• Title/Summary/Keyword: P.S.N curve

Search Result 190, Processing Time 0.026 seconds

A Study on the Decomposition of Litter and the Leaching of Mineral Nutrients in the Stands of Pinus rigida on Mt. Gwan-ak and Pseudosasa japonica on Odong-do (관악산의 리기다소나무림과 오동도의 이대림에서 낙엽의 분해와 무기양분의 세탈에 관한 연구)

  • Chang, Nam-Kee;Heui-Baik Kim;Jun-hi Yoo
    • The Korean Journal of Ecology
    • /
    • v.9 no.1
    • /
    • pp.51-58
    • /
    • 1986
  • The decay rates of organic matter were investigated and the leaching rates were determined from the concentration distribution of N,P,K, Ca and Na in the soil profile at Pinus rigida stand on Mt. Gwan-ak and at Pseudosasa japonica stand on Odong-do. In order to determine the leaching rates θo/W wazs substituted with KL in Towner's equation. Decay rates were 0.191 at Pinus stand on Mt. Gwan-ak and 0.234 at Pseudosasa stan don Odong-do. Concentration distributions of N,P, K and Na in soil profiles were corresponed with Towner's model curve. Leaching rates determined from concentration distributions were 0.086, 0.079, 0.041, 0.029, 0.096 on Mt. Gwan-ak and 0.080, 0.056, 0.051, 0.008, 0.028 on Odong-do. The soil of Pseudosasa stand showed on the whole lower leaching rates than that of Pinus stand. The soil of Pseudosasa stand showing higher decay rate and lower leaching rates contained more concentration of each nutrient than that of Pinus stand.

  • PDF

Prediction of Gear Bending Fatigue Life of Electro-mechanical Actuator for Aircraft Through Finite Element Analysis

  • Kim, Taehyung;Seok, Taehyeon;Kwon, Soon-hyeong;Lee, Byung-ho;Kwon, Byung-gi;Kwon, Jun-yong;Cheong, Seong-kyun
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.6
    • /
    • pp.58-67
    • /
    • 2020
  • In this study, finite element fatigue analysis combined with a fatigue correlation factor is proposed to predict the bending fatigue life of a gear in an electro-mechanical aircraft actuator. First, stress-life curves are obtained for the gear material via a round bar fatigue test. Subsequently, stochastic stress-life (P-S-N) curves are derived for 50% and 1% failure probabilities, separately. The curves are applied to the fatigue analysis model of a single gear tooth, and the effect of the fatigue correction factor is analyzed. The analytical P-S-N curves reflecting the fatigue correction factor matched the experimental data. This shows that the analytical fatigue life is reliable and that the analysis technique is effective.

Variations in Tribological Characteristics of SM45C by PVD Coating and Thin Films (SM45C재의 PVD코팅과 필름에 의한 트라이볼러지 특성)

  • Shim, Hyun-Bo;Suh, Chang-Min;Kim, Jong-Hyoung;Suh, Min-Soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.502-510
    • /
    • 2018
  • In order to accumulate data to lower the friction coefficient of a press mold, tribological tests were performed before and after coating SM45C with a PVC/PO film and plasma coating (CrN, concept). The ultrasonic nanocrystal surface modification (UNSM)-treated material had a nano-size surface texture, high surface hardness, and large and deep compressive residual stress formation. Even when the load was doubled, the small amount of abrasion, small weight of the abrasion, and width and depth of the abrasion did not increase as much as those of untreated materials. A comparison of the weight change before and after the tribological test with the CrN and the concept coating material and that of the untreated material showed that the wear loss of the concept coating material and P-UNSM treated material (that is, the UNSM treated material treated with the concept coating) showed a tendency to decrease by approximately 55-75%. Concept 100N had a lower friction coefficient of about 0.6, and P-UNSM-30-100N showed almost the same curve as concept 100N and had a low coefficient of friction of about 0.6. The concept multilayer coating had a thickness of $5.32{\mu}m$. In the beginning, the coefficient of friction decreased because of the plasma coating, but it started to increase from about 250-300 s. After about 350 s, the coefficient of friction tended to approach the friction coefficient of the SM45C base metal. The SGV-280F film-attached test specimen was slightly pushed back and forth, but the SM45C base material was not exposed due to abrasion. The friction coefficient was 0.22, which was the lowest, and the tribological property was the best in this study.

Two Stage Process Mechanism of Silica Adsorption by Soil in Adsoption Kinetics (토양의 규산 흡착 카이네틱에서 2단계 흡착 기작)

  • Lee, Sang-Eun;Jung, Kwang-Yong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.29 no.2
    • /
    • pp.107-112
    • /
    • 1996
  • To clarify the mechanism of silica adsorption to soil, kinetic study using continuous stirred-flow method was conducted with the Luisiana soil at three pH levels (pH 5.0, 6.5, and 8.0). Silica adsorption increased continuously without showing the maximum adsorption for long enough experimental time. Kinetic curve of silica adsorption could be divided into two stage processes. The first stage process was fitted well to the following equation with highly significant correlation coefficient : $$R_{ad}=K_a*(Q_{OH}^S)^n$$ where, $R_{ad}$ is silica adsorption rate($Si\;{\mu}mal/min$). $Q_{OH}^S$ is the negative charge sites on the soil surface created by alkali titration, and $K_a$ and n are constants. The "n" value of the first stage process was 1.1. This value indicates that the silica adsorption is accomplished by the monodendate ligand bonding. The second stage process was fitted well to the following equation : $$R_{ad}=K_b*(pH)$$ where, $K_b$ is a constant. The equation indicates that the silica adsorption is not proportional to the $OH^-$ ion concentration. Rather, the increasing pattern of silica adsorption rate with the increase of $OH^-$ ion concentration would decrease exponentially.

