• 제목/요약/키워드: PD Test

검색결과 463건 처리시간 0.026초

세라믹 커플러를 이용한 고전압회전기 고정자권선의 On-line 및 off-line 부분방전 특성 시험 및 분석 (Analysis and lest of On-line and off-line PD Testing for High Voltage Rotating Machines Stator Windings using Ceramic Coupler)

  • 오봉근;김현일;강성화;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제20권10호
    • /
    • pp.895-900
    • /
    • 2007
  • Partial discharge(PD) test can be performed either when the rotating machine is not operating(off-line) or during normal machine operation(on-line). This paper presents an on-line and off-line PD test on a large hydro-generator and induction motor using the same PD acquisition system(PDAS) and ceramic coupler(CC) sensor. PD signal characteristics of CC sensor proved similar with that of epoxy mica coupler(EMC) sensor as a results of PD test for simulated defect winding and frequency response test. A comparison of on-line and off-line PD test for PD characteristic parameters-phase resolved PD(PRPD), maximum PD value(Qmax) and PD occurrence energy(POE)-indicated that on-line PD test could reliably and effectively diagnose insulation conditions which were verified by off-line PD test.

Study on Ginseng Protopanaxadiol and Protopanaxatriol Saponins-Induced Antinociception

  • Shin, Young-Hee;Kim, Seok-Chang;Han, Ji-Won;Kim, Dae-Hoon;Han, Sang-Sub;Shin, Dong-Ho;Nah, Seung-Yeol
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제1권2호
    • /
    • pp.143-149
    • /
    • 1997
  • We studied the effects of ginseng protopanaxadiol (PD) and protopanaxatriol (PT) saponins on the analgesia using several pain tests such as writhing, formalin, and tail-flick test. Using mouse, pretreatment of PD or PT saponins (i.p.) induced inhibition of abdominal constrictions caused by 0.9% acetic acid administration(i.p.). The $AD_{50}$ was around 27 (17-43) mg/kg for PD and 13.5 (3-61) mg/kg for PT saponins in writhing test. Both PD and PT saponins also showed the inhibition of bitings and lickings of hindpaw after administration of 1% formalin. In particular, both PD and PT saponins showed analgesic effects on second phase of pain. The $AD_{50}$ was 44.5 (26-76) mg/kg for PD and 105 (55-200) mg/kg for PT saponins in second phase of formalin test. For first phase pain inhibition by PD or PT saponins, they were required higher concentrations. However, PD saponins showed weak analgesic effects in tail-flick test with high concentration. In conclusion, we found that both PD and PT saponins have the analgesic effects in writhing test and second phase of pain in formalin test. These results suggest that both PD and PT saponins inhibit neurogenic or tonic pain rather than acute pain.

  • PDF

전자부품의 새로운 절연평가기법 연구 (A Study on the New Evaluation Method on Insulation of Electronic Components)

  • 길경석;송재용;문승보;차명수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.503-504
    • /
    • 2006
  • This paper describes a low-level partial discharge(PD) testing that has been accepted as a non-destructive test method on insulation performance of electronic components. A comparative PD analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards is carried out on high frequency switching transformers. The analysis shows that insulation degradation of the transformers under test progresses during the WVT. To avoid insulation degradation of the specimen, PD test has to be carried out at as low voltage as possible. In this study, the PD test on the transformers is performed in ranges from 50% to 70% of the test voltage specified in the WVT by measuring apparent charges below 1 pC. From the experimental results, it is expects that the low-level PD test is applicable for electronic components as a replacement of the WVT.

  • PDF

Physical Developer(PD)의 신뢰성 테스트(reagent reliability test)를 위한 타겟물질 탐색과 TWEEN® 20 기반 PD 작업용액의 보관기간에 관한 연구 (Identifying the potential target substance of physical developer (PD) for reagent reliability test and a study on storage period of TWEEN® 20 based PD working solution)

  • 안수정;이예진;유제설
    • 분석과학
    • /
    • 제36권3호
    • /
    • pp.113-120
    • /
    • 2023
  • Physical developer (PD)는 젖었거나 탄화된 종이의 지문, 그리고 매우 오래된 종이의 지문까지도 현출할 수 있는 효과적인 기법이다. 하지만, 어떤 물질과 반응하는지 밝혀지지 않았고 작업용액의 보관기간에 따른 최적화 시점 또한 알려지지 않았다. PD를 좀 더 효과적으로 활용하기 위해서는 이 두가지 이슈를 해결해야 한다. 본 연구에서는 이를 위해 지문을 구성하는 것으로 알려진 수용성 물질 7가지와 지용성 물질 5가지로 spot test를 하였고 그 중 palmitic acid와 lysine의 혼합물이 PD와 가장 강하게 반응한다는 것을 알아내었다. 또한, 1,2-indanedione/zinc (1,2-IND/Zn) 용액을 처리하여 lysine이 용해되지 않았음을 확인하였다. 이 두 물질의 혼합물을 PD 작업용액의 지문 현출 성능을 시험하기 위한 신뢰성 테스트(reagent reliability test)의 타겟물질로 활용하여 TWEEN® 20 기반 PD 작업용액의 보관기간에 따른 최적화 시점을 확인하였다. 그 결과, 14일이 지났을 때 가장 뛰어난 결과를 나타냈으며 그 이후부터는 반응이 점점 약해졌다.

