• Title/Summary/Keyword: P2P Grid

Search Result 203, Processing Time 0.03 seconds

Prediction of Species Richness of Breeding Birds by Analysis of Land Cover at Seongnam City, Korea

  • Park, Chan-Ryul;Lee, Jang-Ho;Lee, Do-Won;Lee, Woo-Shin
    • The Korean Journal of Ecology
    • /
    • v.28 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • This study was conducted to develop the predictive model for species richness of breeding birds by multivariate analysis of land covers (percentage value of each cover in 300 $\times$ 300m grid) including water area (WA), urbanized area (UA), green area (GA), forest area (FA) and agricultural area (AA) at Seongnam City in Korea. Fifty-nine species of birds were mapped on 155 grids in size of 300 $\times$ 300 m from 2000 to 2001. Species richness of breeding birds was significantly regressed ($R^2=0.85$, n=155) by estimates of WA ($4.59{\pm}1.13$, P<0.0001), UA ($6.50{\pm}0.86$, P<0.0001), GA ($7.11{\pm}1.25$, P<0.0001), FA ($8.51{\pm}0.62$, P<0.0001), and AA ($4.59{\pm}1.13$, P<0.0001). In validation of model, the results show no significant difference between predicted value of species richness and observed one. Developed model can be used as a predictive model of species richness of birds for selecting the proper location of corridors and parks in urban area.

Implementation of REST Web Sorvics in Korea@Home Desktop Grid System (Korea@Home 데스크톱 그리드 시스템에서 REST 웹 서비스 구현)

  • Han, Chang-Hwan;Han, Youn-Hee;Gil, Joon-Min;Kang, Sang-Won;Choi, Jang-Won
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.10d
    • /
    • pp.456-461
    • /
    • 2007
  • 기존의 P2P기반의 분산컴퓨팅 시스템을 일반 응용수행자가 사용하기 위해서는 수동적으로 시스템에 위탁하여 수행하여 왔다. 이러한 구조에서 응용수행자가 자신이 원하는 응용을 계산도구로서 분산컴퓨팅 시스템을 활용하여 수행하고 최종 결과를 받아오는 것은 복잡하고 어려운 과정이었다. 본 논문에서는 이러한 과정을 간편화하고 분산컴퓨팅 시스템의 참여도를 높이기 위하여 웹 서비스 Open API를 사용한 개방형 분산컴퓨팅 시스템을 구현하였다. 본 논문은 국내의 P2P기반 분산컴퓨팅 시스템인 Korea@Home 데스크톱 그리드 시스템을 소개하고 이 시스템에서 효율적으로 Open API를 제공하기 위하여 REST 웹 서비스를 구현하고 응용수행자의 편의를 위한 인터페이스로 자바 클래스를 제공하였다. 응용수행자는 제공되는 인터페이스를 통하여 간단한 프로그래밍 지식으로 Korea@Home 데스크톱 그리드 시스템을 웹 서비스 방식으로 이용할 수 있다.

  • PDF

Efficient 3D Acoustic Wave Propagation Modeling using a Cell-based Finite Difference Method (셀 기반 유한 차분법을 이용한 효율적인 3차원 음향파 파동 전파 모델링)

  • Park, Byeonggyeong;Ha, Wansoo
    • Geophysics and Geophysical Exploration
    • /
    • v.22 no.2
    • /
    • pp.56-61
    • /
    • 2019
  • In this paper, we studied efficient modeling strategies when we simulate the 3D time-domain acoustic wave propagation using a cell-based finite difference method which can handle the variations of both P-wave velocity and density. The standard finite difference method assigns physical properties such as velocities of elastic waves and density to grid points; on the other hand, the cell-based finite difference method assigns physical properties to cells between grid points. The cell-based finite difference method uses average physical properties of adjacent cells to calculate the finite difference equation centered at a grid point. This feature increases the computational cost of the cell-based finite difference method compared to the standard finite different method. In this study, we used additional memory to mitigate the computational overburden and thus reduced the calculation time by more than 30 %. Furthermore, we were able to enhance the performance of the modeling on several media with limited density variations by using the cell-based and standard finite difference methods together.

