• 제목/요약/키워드: PD signal

검색결과 380건 처리시간 0.027초

부분방전 신호의 누적검출과 뉴럴-퍼지 알고리즘을 이용한 컴퓨터 진단에 관한 연구 (A study on the computer diagnosis that apply Neural-Fuzzy algorithm accumulation detection of Partial Discharge signal)

  • 황경준;염경태;김용갑;김진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1445-1446
    • /
    • 2007
  • In this paper, we have studied for analysis of the partial discharge(PD) signal in power transmission line. The PD signal has estimated as detected signal accumulation of a PRPDA method by using Labview, and analyzed with neural-fuzzy algorithm. With practical PD logic implementation of theoretical detected system and hardware implementation, the device for Hipotronics Company's 22.9kV or 154kV setup have generated and then have applied with 18kV,20kV with 1:1 time probe. It's also used the LDPE 0.27mmt (scratch error 0.05mmt) to sample for making PD. Our new class of PD detected algorithm have also compared with previous PRPDA or Neural Fuzzy algorithm, which has diagnose more conveniently by adding numerical values.

  • PDF

신호처리 기술에 의한 부분방전 방사전자파의 특징 추출 (The Feature Extraction of Partial Discharge Electromagnetic Wave utilizing Signal Processing Techniques)

  • 이현동;이광식
    • 조명전기설비학회논문지
    • /
    • 제16권1호
    • /
    • pp.44-49
    • /
    • 2002
  • 최근 고전압 전력기기에서의 부분방전을 측정하기 위한 다양한 절연진단 기술들이 소개되었다. 부분방전 신호는 아주 미약하고 주변환경의 여러잡음에 쉽게 영향을 받으므로 주위 노이즈와의 구별이 어려운 실정이다. 본 논문에서는 부분방전 검출법중 부분방전에 의해 방사되는 전자파를 안테나로 측정하는 방사전자파법을 이용하여 변전소 구내의 배경잡음과 실험실내의 모의 부분방전을 방사전자파법에 의해 측정분석하였다. 또한 간섭신호와 모의 부분방전시 방사되는 방사전자파의 특징을 추출하고, 그 인식을 위하여 웨이브렛 패킷 변환을 이용하였다. 그 결과 간섭신호와 부분방전의 특정주파수대역의 시간정보 특징으로 그 차이를 구별할 수 있었다.

부분방전신호로부터 노이즈의 제거를 위한 웨이블렛필터링 기법의 적용 (Application of wavelet filtering for Suppression of noise from PD signals)

  • 이강원;박철현;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1845-1848
    • /
    • 2003
  • PD(Partial Discharge) signal have the range from several kHz to several GHz. External noises don't give any interference to discerning PD signals with high frequency bandwidth between several hundreds MHz to several GHz but, in the range between several decades kHz to several MHz, are big obstacles to prevent from discriminating PD signals. Therefore, selecting appropriate filter to decrease the influence of noise is important problem. PD signals have the characteristics both short duration and non-continuous pulse train. For separating PD signals from External noises, some different filtering methods different from conventional ones are needed and wavelet filtering method was convinced to be suitable filtering method in various investigations. This paper has simulated PD signal and various noises and investigated the influences for the performance of wavelet filter by varying the components relative to designing of wavelet filter and constructed suitable one. For the purpose of convincing the performance of wavelet filter, real PDs were produced in needle to plane electrode structure. This small PD signal was mixed with external noises and filtered with wavelet filter. We have obtained apparent PD signals and noises are well suppressed by wavelet filter.

  • PDF

2개 센서를 이용한 부분방전 위치추정 기법 연구 (A Study on the Partial Discharge Location Method using 2 Sensors)

  • 김정태;김동욱
    • 전기학회논문지
    • /
    • 제61권2호
    • /
    • pp.251-256
    • /
    • 2012
  • This study deals with the location of partial discharges(PDs) for power cables and GIS using 2 PD sensors and long coaxial signal cables. Throughout the experiments by use of simulated PD pulses and corona discharges in the power cable system, it is found out that the impedance matching between the coaxial signal cable and the measuring equipment should be done for good S/N ratio and the on-site measurement using more than 100m-long coaxial signal cable is possible. In addition, new PD location algorithm with the polarities of PD pulses and the arrival time difference between two pulses was proposed and was proved through the partial discharge experiments for the cable joint defect and artificial void defect.

