• Title/Summary/Keyword: PCM method

Search Result 195, Processing Time 0.041 seconds

Sound Quality Evaluation of Optical Disc Drive Seek Noise (광 디스크 드라이브 Seek 소음의 음질 평가)

  • 이상윤;최명렬;성평용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.401-405
    • /
    • 2003
  • Sound quality is becoming a major concern in optical disc drives (ODD). In order to improve the sound quality of slim type ODDs, we changed lead screw pitch and firmware algorithm in the seek mode. To evaluate the sound quality, the PCM (Paired Comparison Method) was adopted and the result was compared with the time-averaged loudness spectrum. Sound signals were also recorded and modified by increasing or decreasing selected frequency bands to verify their sensitivities to the sound quality. As a result of jury test, preferred frequency bands are associated with the time-averaged loudness spectrum.

  • PDF

Analysis of Iron Loss Caused by Non sinusoidal Magnetic Behavior in Motor Core (모터 코아 내부에서 비정현적 자계의 거동에 따른 철손 해석)

  • Ha, Kyung-Ho;Cha, Sang-Yoon;Kim, Jae-Kwan;Lim, Yang-Su;Hur, Yoon;Hong, Jeong-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1071-1073
    • /
    • 2005
  • This paper investigates magnetic field behavior and its iron losses in the stator core using electrical steels. The analysis model is a brushless motor with the permanent magnet. The elliptical rotating and alternating flux distributions with non-sinusoidal waveforms are obtained by Finite Element Method and then their harmonic components are extracted. Based on these results, the local iron losses in the stator core caused by the harmonic flux are calculated. Furthmore, this paper explains the relation between the complex flux waveform and iron loss produced in each part of the stator core.

  • PDF

A Study on the Efficient Measurement of Airborne Asbestos Concentrations at Demolition Sites of Asbestos Containing Buildings, etc. in Seoul (서울시내 석면함유 건축물 철거 현장 등에서의 효과적인 공기 중 석면농도 측정을 위한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jeongyeun;Kim, Jihui;Chung, Sooknye;Kim, Jina;Oh, Seokryul;Kim, Iksoo;Shin, Jinho;Eo, Soomi;Jung, Kweon;Lee, Jinsook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.113-121
    • /
    • 2014
  • Objectives: This study is intended to seek credible and efficient measurements on airborne asbestos concentrations that allow immediate action by establishing complementary data through comparative analysis with existing PCM and KF-100 method real-time monitoring equipment in working areas in Seoul where asbestos-containing buildings are being demolished, including living environment surroundings. Materials: We measured airborne asbestos concentrations using PCM and KF-100 at research institutes, monitoring networks, subway stations and demolition sites of asbestos-containing buildings. Through this measurement data and KF-100 performance testing, we drew a conversion factor and applied it via KF-100. Finally we verified the relationship between PCM and KF-100 with statistical methods. Results: The airborne asbestos concentrations by PCM for the objects of study were less than the detection limit(7 fiber/$mm^2$) in three (20%) out of 15 samples. The highest concentration was 0.009 f/cc. The airborne asbestos concentrations by PCM in laboratories, monitoring networks, subway stations and demolition sites of asbestos-containing buildings were respectively $0.002{\pm}0.000$ f/cc, $0.004{\pm}0.001$ f/cc, $0.009{\pm}0.001$ f/cc, and $0.002{\pm}0.000$ f/cc. As a result of KF-100 performance testson rooftops, the conversion factor was 0.1958. Applying the conversion factor to KF-100 for laboratories, the airborne asbestos concentrations ratio of the two ways was nearly 1:1.5($R^2$=0.8852). Also,the airborne asbestos concentration ratio of the two ways was nearly 1:1($R^2$=0.9071) for monitoring networks, subway stations, and demolition sites of asbestos-containing buildings. As a result of independent sample t-tests, there was no distinction between airborne asbestos concentrations monitored in the two ways. Conclusions: In working areas where asbestos-containing buildings are being demolished, including living environment surroundings, quickly and accurately monitoring airborne asbestos scattered in the air around the working area is highly important. For this, we believea mutual interface of existing PCM and a real-time monitoring equipment method is possible.

