고전압회전기 고정자권선 운전중 부분방전진단시스템의 현장적용사례 연구 (A Case Study of On-line PD Measuring System on the Stator Winding for High Voltage Rotating Machine)

  • 오봉근;강동식;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.109-109
    • /
    • 2010
  • On-line partial discharge(PD) diagnostic system is the most prominent systems to diagnose insulation condition for the high voltage rotating machines. Partial discharge measuring system(PDMS) series with ceramic coupler(PD detecting sensor) installed hydro generator and high voltage motor have been measured the PD data for many years. The trend of PD magnitude in the on-line PD system increased for some machines. These machines showed a same result in the conventional off-line PD test and PD magnitude decreased after stator winding insulation cleaning. This case study show that PDMS has been proved to be good results by comparing PD magnitude with on-line and off-line PD test and it is important to plan the maintenance project for the hydro generator stator winding because PD value was decreased after insulation cleaning.

  • PDF

PD Occurrence Characteristics according to Voltage and Time in Solid Insulator

  • Park, Sung-Hee;Shin, Dal-Woo;Lim, Kee-Joe;Park, Young-Guk;Kang, Sung-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권1호
    • /
    • pp.10-14
    • /
    • 2003
  • The occurrence of partial discharge (PD) in solid dielectrics is very harmful because it leads to the deterioration of insulation by electrical, chemical, and thermal reactions as a combined action of the discharged ions bombarding the surface and by the action of chemical compounds that are formed by the discharge. Consequently, if any defects are present in the solid insulation system, performance decreases until the system breaks down. Therefore, removing or suppressing the defect is very important. Voids are a typical defect in the solid insulation system and are very harmful because they deteriorate insulation. As a basic step, studying the properties of PD in voids is important because an accurate knowledge of these properties is required to estimate the deterioration of voids. In this paper, the correlation between the size of voids and internal PD is discussed as a function of the time of the applied voltage and its magnitude. Magnitude, repetition rate, average discharge power, and average discharge current of PD in specimens with large voids were found to be larger than the others in this experiment. The smaller specimens had voids when the magnitude and number of PDs were reduced.

저밀도 폴리에틸렌에서 부시형 전기트리에 수반되는 부분방전 펄스의 특성 (Properties of PD Pulses Accompanying with Bush-type Tree in LDPE)

  • 강성화;박영국;정수현;이광우;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제11권12호
    • /
    • pp.1055-1059
    • /
    • 1998
  • The correlation between the propagation of electrical tree and distributions of partial discharge(PD) pulses accompanying with electrical tree of bush type in low density polyethylene were discussed. We measured the growth of electrical tree by using optical microscope and PD data simultaneously. The PD data detected and analyzed were PD magnitude, repetition rate, average discharge power, average phase angle, and $\psi$-q-n distribution pattern. The average discharge power and repetition rate of PD had good linear relation with area of tree. Repetition rate and peak discharge magnitude and width of discharge phase angle increased with the tree.

  • PDF

수력발전기 고정자 노후권선의 모의결함 시편에 대한 부분방전 파라미터 변화 분석 (Analysis of Parameters on Partial Discharges from Insulation Defects of used Hydro Generator Stator Windings)

  • 오봉근;김현일;강성화;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제20권7호
    • /
    • pp.645-649
    • /
    • 2007
  • Partial discharge(PD) test for simulated insulation defects of used hydro generator stator winding was conducted to analyze the PD Parameters. Simulated insulation defects are classified by 5 types corona, slot, internal, multi and aging defect. Phase resolved partial discharge, statistical parameter (skewness, kurtosis), PD magnitude as a function of the test voltage(Q-V curve) and PD magnitude change under test voltage for 2 minutes are used as PD parameters. The analysis of PD parameters by 4 types are proved to be useful methods. In particular, PD parameter characteristics of aging defect could help to assess the aging condition of stator winding because aging defect has more weak insulation strength than other insulation defects : PD distribution is wide and flat, PD rises rapidly near $0^{\circ}\;and\;180^{\circ}$ and Q-V curve rises sharply and then gently drops.

Analysis of Insulation Quality in Large Generator Stator Windings

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho;Kim, Byong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권3호
    • /
    • pp.384-390
    • /
    • 2011
  • To evaluate the condition of stator winding insulation in generators that have been operated for a long period of time, diagnostic tests were performed on the stator bars of a 500 MW, 22 kV generator under accelerated thermal and electrical aging procedures. The tests included measurements of AC current (${\Delta}I$), dissipation factor ($tan{\delta}$), partial discharge (PD) magnitude, and capacitance (C). In addition, the AC current test was performed on the stator winding of a 350 MW, 24 kV generator under operation to confirm insulation deterioration. The values of ${\Delta}I$, ${\Delta}tan{\delta}$, and PD magnitude in one stator bar indicated serious insulation deterioration. In another stator bar, the ${\Delta}I$ measurements showed that the insulation was in good condition, whereas the values of ${\Delta}tan{\delta}$ and PD magnitude indicated an incipient stage of insulation deterioration. Measurements of ${\Delta}I$ and PD magnitude in all three phases (A, B, C) of the remaining generator stator windings showed that they were in good condition, although the ${\Delta}tan{\delta}$ measurements suggested that the condition of the insulation should be monitored carefully. Overall analysis of the results suggested that the generator stator windings were in good condition. The patterns of PD magnitude in all three phases (A, B, C) were attributed to internal discharge.