안테나로 측정된 부분방전신호의 노이즈제거 관한 연구 (The study on the de-noise for partial discharge signal measured using the antenna)

  • 김영노;김재철;전영재;서인철;배주천;강창원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.404-406
    • /
    • 2001
  • This paper is detecting a partial discharge(PD) using antenna. The wavelet transform is applied for the analysis of PD pulse signal. It is difficult to identify PD signal using electromagnetic waves detected by antenna. And so we can removed noise of PD signal using wavelet de-noising method.

  • PDF

초음파 전달특성과 신경망을 이용한 효과적인 부분방전 위치 추정 (Effective Location Estimation of Partial Discharge Using Ultrasonic Signal's Propagation Characteristic and Neural Network)

  • 서인철;김재철;전영재;김영노
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.467-469
    • /
    • 2001
  • This paper presents an efficient location estimation methodology for a partial discharge(PD) source in the power transformer. The methodology previously proposed is not suitable for locating a PD source because the ultrasonic signal with medium attenuated through the inner structure. In general, the propagation characteristic of ultrasonic signal with medium is different. Therefore, using this propagation characteristic, we can detect the location of PD source. In this paper, the proposal algorithm finds the PD source using three sensors attached to one side of the transformer without attenuation of the ultrasonic signal and applying the neural network based geometrical method. The proposed methodology demonstrates the effectiveness and validity on an experimental transformer.

  • PDF

뉴로-퍼지 알고리즘을 이용한 전력 설비의 열화 상태 분석 연구 (A Study on the degradation Analysis Using Neuro-Fuzzy Algorithm)

  • 황경준;이현룡;최유순;김용갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.224-226
    • /
    • 2006
  • In this paper, we have studied for analysis of the partial discharge(PD) signal in power transmission line. The PD signal has estimated as detected signal accumulation of a PRPDA method by using Labview, and analyzed with neuro-fuzzy algorithm. With practical PD logic implementation of theoretical detected system and hardware implementation, the device for Hipotronics Company's 22.9kV or 154kV setup has generated and then has applied with 18kV,20kV with 1:1 time probe. It's also used the LDPE O.27mmt (scratch error O.05mmt) to sample for making PD. Our new class of PD detected algorithm has also compared with previous PRPDA or Fuzzy algorithm, which has diagnose more conveniently by adding numerical values.

  • PDF

Magnetic Circular Dichroism Study of co Thin Films on Pd(111) Surface

  • Kim, Wookje;Kim, Wondong;Kim, Hyunjo;Kim, Jae-Young;Hoon Kho;Park, J.H.;Oh, S.J.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.169-169
    • /
    • 1999
  • We studied magnetic properties of co thin films deposited on Pd (111) surface, which attracted much attention recently due to the perpendicular magnetic anisotropy, using magnetic circular dichroism(MCD). Special attention was paid on the effect of Pd capping and interface roughness on the direction of magnetic easy axis, and for that purpose MCD signals for all Co thicknesses were measured with two different ways : in-plane and out-of-plane geometry. In case of bare Co films deposited on smooth Pd(111) surface, no MCD signal was observed under 4$\AA$ co thickness. At 4$\AA$ Co thickness, MCD signal at the out-of-plane geometry was observed, and for thicker Co films, only in-plane MCD signal was measured. This type of magnetic easy axis transition has been reported for other cases like Co/Pt system. The effect of 5$\AA$ Pd capping on these bare Co films made an remarkable change on the transition of magnetic easy axis. Out-of-plane MCD signals exists up to 20$\AA$ Co thickness, and disappears at 24$\AA$ Co thickness. In-plane MCD signals first appears at 10$\AA$ Co thickness and gradually increases up to 24$\AA$ Co thickness. Between 10$\AA$ and 20$\AA$ Co thickness, in-plane and out-of-plane MCD signal coexist. The formation of multi-domain structure or the existence of tilted magnetic easy axis is an possible scenario for such an interesting coexistence. The effect of interface roughness was also tested by measuring MCD signal on Co films deposited on un-annealed Pd(111) surface. Out-of-plane MCD signal was observed up to 8$\AA$ Co thickness and the anisotropy of MCD signal at 4$\AA$ Co thickness was very large with respect to that of Co film deposited on the smooth substrate. Above 8$\AA$ thickness, there exists only in-plane MCD signal. From above results, it was concluded that both Pd capping and interface roughness induce and reenforce the perpendicular magnetic anisotropy. The large perpendicular magnetic anisotropy of Co/Pd multilayer system made by sputtering method can be well understood from our results.

