• Title/Summary/Keyword: PD Test

Search Result 461, Processing Time 0.036 seconds

Analysis and lest of On-line and off-line PD Testing for High Voltage Rotating Machines Stator Windings using Ceramic Coupler (세라믹 커플러를 이용한 고전압회전기 고정자권선의 On-line 및 off-line 부분방전 특성 시험 및 분석)

  • Oh, Bong-Keun;Kim, Hyun-Il;Kang, Seong-Hwa;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.895-900
    • /
    • 2007
  • Partial discharge(PD) test can be performed either when the rotating machine is not operating(off-line) or during normal machine operation(on-line). This paper presents an on-line and off-line PD test on a large hydro-generator and induction motor using the same PD acquisition system(PDAS) and ceramic coupler(CC) sensor. PD signal characteristics of CC sensor proved similar with that of epoxy mica coupler(EMC) sensor as a results of PD test for simulated defect winding and frequency response test. A comparison of on-line and off-line PD test for PD characteristic parameters-phase resolved PD(PRPD), maximum PD value(Qmax) and PD occurrence energy(POE)-indicated that on-line PD test could reliably and effectively diagnose insulation conditions which were verified by off-line PD test.

Study on Ginseng Protopanaxadiol and Protopanaxatriol Saponins-Induced Antinociception

  • Shin, Young-Hee;Kim, Seok-Chang;Han, Ji-Won;Kim, Dae-Hoon;Han, Sang-Sub;Shin, Dong-Ho;Nah, Seung-Yeol
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.1 no.2
    • /
    • pp.143-149
    • /
    • 1997
  • We studied the effects of ginseng protopanaxadiol (PD) and protopanaxatriol (PT) saponins on the analgesia using several pain tests such as writhing, formalin, and tail-flick test. Using mouse, pretreatment of PD or PT saponins (i.p.) induced inhibition of abdominal constrictions caused by 0.9% acetic acid administration(i.p.). The $AD_{50}$ was around 27 (17-43) mg/kg for PD and 13.5 (3-61) mg/kg for PT saponins in writhing test. Both PD and PT saponins also showed the inhibition of bitings and lickings of hindpaw after administration of 1% formalin. In particular, both PD and PT saponins showed analgesic effects on second phase of pain. The $AD_{50}$ was 44.5 (26-76) mg/kg for PD and 105 (55-200) mg/kg for PT saponins in second phase of formalin test. For first phase pain inhibition by PD or PT saponins, they were required higher concentrations. However, PD saponins showed weak analgesic effects in tail-flick test with high concentration. In conclusion, we found that both PD and PT saponins have the analgesic effects in writhing test and second phase of pain in formalin test. These results suggest that both PD and PT saponins inhibit neurogenic or tonic pain rather than acute pain.

  • PDF

A Study on the New Evaluation Method on Insulation of Electronic Components (전자부품의 새로운 절연평가기법 연구)

  • Kil, Gyung-Suk;Snog, Jae-Yong;Moon, Seung-Bo;Cha, Myung-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.503-504
    • /
    • 2006
  • This paper describes a low-level partial discharge(PD) testing that has been accepted as a non-destructive test method on insulation performance of electronic components. A comparative PD analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards is carried out on high frequency switching transformers. The analysis shows that insulation degradation of the transformers under test progresses during the WVT. To avoid insulation degradation of the specimen, PD test has to be carried out at as low voltage as possible. In this study, the PD test on the transformers is performed in ranges from 50% to 70% of the test voltage specified in the WVT by measuring apparent charges below 1 pC. From the experimental results, it is expects that the low-level PD test is applicable for electronic components as a replacement of the WVT.

  • PDF

Identifying the potential target substance of physical developer (PD) for reagent reliability test and a study on storage period of TWEEN® 20 based PD working solution (Physical Developer(PD)의 신뢰성 테스트(reagent reliability test)를 위한 타겟물질 탐색과 TWEEN® 20 기반 PD 작업용액의 보관기간에 관한 연구)

  • Soo-Jeong Ahn;Ye-jin Lee;Je-Seol Yu
    • Analytical Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.113-120
    • /
    • 2023
  • Physical developer (PD) is an effective technique that can develop fingerprints even on wet or very old paper. However, it has not been known which substance reacts with PD. Also, the timing of optimization according to the storage period of the PD working solution has not been known. The present research has done a spot test with 7 eccrine components and 5 sebaceous components that known as fingerprint components and figured out the mixture of palmitic acid and lysine gave the strongest positive reaction. Also, paper treated with PD was treated in 1,2-indanedione/zinc (1,2-IND/Zn) working solution and showed lysine was not dissolved in water. To find out the timing of optimization according to the storage period of the TWEEN® 20 based PD working solution, the mixture of palmitic acid and lysine was used for the target of reagent reliability test. As the result, working solution of 14 days storage period showed better result than other working solutions.

Analysis of Parameters on Partial Discharges from Insulation Defects of used Hydro Generator Stator Windings (수력발전기 고정자 노후권선의 모의결함 시편에 대한 부분방전 파라미터 변화 분석)

  • Oh, Bong-Keun;Kim, Hyun-Il;Kang, Seong-Hwa;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.7
    • /
    • pp.645-649
    • /
    • 2007
  • Partial discharge(PD) test for simulated insulation defects of used hydro generator stator winding was conducted to analyze the PD Parameters. Simulated insulation defects are classified by 5 types corona, slot, internal, multi and aging defect. Phase resolved partial discharge, statistical parameter (skewness, kurtosis), PD magnitude as a function of the test voltage(Q-V curve) and PD magnitude change under test voltage for 2 minutes are used as PD parameters. The analysis of PD parameters by 4 types are proved to be useful methods. In particular, PD parameter characteristics of aging defect could help to assess the aging condition of stator winding because aging defect has more weak insulation strength than other insulation defects : PD distribution is wide and flat, PD rises rapidly near $0^{\circ}\;and\;180^{\circ}$ and Q-V curve rises sharply and then gently drops.

