• Title/Summary/Keyword: PCT curve

Search Result 21, Processing Time 0.166 seconds

Microstructure and Corrosion Behavior of Various Grain Size Cp-Ti (입자크기를 달리한 Cp-Ti의 미세구조 관찰 및 SBF하에서의 부식거동)

  • Lee Seung-Woo;Kim Yun-Jong;Ruy Jae-Gyeoung;Park Joong-Keun;Kim Won-Soo;Kim Taik-Nam
    • Korean Journal of Materials Research
    • /
    • v.15 no.9
    • /
    • pp.585-588
    • /
    • 2005
  • Titanium and Titanium alloys are widely used as an orthopedic and dental implant material because of their excellent biocompatibility and mechanical strength. In this study, ECAP Cp-Ti and Cp-Ti were heat treated for different annealing time of 30 min, 90 min and 3 hours. The grain size for each condition was studied. The micro-Vicker hardness test was carried out f3r each different heat treated samples. The micro-Vicker hardness test for ECAP Cp-Ti, Cp-Ti and Cp-Ti (3hr) revealed hardness values of 239.5, 182 and 144 Hv, respectively. The grain size was increased from approximately $70{\mu}m\;to\;300{\mu}m$ with the increase in heat treatment time from 30 min to 3 hours. The heat treated samples were tested for their biocompatibility in simulated body fluid (SBF) and corrosion rates was determined using Polarization Curve test (PCT). The PCT results showed Cp-Ti with comparatively high corrosion potential of -0.18 V and corresponding corrosion current of $2\times10^{-6}$ A, while the corrosion rate in ECAP Cp-Ti and Cp-Ti (30 min annealed) showed very similar results of corrosion potential about -0.47 V with corresponding corrosion current of $7\times10^{-8}$ A.

Corrosion behavior in SBF and Microstructure of ECAP- Ti and Ti Alloys (ECAP-Ti와 Alloy의 미세구조와 생체유사용액에서의 부식거동)

  • Kim Ill-Yong;Avinash, B.;Kim Yoon-Jong;Lee Seung-Woo;Shin Jong-Woo;Park Joong-Keun;Lee Sung-Ho;Kim Taik-Nam
    • Korean Journal of Materials Research
    • /
    • v.14 no.6
    • /
    • pp.432-435
    • /
    • 2004
  • Ti and Ti alloys are important materials for medical and dental applications. The effect of equal channel angular process(ECAP) and addition of Fe in Ti were studied with optical microstructure and corrosion behavior. Fine grains in Ti was obtained after ECAP. Corrosion behavior of commercial pure(CP)-Ti and Ti alloys was studied by open circuit test and polarization curve test(PCT) at $36.5^{\circ}C$ with SBF in biological environment. The corrosion behavior of ECAP-Ti was similar to that of CP-Ti in PCT, but Ti-Fe alloys were observed to become more corrosive with increasing Fe content.

Diagnostic Role of C-reactive Protein, Procalcitonin and Lipopolysaccharide-Binding Protein in Discriminating Bacterial-Community Acquired Pneumonia from 2009 H1N1 Influenza A Infection (박테리아성 지역사회획득 폐렴과 2009 H1N1 바이러스성 감염의 감별에 있어 C-Reactive Protein, Procalcitonin, Lipopolysaccharide-Binding Protein의 역할)

  • Han, Seon-Sook;Kim, Se-Hyun;Kim, Woo-Jin;Lee, Seung-Joon;Ryu, Sook-Won;Cheon, Myeong-Ju
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.6
    • /
    • pp.490-497
    • /
    • 2011
  • Background: It is difficult but important to differentiate between bacterial and viral infections, especially for respiratory infections. Hence, there is an ongoing need for sensitive and specific markers of bacterial infections. We investigated novel biomarkers for discriminating community acquired bacterial pneumonia from 2009 H1N1 influenza A infections. Methods: This was a prospective, observational study of patients with community acquired bacterial pneumonia, 2009 H1N1 Influenza A infection, and healthy controls. Serum samples were obtained on the initial visit to the hospital and stored at $-80^{\circ}C$. We evaluated CRP (C-reactive protein), PCT (procalcitonin), LBP (lipopolysaccharide-binding protein) and copeptin. These analytes were all evaluated retrospectively except CRP. Receiver operating characteristic curve (ROC) analyses were performed on the resulting data. Results: Enrolled patients included 27 with community acquired bacterial pneumonia, 20 with 2009 H1N1 Influenza A infection, and 26 who were healthy controls. In an ROC analysis for discriminating community acquired bacterial pneumonia from 2009 H1N1 influenza A infection, areas under the curve (AUCs) were 0.799 for CRP (95% Confidence interval [CI], 0.664~0.934), 0.753 for PCT (95% CI, 0.613~0.892) and 0.684 for LBP (95% CI, 0.531~0.837). Copeptin was not different among the three groups. Conclusion: These findings suggest that serum CRP, PCT and LBP can assist physicians in discriminating community acquired bacterial pneumonia from 2009 H1N1 influenza A infection.

