• 제목/요약/키워드: PD(Partial discharge) sensor

검색결과 135건 처리시간 0.025초

기중부분방전원 식별을 위한 광대역 부분방전신호의 측정 및 주성분분석기법의 적용 (Application of Principle Component Analysis and Measurement of Ultra wideband PD signal for Identification of PD sources in Air)

  • 이강원;김명룡;박대원;심재복;창상훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.505-506
    • /
    • 2006
  • PD(partial discharge) occurred from variable PD sources in air may be the cause of breakdown in high voltage equipment which affect huge outage in power system. Identification and localization of PD sources is very important for engineer to cope with huge accident beforhand. PD phenomena can be detected by acoustic emission sensor or electromagnetic sensor like antenna. This paper has investigated the identification method using PCA(principal component analysis) for the PD signals from variable PD sources, for which the electric field distribution and PD inception voltages were simulated by using commercial FEM program. PD signals was detected by ultra wideband antenna. Their own features were extracted as the frequency coefficients transformed with FFT(fast fourier transform) and used to obtain independent pincipal components of each PD signals.

  • PDF

광섬유 센서를 이용한 절연유내의 부분방전 위치검출에 관한 연구 (A Study on Partial Discharge Location in Insulating Oil using Optical Fiber Sensors)

  • 권태호;이종길;이준호
    • 한국전기전자재료학회논문지
    • /
    • 제16권9호
    • /
    • pp.838-841
    • /
    • 2003
  • This paper shows results on the application of optical fiber sensors(OFS) for locations of ultrasonic signals in silicon insulating oil. The OFS system based on the principle of Sagnac interferometry has been designed and established for this work. The hollowed cylindrical mandrel wound by single mode optical fiber was used as a sensing component and ultrasonic signals which simulate the partial discharge In the oil have been generated by PZT actuator operated with function generator. The experimental results shows that the OFS has a excellent performance for the PD location with resolutions less than 1$^{\circ}C$ error range in the miniature insulating oil tank.

Numerical Study of Estimating the Arrival Time of UHF Signals for Partial Discharge Localization in a Power Transformer

  • Ha, Sang-Gyu;Cho, Jeahoon;Lee, Juneseok;Min, Byoung-Woon;Choi, Jaehoon;Jung, Kyung-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제18권2호
    • /
    • pp.94-100
    • /
    • 2018
  • Partial discharges (PDs) are electrical sparks that occur inside insulation between two conducting electrodes and can lead to the disastrous failure of insulation systems. To determine the location of a PD, a distributed array of UHF PD sensors is used to detect the electromagnetic (EM) signals emitted from the PD source, and the localization of the PD source can be estimated using the time difference of arrival (TDOA) between EM signals captured by the UHF PD sensor array. There are four popular methods to estimate the TDOA-the first peak method, the cross-correlation method, the energy criterion method, and the average time window threshold method. In this work, we numerically investigate the influence of noise on estimating the TDOA for the four different methods. Numerical results show that the energy criterion method is more robust against noise than other methods.

전력용변압기에서 UHF 부분방전 신호의 전파 특성 (Propagation Characteristics of Ultra High Frequency Partial Discharge Signals in Power Transformer)

  • 윤진열;한기선;주형준;구선근
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.798-803
    • /
    • 2010
  • This paper describes the characteristics of electromagnetic wave propagation in power transformer. A transformer which is similar to 154 kV single phase on-site transformer unit was provided for the purpose of the experiment. The 12 dielectric windows on the transformer enclosure to install UHF (ultra high frequency) sensors and the full scale mock ups of winding and the core were also equipped in the transformer. Every sensors to be installed to the transformer was tested and verified whether they show same characteristics or not before the experiment. A discharge gap which was used as a PD (partial discharge) source moved to several necessary locations in the transformer to simulate dielectric defects. Propagation times of electromagnetic wave signal from PD source to sensors decided by the routes of both reflection phenomenon and diffraction phenomenon were compared each other. The experimental results showed propagation route of the PD signal makes an effect on the frequency spectrum of front part of the signal and the magnitude of the signal and propagation time of the signal when the signal is captured on the sensor.