  • PDF

PD Signal Time-Frequency Map and PRPD Pattern Analysis of Nano SiO2 Modified Palm Oil for Transformer Insulation Applications

  • Arvind Shriram, R.K.;Chandrasekar, S.;Karthik, B.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.902-910
    • /
    • 2018
  • In recent times, development of nanofluid insulation for power transformers is a hot research topic. Many researchers reported the enhancement in dielectric characteristics of nano modified mineral oils. Considering the drawbacks of petroleum based mineral oil, it is necessary to understand the dielectric characteristics of nanofluids developed with natural ester based oils. Palm oil has better insulation characteristics comparable to mineral oil. However very few research reports is available in the area of nanofluids based on palm oil. Partial discharge (PD) is one of the major sources of insulation performance degradation of transformer oil. It is essential to understand the partial discharge(PD) characteristics by collecting huge data base of PD performance of nano modified palm oil which will increase its confidence level for power transformer application. Knowing these facts, in the present work, certain laboratory experiments have been performed on PD characteristics of nano $SiO_2$ modified palm oil at different electrode configurations. Influence of concentration of nano filler material on the PD characteristics is also studied. Partial discharge inception voltage, Phase resolved partial discharge (PRPD) pattern, PD signal time-frequency domain characteristics, PD signal equivalent timelength-bandwidth mapping, Weibull distribution statistical parameters of PRPD pattern, skewness, repetition rate and phase angle variations are evaluated at different test conditions. From the results of the experiments conducted, we came to understand that PD performance of palm oil is considerably enhanced with the addition of $nano-SiO_2$ filler at 0.01%wt and 0.05%wt concentration. Significant reduction in PD inception voltage, repetition rate, Weibull shape parameter and PD magnitude are noticed with addition of $SiO_2$ nanofillers in palm oil. These results will be useful for recommending nano modified palm oil for power transformer applications.

A Study on the Algorithm for Detection of Partial Discharge in GIS Using the Wavelet Transform

  • J.S. Kang;S.M. Yeo;Kim, C.H.;R.K. Aggarwal
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권4호
    • /
    • pp.214-221
    • /
    • 2003
  • In view of the fact that gas insulated switchgear (GIS) is an important piece of equipment in a substation, it is highly desirable to continuously monitor the state of equipment by measuring the partial discharge (PD) activity in a GIS, as PD is a symptom of an insulation weakness/breakdown. However, since the PD signal is relatively weak and the external noise makes detection of the PD signal difficult, it therefore requires careful attention in its detection. In this paper, the algorithm for detection of PD in the GIS using the wavelet transform (WT) is proposed. The WT provides a direct quantitative measure of the spectral content and dynamic spectrum in the time-frequency domain. The most appropriate mother wavelet for this application is the Daubechies 4 (db4) wavelet. 'db4', the most commonly applied mother wavelet in the power quality analysis, is very well suited to detecting high frequency signals of very short duration, such as those associated with the PD phenomenon. The proposed algorithm is based on utilizing the absolute sum value of coefficients, which are a combination of D1 (Detail 1) and D2 (Detail 2) in multiresolution signal decomposition (MSD) based on WT after noise elimination and normalization.