Usefulness of Serum Cortisol in Assessment for the Severity of Community-Acquired Pneumonia (지역사회 획득 폐렴환자의 중증도 평가에서 혈청 코티졸의 유용성)

  • Yoon, Kyung-Hwa;Kim, Yeon-Jae;Kim, Mi-Young;Kim, Eun-Young;Bae, Myoung-Nam;Bae, Sang-Mook;Kim, Min-Su;Park, Hun-Pyo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.6
    • /
    • pp.450-455
    • /
    • 2010
  • Background: High cortisol levels are frequently observed in patients with severe infections are of prognostic value in sepsis. The aim of this study was to evaluate the clinical usefulness of serum cortisol in assessment for the severity of community-acquired pneumonia (CAP). Methods: This study analyzed the results of 52 CAP subjects admitted in Changwon Fatima Hospital between July 2008 to May 2010. Total serum cortisol, infection markers such as C-reactive protein (CRP), procalcitonin (PCT) and CURB (Confusion, Uremia, Respiratory rate, Blood pressure)-65 were examined retrospectively. Results: In clinically unstable subjects on admission day 4, baseline serum cortisol, CURB-65, and CRP were elevated significantly compared to those of stable subjects. Area under curve (AUC) of cortisol, CRP, and CURB-65 from ROC curves were 0.847, 0.783, and 0.724 respectively. In the subjects with serum cortisol ${\geq}22.82{\mu}g/dL$, CRP, PCT, CURB-65 score, and mortality were significantly elevated. Conclusion: These findings suggest that measurement of serum cortisol in early stage may provide helpful information in the assessment of CAP severity.

Corrosion Analysis and Apatite Forming Ability of Ti and Ti-Alloys in SBF Solution (Ti과 Ti합금의 SBF에서 Apatite 형성 관찰 및 부식거동 테스트)

  • Lee Seung-Woo;Kim Yun-Jong;Choi Je-Woo;Park Joong-Keun;Kim Won-Soo;Kim Taik-Nam
    • Korean Journal of Materials Research
    • /
    • v.15 no.10
    • /
    • pp.671-677
    • /
    • 2005
  • Ti and Ti alloys are known to have excellent corrosion properties, which is an important aspect for biocompability of these implants in human body. In our study, four types of samples (Cp-Ti, Ti-6Al-4V, $0.5wt.\%$ Fe-Ti and ECAP Ti) were tested for their apatite forming ability and corrosion properties. The micropolished samples were treated with 5M NaOH solution at $60^{\circ}C$ for 24 hours. Each samples was gently washed with distilled water and heat-treated at 600"C for 1 hour. The heat-treated samples were soaked in Simulated Body Fluid (SBF) solution at $36.5^{\circ}C$ in an incubator for different period of time. The test revealed that $0.5 wt.\%$ Fe-Ti showing faster apatite growth on the surface (7th day) compared to other samples. Polarization curve test (PCT) was also carried out to determine the corrosion resistance of each samples in SBF solution. ECAP-Ti showed highest corrosion resistance compared to any other samples. $0.5wt.\%Fe-Ti$ showed higher corrosion potential and corrosion current compared to other samples.

