• 제목/요약/키워드: PD pulse

검색결과 157건 처리시간 0.025초

파라미터를 이용한 LDPE 절연열화 과정의 수면예측 (A LIFE PREDICTION OF LDPE DEGRADATION PROCESSING USING PARAMETERS)

  • 김성홍;서장수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.40-43
    • /
    • 2000
  • Our studies diagnose insulation degradation using the method of computer sensing system, which has the advantages of PD(partial discharge) and AE(acoustic emission) sensing system. To use advantages of these two methods can be used effectively to search for treeing location and PD in some materials. In analysis method of degradation, using statically operator such as the center of gravity (G), the gradient of the discharge distribution(C), we have analyzed for the prediction of life which we can be obtained the time, occurred of many pulse of small discharge amplitude.

  • PDF

1급 와동에서 상아질과 복합레진의 결합강도에 대한 중합방법의 효과 (THE EFFECT OF DIFFERENT CURING MODES ON COMPOSITE RESIN/DENTIN BOND STRENGTH IN CLASS ICAVITIES)

  • 백신영;조영곤;송병춘
    • Restorative Dentistry and Endodontics
    • /
    • 제33권5호
    • /
    • pp.428-434
    • /
    • 2008
  • 본 연구는 1급 복합레진 수복물에서 할로겐 광조사기를 이용한 4가지 중합방법이 상아질의 결합강도에 미치는 효과를 알아보기 위하여 시행하였다. 발거된 상 하악 대구치 20개의 교합면측 법랑질을 Diamond Wheel Saw를 이용하여 제거한 후 1급 와동을 형성하였다. 중합방법에 따라 파동지연 중합방법 (PD) 군, 연성 중합방법 (SS) 군, 파동 중합방법 (PC) 군, 지속 중합방법 (CC) 군의 4개 군으로 분류하고, Z250 복합레진을 각 군의 와동에 충전한 후 광조사하였다. 각 군의 시편을 주수하에 접착계면의 단면적이 $1mm^2$가 되도록 절단하여 막대모양의 시편을 제작하였고, 각 군당 20개의 시편을 사용하여 미세인장 결합강도를 측정하여 다음과 같은 결과를 얻었다. 1. PD 군은 PC 군과 CC 군보다 통계학적으로 더 높은 미세인장 결합강도를 나타내었다. 2. SS군의 미세인장 결합강도는 PC 군과 CC 군보다 높게 나타났으나, 통계학적으로 유의한 차이를 나타내지 않았다. 결론적으로, 1급 복합레진 수복물을 중합할 때 파동지연 중합방법과 연성 중합방법을 사용하여 중합속도를 조절함으로써 상아질과 복합레진의 결합강도를 개선할 수 있을 것으로 사료된다.

GIS 부분방전 신호와 도착 시간차 분석을 통한 PD발생 위치 추적 (Partial Discharge Position Tracking Method using a GIS Partial Discharge Signal and Arrival Time Difference)

  • 최문규;차한주
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1297-1301
    • /
    • 2013
  • This paper analyzes of PD occurrence position through an analysis of the arrival time difference between the GIS partial discharge signal. Because of GIS (Gas Insulated Switchgear) is a facility very important power equipment and as part of the equipment that make up the power system, the stabilization of the power industry, which accounted for 88.5% share of GIS substation in the form of a substation is an important equipment for power supply. In the situation where we are gradually expanding the need for preventive diagnosis in order to improve the efficiency of equipment management and failure prevention for Preventive diagnosis. In this paper as a method for extracting pre-defect of failure of GIS Apply the average value method of calculating the 5 times each using a pulse of the first time of the second pulse (${\Delta}t$) with an oscilloscope generation position PD(Partial Discharge). the results of GIS internal inspection, the partial discharge of the actual the position of the partial discharge was confirmed with an accuracy of about 82% of positions. Arrival time difference in the most effective manner if the partial discharge of GIS internal occurs by applying the averaging method and TOA(Time of arrival) method, the partial discharge occurs you through the measurement and analysis of PD signal occurs was confirmed in the experiment are presented and diagnostic methods location tracking.

