• Title/Summary/Keyword: PCCR

Search Result 4, Processing Time 0.016 seconds

A Study of the Atrial Arrhythmia Diagnosis Algorithm (심방성 부정맥 진단 알고리즘에 관한 연구)

  • 황선철
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.17-24
    • /
    • 1989
  • This papaer presents a new algorithm for the P-wave detection in the ECG signal. Digital differentiation method (7-point derivative) is used for detecting P-waves exactly. This algorithm can detect various parameters of PR, PP, RR interval, which are important to diagnosis AV blocks and WPW syndrome. Especially, this algorithm can detect P-waves very efficiently not only in well-preprocessed waves but in pccr waves with noise and artifact. And it enables to develope more reliable automatic diagnosis algorithm.

  • PDF

PCCR(ECCP) Design of Great Man-made River Project (GMR 공사에 적용된 PCCP(EC)의 설계)

  • 김영수;최인식;신경수;김두영;이원재
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.686-693
    • /
    • 1998
  • Prestressed Concrete Cylinder Pipe(PCCP) is used in water transmission pipeline of the Great Man-made River Project(GMR Project). In domestic area, PCCP is used for water cooling systems of Uljin and Youngkwang nuclear power plants. In abroad, especially in the United States and Canada PCCP supplies virtually every metropolitan area with raw and treated water. Compared with other pipe types, PCCP manufacturing cost is dear. But total cost can be considered as economical due to low installation and maintenance cost. Previously, the designs of PCCP were generally determined from one of two appendices in American Water Works Association(AWWA)standard C301 which provided two design methods-cubic parabola design method and stress analysis design method. In 1992, the design procedure for PCCP expanded from two alternatives to the most huge and complex AWWA standard C304. Because C304is so large, it takes too much time for the engineer to read and understand the design concepts and procedures. In this paper, the AWWA C304 design procedures are segmented into simple, understandable sections and concepts and explained. Each section or concepts is compared to the previous design procedure to highlight the revisions and reasons for them. Also the PCCP design program was developed and the design program results are compared with the calculations of the GMR project design consultant.

  • PDF

Technical Survey on the Real Time Eye-tracking Pointing Device as a Smart Medical Equipment (실시간 시선 추적기반 스마트 의료기기 고찰)

  • Park, Junghoon;Yim, Kangbin
    • Smart Media Journal
    • /
    • v.10 no.1
    • /
    • pp.9-15
    • /
    • 2021
  • The eye tracking system designed in this paper is an eye-based computer input device designed to give an easy access for those who are uncomfortable with Lou Gehrig's or various muscle-related diseases. It is an eye-based-computer-using device for users whose potential demand alone amounts to 30,000. Combining the number of Lou Gehrig's patients in Korea estimated at around 1,700, and those who are unable to move their bodies due to various accidents or diseases. Because these eye input devices are intended for a small group of users, many types of commercial devices are available on the market. It is making them more expensive and difficult to use for these potential users, less accessible. For this reason, each individual's economic situation and individual experience with smart devices are slightly different. Therefore, making it difficult to access them in terms of cost or usability to use a commercial eye tracking system. Accordingly, attempts to improve accessibility to IT devices through low-cost but easy-to-use technologies are essential. Thus, this paper proposes a complementary superior performance eye tracking system that can be conveniently used by far more people and patients by improving the deficiencies of the existing system. Through voluntary VoCs(Voice of Customers) of users who have used different kinds of eye tracking systems that satisfies it through various usability tests, and we propose a reduced system that the amount of calculation to 1/15th, and eye-gaze tracking error rate to 0.5~1 degree under.

A Study on Eye Tracking Techniques using Wearable Devices (웨어러블향(向) 시선추적 기법에 관한 연구)

  • Jaehyuck Jang;Jiu Jung;Junghoon Park
    • Smart Media Journal
    • /
    • v.12 no.3
    • /
    • pp.19-29
    • /
    • 2023
  • The eye tracking technology is widespread all around the society, and is demonstrating great performances in both preciseness and convenience. Hereby we can glimpse new possibility of an interface's conduct without screen-touching. This technology can become a new way of conversation for those including but not limited to the patients suffering from Lou Gehrig's disease, who are paralyzed each part by part of the body and finally cannot help but only moving eyes. Formerly in that case, the patients were given nothing to do but waiting for the death, even being unable to communicate with there families. A new interface that harnesses eyes as a new means of communication, although it conveys great difficulty, can be helpful for them. There surely are some eye tracking systems and equipment for their exclusive uses on the market. Notwithstanding, several obstacles including the complexity of operation and their high prices of over 12 million won($9,300) are hindering universal supply to people and coverage for the patients. Therefore, this paper suggests wearable-type eye tracking device that can support minorities and vulnerable people and be occupied inexpensively and study eye tracking method in order to maximize the possibility of future development across the world, finally proposing the way of designing and developing a brought-down costed eye tracking system based on high-efficient wearable device.