Corrosion Behavior of Ti-Pd System Alloys by Microstructural changes (Ti-Pd계 합금의 미세조직변화에 따른 부식거동)

  • Cha, Sung-Soo;Kwak, Dong-Ju;Nam, Sang-Yong
    • Journal of Technologic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.9-16
    • /
    • 2008
  • The surface microstructural changes, mechanical properties and corrosion resistance of Ti-Pd alloys for dental biomaterials have been investigated. Ti, Ti-Pd alloys were melted in arc furnace and the corrosion resistance of Ti-Pd alloys was evaluated by anodic polarization test. The surface microstructural changes and mechanical properties of Ti-Pd alloys were analysed by scanning electron microscope and Vickers micro-hardness tester. The vickers hardnees of pure Ti improved by addition of Pd but Ti-25Pd alloy showed decreasing compared with Ti-15Pd. And anodic polarization and potentiostatic test were conducted in 5% HCl to quantify the resistance to corrosion with the addition of Pd, There was no significant difference in corrosion resistance between pure Ti, Ti-5Pd and Ti-15Pd alloy. However, Ti-25Pd alloy showed decreasing compared with pure Ti in corrosion resistance. From these results, it was concluded that newly formulated Ti-15Pd experimental alloy have adequate hardness and high corrosion resistance, and this alloy is promising candidate for a successful dental casting alloy.

  • PDF

Review of the tracebility of ERA PD measuring system in test laboratory (시험소 부분방전 측정시스템(ERA)의 소급성검토)

  • Heo, J.C.;Kang, Y.S.;Kim, W.Y.;Oh, C.S.;Park, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1969-1971
    • /
    • 2004
  • For evaluation of partial discharge performances of electrical power appratus such as Insulator, circuit breaker and transformer and so on, Partial discharge measuring system(ERA) consisted of PD detector including amplifier, coupling capacitor, PD calibrator and voltage divider are used PD measuring system is very important factor which affect the test result and show reliability of test result in test laboratory, In this paper, we describe tracebility and uncertainty of PD measuring system in test laboratory based on IEC 60270.

  • PDF

Measurement uncertainty Improvement of ERA PD measuring system in teat laboratory (ERA 부분방전 측정시스템의 측정불확도개선)

  • Heo, Jong-Cheol;Kim, We-Young;Kim, Seok-Sou;Oh, Chang-Soo;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1509-1510
    • /
    • 2006
  • ERA PD measuring system has been using for partial discharge evaluation of power appratus in test laboratories. So, the measurement uncertainty of PD measuring system (ERA), such as PD pulse calibrator rise and fall time, sacle factor(k) and linearity, transfer impedance etc, is very important factor of test result in test laboratory. In this paper, we describe tracebility and uncertainty improvement of PD measuring system in test laboratory based on IEC 60270.

  • PDF

A Case Study of On-line PD Measuring System on the Stator Winding for High Voltage Rotating Machine (고전압회전기 고정자권선 운전중 부분방전진단시스템의 현장적용사례 연구)

  • Oh, Bong-Keun;Kang, Dong-Sik;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.109-109
    • /
    • 2010
  • On-line partial discharge(PD) diagnostic system is the most prominent systems to diagnose insulation condition for the high voltage rotating machines. Partial discharge measuring system(PDMS) series with ceramic coupler(PD detecting sensor) installed hydro generator and high voltage motor have been measured the PD data for many years. The trend of PD magnitude in the on-line PD system increased for some machines. These machines showed a same result in the conventional off-line PD test and PD magnitude decreased after stator winding insulation cleaning. This case study show that PDMS has been proved to be good results by comparing PD magnitude with on-line and off-line PD test and it is important to plan the maintenance project for the hydro generator stator winding because PD value was decreased after insulation cleaning.

  • PDF

Partial Discharge Pattern Recognition of Cast Resin Current Transformers Using Radial Basis Function Neural Network

  • Chang, Wen-Yeau
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.293-300
    • /
    • 2014
  • This paper proposes a novel pattern recognition approach based on the radial basis function (RBF) neural network for identifying insulation defects of high-voltage electrical apparatus arising from partial discharge (PD). Pattern recognition of PD is used for identifying defects causing the PD, such as internal discharge, external discharge, corona, etc. This information is vital for estimating the harmfulness of the discharge in the insulation. Since an insulation defect, such as one resulting from PD, would have a corresponding particular pattern, pattern recognition of PD is significant means to discriminate insulation conditions of high-voltage electrical apparatus. To verify the proposed approach, experiments were conducted to demonstrate the field-test PD pattern recognition of cast resin current transformer (CRCT) models. These tests used artificial defects created in order to produce the common PD activities of CRCTs by using feature vectors of field-test PD patterns. The significant features are extracted by using nonlinear principal component analysis (NLPCA) method. The experimental data are found to be in close agreement with the recognized data. The test results show that the proposed approach is efficient and reliable.