Implementation and performance analysis of authentication and key exchange protocol with post-quantum cryptography in grid computing system (그리드 컴퓨팅 시스템에서의 양자내성암호 기반 사용자 인증 및 키 교환 프로토콜 구현 및 성능 측정)

  • Jae-Yeong Han;Je-Hyun Hwang;Jae-Seok Lee;Young-Jun Lee;In-Hee Lee;Je-Won Lee;Sung-Wook Kim
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2024.01a
    • /
    • pp.427-430
    • /
    • 2024
  • 본 논문에서는 그리드 컴퓨팅에서의 안전한 통신을 위한 양자내성암호 기반 사용자 인증 및 키 교환 프로토콜을 구현하고 성능을 측정한다. 디지털 서명을 통해 사용자를 검증하고 암호키를 교환하여 신뢰할 수 있는 사용자들만이 그리드 컴퓨팅에 참여할 수 있도록 한다. 사용자 인증과 키 교환 과정에 NIST 선정 표준양자내성암호인 ML-DSA와 ML-KEM을 적용하여 양자컴퓨터를 이용한 공격에도 안전할 것으로 기대된다. 본 논문에서는 양자내성암호를 적용한 프로토콜이 기존의 현대암호 기반 전자서명이나 키 교환 과정에 비해 양자내성과 동시에 준수한 사용성을 지녔음을 보인다. 이를 통해 그리드 컴퓨팅의 시스템의 P2P 특성에서 기인하는 보안 문제를 해결하고, 기존에 주로 내부망이나 실시간 스트리밍 서비스에서 활용되던 그리드 컴퓨팅의 인터넷 환경으로의 확장 가능성을 제시한다.

  • PDF

Dose and Image Assessment according to Radiologic Factors Variation at Digital Humerus X-ray Examination (디지털 환경에서 Humerus 검사 시 촬영인자 변화에 따른 선량 및 화질 평가)

  • Kim, Seong Min;Hong, Seon Sook;Lee, Kwan Sup;Ha, Dong Yun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose : We aim at presenting the optimum radiologic factor through the evaluation of dose variation and of image quality through the use of a grid in Humerus examination and the change of dose because of the change of radiologic factor. Materials and Methods : We divided it in 3 cases: when using a grid or not and when using IP(Image Plate) in a digital system. Also, as fixing kVp to 70kVp it changed mAs, and fixing mAs to 10 it changed kVp, we put up resolution chart and Burger rose phantom on the acrylic phantom of 7cm (the same level of Humerus) to evaluate the dose and image. We used Image J program to evaluate the quantitative resolution of the obtained image, and made the qualitative evaluation and statistical analysis of the image saved in PACS for 20 radiologic technologist with more than 10 years of experience in order of evaluate its contrast. We used SPSS10(SPSS Inc. Chicago, Illinois) for statistical analysis. Results : We observed the analytic result of resolution by the change of kVp that it was $4.539dGycm^2$ in 60kVp and $757.472dGycm^2$ in 75kVp, which increased about 64.6% of dose, while for the resolution it had the pixel value 30.7% better with 851 in 60kVp than 651 in 75kVp. Also, we analyzed the result of resolution by the change of mAs that it was $3.106dGycm^2$ in 5mAs, and $12.470dGycm^2$ in 20mAs, which increased about 400% of dose, while for the resolution DR had 678 in 5mAs, and 724 in 20mAs that increased about 6.8% of resolution. We made the qualitative evaluation of contrast by the change of kVp that DR showed the higher quality than CR, but the contrast by the change of kVp had no special different at the moment of visual evaluation, nor statistically significant difference(P>0.05). We observed the qualitative evaluation of contraste by the change of mAs that the contrast increased as DR increased mAs, and had statistically significant difference(P<0.05). On the other hand, CR had no significant difference for more than 10mAs nor statistically significant difference(P>0.05). Conclusion : In case of some patients with radiographic exposure by the repeated examination such as emergent patient or Follow up patient, they are considered to try to limit the use of a grid, to set kVp under 65kVp in fixed mode, to select less than 10mAs and to reduce the possibility of patient being bombed.

  • PDF

The MPPT Control Method of the PMSG Wind Generation System using the Turbine Model with a Squirrel Cage Induction Motor (농형 유도기 터빈 모델을 이용해 구현한 영구자석 동기기 풍력발전 시스템의 MPPT 제어)

  • Lee, Joon-Min;Kim, Dong-Hwa;Shin, Hye-Su;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.231-236
    • /
    • 2012
  • This paper presents the MPPT(Maximum Power Point Tracking)control method of the PMSG wind generation system using the turbine model with a squirrel cage induction motor. The torque of squirrel cage induction turbine model is controlled by mathematization of speed characteristics of real blade. In this paper, maintenance and cost issues into consideration, except for previous method using information of the velocity of the wind speed sensor, the algorithm is presented. The algorithm is controlled by tracking the optimal point, the generator speed and maximum grid power. The vector controls of the generator side converter and the grid side converter are controlled respectively to obtain maximum torque and regulate unity power factor. With Psim simulations and experiments, the efficiency of squirrel cage induction turbine model and the validity of control algorithm are verified.

