• Title/Summary/Keyword: PAK2

Search Result 1,123, Processing Time 0.022 seconds

An Experimental Study on Heat Flow Characteristics of Inflowing Cool Air in the Room (실내(室內) 유입(流入) 냉기(冷氣)의 열유동(熱流動) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Jang, Y.G.;Pak, J.W.;Pak, E.T.
    • Solar Energy
    • /
    • v.18 no.1
    • /
    • pp.57-67
    • /
    • 1998
  • A study on a buoyancy effect by the temperature difference between a inner room air and a inflowing cool air and also by Inlet velocity can contribute greatly to enhance performance of air conditioning system, so the study on the distribution characteristics of inflowed cool air is important to analyze the cool air storage in a room. For this study, in the real-sized model room, the temperature differences between inflowing cool air and inner room air are 10, 20, $30^{\circ}C$, and the inlet velocities of inflowing cool air are 1, 2, 3m/s respectively as dynamic parameters. Also, a anemos and a vane type diffuser are used as inlet geometric conditions. Following conclusions have been obtained through this study. 1) In case of the anemos type diffuser, it is found that a dimensionless temperature profile is low and the distribution of the inflowed cool air is uniform. and also, all diffuusers have a low temperature of the inner room as increasing the inlet velocity. 2) A mixing takes place rapidly in case of the anemos type diffuser when the temperature difference is low ${\Delta}T=10^{\circ}C$ and the inletvelocity is high V=3m/s. and the mixing degree is higher with the anemos type diffuser than the vane.

  • PDF

A STUDY ON MASTICATORY PERFORMANCE AND FUNCTION BY POSTERIOR OCCLUSAL SCHEMES IN COMPLETE DENTURE (총의치의 교합면 형태에 따른 저작 효율 및 기능에 관한 연구)

  • Kwon, Kung-Rock;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.389-423
    • /
    • 1998
  • This investigation was designed to determine the effectiveness of the posterior occlusal schemes on masticatory activity during mastication in complete denture. Twelve edentulous subjects were selected for this study. All subjects had no past history and no functional abnormality on masticatory system and TMjoint. And, they had residual ridge of favorable morphology, firm mucosa and Class I skeletal jaw relationship, Twelve experimental denture with interchangeable occlusions(0-degree teeth, 30-degree teeth, Levin teeth and S-A teeth) were constructed for this study. The masticatory performance was analyzed by means of standard sieve(10, 16, 20, 30sieve), and the electrical activity from selected muscles(Temporalis and Masseter muscle) was recorded simultaneously with electromyography (Bio-Pak system) as the subject masticated test foods (rice, peanut and gum) with four different occlusal schemes. Mandibular movement was, also, measured with Sirognathography(Bio-Pak system). These recordings were performed in immediately, after 1 week and after 2 weeks of insertion of complete denture. The results were as fellows; 1. The average masticatory performance of 0-degree artificial teeth was higher than any other artificial teeth. 2. Masticatory performance in denture wearer was affected preferentially by food and artificial occlusal schemes. 3. During chewing, there was a statistical difference of EMG activity between masseter and temporal muscle(p<0.01). Especially, EMG activity of working masticatory muscle was highly affected by food rather than by artificial occlusal schemes. 4. In denture wearer, the velocity of opening was not affected by food, whereas, the velocity of closing was faster in soft food chewing than in hard food chewing, and the amount of vertical displacement was grater in chewing of soft and large bolus than in chewing of hard and small bolus. However, the amount of lateral displacement showed conversely(p<0.05). 5. It was considered that masticatory performance in denture wearer is not affected by the condition of residual ridge. the history of denture wear, the preference, the adaptation to artificial teeth and the total mesiodistal length of artificial posterior teeth.

  • PDF

Separation and Determination of Acteoside in Pedicularis resupinata var. oppositifolia by Ion Pair Liquid Chromatography (이온쌍 액체 크로마토그래피에 의한 마주송이풀 중의 Acteoside의 분리와 정량)

  • Yun, Young Ja;Yu, Gu Yong
    • Analytical Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.161-166
    • /
    • 1995
  • Determination of acteoside in Pedicularis resupinata var. oppositifolia has been studied using ion pair liquid chromatography. Sample was extracted with 40mL methanol for 4 hrs. The extract was cleaned up by using Sep-Pak $C_{18}$ catridge and 8mL aqueous methanol eluent(methanol 50%, water 50%, phosphate buffer pH=8.0). Its determination was performed by means of IP-HPLC with a Hamilton PRP-1 polystyrene-divinylbenzene reversed phase column($15cm{\times}4.6mm$ i. d., $5{\mu}m$) and an aqueous methanol eluent(methanol 60%, water 40% phosphate buffer pH=8.2) containing of $5.0{\times}10^{-3}M$ tetrabutylammonium bromide. The established method was applied to the sample that was collected in area of Pyung Chang gun. As a result, its content ranges showed to be 0.062~0.076%.