Comparison of Partial Discharge Characteristics in SF6 Gas Under AC and DC

  • Jo, Hyang-Eun;Wang, Guoming;Kim, Sun-Jae;Kil, Gyung-Suk
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권6호
    • /
    • pp.323-327
    • /
    • 2015
  • In this paper, parameters related with partial discharge (PD) were analyzed in SF6 gas under AC and DC voltages. Three electrode systems (protrusion on conductor, protrusion on enclosure, and free particle) were fabricated to simulate PD defects in a gas-insulated switchgear (GIS). All electrode systems were filled with SF6 gas at 0.5 MPa. PD pulses were detected using an oscilloscope and a data acquisition (DAQ) based on IEC 60270. To analyze the PD characteristics under AC and DC voltages, parameters such as discharge inception voltage (DIV), discharge extinction voltage (DEV), pulse magnitude, repetition rate, and T-F map were compared. From the experimental results, PD was revealed to have different characteristics under AC and DC, and these results may be useful for diagnosis of power facilities operated under HVDC.

Application of SA-SVM Incremental Algorithm in GIS PD Pattern Recognition

  • Tang, Ju;Zhuo, Ran;Wang, DiBo;Wu, JianRong;Zhang, XiaoXing
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.192-199
    • /
    • 2016
  • With changes in insulated defects, the environment, and so on, new partial discharge (PD) data are highly different from the original samples. It leads to a decrease in on-line recognition rate. The UHF signal and pulse current signal of four kinds of typical artificial defect models in gas insulated switchgear (GIS) are obtained simultaneously by experiment. The relationship map of ultra-high frequency (UHF) cumulative energy and its corresponding apparent discharge of four kinds of typical artificial defect models are plotted. UHF cumulative energy and its corresponding apparent discharge are used as inputs. The support vector machine (SVM) incremental method is constructed. Examples show that the PD SVM incremental method based on simulated annealing (SA) effectively speeds up the data update rate and improves the adaptability of the classifier compared with the original method, in that the total sample is constituted by the old and new data. The PD SVM incremental method is a better pattern recognition technology for PD on-line monitoring.

전력케이블에서 교류전압과 진동파 전압을 이용한 부분방전 측정 (Partial Discharge Detection for the Power Cables using AC and Oscillating wave Voltage)

  • 김정태;김남준;이전선;구자윤
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권4호
    • /
    • pp.247-252
    • /
    • 1999
  • In this paper, in order to investigate availability of the OW-PD measurement method which has been proposed as an alternative of AC-PD measurement method to an after laying test and/or diagnosis for the power cable system, partial discharges owing to the needle-type defect integrated into the cable have been measured using AC and OW(Oscillating Wave) voltages. In the AC-PD measurement, the magnitude, phase and pulse number of partial discharges have been changed with the duration of voltage application, which can be analyzed through the relation with the process of the electrical tree initiation and propagation. In addition, the characteristics of partial discharges using OW voltage are appeared to be similar to those in case of AC-PD measurement and to be different with the shapes of electrical tree. From these results, it is concluded that the OW-PD measurement method is available to the tests for the cable system.

  • PDF

Setup of standard PD calibrator and its uncertainties

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.677-683
    • /
    • 2011
  • The present paper describes the setup of standard partial discharge calibrator for measuring partial discharge and estimating uncertainties. The standard PD calibrator was designed and set up, consisting of a digital pulse generator, capacitor modules, and a digital oscilloscope controlled by software developed in the laboratory. Using this software, averages of charges and rising times and their standard deviations in the measured pulses can also be calculated. The standard PD calibrator generates five types of pulses: single, double, random, oscillating, and long-rising. The coefficient sensitivities to estimate the uncertainties of pulses were extracted in the model circuit of the standard PD calibrator. The uncertainties of charges and rising times in pulses of the standard PD calibrator were estimated with single pulses. These values were 0.3%-1.4% in charges and 1.9%-7.0% in rising time; however, these values are lower than the limit values in IEC 60270.

