• Title/Summary/Keyword: PATCH

Search Result 3,504, Processing Time 0.035 seconds

Design of patch antenna for 2.64GHz S-DMB applications (2.64GHz S-DMB용 패치 안테나 설계)

  • Park, Yong-Wook
    • Journal of the Korea Computer Industry Society
    • /
    • v.10 no.4
    • /
    • pp.121-126
    • /
    • 2009
  • In this paper, the patch antenna for 2.64GHz S-DMB applications has been studied. The patch antenna was designed by HFSS (High Frequency Structural Simulator) program and the optimized antenna was fabricated using photolithography method on the FR-4 substrate. To find optimal conditions of microstrip patch antenna, design parameters with different patch size, length of feedline and metal thickness were analyzed.

  • PDF

Bioequivalence of Nicotine Patches (니코틴 패취제의 생물학적 동등성 평가)

  • 배준호;박은석;지상철
    • Biomolecules & Therapeutics
    • /
    • v.5 no.3
    • /
    • pp.260-264
    • /
    • 1997
  • The bioequivalence of two nicotine patches was evaluated in 16 normal male volunteers (age 21 ~ 27 yrs) following single transdermal application. Test product was "Nicostop patch" made by Sam Yang Co. and reference product was "Nicotinell TTS patch" made by Korean Searle Ciba-Geigy Co. After nicotine patches were applied onto the inside of the forearm, blood was taken at predetermined time intervals and the nicotine concentration in plasma was determined with a sensitive GC method using NPD detector. AUC and Cm\ulcorner were calculated and statistically analyzed for the bioequivalence of the two products. The results showed that the differences in AUC and $C_{msx}$between two products were 5.47% and 2.70%, respectively. The powers (1-$\beta$) for AUC and $C_{max}$. were >90% and 88.76%, respectively. Detectable differences($\Delta$) and confidence intervals were all less than 20%. All of these parameters met the criteria of KFDA for bioequivalence, indicating that "Nicostop patch" is bioequivalent to "Nicotinell TTS patch" . . .

  • PDF

A Study on the Design of Dual-Band Equilateral-Triangular Microstrip Antennas (듀얼-밴드 정삼각형 마이크로스트립 안테나 설계에 관한 연구)

  • 문정군;임정섭;장재삼;윤서용;황호순;이문수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.546-550
    • /
    • 2003
  • For dual-band operation, it can be done by loading two pair of narrow slots in the equilateral-triangular patch, one embedded close to the side edges of the patch and the other inserted at the bottom edge of the patch. The obtained two operating frequencies are of same polarization planes. The frequency ratio of the two operating frequencies is turnabled by varing the positions and lengths of the inserted slots at the bottom edge of the patch. In this paper, A single-feed equilateral-triangular microstrip patch with two pairs of narrow slot for dual-frequency operation is printed on the substrate(TMN-4 Rosers Co.) of the 60 miles. the antenna radiation characteristics are calculated by Ensemble ver. 5.0 software, and compared with the experimental results.

  • PDF

Total correction of TOF using monocusp bearing outflow patch (단일판첨을 내재한 우심실유출로 Patch 를 이용한 활로 4 징증의 교정수)

  • 박이태
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.636-643
    • /
    • 1984
  • For the purpose of avoiding postoperative massive pulmonary insufficiency after transannular outflow tract reconstruction in patients with tetralogy of Fallot, we have used monocusp bearing outflow patch since June 1983. Right heart catheterization and pulmonary arteriography were performed in 7 patients among the total 11 patients corrected with monocusp bearing outflow patch during postoperative 14th day to 22nd day. Particular attention was paid to the evaluation of the pulmonary valve competence, and the results were; 1.One patient died of acute renal failure secondary to low cardiac output and the operative mortality was 9.1%. 2.The average PRV/FA ratio was 0.491 and the average systolic pressure gradient between right ventricle and pulmonary artery was 17.7mmHg. The average Qp/Qs was 1.13. 3.Inspite of using monocusp bearing outflow patch, the hemodynamic and pulmonary arteriographic results were unsatisfactory in respect to pulmonary valve competence.

  • PDF

Design of Wideband Microstrip Patch Antenna (광대역 마이크로스트립 패치 안테나 설계)

  • Kim, Tae Yong;Lee, Jong-Ig
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.469-470
    • /
    • 2015
  • General microstrip patch antenna has small bandwidth. Also this patch antenna is strongly influenced by the thickness of dielectric substrate and its relative permittivity. In this paper, wideband microstrip patch antenna operating in 2.4GHz ISM band is studied. Input impedance and return loss for designed microstrip patch antenna by using MoM method and is estimated.

  • PDF

Estimation of Microstrip Patch Antenna corresponding to Feed Positions (마이크로스트립 패치 안테나의 급전 위치에 따른 평가)

  • Kim, Tae Yong;Lee, Jong-Ig
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.473-474
    • /
    • 2015
  • General microstrip patch antenna has small bandwidth. Input impedance of patch antenna corresponding to feed positions and its feed model is strongly varied. In this paper, wideband microstrip patch antenna operating in 2.4GHz ISM band is investigated. Using the MoM, the variation with feed position of the input impedance of a patch antenna is estimated.