센서에 따른 부분방전 펄스 분석 및 노이즈 제거 기법에 대한 연구 (A Study on the PD Pulse Analysis and Noise Discrimination Method according to various sensors)

  • 김정태;이욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1469-1471
    • /
    • 2006
  • It is very important to discriminate noises such as air corona in measuring on-site partial discharges (PD). Therefore, in order to investigate the possibility of separating PD(partial discharge) and noises through the pulse analysis, pulse shapes measured by a resistive sensor and a HFCT were analyzed and PA(pulse analysis) were performed. For the purpose, the HFPD detection and PA system has been developed. Also void discharges and air corona were adopted as the artificial defect and noises, respectively.

  • PDF

폴리머 애자의 내전압 특성에 따른 부분방전 측정과 자외선 검출 (PD Measure and UV Detection in according to Withstand Voltage Characteristics of Polymer Insulator)

  • 송길목;김영석;김종서;정진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.76-77
    • /
    • 2008
  • The purposes of this paper ensure for the economical efficiency, accuracy, and good applications in domestic site set up the power installations. For the efficient conduct of these purposes, there are measured the partial discharge(PD) used by current probe and compared with detected signal of UV sensor. As the results, PD generated about 35% of breakdown voltage in polymer insulator. UV signal due to high voltage in polymer insulator is detected from about 1.7mV at 30kV to about 3mV at 70kV. Signal detected by ultra-sonic is increased at about 75% of breakdown voltage abruptly. It appears that error range is increased in boundary. UV sensor is needed must use from the practical and economical points of view.

  • PDF

광섬유 센서를 이용한 초음파 검출 (A Fiber-Optic Sensor for Ultrasonic Measurement)

  • 심승환;이광식;이동인;이상훈;김달우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1715-1717
    • /
    • 2001
  • The partial-discharge(PD) is accompanied by physical and chemical phenomena, such as heat, light, noise gas, chemical transformation, electric current, and electromagnetic radiation. The PD can be detected by measuring one of these changes. Although some techniques are employed in this purpose, several obstacles interfere with an on-line measurement. Now, a fiber-optic sensor for detecting ultrasonics is suggested for the on line measurement system with high accuracy. This paper describes the basic principles fiber-optic sensor for ultrasonic measurement.

  • PDF

GIS 스페이서의 에폭시 주입구 장착형 UHF PD 센서의 성능 비교 (A comparison of the characteristics of External type UHF partial discharge sensor for metal covered barriers in GIS)

  • 황철민;김영노;이영상;곽주식;박기준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2265-2267
    • /
    • 2005
  • We present detailed studies of externally applicable UHF PD sensors for a metal covered epoxy barrier with a small opening of epoxy injection-hole. The sensors were attached at the surface of injection hole of a metal covered epoxy barrier. 3-Dimensional electro magnetic simulations were performed to analyze electric-field distribution of the GIS and epoxy barrier with injection hole. Sensor structures were designed and analyzed using the 3-D EM simulator then fabricated for experimental verification. Sensor performance was measured in terms of spectral response and detected peak power. Real scale GIS and epoxy barriers were used to test and measure various aspect of performance of the sensors.

  • PDF

HFPD 및 신경회로망을 이용한 고압 유도전동기 모델코일 열화진단 (Aging Diagnosis of Model Coil of HV Induction Motor Using HFPD and Neural Networks)

  • 김덕근;임장섭;여인선
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권8호
    • /
    • pp.361-367
    • /
    • 2002
  • Many failures in high voltage equipment are preceded by partial discharge activity. In this paper deals with the application of the high frequency partial discharge measurement technique in motorette. HFPD measurement is very effective method to detect the PD occurred in motorette which is the called name of test specimen for accelerating test of stator winding[1] In this study, CT type HFPD sensor is used to detect the partial discharges and a measured HFPD pattern is analyzed by fractal mathematics. The neural network algorithm is used to pattern recognition and ageing diagnosis. As a result of this study, the fractal dimensions are increased along to applied voltage and HFPD pattern recognition using neural network shown excellent recognition rate. Also, the ageing diagnosis of motorette has been Possible.

UHF대역 PD신호검출에 의한 GIS 결함위치표정의 현장적용 연구 (Om-site Application of External UHF PD Sensor for the Identification of Partial Discharge Location)

  • 이창용;홍철용;윤치영;윤자홍;남극채;이학동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1766-1768
    • /
    • 2004
  • This paper describes the prediction of location of PD signals in GIS using the difference in the measured time between first and second wave arrival by the external-type PD sensors. It is well accepted that the electromagnetic wave in GIS propagates at the velocity of $3{\times}10^8$m/s. Consequently, we could identify the location of PD with high accuracy. The experience at the fields and the problems for the judgment are also discussed in detail.

  • PDF