• 제목/요약/키워드: PD measurement system

검색결과 116건 처리시간 0.03초

PD 및 SD를 이용한 배전용 EPDM애자의 절연성평가 (Estimation of EPDM Insulator in Distribution Line Using PO and SO Measurement)

  • 임장섭;송일근;이형구;천종욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.973-975
    • /
    • 1998
  • Many researchers make efforts to develop an effective material with anti-degradation property. Specially, the porcelain type insulator is required exchanging to polymer insulator according to the environmental consideration. In this paper, we have developed the estimation system using the PD & SD testing. Those approach has been very successful applied to the various practical insulator.

  • PDF

전자부품의 새로운 절연평가기법 연구 (A Study on the New Evaluation Method on Insulation of Electronic Components)

  • 길경석;송재용;문승보;차명수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.503-504
    • /
    • 2006
  • This paper describes a low-level partial discharge(PD) testing that has been accepted as a non-destructive test method on insulation performance of electronic components. A comparative PD analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards is carried out on high frequency switching transformers. The analysis shows that insulation degradation of the transformers under test progresses during the WVT. To avoid insulation degradation of the specimen, PD test has to be carried out at as low voltage as possible. In this study, the PD test on the transformers is performed in ranges from 50% to 70% of the test voltage specified in the WVT by measuring apparent charges below 1 pC. From the experimental results, it is expects that the low-level PD test is applicable for electronic components as a replacement of the WVT.

  • PDF

장시간 절연체 열화실험을 위한 부분방전측정기술 연구 (A Study on the Technology Measuring Partial Discharge for Long Term Aging Experiments of Insulation Materials)

  • 선종호;김광화;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권12호
    • /
    • pp.665-672
    • /
    • 2000
  • This paper described the measurement technology to analyze the partial discharge characteristics for long term aging of insulations. This system was consisted of high voltage generation and measurement part, PD detection part, digital conversion and signal processing part. We used the VXI system for digital conversion and signal processing part. In the digital conversion part, we studied the error of partial discharge magnitude and memory capacity for reading digital signal with the sampling rate. In the signal processing part, we showed the program algorithm to count pulses and read peak values of partial discharge. The allowable minimum sampling rate of digizer was decided to 250kS/s through analyzing test. We confirmed that this system was very useful in the study of $\phi-q-n$ characteristics of long term PD experiments with specimens being consisted of internal void defects and CIGRE II electrodes.

  • PDF

전력 케이블에서 발생되는 방전 신호의 분포패턴에 관한 특성 분석 (Characteristic Analysis on the Distribution Pattern of Discharge Signals Generated in the Power Cable)

  • 소순열;홍경진;정우성;임장섭;이진;이준웅;김태성
    • 한국전기전자재료학회논문지
    • /
    • 제11권11호
    • /
    • pp.1035-1042
    • /
    • 1998
  • After the 1990's, a computer-aided partial discharge(PD) measurement system was referred in part of aging diagnosis using digital signal processing as the new technology has been studied. The PD patterns and relevant information for pattern recognition are discussed in PD research area, because discharge quantity(q), the number of discharge pulse(n) and the applied boltage phase($\varphi$) was combined with the system information of the aging state. This paper investigates the discharge phase and quantity, as well as the number of discharge(n) with regard to discharge signals generated in power cable. therefore, according to characteristic analysis on the distribution of $\varphi$, q and n, it is able to apply in the aging analysis of power cable which visual observation is impossible and distribution change of discharge signals offers much information for risk degree on aging progress of insulation materials.

  • PDF

GIS 변전소의 극초단파대역 잡음환경 측정 (Measurement of Ultra-high Frequency(UHF) noise spectra)

  • 임재섭;박기준;구선근;윤진열;정길조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1768-1769
    • /
    • 2003
  • 가스절연개폐장치(Gas-insulated Switchgear, GIS)의 예방진단 기술의 한 방법으로, 극 초단파(Ultrahigh frequency) 부분방전(Partial discharge) 센서를 사용하여 결함의 유무를 판별할 수 있다. 그러나 UHF PD 센서에는 부분방전신호 이외에 외부 잡음의 유입 가능성이 크다. 따라서 본 논문에서는 PD 센서 주변 잡음을 측정하기 위하여 $0{\sim}2$ GHz 의주파수영역에서 산지, 도심 지역의 변전소의 위치에 따른 외부 잡음을 측정하였다. 주파수 대역별로 FM 방송, TV 방송, 이동전화, 등의 신호를 판별하였다.

  • PDF

광섬유 Mach-Zehnder 간섭계를 이용한 부분방전 초음파 검출특성 (Ultrasonic-detecting Characteristics by Partial Discharge using the Fiber Mach-Zehnder Interferometerin Insulating Oil)

  • 심승환;이광식;이상훈;김달우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.325-328
    • /
    • 2002
  • The partial-discharge(PD) is accompanied by physical and chemical phenomena, such as heat, light, noise, gas, chemical transformation, electric current, and electromagnetic radiation. The PD can be detected by measuring one of these changes. Although some techniques are employed in this purpose, several obstacles interfere with an on-line measurement. Now a fiber-optic sensor for detecting ultrasonics is suggested for the on line measurement system with high accuracy. In this paper, an optical fiber sensor utilizing the principal of Mach-Zehnder interferometer was proposed to detect the discharge signal.