수력발전기 고정자 노후권선의 모의결함 시편에 대한 부분방전 파라미터 변화 분석 (Analysis of Parameters on Partial Discharges from Insulation Defects of used Hydro Generator Stator Windings)

  • 오봉근;김현일;강성화;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제20권7호
    • /
    • pp.645-649
    • /
    • 2007
  • Partial discharge(PD) test for simulated insulation defects of used hydro generator stator winding was conducted to analyze the PD Parameters. Simulated insulation defects are classified by 5 types corona, slot, internal, multi and aging defect. Phase resolved partial discharge, statistical parameter (skewness, kurtosis), PD magnitude as a function of the test voltage(Q-V curve) and PD magnitude change under test voltage for 2 minutes are used as PD parameters. The analysis of PD parameters by 4 types are proved to be useful methods. In particular, PD parameter characteristics of aging defect could help to assess the aging condition of stator winding because aging defect has more weak insulation strength than other insulation defects : PD distribution is wide and flat, PD rises rapidly near $0^{\circ}\;and\;180^{\circ}$ and Q-V curve rises sharply and then gently drops.

Ti-Pd계 합금의 미세조직변화에 따른 부식거동 (Corrosion Behavior of Ti-Pd System Alloys by Microstructural changes)

  • 차성수;곽동주;남상용
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.9-16
    • /
    • 2008
  • The surface microstructural changes, mechanical properties and corrosion resistance of Ti-Pd alloys for dental biomaterials have been investigated. Ti, Ti-Pd alloys were melted in arc furnace and the corrosion resistance of Ti-Pd alloys was evaluated by anodic polarization test. The surface microstructural changes and mechanical properties of Ti-Pd alloys were analysed by scanning electron microscope and Vickers micro-hardness tester. The vickers hardnees of pure Ti improved by addition of Pd but Ti-25Pd alloy showed decreasing compared with Ti-15Pd. And anodic polarization and potentiostatic test were conducted in 5% HCl to quantify the resistance to corrosion with the addition of Pd, There was no significant difference in corrosion resistance between pure Ti, Ti-5Pd and Ti-15Pd alloy. However, Ti-25Pd alloy showed decreasing compared with pure Ti in corrosion resistance. From these results, it was concluded that newly formulated Ti-15Pd experimental alloy have adequate hardness and high corrosion resistance, and this alloy is promising candidate for a successful dental casting alloy.

  • PDF

시험소 부분방전 측정시스템(ERA)의 소급성검토 (Review of the tracebility of ERA PD measuring system in test laboratory)

  • 허종철;강영식;김위영;오창수;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1969-1971
    • /
    • 2004
  • For evaluation of partial discharge performances of electrical power appratus such as Insulator, circuit breaker and transformer and so on, Partial discharge measuring system(ERA) consisted of PD detector including amplifier, coupling capacitor, PD calibrator and voltage divider are used PD measuring system is very important factor which affect the test result and show reliability of test result in test laboratory, In this paper, we describe tracebility and uncertainty of PD measuring system in test laboratory based on IEC 60270.

  • PDF

ERA 부분방전 측정시스템의 측정불확도개선 (Measurement uncertainty Improvement of ERA PD measuring system in teat laboratory)

  • 허종철;김위영;김석수;오창수;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1509-1510
    • /
    • 2006
  • ERA PD measuring system has been using for partial discharge evaluation of power appratus in test laboratories. So, the measurement uncertainty of PD measuring system (ERA), such as PD pulse calibrator rise and fall time, sacle factor(k) and linearity, transfer impedance etc, is very important factor of test result in test laboratory. In this paper, we describe tracebility and uncertainty improvement of PD measuring system in test laboratory based on IEC 60270.

  • PDF

고전압회전기 고정자권선 운전중 부분방전진단시스템의 현장적용사례 연구 (A Case Study of On-line PD Measuring System on the Stator Winding for High Voltage Rotating Machine)

  • 오봉근;강동식;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.109-109
    • /
    • 2010
  • On-line partial discharge(PD) diagnostic system is the most prominent systems to diagnose insulation condition for the high voltage rotating machines. Partial discharge measuring system(PDMS) series with ceramic coupler(PD detecting sensor) installed hydro generator and high voltage motor have been measured the PD data for many years. The trend of PD magnitude in the on-line PD system increased for some machines. These machines showed a same result in the conventional off-line PD test and PD magnitude decreased after stator winding insulation cleaning. This case study show that PDMS has been proved to be good results by comparing PD magnitude with on-line and off-line PD test and it is important to plan the maintenance project for the hydro generator stator winding because PD value was decreased after insulation cleaning.

  • PDF

Partial Discharge Pattern Recognition of Cast Resin Current Transformers Using Radial Basis Function Neural Network

  • Chang, Wen-Yeau
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.293-300
    • /
    • 2014
  • This paper proposes a novel pattern recognition approach based on the radial basis function (RBF) neural network for identifying insulation defects of high-voltage electrical apparatus arising from partial discharge (PD). Pattern recognition of PD is used for identifying defects causing the PD, such as internal discharge, external discharge, corona, etc. This information is vital for estimating the harmfulness of the discharge in the insulation. Since an insulation defect, such as one resulting from PD, would have a corresponding particular pattern, pattern recognition of PD is significant means to discriminate insulation conditions of high-voltage electrical apparatus. To verify the proposed approach, experiments were conducted to demonstrate the field-test PD pattern recognition of cast resin current transformer (CRCT) models. These tests used artificial defects created in order to produce the common PD activities of CRCTs by using feature vectors of field-test PD patterns. The significant features are extracted by using nonlinear principal component analysis (NLPCA) method. The experimental data are found to be in close agreement with the recognized data. The test results show that the proposed approach is efficient and reliable.