrate glass applied to PDP (Plasma Display Panel), it has been developed many glass compositions that have to not only meet the specifications of PDP but also satisfy the float process as production technology. In the present work several compositions with no deformation at PDP processing temperature and thermal expansion coefficient of $83{\sim}9{\times}10^{-7}/K$ were designed. Based on viscosity at high temperature and liquidus temperature for those compositions, three candidate compositions named T-2, T-4, T-6 were selected finally. It was examined additionally that thermal shrinkage at PDP processing temperature and visible transmittance. The properties of T-series were compared with those of commercial glasses and discussed from the view point of PDP device and glass production.