  • PDF

자이로센서를 이용한 특발성 파킨슨병 환자와 정상인의 손가락 벌렸다 오므리기 동작의 측정과 비교 (Measurement and Comparison of Finger Tapping Movement in Patients with Idiopathic Parkinson's Disease and Normal Subjects using Gyrosensor)

  • 김지원;권유리;이재호;엄광문;권도영;고성범;박병규;홍정화
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권3호
    • /
    • pp.240-244
    • /
    • 2010
  • The purpose of this study is to compare finger tapping (FT) movement of patients with Parkinson's disease (PD) with normal subjects. A gyrosensor system was used for the measurement of FT movement, because it provides angular velocity free from the gravitational artifact and it can be used during clinical FT test listed in unified PD rating scale (UPDRS). Forty PD patients (age: 65.7 ${\pm}$ 11.1 yrs, H&Y stage:2.3 ${\pm}$ 0.5), 14 age-matched elderly subjects (65${\pm}$3.9 yrs) and 17 healthy young subjects (24${\pm}$2.1yrs) participated in this study. Angular velocity of finger tapping movement was measured in both right and left index finger. As quantitative measures, root-mean-squared (RMS) angular velocity, RMS angle, peak power and total power were used. ANOVA showed that all measures were significantly different among three groups (p<0.001) in all quantitative measures. Post-hoc test revealed that all quantitative measures except peak power in patients with PD were significantly smaller than in both healthy elderly and young subjects (p<0.01). This suggests that the measures developed in this study can distinguish patients with PD from normal subjects.

Verification of Extended Source-To-Imager Distance (SID) Correction for Portal Dosimetry

  • Son, Jaeman;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제29권4호
    • /
    • pp.137-142
    • /
    • 2018
  • This study aimed to evaluate and verify a process for correcting the extended source-to-imager distance (SID) in portal dosimetry (PD). In this study, eight treatment plans (four volumetric modulated arc therapy and four intensity-modulated radiation therapy plans) at different treatment sites and beam energies were selected for measurement. A Varian PD system with portal dose image prediction (PDIP) was used for the measurement and verification. To verify the integrity of the plan, independent measurements were performed with the MapCHECK device. The predicted and measured fluence were evaluated using the gamma passing rate. The output ratio was defined as the ratio of the absolute dose of the reference SID (100 cm) to that of each SID (120 cm or 140 cm). The measured fluence for each SID was absolutely and relatively compared. The average SID output ratios were 0.687 and 0.518 for 120 SID and 140 SID, respectively; the ratio showed less than 1% agreement with the calculation obtained by using the inverse square law. The resolution of the acquired EPIDs were 0.336, 0.280, and 0.240 for 100, 120, and 140 SID, respectively. The gamma passing rates with PD and MapCHECK exceeded 98% for all treatment plans and SIDs. When autoalignment was performed in PD, the X-offset showed no change, and the Y-offset decreased with increasing SID. The PD-generated PDIP can be used for extended SID without additional correction.

하이브리드 AMB를 포함한 초전도 플라이휠 에너지 저장장치의 실험평가 (Experimental Evaluation of Superconductor Flywheel Energy Storage System with Hybrid Type Active Magnetic Bearing)

  • 이정필;김한근;한상철
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.195-202
    • /
    • 2012
  • In this paper, we designed Active Magnetic Bearing (AMB) for large scale Superconductor Flywheel Energy Storage System (SFESS) and PD controller for AMB. And we experimentally evaluated SFESS including hybrid type AMB. The radial AMB was designed to provide force slew rate that was sufficient for the unbalance disturbances at the maximum operating speed. The thrust AMB is a hybrid type where a permanent magnet carries the weight of the flywheel and an electromagnetic actuator generates the dynamic control force. We evaluated the design performance of the manufactured AMB through comparison of FEM analysis and the results of experimental force measurement. In order to obtain gains of PD controller and design a notch filter, the system identification was performed through measuring frequency response including dynamics for the AMBs, a power amp and a sensor using a sine swept test method after levitating the flywheel. Through measuring the current input of the AMBs and the orbit of a flywheel according to rotational speed, we verified excellent control performance of the AMBs with small amount current for the large scale SFESS.

발전기 고정자 권선의 운전중 부분방전 측정에 의한 절연진단 시스템 개발 (Development of Insulation Diagnosis System by On-Line Partial Discharge Measurement of Generator Stator Windings)

  • 신병철;황돈하;김용주;김정우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1025-1027
    • /
    • 1999
  • Recently, many researches on a diagnosis of stator winding insulation of large generators are reported. They mostly utilize a trend analysis of Partial Discharge (PD). In this paper, a novel on-line monitoring system for an insulation diagnosis is proposed. This system obtains the parameters such as Maximum Partial Discharge Magnitude (QM), Normalized Quantity Number (NQN) and Dynamic Stagnation Voltage (DSV) by continuous on-line monitoring of winding insulation. It is capable of diagnosing the insulation condition by analyzing the trend of PD and utilizing the database built by the system.

  • PDF