A Study on Chemical Modification of Papermaking Fibers (I) - Improved Physical Characteristics from Partial Carboxymethylated Pulps - (제지용(製紙用) 섬유(纖維)의 화학적(化學的) 개질(改質)에 관한 연구(硏究) (I) - Partial Carboxymethylation 처리에 의한 물성(物性) 향상(向上) -)

  • Choi, Jeong-Heon;Jo, Byoung-Muk;Oh, Jung-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.37-46
    • /
    • 1995
  • The substitution of carboxymethylated hydroxyl group in pulp revealed more hydrophilic than hydroxyl group. And then fibers were more flexible, swell more which leads to better conformation between fibers in turn this raise paper strength. In this paper, we tried to chemical modifyings of recycled fiber, OCCs(old corrugated containers). Many researchers have examined chemical modification of papermaking fiber by partial carboxymethylation(PCM) using a organic solvent processes. We made modified PCM processes adapted waters m replace of the organic solvent. Our testings for the optimum conditions on the new method, conditions as reaction time, temperature, liquor ratios were designed likely plant system. Freenesses(SR$^{\circ}$) were increased following on carboxyl content of the samples. Handsheets of untreated samples and partial carboxymethylated OCCs were made by optimum conditions on different concentrations of the reagent. As results, maximum 25% strength increasing effects were obtained by the new method.

  • PDF

Enhanced Mutual Authentication Scheme based on Chaotic Map for PCM in NFC Service Environment

  • Park, Sung-Wook;Lee, Im-Yeong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.2
    • /
    • pp.1180-1200
    • /
    • 2017
  • Currently, automated payment services provide intuitive user interfaces by adapting various wireless communication devices with mobile services. For example, companies like Samsung, Google, and Apple have selected the NFC payment method to service payments of existing credit cards. An electronic payment standard has been released for NFC activation within Korea and will strengthen the safety of payment service communications. However, there are various security risks regarding the NFC-based electronic payment method. In particular, the NFC payment service using the recently released lightweight devices cannot provide the cryptographic strength that is supported by many financial transaction services. This is largely due to its computational complexity and large storage resource requirements. The chaotic map introduced in this study can generate a highly complicated code as it is sensitive to the initial conditions. As the lightweight study using the chaotic map has been actively carried out in recent years, associated authentication techniques of the lightweight environment have been released. If applied with a chaotic map, a high level of cryptographic strength can be achieved that can provide more functions than simple XOR operations or HASH functions. Further, this technique can be used by financial transaction services. This study proposes a mutual authentication technique for NFC-PCM to support an NFC payment service environment based on the chaotic map.

Adaptive Control of Peak Current Mode Controlled Boost Converter Supplied by Fuel Cell

  • Bjazic, Toni;Ban, Zeljko;Peric, Nedjeljko
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.122-138
    • /
    • 2013
  • Adaptive control of a peak current mode controlled (PCM) boost converter supplied by a PEM fuel cell is described in this paper. The adaptive controller with reference model and signal adaptation is developed in order to compensate the deviation of the response during the change of the operating point. The procedure for determining the adaptive algorithm's weighting coefficients, based on a combination of the pole-zero placement method and an optimization method is proposed. After applying the proposed procedure, the optimal adaptive algorithm's weighting coefficients can be determined in just a few iterations, without the use of a computer, thus greatly facilitating the application of the algorithm in real systems. Simulation and experimental results show that the dynamic behavior of a highly nonlinear control system with a fuel cell and a PCM boost converter, can fairly accurately be described by the dynamic behavior of the reference model, i.e., a linear system with constant parameters.