운전중 부분방전 진단시스템을 위한 복합 잡음제거 기법 (A Complex Noise Suppression Algorithm for On-line Partial Discharge Diagnosis Systems)

  • 이상화;윤영우;추영배;강동식
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.342-348
    • /
    • 2009
  • This paper introduces a novel denoising algorithm for the partial-discharge(PD) signals from power apparatuses. The developed algorithm includes three kinds of specific denoising sub-algorithms. The first sub-algorithm uses the fuzzy logic which classifies the noise types in the magnitude versus phase PD pattern. This sub-algorithm is especially effective in the rejection of the noise with high and constant magnitude. The second one is the method simply removing the pulses in the phase sections below the threshold count in the count versus phase pattern. This method is effective in removing the occasional high level noise pulses. The last denoising sub-algorithm uses the grouping characteristics of PD pulses in the 3D plot of the magnitude versus phase versus cycle. This special technique can remove the periodical noise pulses with varying magnitudes, which are very difficult to be removed by other denoising methods. Each of the sub-algorithm has different characteristic and shows different quality of the noise rejection. On that account, a parameter which numerically expresses the noise possessing degree of signal, is defined and evaluated. Using the parameter and above three sub-algorithms, an adaptive complex noise rejection algorithm for the on-line PD diagnosis system is developed. Proposed algorithm shows good performances in the various real PD signals measured from the power apparatuses in the Korean plants.

회전기 고정자 권선의 부분방전 측정용 RFCT 특성 (Characteristics of RFCT for Partial Discharge Measurement in the Stator Winding of Rotating Machines)

  • 강동식;윤대희;황돈하;김용주;장기찬;송상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1616-1618
    • /
    • 2001
  • In recent the on-line partial discharge (PD) measurement using sensors, such as EMC, SSC, RTD and RFCT, as an indicator of stator winding insulation condition has been developed. RFCT sensor was placed arounding a grounding lead of surge capacitor to detecting PD. Trend of PD magnitude/phase angle/pulse number over time are useful parameter to diagnosis aging state. We have developed Radio Frequency Current Transformer(RFCT) sensor which is suitable for PD diagnostic measurement in 6.6kV rotating machines. In this paper, we describe the characteristics of RFCT sensor, such as frequency and PD magnitude using 6.6 kV model stator winding in Lab.

  • PDF

교류전압에서 PD 패턴 및 유전체 장벽 방전에 미치는 공간전하의 영향 (The Effect of Space Charge on the PD Pattern and Dielectric Barrier Discharge under AC)

  • 권윤혁;황보승;이동영;한민구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권4호
    • /
    • pp.226-231
    • /
    • 2000
  • In this paper, we present new method to analyze the space charge effect on the electrical characteristics in polymer. It is new measurement system and analysis method that have not reported yet. By using this measurement system, we make observation to space charge accumulated on the surface of polymer at AC voltage, so it is examined to verify the correlation of space charge and partial discharge(PD). In the result of experiment, it can be known that PD pattern is related more closely to space charge accumulated on the surface of polymer than in the inner part, and applied voltage in the air is ruled by this dynamic partial discharge. Also, above critical voltage, the space charge accumulated on the surface of polymer have no effect to the magnitude of PD and the applied voltage in the air. It has been known that the electric power of the dissolution system is proportioned to the frequency and the magnitude of applied voltage, but we can know by this result of the experiment that the efficiency of the dissolution is not related to the rise of voltage above critical voltage.

  • PDF

A Study on the Condition Monitoring for GIS Using SVD in an Attractor of Chaos Theory

  • J.S. Kang;Kim, C.H.;R.K. Aggarwal
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권1호
    • /
    • pp.33-41
    • /
    • 2004
  • Knowledge of partial discharge (PD) is important to accurately diagnose and predict the condition of insulation. The PD phenomenon is highly complex and seems to be random in its occurrence. This paper indicates the possible use of chaos theory for the recognition and distinction concerning PD signals. Chaos refers to a state where the predictive abilities of a systems future are lost and the system is rendered aperiodic. The analysis of PD using deterministic chaos comprises of the study of the basic system dynamics of the PD phenomenon. This involves the construction of the PD attractor in state space. The simulation results show that the variance of an orthogonal axis in an attractor of chaos theory increases according to the magnitude and the number of PDs. However, it is difficult to clearly identify the characteristics of the PDs. Thus, we calculated the magnitude on an orthogonal axis in an attractor using singular value decomposition (SVD) and principal component analysis (PCA) to extract the numerical characteristics. In this paper, we proposed the condition monitoring method for gas insulated switchgear (GIS) using SVD for efficient calculation of the variance. Thousands of simulations have proven the accuracy and effectiveness of the proposed algorithm.

침전극의 곡율반경에 따른 트리개시전계 및 트리진전 특성 (Dependence of needle tip Curvature of the Inception Stress and Propagation of electrical tree)

  • 박영국;김완수;이홍규;이용희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.59-62
    • /
    • 1999
  • Inception and propagation of electrical tree and properties of Partial discharge(PD) pulses accompanying with tree as a function of needle tip radius in low density polyethylene were discussed. To study on these characteristics in different tip radius, we used specimens with needle-plane electrode system made of LDPE, observed inception and propagation of electrical tree by optical microscope with computer and investigated the characteristics of the phase resolved PD pulses accompanying with propagation of electrical tree. The PD quantities detected and analysed were PD magnitude, mean phase angle, average discharge, and the statistical characteristics of the PD pulses. As the tip radius ${\gamma}$ increases, tree inception stress E$\sub$i/ converges to constance value. This result suggests that tree inception stress E$\sub$i/ increases due to stress relaxation when the tip radius is small. Branch-type electrical tree was formed When E$\sub$i/ is 640-750[kV/mm]. bush-type electrical tree when E$\sub$i/ is 370∼400[kV/mm], branch-like electrical tree when E$\sub$i/ is 370-400[kV/mm].