  • PDF

Analysis of the Current-voltage Curves of a Cu(In,Ga)Se2 Thin-film Solar Cell Measured at Different Irradiation Conditions

  • Lee, Kyu-Seok;Chung, Yong-Duck;Park, Nae-Man;Cho, Dae-Hyung;Kim, Kyung-Hyun;Kim, Je-Ha;Kim, Seong-Jun;Kim, Yeong-Ho;Noh, Sam-Kyu
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.321-325
    • /
    • 2010
  • We analyze the current density - voltage (J - V) curve of a Cu(In,Ga)$Se_2$ (CIGS) thin-film solar cell measured at different irradiation power densities. For the solar-cell sample investigated in this study, the fill factor and power conversion efficiency decreased as the irradiation power density (IPD) increased in the range of 2 to 5 sun. Characteristic parameters of solar cell including the series resistance ($r_s$), the shunt resistance ($r_{sh}$), the photocurrent density ($J_L$), the saturation current density ($J_s$) of an ideal diode, and the coefficient ($C_s$) of the diode current due to electron-hole recombination via ionized traps at the p-n interface are determined from a theoretical fit to the experimental data of the J - V curve using a two-diode model. As IPD increased, both $r_s$ and $r_{sh}$ decreased, but $C_s$ increased.

Evaluation of Statistical Fatigue Life of Hybrid Composite Joints in Low-Floor Bus (저상버스용 하이브리드 복합재 조인트부의 통계적 피로수명평가)

  • Jung, Dal-Woo;Choi, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1705-1713
    • /
    • 2010
  • The reliable fatigue life for hybrid composite joint structures was estimated by a statistical method for evaluating fatigue life; the results of the fatigue test varied widely. Cyclic bending tests were performed on a cantilever beam with a hybrid composite joint, which was developed for the body of a low-floor bus. In order to estimate the fatigue life of the hybrid composite joint structure by comparing the data obtained during the fatigue tests, the most suitable probabilistic density function among the normal, lognormal, and Weibull distributions was selected. The probabilistic-stress-life (P-S-N) curves calculated by using the selected Weibull distribution was suggested for process of statistical fatigue life estimation and reliability design.

High Cyclic Fatigue Life and Fracture Behaviors of Shot-Peened Bearing Steel (쇼트피닝 처리를 한 베어링강의 고사이클 피로수명 및 파괴거동)

  • Yoon, Sang-Jae;Choi, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.9
    • /
    • pp.1119-1129
    • /
    • 2011
  • Shot-peening effects on the fatigue behavior of bearing steel were investigated under the high cyclic loading. Hourglass shape specimens were made of bearing steel(JIS-SUJ2) for rotary bending fatigue tests. Two kinds of treatments were performed : a heat treatment and a shot-peened surface treatment after the heat treatment. The fracture surfaces of specimens were classified into two types of fracture mode : the surface fracture mode induced by a surface defect and the internal fracture mode induced by a nonmetallic inclusion. Inclusion depth and shape affected considerably the fatigue life. Shot-peening treatment improved much the fatigue life of the bearing steel under low and high levels of cyclic loads. Probabilistic-stress-life (P-S-N) curves were suggested for the reliable fatigue life estimation of the improved bearing steel.

Prediction of Shearing Die Life for Producing a Retainer using FE Analysis (유한요소해석을 이용한 리테이너 전단 금형 수명예측)

  • Lee, I.K.;Lee, S.Y.;Lee, S.K.;Jeong, M.S.;Seo, P.K.;Lee, K.H.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.24 no.4
    • /
    • pp.264-271
    • /
    • 2015
  • In the current study, a method was proposed to quantitatively predict the wear and fatigue life of a shearing die in order to determine an effective replacement period for the die. The shearing die model of a retainer manufacturing process was used for the proposed method of quantitative life prediction. The retainer is produced through shearing steps, such as piercing and notching. The shearing die of the retainer is carefully controlled because the dimensional accuracy of the retainer is critical. The fatigue life for the shearing die was predicted using ANSYS considering S-N curves of STD11 and Gerber’s equation. The wear life for the shearing die was predicted using DEFORM-3D considering the Archard’s wear model. Experimental shearing of the retainer was conducted to verify the effectiveness of the proposed method for predicting die life. The fatigue failure of the shearing die was macroscopically measured. The wear depth was measured using a 3D coordinate measuring machine. The results showed that the wear and fatigue life in the FE analysis agree well with the experimental results.