High Temperature Deformation Behavior of Al 5083 Alloy Using Deformation Processing Maps (변형가공도를 이용한 AI 5083 합금의 고온변형거동)

  • Ko, Byung-Chul;Kim, Jong-Hyun;Yoo, Yeon-Chul
    • Transactions of Materials Processing
    • /
    • v.7 no.5
    • /
    • pp.450-458
    • /
    • 1998
  • The high temperature deformation behavior of Al 5083 alloy has been studied in the temperature range of 350 to 520 ${\circ}C$ and strain rate range of 0.2 to 3.0/sec by torsion test. The strain rate sensitivity(m) of the material was evaluated and used for estabilishing power dissipation maps following the dynamic material model. These maps show the variation of efficiency of power dissipation(${\eta}$=2m/(2m+1)) with temperature and strain rate. Hot restoration of dynamic recrystallization (DRX) was analyzed from the flow curve, deformed microstructure, and processing maps during hot deformation. Also, the effect of deformation strain on the efficiency of power dissipation of the alloy was analysed using the processing maps. Moreover relationship between the hot-ductility and efficiency of power dissipation of the alloy depending on thmperature and strain rate was studied using the Zener-Hollomon parameter(Z=${\varepsilon}$exp(Q/RT) It is found that the maximum efficiency of power dissipation for DRX in Al 5083 alloy is about 74.6 pct at the strain of 0.2. The strain rate and temperature at which the efficiency peak occurred in the DRX domain is found to be ∼0.1/sec and ∼450${\circ}C$ respectively.

  • PDF

Pleural Fluid Pentraxin-3 for the Differential Diagnosis of Pleural Effusions

  • Yeo, Chang Dong;Kim, Jin Woo;Cho, Mi Ran;Kang, Ji Young;Kim, Seung Joon;Kim, Young Kyoon;Lee, Sang Haak;Park, Chan Kwon;Kim, Sang Ho;Park, Mi Sun;Yim, Hyeon Woo;Park, Jong Y.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.75 no.6
    • /
    • pp.244-249
    • /
    • 2013
  • Background: Conventional biomarkers cannot always establish the cause of pleural effusions; thus, alternative tests permitting rapid and accurate diagnosis are required. The primary aim of this study is to assess the ability of pentraxin-3 (PTX3) in order to diagnose the cause of pleural effusion and compare its efficacy to that of other previously identified biomarkers. Methods: We studied 118 patients with pleural effusion, classified as transudates and exudates including malignant, tuberculous, and parapneumonic effusions (MPE, TPE, and PPE). The levels of PTX3, C-reactive protein (CRP), procalcitonin (PCT) and lactate in the pleural fluid were assessed. Results: The levels of pleural fluid PTX3 were significantly higher in patients with PPE than in those with MPE or TPE. PTX3 yielded the most favorable discriminating ability to predict PPE from MPE or TPE by providing the following: area under the curve, 0.74 (95% confidence interval, 0.63-0.84), sensitivity, 62.07%; and specificity, 81.08% with a cut-off point of 25.00 ng/mL. Conclusion: Our data suggests that PTX3 may allow improved differentiation of PPE from MPE or TPE compared to the previously identified biomarkers CRP and PCT.

Hydriding Kinetics on Mg2NiHx-5wt% CaO Composites (Mg2NiHx-5wt% CaO 복합재료의 수소화 속도)

  • SHIN, HYO-WON;HWANG, JUNE-HYEON;KIM, EUN-A;HONG, TAE-WHAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.3
    • /
    • pp.156-162
    • /
    • 2021
  • Mg hydride has a relatively high hydrogen storage amount of 7.6wt%, and inexpensive due to abundant resources, but has high reaction temperature and long reaction time because of treble oxidation reactivity and upper activation energy. Their range of applications could be further extended if their hydrogenation kinetics and degradation behavior could be improved. Therefore, the effect of CaO has improved the hydrogenation kinetics and slowed down the degradation. This study focused on investigating whether to improve the hydrogenation kinetics by synthesizing Mg2NiHx-5wt% CaO composites. The Mg2NiHx-5wt% CaO composites have been synthesized by hydrogen induced mechanical alloying. The synthesized composites were characterized by performing X-ray diffraction, Scanning Electron Microscopy, Brunauer-Emmett-Teller, Thermogravimetric, and Sivert's type automatic pressure-composition-temperature analysis. Hydriding kinetics were performed using an automatic PCT measurement system and evaluated over the temperature range of 423 K, 523 K, and 623 K. As a result of calculating the hydrogen adsorption amount through the hydrogenation kinetics curve, it was calculated as about 0.42wt%, 0.91wt%, and 1.15wt%, the highest at 623 K and the lowest at 423 K.

