• Title/Summary/Keyword: PCU

Search Result 48, Processing Time 0.046 seconds

Integrated PCU Development for NEV (NEV용 통합 PCU 구현)

  • Jang, Byungwoon;Jung, Joongki;Hur, Min;Jang, Jaehoon;Lee, Jaeho;Yang, Chunsuk
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.298-299
    • /
    • 2011
  • 본 논문은 전기자동차용 통합 PCU의 개발에 관한 것으로서 상용전원을 입력으로 하여 전기자동차의 배터리를 충전하는 Charger 부분과, 충전된 배터리를 입력전원으로 하여 전기차의 구동용 모터를 동작시키는 Inverter 부분이 통합 구성되어 있다. 이를 위해 서로 분리된 Charger부와 Inverter부를 하나의 회로로 통합함으로써 부피와 무게 측면에서 차량 내부의 한정된 공간에 적합할 뿐만 아니라 가격절감 및 신뢰성 측면에 있어서 이점을 가지고 있다.

  • PDF

An Information Transmission Method of the DC Switchgear for Light Railway Vehicle (경량전철용 직류배전반의 정보 전송방식)

  • Lee, H.D.;Kim, S.N.;Ryu, S.P.;Lee, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.143-145
    • /
    • 2005
  • This paper describes the transmission method of an information using communication networks between RTU(Remote Terminal Unit) and PCU(Protection and Control System) of the DC switchgear for Light Railway Vehicle. Also the test result carried out in the laboratory was represented. In this test, transmission signal waveform, polling time, response time and request/response frame between RTU and PCU were measured. The field test including the measurements of analog signal and status of the digital logic operation of PCU was conducted in Gyeongsan Test Track.

  • PDF

Development of Proportional Valve Actuator Controller for Industrial Site (산업용 밸브 액추에이터 비례제어 컨트롤러 개발)

  • Park, Han Young;Kim, Jin Young;Ahn, Sung Soo;Kang, Joonhee
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.269-274
    • /
    • 2013
  • To proportionally control the electronic valve position of the actuator, we designed and fabricated PCU, CPT, and rotary absolute optical encoder for the detection of absolute angular position in the actuator. We also designed and constructed the test system by using DAQ hardware and Labview. We designed PCU to convert 1-5 V, 0-5 V, 0-10 V, 2-10 V voltage signals and 4-20 mA current signals to the voltage signals in the common 0.5-2.5 V range. We designed CPT to output 4-20 mA current signals corresponding to the valve positions based on the PWM signal input from the MCU. We also designed 20 bit optical encoder by using infrared LED and infrared transistor and made the serial communication with the main board possible. When we tested PCU and CPT with DAQ hardware and Labview software, they operated correctly with the small errors within ${\pm}0.003$ V and ${\pm}0.01$ mA, respectively, showing that our actuator has the excellent performance to employ as the industrial proportional-valve-actuator. The resolution of the encoder was $11.25^{\circ}$ and the maximum revolution to detect was 32,768.

A development of simulator for satellite power system (인공위성용 전력시스템 시뮬레이텨 개발)

  • 김영태;김희준
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.3
    • /
    • pp.193-201
    • /
    • 1996
  • The space power system for communication satellite which employs the direct energy transfer (DET) method consists of solar array, battry, shunt regulator, charger/discharger and power control unit (PCU). In this paper, the development of the DET power system charger/discharger unit and a microprocessor based PCU is developed for simplicity and flexiblity in the modificatin of control algorithm. A 28V bus voltage, 400W power rting power simulator is built and tested to verify the operation of the simulator at each mode and the stability of mode transition is analyzed.

  • PDF

An Information Transmission Method of DC Switch Gear for Light Railway Vehicle using Communication Network (통신망을 이용한 경량전철용 직류배전반의 정보 전송방식)

  • Lee H.D.;Jeon Y.J.;Kim S.N.;Baek B.S.;Ryu S.P.;Seo K.D.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.953-955
    • /
    • 2004
  • This paper describes the information transmission method using communication networks between Remote Terminal Unit(RTU) and Protection and Control system(PCU) of the direct current switchgear for Light Railway Vehicle, and also represents the test result, which carried out in the laboratory. In this test, transmission signal waveform, polling time, response time and request/response frame were measured between RTU and PCU. The field test including the measurements of analog signal and status of the digital logic operation of PCU will be conducted in near future.