Prognostic Value of 18F-FDG PET/CT Radiomics in Extranodal Nasal-Type NK/T Cell Lymphoma

  • Yu Luo;Zhun Huang;Zihan Gao;Bingbing Wang;Yanwei Zhang;Yan Bai;Qingxia Wu;Meiyun Wang
    • Korean Journal of Radiology
    • /
    • v.25 no.2
    • /
    • pp.189-198
    • /
    • 2024
  • Objective: To investigate the prognostic utility of radiomics features extracted from 18F-fluorodeoxyglucose (FDG) PET/CT combined with clinical factors and metabolic parameters in predicting progression-free survival (PFS) and overall survival (OS) in individuals diagnosed with extranodal nasal-type NK/T cell lymphoma (ENKTCL). Materials and Methods: A total of 126 adults with ENKTCL who underwent 18F-FDG PET/CT examination before treatment were retrospectively included and randomly divided into training (n = 88) and validation cohorts (n = 38) at a ratio of 7:3. Least absolute shrinkage and selection operation Cox regression analysis was used to select the best radiomics features and calculate each patient's radiomics scores (RadPFS and RadOS). Kaplan-Meier curve and Log-rank test were used to compare survival between patient groups risk-stratified by the radiomics scores. Various models to predict PFS and OS were constructed, including clinical, metabolic, clinical + metabolic, and clinical + metabolic + radiomics models. The discriminative ability of each model was evaluated using Harrell's C index. The performance of each model in predicting PFS and OS for 1-, 3-, and 5-years was evaluated using the time-dependent receiver operating characteristic (ROC) curve. Results: Kaplan-Meier curve analysis demonstrated that the radiomics scores effectively identified high- and low-risk patients (all P < 0.05). Multivariable Cox analysis showed that the Ann Arbor stage, maximum standardized uptake value (SUVmax), and RadPFS were independent risk factors associated with PFS. Further, β2-microglobulin, Eastern Cooperative Oncology Group performance status score, SUVmax, and RadOS were independent risk factors for OS. The clinical + metabolic + radiomics model exhibited the greatest discriminative ability for both PFS (Harrell's C-index: 0.805 in the validation cohort) and OS (Harrell's C-index: 0.833 in the validation cohort). The time-dependent ROC analysis indicated that the clinical + metabolic + radiomics model had the best predictive performance. Conclusion: The PET/CT-based clinical + metabolic + radiomics model can enhance prognostication among patients with ENKTCL and may be a non-invasive and efficient risk stratification tool for clinical practice.

Correction of Single Thoracic Adolescent Idiopathic Scoliosis Using Pedicle Screw Instrumentation: Comparison of Stainless Steel to Titanium Alloy Instruments (척추경 나사못 고정술을 이용한 단일 흉추 청소년기 특발성 척추 측만증의 치료: 스테인리스강과 티타늄 합금 기기의 비교)

  • Kim, Sung-Soo;Lim, Dong-Ju;Kim, Jung-Hoon;Choi, Byung-Wan;Kim, Hwi-Young;Lee, Jun-Seok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.2
    • /
    • pp.141-149
    • /
    • 2019
  • Purpose: To compare the results of two different instruments made of stainless steel and titanium alloy for correction of single thoracic adolescent idiopathic scoliosis (AIS) using pedicle screw instrumentation. Materials and Methods: A total of 141 patients with single thoracic AIS treated with pedicle screw instrumentation and selective thoracic fusion were retrospectively reviewed after a follow-up of 2 years. The patients had a main thoracic curve of 40° to 75° and were divided into two groups based on instrument materials; S group (stainless steel, n=90) and T group (titanium alloy, n=51). The diameter of the stainless steel rod used was 7.0 mm while that of the titanium alloy rod was 6.35 mm or 6.0 mm. Standing long-cassette radiographic measurements including various coronal and sagittal parameters for the preoperative, early postoperative and 2-year postoperative followup were analyzed. There were no significant differences in the preoperative curve characteristics between the two groups. Results: In the S group, the preoperative main thoracic curve of 51.3°±8.4° was improved to 19.0°±7.6° (63.1% correction) and the lumbar curve of 32.3°±8.4° spontaneously decreased to 12.7°±8.2° (62.9% correction) at 2 years postoperatively. In the T group, the preoperative main thoracic curve of 49.5°±8.4° and the lumbar curve of 30.3°±8.9° was improved to 18.8°±7.4° (62.2% correction) and 11.3°±5.4° (63.3% correction), respectively. The corrections of coronal curves were not statistically different between the two groups (p>0.05). The thoracic kyphosis was changed from 16.8°±8.5° to 24.3°±6.1° in the S group and from 19.6°±11.2° to 26.6°±8.5° in the T group. There were no significant differences in the changes of sagittal curves, coronal and sagittal balances at the 2-year follow-up and the number of fused segments and used screws between the two groups (p>0.05). Conclusion: When conducting surgery for single thoracic AIS using pedicles screw instrumentation, two different instruments made of stainless steel and titanium alloy showed similar corrections for coronal and sagittal curves.