Preparation of TiCoxFe1-x(x=0.50~1.00) System Metal Membrane for Hydrogen Separation (수소분리용 TiCoxFe1-x(x=0.50~1.00)계 금속막 제조)

  • Jang, Kyu-young;Kang, Tae Beom
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.191-201
    • /
    • 2015
  • We have studied on the preparation of $TiCo_xFe_{1-x}$(x=0.50~1.00) system alloy, the characteristics of $TiCo_xFe_{1-x}$(x=0.50~1.00) system alloy by X-ray diffractometer (XRD), pressure composition temperature (PCT) curve, scanning electron microscopy (SEM) and the $H_2-N_2$ gas mixture separation of $TiCo_xFe_{1-x}$(x=0.50~1.00)- stainless steel (SS) composite membranes. The formation of $TiCo_xFe_{1-x}$(x=0.50~1.00) system alloys with cubic crystal same as TiCo was confirmed by X-ray diffractometer. $TiCo_xFe_{1-x}$(x=0.50~1.00) system alloys showed the hysteresis at $120^{\circ}C$. As the Fe content of $TiCo_xFe_{1-x}$(x=0.50~1.00) system alloys increased, the hysteresis was increased both range x=0.90~1.00 and x=0.55~0.60, and the range x=0.55~0.90 gave decreased hysteresis. $TiCo_{0.55}Fe_{0.45}$ alloy was the one showed the lowest hysteresis among them. The lowest value of hydrogen permeation pressure of $TiCo_xFe_{1-x}$(x=0.50~1.00)-SS composite membrane was $TiCo_{0.55}Fe_{0.45}$-SS composite membrane with the value of 2.5 atm at $120^{\circ}C$; otherwise, $TiCo_{0.90}Fe_{0.10}$-SS composite had the highest pressure value among the membranes with the value of 10 atm. $TiCo_{0.55}Fe_{0.45}$-SS composite membrane was the best to separate the $H_2-N_2$ gas mixture excellently among the $TiCo_xFe_{1-x}$(x=0.50~1.00)-SS composite membranes since $TiCo_{0.55}Fe_{0.45}$ had the least hysteresis, and hydrogen permeation pressure was the lowest with value of 2.5 atm.

Electrochemical properties of $AB_5$-type Hydrogen alloys upon addition of Zr, Ti and V ($AB_5$계 수소저장합금의 Zr, Ti 및 V 첨가에 따른 전기화학적특성)

  • Kim, D.H.;Cho, S.W.;Jung, S.R.;Park, C.N.;Choi, J.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.1
    • /
    • pp.31-38
    • /
    • 2006
  • There are two types of metal hydride electrodes as a negative electrode in a Ni-MH battery, $AB_2$ Zr-based Laves phases and $AB_5$ LM(La-rich mischmetal)-based alloys. The $AB_5$ alloy electrodes have characteristic properties such as a large discharge capacity per volume, easiness in activation, long cycle life and a low cost of alloy. However they have a relatively small discharge capacity per weight. The $AB_2$alloy electrodes have a much higher discharge capacity per weight than $AB_5$ alloy electrodes, however they have some disadvantages of poor activation behavior and cycle life. Therefore, in order to improve the discharge capacity of the $AB_5$ alloy electrode the Zr, Ti and V which are the alloying elements of the $AB_2$ alloys were added to the $LaNi_{3.6}Ai_{0.4}Co_{0.7}Mn_{0.3}$ alloy which was chosen as a $AB_5$ alloy with a high capacity. The addition of Zr, Ti and V to $LaNi_{3.6}Ai_{0.4}Co_{0.7}Mn_{0.3}$ alloy improved the activation to be completed in two cycles. The discharge capacities of Zr 0.02, Ti 0.02 and V 0.1 alloys in $LaNi_{3.6}Ai_{0.4}Co_{0.7}Mn_{0.3}M_y$ (M = Zr, Ti, V) were respectively 346, 348 and 366 mAh/g alloy. The alloy electrodes, Zr 0.02, Ti 0.05 and V 0.1 in $LaNi_{3.6}Ai_{0.4}Co_{0.7}Mn_{0.3}M_y$ (M = Zr, Ti, V), have shown good cycle property after 200 cycles. The rate capability of the $LaNi_{3.6}Ai_{0.4}Co_{0.7}Mn_{0.3}M_y$ (M = Zr, Ti, V) alloy electrodes were very good until 0.6 C rate and the alloys, Zr 0.02, Ti 0.05 and V 0.1, have shown the best result as 92 % at 2.4 C rate. The charge retention property of the $LaNi_{3.6}Ai_{0.4}Co_{0.7}Mn_{0.3}M_y$ (M = Zr, Ti, V) alloys was not good and the alloys with M content from 0.02 to 0.05 showed better charge retention properties.