  • PDF

Identification of a p-Cresol Degradation Pathway by a GFP-Based Transposon in Pseudomonas and Its Dominant Expression in Colonies

  • Cho, Ah-Ra;Lim, Eun-Jin;Veeranagouda, Yaligara;Lee, Kyoung
    • Journal of Microbiology and Biotechnology
    • /
    • v.21 no.11
    • /
    • pp.1179-1183
    • /
    • 2011
  • In this study, the chromosome-encoded pcuRCAXB genes that are required for p-cresol degradation have been identified by using a newly constructed green fluorescent protein (GFP)-based promoter probe transposon in the long-chain alkylphenol degrader Pseudomonas alkylphenolia. The deduced amino acid sequences of the genes showed the highest identities at the levels of 65-93% compared with those in the databases. The transposon was identified to be inserted in the pcuA gene, with the promoterless gfp gene being under the control of the pcu catabolic gene promoter. The expression of GFP was positively induced by p-cresol and was about 10 times higher by cells grown on agar than those in liquid culture. In addition, p-hydroxybenzoic acid was detected during p-cresol degradation. These results indicate that P. alkylphenolia additionally possesses a protocatechuate ortho-cleavage route for p-cresol degradation that is dominantly expressed in colonies.

A parallel control algorithm of 3MW EBOP for Molten Carbonate Fuel Cell(MCFC) power plant (3MW급 연료전지용 EBOP의 병렬제어 알고리즘)

  • Hwang, Tai-Sik;Kim, Hyeong-Su;Kim, Yun-Hyun;Kim, Kwang-Seob
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.120-122
    • /
    • 2009
  • 발전용 연료전지 시스템은 수소와 산소를 공급받아 직류전기와 열로 변화시키는 연료전지 스택, 연료전지 스택에 연료와 공기를 공급해주는 MBOP(Mechanical Balance Of Plant), 연료전지의 출력을 계통에 연계시키는 EBOP(Electrical Balance Of Plant)로 구성된다. EBOP 시스템은 병렬 연결된 1.5MW PCU(Power Conversion Unit)로 구성되며, 각 PCU는 750kW 인버터가 병렬로 구성된다. 본 논문에서는 4병렬로 구성된 3MW급 연료전지용 EBOP의 병렬제어 알고리즘을 소개한다. 제안한 병렬제어 알고리즘은 과도응답이 빠르고 순환전류가 없는 제어특성을 가진다. 그리고 시뮬레이션과 실험으로 제안한 알고리즘의 성능을 확인한다.

  • PDF

Analyses and Evaluation of Gird Connected PCU for PV System (태양광발전용 계통연계형 PCU의 성능특성 분석평가)

  • So J. H.;Jung Y. S.;Yu G. J.;Choi J. Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.65-68
    • /
    • 2003
  • 3kW grid-connected photovoltaic(PV) systems and data acquisition system are constructed for performance analysis of PV system at field demonstration test center of Gwang-Ju in Korea. As climatic and irradiation conditions are varied, operation characteristics of the PV system are collected and analyzed in data acquisition system. From these results, the performances of PV systems have simulated and evaluated using simulation tool In comparison with actual value of data acquisition system of field demonstration test center. Furthermore, performance of each PV system e.g. electric power and loss factor is reviewed.

  • PDF

Event Logging Method for Control Rod Control System (원자로 제어봉구동장치 제어시스템용 이벤트 기록 방법)

  • Cheon, Jong-Min;Kim, Choon-Kyung;Jo, Chang-Hui;Jeong, Soon-Hyun;Nam, Jeong-Han
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.552-554
    • /
    • 2003
  • This paper is about the method by which Power Control Unit(PCU) of Control Rod Control System(CRCS) logs events in the system and the real-time monitoring display. This method enables the functions like the event logging of Control Rod Drive Mechanism(CRDM)/power Cabinet, the off-line show of the event data logged and the on-line show by communication between the PCU and the monitoring display. Operators in a nuclear power plant must be able to grasp any possible abnormal states correctly. Because our newly designed system has a good ability to log and display the kinds, tine, and the prior and posterior states of urgent or non-urgent events, the operators can judge, maintain and repair the abnormal event more easily.

  • PDF

A Study on Roundabout Signal Metering Operation by Considering Entry Lane's Traffic Volume (진입교통량을 고려한 회전교차로 Signal Metering 운영에 관한 연구)

  • Ahn, Woo-Young
    • International Journal of Highway Engineering
    • /
    • v.14 no.2
    • /
    • pp.175-181
    • /
    • 2012
  • Under unsaturated capacity conditions with balanced approach flows, roundabout gives less delay and queue length than existing signalized intersections; however, over capacity conditions with unbalanced approach flows(flow above 450 pcu/h/lane), roundabouts efficiency drops due to the short gap between entering vehicles and circulating vehicles. This study provides a roundabout Signal Metering transfer standard and operation method. In this study, a four-way-approach with one-lane roundabout is selected to compare the Signal Metering performance for the case of unbalanced flow conditions. The performance is evaluated by using SIDRA software in terms of average delay and queue length. The result shows that the Signal Metering provides substantial improvements for the case of total approach flow is 1,800~2,000 pcu/h in which the main approach flow ratio is 60~70% gives 30~40% less delay and 30~60% less queue length than normal roundabout operation. Also, it is approved that operational performance saving can be achieved when the Metered Approach is selected adjoining to the main approach in pair.