  • PDF

A Study on the Fatigue Characteristics of Aluminum Repaired by Unidirectional Graphite/Epoxy Composites (일방향 탄소섬유/에폭시 복합재 패치로 보수된 알루미늄의 피로특성에 대한 연구)

  • 김만태;신명근;한운용;이지훈;이경엽
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1386-1388
    • /
    • 2003
  • In this study. the fatigue behavior of cracked aluminum repaired by unidirectional graphite/epoxy composites was experimentally investigated. The aluminum used was 7075-T6 and the patch used was four plied unidirectional ([0]$_4$) composites. The composite patch was adhesively bonded to the cracked aluminum using secondary bonding procedure. Two different specimens of cracked aluminum and cracked aluminum repaired with patch were used in the fatigue tests. Load ratio and the frequency applied in the fatigue tests were 0 and 10 Hz, respectively. The results showed that the fatigue behavior of cracked aluminum was improved by repairing the cracked area with composite patch. Specifically, the specimen repaired by composite patch showed 30% more improved fatigue behavior than regular specimen.

  • PDF

Control Effects of Microbial Products on Pythium Blight, Brown Patch and Dollar Spot of Creeping Bentgrass (Creeping Bentgrass에서 미생물제에 의한 Pythium Blight, Brown Patch 및 Dollar Spot 방제 효과)

  • 황연성;최준수;김영호
    • Korean Journal Plant Pathology
    • /
    • v.12 no.2
    • /
    • pp.237-244
    • /
    • 1996
  • 길항곰팡이 3종(Aspergillus sp. A101, Penicillium sp. B202, Trichoderma sp. C303), 길항세균 3종(Arthrobacter sp. AN303)또는 이들 모두의 혼합균주를 배양하여 creeping bentgrass 양묘장에 처리하여 Pythium blight, brown patch 및 dollar spot의 방제효과를 조사하였다. 또한 길항미생물 6종의 배양액을 살균제와 병용하여 그린에 살포하여 이들 토양병에 대한 방제효과를 조사하였다. 양묘장에서는 미생물의 종류에 관계없이 Pythium blight 억제효과가 커 3회 이상 미생물제 처리시 병이 전혀 발생하지 않았다. 그러나 brown patch와 dollar spot은 미생물제에 의한 방제효과가 크지 않았으며, 살균제에 의해 효과적으로 방제되었다. 미생물제와 살균(Pythium blight 방제용 살균제 제외)를 병용하여 처리한 그린에서는 살균제 단독처리와 비교할 때 brown patch는 유의적으로 억제되었고 Pythium blight와 dollar spot은 차이가 없었다.

  • PDF

Convergence studies for Enriched Free Mesh Method and its application to fracture mechanics

  • Matsubara, Hitoshi;Yagawa, Genki
    • Interaction and multiscale mechanics
    • /
    • v.2 no.3
    • /
    • pp.277-293
    • /
    • 2009
  • The Enriched Free Mesh Method (EFMM) is a patch-wise procedure in which both a displacement field on an element and a stress/strain field on a cluster of elements connected to a node can be defined. On the other hand, the Superconvergent Patch Recovery (SPR) is known to be an efficient post-processing procedure of the finite element method to estimate the error norm at a node. In this paper, we discuss the relationship between solutions of the EFMM and those of the SPR through several convergence studies. In addition, in order to solve the demerit of the smoothing effect on the fracture mechanics fields, we implement a singular stress field to a local patch in the EFMM, and its effectiveness is investigated.

LC/MS/MS Method for the Determination of Lidocaine in Hairless Rat Plasma and Pharmacokinetic Applications of Lidocaine Patch (LC/MS/MS를 이용한 혈장 중 리도카인의 정량 및 리도카인 패치제의 약물동태학적 평가)

  • Hwang, Ji-Yeon;Kim, Chul-Jun;Shin, Young-Hee
    • YAKHAK HOEJI
    • /
    • v.56 no.3
    • /
    • pp.158-163
    • /
    • 2012
  • Lidocaine has been studied for many chronic pain conditions, including postherpetic neuralgia (PHN) and recently it has also been increasingly used in transdermal drug delivery systems. In this study, pharmacokinetics of a lidocaine patch was studied in four hairless male rats. The plasma concentration was determined by a validated LC/MS/MS method after applying a $3{\times}2cm^2$ (30mg) patch for 12 hours. From the plasma lidocaine concentration vs time curves, $AUC_{0-20h}$, Cmax, and Tmax of lidocaine patch were $2,926.32{\pm}335.28ng{\cdot}h/ml$, $256.86{\pm}29.63ng/ml$, and $6.00{\pm}2.31h$, respectively.