  • PDF

Pretreatment of Fish for the determination of polycyclic aromatic hydrocarbons using alkali digestion (알칼리분해를 이용한 어류 중 다환방향족탄화수소의 전처리방법)

  • Hu, Soojung;Lee, Hyomin;Chae, Youngzoo;Yoo, Eun-Ah
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.403-409
    • /
    • 2005
  • Polycyclic Aromatic Hydrocarbons(PAHs) contamination arises from several sources including processing of food(smoking, direct drying, cooking) and environmental contamination of air, water, or soil, the later being considered as the most important. In this study, to establish the analytical method for some PAHs[benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene, indeno(1,2,3-c,d)pyrene] in fish, alkali digestion time, extraction solvents, elution volume of florisil cartridge for clean-up have been optimized. The methodology involved saponification and extraction with n-hexane, clean-up on Sep-Pak florisil cartridges and determination by HPLC/FLD(High Performance Liquid Chromatography/Fluorescence Detector). Overall method recoveries for 8 PAHs spiked into these products ranged from 90 to 106%.

A study on the Rotational Torque Movement of Mandible in TMJ Closed Lock (폐구성 악관절 과두걸림환자의 하악회전운동에 관한 연구)

  • Kim, Kyoung;Chung, Sung-Chang;Yeon, Tae-Ho
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.2
    • /
    • pp.207-217
    • /
    • 1997
  • This study was performed for Investigation of the magnitude of mandibular positional change in maximum mouth opening. protrusion, lateral excursion, gum and peanut chewing with BioPAK system(Bioresearch Inc. USA) which can analyze mandibular rotational torque movements. For this study 17 female patients with Temporomandibular joint(TMJ) closed lock and 18 female control without any Temporomandibular disorders(TMDs) signs and premature occlusal contact were included. The obtained results were as follows : 1. In maximum mouth opening, the mandibular rotational angle and distance of patients were significantly greater than those of control group in horizontal plane(P<0.05). 2. In protrusion, the mandibular rotational angle and distance of patients were significantly greater than those of control group in frontal and horizontal plane(P<0.01, P<0.05). 3. The mandibular rotational angle and 야stance in lateral excursion to affected side of patients were significantly greater than those in lateral excursion to non-affected side in frontal plane(P<0.05). 4. The mandibular rotational angle in gum chewing to affected side of patients was significantly greater than that in gum chewing to non-affected side in frontal plane. 5. The mandibular rotational angle and distance in peanut chewing to affected side of patients were significantly greater than those in peanut chewing to non-affected side in frontal and horizontal plane. 6. The mandibular rotational angle and distance in peanut chewing to affected side of patients were greater than those in gum chewing, and was the same result in control group in frontal and horizontal plane.

  • PDF

Analysis of Preservatives in Flavor-Containing Foods (향기성분이 있는 식품의 보존료 분석)

  • Kim, Jin-Ho;Kim, Hyeon-Wee;Cha, Ik-Soo;Lee, Yoon-Kyoung;Park, Ki-Moon
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.1033-1037
    • /
    • 1996
  • An attempt was made to analyze preservatives in flavor-containing curry and tomato ketchup without interference due to their of flavor components. Samples were steam-distillated and extracted with ether. Sorbic acid, benzoic acid, dehydroacetic acid and salicylic acid were analyzed by GC with capillary column. Benzoic acid and dehydroacetic acid in curry were interfered by flavor components, but there was no interference in case of tomato ketchup. Samples were pretreated with Sep-Pak $C_{18}$ cartridge and analyzed with HPLC to avoid any interference due to flavor components. The recoveries by HPLC were higher than those by GC. Recoveries of sorbic acid, benzoic acid and salicylic acid from curry were 79.9%, 71.2% and 64.4%, respectively. Recoveries of sorbic acid, benzoic acid and salicylic acid from tomato ketchup were 83.4%, 87.8% and 77.7%, respectively.

  • PDF

A STUDY ON MASTICATORY PERFORMANCE AND FUNCTION BY POSTERIOR OCCLUSAL SCHEMES IN COMPLETE DENTURE (총의치의 교합면 형태에 따른 저작 효율 및 기능에 관한 연구)