Reliability Analysis of the 300 W GaInP/GaAs/Ge Solar Cell Array Using PCM

  • Shin, Goo-Hwan;Kwon, Se-Jin;Lee, Hu-Seung
    • Journal of Astronomy and Space Sciences
    • /
    • v.36 no.2
    • /
    • pp.69-74
    • /
    • 2019
  • Spacecraft requires sufficient power in orbit to perform its mission. So as to comply with system requirements, the sufficient power should be made by a solar cell array by photovoltaic power conversion. A life time of space program depends on its mission considering parts reliability and parts grade. Based on the mission life time, power equipment might be designed to meet specifications. In outer space, solar cell array might generate the dc power by photovoltaic conversion effects and GaInP/GaAs/Ge solar cells are used in this study. Space programs that require more than five years should select parts for high reliability applications. Therefore, reliability analysis for high reliability applications should be performed to check its fulfilment of the requirements. This program should also require more five years for its mission and we performed its analysis using parts count method (PCM) for its reliability. Finally, we performed reliability analysis and obtained quantitative figures found out 99.9%. In this study, we presented the reliability analysis of the 300 W GaInP/GaAs/Ge solar cell array.

A study on the Composition of the Production Rates System to Prepare Standards for Calculating the Construction Cost of PC Structure Apartments Based on Off-Site Construction (OSC) (OSC 기반 PC구조 공동주택 공사비 산정기준 마련을 위한 품셈 체계 구성에 관한 연구)

  • Lee, Hansoo;Lee, Chiho;Lee, Jeongwook;Noh, Hyunseok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.6
    • /
    • pp.96-106
    • /
    • 2021
  • The PC structure based on the OSC (Off-Site Construction) is mentioned as a representative method of innovation in the construction industry that converts the existing construction environment from site-centered to factory production-transportation-site assembly. However, recent research on PC method has focused on improving the functions of subsidiary materials and improving the production system to increase productivity and institutional / policy R&D that can be universally applied to the life-cycle stage of ordering / design /construction is insufficient. In particular, the absence of standardized cost calculation standards makes it difficult to calculate and verify of objectified appropriate construction cost. So which is an obstacle to the activation of the PC method. In this study, the standards for construction costs of domestic and foreign PC method were surveyed and similar Construction Standard Production Rates were analyzed to confirm the product structure suitable for PC method. Subsequently, the construction procedures and input resources for each PC subsidiary materials were identified through on-site surveys to derive component for subsidiary materials, and the factors of change in the product according to the construction characteristics(height, weight of subsidiary material) were verified. As a result the standard product calculation system suitable for the site installation of the PC method for apartment was presented.

A Study on a Model Parameter Compensation Method for Noise-Robust Speech Recognition (잡음환경에서의 음성인식을 위한 모델 파라미터 변환 방식에 관한 연구)

  • Chang, Yuk-Hyeun;Chung, Yong-Joo;Park, Sung-Hyun;Un, Chong-Kwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.112-121
    • /
    • 1997
  • In this paper, we study a model parameter compensation method for noise-robust speech recognition. We study model parameter compensation on a sentence by sentence and no other informations are used. Parallel model combination(PMC), well known as a model parameter compensation algorithm, is implemented and used for a reference of performance comparision. We also propose a modified PMC method which tunes model parameter with an association factor that controls average variability of gaussian mixtures and variability of single gaussian mixture per state for more robust modeling. We obtain a re-estimation solution of environmental variables based on the expectation-maximization(EM) algorithm in the cepstral domain. To evaluate the performance of the model compensation methods, we perform experiments on speaker-independent isolated word recognition. Noise sources used are white gaussian and driving car noise. To get corrupted speech we added noise to clean speech at various signal-to-noise ratio(SNR). We use noise mean and variance modeled by 3 frame noise data. Experimental result of the VTS approach is superior to other methods. The scheme of the zero order VTS approach is similar to the modified PMC method in adapting mean vector only. But, the recognition rate of the Zero order VTS approach is higher than PMC and modified PMC method based on log-normal approximation.

  • PDF