Rat Magnetocardiograms Measured by YBCO SQUID Magnetometer (YBCO SQUID를 이용한 실험쥐의 심자도 측정)

  • Ahn, San;Kim, I.S.;Song, J.H.
    • Progress in Superconductivity
    • /
    • v.12 no.2
    • /
    • pp.124-128
    • /
    • 2011
  • We have developed a high-$T_C$ SQUID magnetometer system to measure magnetocardiograms of laboratory rats. White noise of the measurement system was about 50 fT/$Hz^{1/2}$ when measured in a magnetically shielded box. We optimized the measurement position to obtain clear MCG wave from rat's small heart by using grid measurements. With the optimization, the MCG signal was successfully detected with the peak amplitude of about 50 pT. We could observe well defined P-, QRS-, and T-wave from the rat MCG. The results suggest that the developed system has a strong potential to monitor the progress of heart disease model using laboratory rat.

Magnetocardiogram Measurement of Laboratory Rat (백서를 이용한 심자도 신호 측정)

  • Kim, I.S.;Ahn, San;Kwon, H.C.;Song, J.H.
    • Progress in Superconductivity
    • /
    • v.11 no.2
    • /
    • pp.147-151
    • /
    • 2010
  • We have developed a high-$T_c$ SQUID magnetocardiogram (MCG) system for small laboratory animals. White noise of the measurement system was about 30 fT/$Hz^{1/2}$ when measured in a magnetically shielded room. We optimized the measurement position to obtain clear MCG wave from rat's small heart by using grid measurements. With the optimization, the MCG signal was successfully detected with the peak amplitude of about 30 pT. We could observe well defined P-, QRS-, and T-waves from the rat MCG. The results suggest that the developed system has a strong potential to monitor the progress of the heart disease model by using a laboratory rat.

Enhanced Controller Topology for Photovoltaic Sourced Grid Connected Inverters under Unbalanced Nonlinear Loading

  • Sivakumar, P.;Arutchelvi, Meenakshi Sundaram
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.369-382
    • /
    • 2014
  • A growing dynamic electrical demand has created an increasing interest in utilizing nonconventional energy sources like Photovoltaic (PV), wind power, etc. In this context, this paper focuses on the design and development of a composite power controller (CPC) in the decoupled double synchronous reference frame (DDSRF) combining the advantages of direct power control (DPC) and voltage oriented control (VOC) for a PV sourced grid connected inverter. In addition, a controller with the inherent active filter configuration is tested with nonlinear and unbalanced loads at the point of common coupling in both grid connected and autonomous modes of operation. Furthermore, the loss and reactive power compensation due to a non-fundamental component is also incorporated in the design, and the developed DDSRF model subsequently allows independent active and reactive power control. The proposed developed model of the controller is also implemented using MATLAB-Simulink-ISE and a Xilinx system generator which evaluate both the simulated and experimental setups. The simulation and experimental results confirm the validity of the developed model. Further, simulation results for the DPC are also presented and compared with the proposed CPC to further bring out the salient features of the proposed work.

Tidal Computation of the Global Ocean using Fine-grid Numerical Model (세격자체계에 의한 전지구 해양 조석 산정)

  • 최병호;서경석
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.1
    • /
    • pp.51-61
    • /
    • 1997
  • A two-dimensional numerical tidal model with $1/3^\circ$ resolution has been established to investigate the distribution of semidiurnal constituents$(M_2,\;S_2,\;K_2,\;N_2)$ and diurnal constituents$(K_1,\;O_1,\;P_1,\;Q_1)$ of the global ocean. The $1/3^\circ$ numerical model has been applied to the computation of detailed tidal distributions in the marginal seas and the shelf seas. Tidal characteristics in shallow areas could be hardly resolved with the existing global chart due to the low resolution. Computed tidal charts obtained by $1/3^\circ$ numerical model have been compared with the existing global charts and the altimetry-derived tidal charts. Computed harmonic constants have also been com-pared with the pelagic tidal observations. The results obtained with fine-grid numerical model can be used to determine the time-independent sea surface topography by removing the tidal components from the altimetry-derived sea surface height.

  • PDF