  • Kwon, Kung-Rock;Park, Nam-Soo;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.539-573
    • /
    • 1996
  • This investigation was designed to determine the effectiveness of the posterior occlusal schemes on masticatory activity during mastication in complete denture. Twelve edentulous subjects were selected for this study. All subjects had no past history and no functional abnormality on masticatory system and TMjoint. And, they had residual ridge of favorable morphology, firm mucosa and Class I skeletal jaw relationship, Twelve experimental denture with interchangeable occlusions(0-degree teeth, 30-degree teeth, Levin teeth and S-A teeth) were constructed for this study. The masticatory performance was analyzed by means of standard sieve(10, 16, 20, 30sieve), and the electrical activity from selected muscles(Temporalis and Masseter muscle) was recorded simultaneously with electromyography(Bio-Pak system) as the subject masticated test foods (rice, peanut and gum) with four different occlusal schemes. Mandibular movement was, also, measured with Sirognathography(Bio-Pak system). These recordings were performed in immediately, after 1 week and after 2 weeks of insertion of complete denture. The results were as follows; 1. The average masticatory performance of 0-degree artificial teeth was higher than any other artificial teeth. 2. Masticatory performance in denture wearer was affected preferentially by food and artificial occlusal schemes. 3. During chewing, there was a statistical difference of EMG activity between masseter and temporal muscle(p<0.01). Especially, EMG activity of working masticatory muscle was highly affected by food rather than by artificial occlusal schemes. 4. In denture wearer, the velocity of opening was not affected by food, whereas, the velocity of closing was faster in soft food chewing than in hard food chewing, and the amount of vertical displacement was grater in chewing of soft and large bolus than in chewing of hard and small bolus. However, the amount of lateral displacement showed conversely (p<0.05). 5. It was considered that masticatory performance in denture wearer is not affected by the condition of residual ridge, the history of denture wear, the preference, the adaptation to artificial teeth and the total mesiodistal length of artificial posterior teeth.

  • PDF

SECTIONAL CURVATURE OF CONTACT C R-SUBMANIFOLDS OF AN ODD-DIMENSIONAL UNIT SPHERE

  • Kim, Hyang-Sook;Pak, Jin-Suk
    • Bulletin of the Korean Mathematical Society
    • /
    • v.42 no.4
    • /
    • pp.777-787
    • /
    • 2005
  • In this paper we study (n + 1)-dimensional compact contact CR-submanifolds of (n - 1) contact CR-dimension immersed in an odd-dimensional unit sphere $S^{2m+1}$. Especially we provide necessary conditions in order for such a sub manifold to be the generalized Clifford surface $$S^{2n_1+1}(((2n_1+1)/(n+1))^{\frac{1}{2}})\;{\times}\;S^{2n_2+1}(((2n_2+1)/(n+1)^{\frac{1}{2}})$$ for some portion (n1, n2) of (n - 1)/2 in terms with sectional curvature.

A Study on the Reaction Mechanism of Selective Epitaxial Growth in $SiH_2Cl_2-H_2-HCl$ System ($SiH_2Cl_2-H_2-HCl$ 시스템에서의 실리콘 선택적 성장에 대한 표면 반응메커니즘 고찰)

  • Kim, Bong-Soo;Han, Seung-Oh;Pak, James Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1288-1290
    • /
    • 1998
  • Three most dominant reactions are adsorption, movement, and desorption of $SiCl_2$ on silicon surface. $SiCl_2$ plays a key role in these dominant reactions. In this paper, surface reactions of $SiH_2Cl_2-H_2-HCl$ system are investigated and few dominant reactions were identified. An equation for Si net growth rate is derived from the analysis of these reactions and it is compared with experimental results of Bolem and Classen.

  • PDF

Determination of several families of antibacterial agent residues in fish by disk assay (미생물학적 방법에 의한 어체내 잔류 항균물질의 계열별 동정시험)

  • Jung, Sung-Hee;Kim, Jin-Woo
    • Journal of fish pathology
    • /
    • v.10 no.2
    • /
    • pp.125-135
    • /
    • 1997
  • The possibility of identification of families of antibacterial agent residues in fish tissue was studied by disk assay using three test organisms, Bacillus subtilis BGA, Micrococcus luteus ATCC 9341, and Bacillus cereus var. mycoides ATCC 11778. In the present method, a simple clean-up procedure was performed to obtain the aqueous solution from homogenized flounder muscle sample(10g) in Mcilvaine buffer. Then, aqueous solution was fractionated into A and B to be used in disk assay by choloroform and Sep-Pak $C_{18}$ cartridge column after being defatted in hexane. The chloroform layer of fraction A was used for the analysis of macrolide antibiotics(ML), sulfa drugs(SA), chloramphenicol(CP), and quinolone antibiotics(QN). Adsorbed materials to Sep-Pak $C_{18}$ of fraction B were also employed for the analysis of penicillins(PC), tetracyclines(TC), and nitrofuran derivatives(NF) Minimun-detectable concentrations by the present method were, $0.1{\mu}g$/g for oxytetracycline, tetracycline, doxycycline, spiramycin and ciprofloxacin, $0.025{\mu}g$/g for erythromycin and ampicillin, $1.0{\mu}g$/g for sodium nifurstyrenate and florfenical, $0.25{\mu}g$/g for sulfamonomethoxie and sulfadimethoxine, $2.5{\mu}g$/g for oxolinic acid and flumequine, and $15{\mu}g$/g for piromidic acid, respectively. Three test organisms showed different sensitivity patterns for each family of antibacterial agent. Sensitivity patterns were B. cereus > B. subtilis > M. luteus for TC and NF, M. luteus > B, subtilis > B. cereus for ML and PC, B. cereus = B. subtilis > M. luteus for CP and QN, and B. subtilis > B. cereus=M. luteus for SA. The present method utilizing these characteristics could be useful as a routine screening test for the determination of family of antibacterial agent residues in fish tissue.

  • PDF