문둥이박쥐(Eptesicus serotinus)의 생후 반향정위 발성 발달에 관한 연구 (Postnatal Development of Echolocation Vocalizations in the Serotine Bat, Eptesicus serotinus (Chiroptera: Vespertilionidae))

  • 정철운;한상훈;김성철;임춘우;차진열
    • 한국환경생태학회지
    • /
    • 제29권6호
    • /
    • pp.858-864
    • /
    • 2015
  • 문둥이박쥐(Eptesicus serotinus)의 생후 발성발달 특징을 파악하기 위하여 임신한 암컷 3개체로부터 총 4개체의 새끼 박쥐를 확보하여 발성변화를 분석하였다. 녹음 및 분석은 생후 1일부터 40일까지 수행하였으며, 펄스 지속시간(PD), 펄스 간격(PI), 최고 주파수(PF), 시작 주파수($F_{MAX}$), 종료 주파수($F_{MIN}$), 대역폭(BW)에 대하여 측정하였다. 새끼 박쥐는 생후 초기에 가장 다양한 패턴의 음성을 발산하였으며, 연령이 증가함에 따라서 점차 어미와 유사해졌다. PD와 PI는 연령이 증가할수록 감소하였으며, 반면 PF, $F_{MAX}$, $F_{MIN}$, BW는 증가하였다. PF, $F_{MAX}$, $F_{MIN}$, BW는 생후 10일에서 20일 사이에 가장 큰 변화가 확인되었으며, PD는 생후 30일에서 40일 사이에 가장 큰 변화가 확인되었다. 따라서 진동수의 발성과 관련이 있는 발성근육의 수축 능력은 생후 20일경 가장 발달하게 되며, 발성시간과 관련된 발성근육의 이완 능력은 생후 30일에서 40일 사이에 가장 발달하는 것으로 판단된다. 본 연구에 이용된 새끼 개체들은 생후 40일차에도 비행이 확인되지 않았으나 발성음은 어미와 유사하게 나타났다. 따라서 이러한 결과는 새끼 박쥐의 발성 발달은 비행행동 또는 비행과 관련된 근육의 발달을 필수적으로 동반하는 것은 아니라는 것을 보여주는 결과라 판단된다.

전이금속-Zeolite Y 촉매에서의 n-Butane 및 1-Butene의 반응 (Reactions of n-Butane and 1-Butene on Transition-Metal-Zeolite Y Catalysts)

  • 전학제;박상언
    • 대한화학회지
    • /
    • 제21권6호
    • /
    • pp.422-426
    • /
    • 1977
  • Zeolite Y를 합성하여 Co, Ni 및 Pd 이온으로 이온교환하고 수소기류중에서 환원함으로서 전이금속-Zeolite Y 촉매를 얻었다. 이들 Co-, Ni-, Pd-Y와 La-이온교환한 Y(LaY) 촉매에서의 1-butene 및 n-butane의 분해반응을 micro-catalytic pulse 방법으로 연구하였다. 1-Butene 분해반응에 있어서는 Ni-, Co-, Pd-Y 및 LaY 모두 높은 활성을 보여주었고 1-butene 분해반응에 대한 활성은 촉매상의 금속성분과는 큰 관계없이 산성 성분만이 주로 관련되고 있는것 같다. LaY에서는 $400^{\circ}C$에서 n-butane 분해반응에 대한 활성을 나타내지 않았으나 소량의 1-butene을 가함으로써 분해반응이 촉진되었다. Ni- 및 Pd-zeolite Y에서는 n-butane의 분해반응이 현저하게 일어났다. 분해반응에 대해서는 수소에 의한 환원온도가 높고 또 금속성분 함량이 많은 것이 활성이 높았다. n-butane 분해반응에 있어서는 금속성분에서의 butene으로의 탈수소반응이 첫 단계인 것으로 본다. Ni-Y에서는 1-butene과 수소 혼합반응물 및 n-butane의 분해생성물이 모두다 C_1$뿐이었다. n-butane은 Ni-Y에서는 butene으로 탈수소되고 이어서 C_1$으로 hydrocracking 되는 반응과정을 밟고 있다고 본다.

  • PDF

PSA를 이용한 PRPDA의 불명확성 개선에 대한 연구 (A study on the improvement of indefiniteness in PRPDA by use of PSA)

  • 이호근;김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.226-228
    • /
    • 2003
  • This paper deals with the improvement of indefiniteness in PRPDA(Phase Resolved Partial Discharge Analysis) through analyzing the relation between PRPDA and PSA(Pulse Sequence Analysis). For the analysis we adopted PD data from artificial defects in XLPE HV cable systems and performed PRPDA and PSA. As a results, we confirmed that PSA was more useful than PRPDA in classifying PD patterns with the degradation stages. Therefore, it is possible to improve the indefiniteness of PD pattern recognition using the relation between PRPDA and PSA.

  • PDF