• Title/Summary/Keyword: P-wave Noise

Search Result 88, Processing Time 0.029 seconds

Automatic Noise Removal and Peak Detection Algorithm for ECG Measured from Capacitively Coupled Electrodes Included within a Cloth Mattress Pad (침대 패드 형태의 용량성 전극에서 측정된 심전도 신호를 처리하기 위한 자동 잡음 제거 및 피크 검출 알고리즘)

  • Lee, Won Kyu;Lee, Hong Ji;Yoon, Hee Nam;Chung, Gih Sung;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.87-94
    • /
    • 2014
  • Recent technological advances have increased interest in personal health monitoring. Electrocardiogram(ECG) monitoring is a basic healthcare activity and can provide decisive information regarding cardiovascular system status. In this study, we developed a capacitive ECG measurement system that can be included within a cloth mattress pad. The device permits ECG data to be obtained during sleep by using capacitive electrodes. However, it is difficult to detect R-wave peaks automatically because signals obtained from the system can include a high level of noise from various sources. Because R-peak detection is important in ECG applications, we developed an algorithm that can reduce noise and improve detection accuracy under noisy conditions. Algorithm reliability was evaluated by determining its sensitivity(Se), positive predictivity(+P), and error rate(Er) by using data from the MIT-BIH Polysomnographic Database and from our capacitive ECG system. The results showed that Se = 99.75%, +P = 99.77%, and Er = 0.47% for MIT-BIH Polysomnographic Database while Se = 96.47%, +P = 99.32%, and Er = 4.34% for our capacitive ECG system. Based on those results, we conclude that our R-peak detection method is capable of providing useful ECG information, even under noisy signal conditions.

Atrial Fibrillation Detection Algorithm through Non-Linear Analysis of Irregular RR Interval Rhythm (불규칙 RR 간격 리듬의 비선형적 특성 분석을 통한 심방세동 검출 알고리즘)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.12
    • /
    • pp.2655-2663
    • /
    • 2011
  • Several algorithms have been developed to detect AF which rely either on the form of P waves or the based on the time frequency domain analysis of RR variability. However, locating the P wave fiducial point is very difficult because of the low amplitude of the P wave and the corruption by noise. Also, the time frequency domain analysis of RR variability has disadvantage to get the details of irregular RR interval rhythm. In this study, we describe an atrial fibrillation detection algorithm through non-linear analysis of irregular RR interval rhythm based on the variability, randomness and complexity. We employ a new statistical techniques root mean squares of successive differences(RMSSD), turning points ratio(TPR) and sample entropy(SpEn). The detection algorithm was tested using the optimal threshold on two databases, namely the MIT-BIH Atrial Fibrillation Database and the Arrhythmia Database. We have achieved a high sensitivity(Se:94.5%), specificity(Sp:96.2%) and Se(89.8%), Sp(89.62%) respectively.

Magnetocardiogram Measurement of Laboratory Rat (백서를 이용한 심자도 신호 측정)

  • Kim, I.S.;Ahn, San;Kwon, H.C.;Song, J.H.
    • Progress in Superconductivity
    • /
    • v.11 no.2
    • /
    • pp.147-151
    • /
    • 2010
  • We have developed a high-$T_c$ SQUID magnetocardiogram (MCG) system for small laboratory animals. White noise of the measurement system was about 30 fT/$Hz^{1/2}$ when measured in a magnetically shielded room. We optimized the measurement position to obtain clear MCG wave from rat's small heart by using grid measurements. With the optimization, the MCG signal was successfully detected with the peak amplitude of about 30 pT. We could observe well defined P-, QRS-, and T-waves from the rat MCG. The results suggest that the developed system has a strong potential to monitor the progress of the heart disease model by using a laboratory rat.

A Design of UHF Sensor using Partial Discharge Measurement in GIS (부분방전 측정용 UHF센서의 설계)

  • Park, K.S.;Kim, J.B.;Song, Y.P.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.28-30
    • /
    • 2002
  • The PD in GIS leads to a charge transfer and a voltage drop across the discharge area. They cannot be measure directly but we can measure electromagnetic wave made by PD. In generally, compared with VHF band, electromagnetic waves of UHF band have a low noise therefore, we can detect the real defect with several pC in GIS using UHF method. In this paper, the U-slot microstrip patch antenna for measuring PD signal in GIS is presented. the proposed UHF sensor are designed to have large band characteristics and unaffected structure for GIS operation.

  • PDF

Estimation of Significant Wave Heights from X-Band Radar Using Artificial Neural Network (인공신경망을 이용한 X-Band 레이다 유의파고 추정)

  • Park, Jaeseong;Ahn, Kyungmo;Oh, Chanyeong;Chang, Yeon S.
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.6
    • /
    • pp.561-568
    • /
    • 2020
  • Wave measurements using X-band radar have many advantages compared to other wave gauges including wave-rider buoy, P-u-v gauge and Acoustic Doppler Current Profiler (ADCP), etc.. For example, radar system has no risk of loss/damage in bad weather conditions, low maintenance cost, and provides spatial distribution of waves from deep to shallow water. This paper presents new methods for estimating significant wave heights of X-band marine radar images using Artificial Neural Network (ANN). We compared the time series of estimated significant wave heights (Hs) using various estimation methods, such as signal-to-noise ratio (${\sqrt{SNR}}$), both and ${\sqrt{SNR}}$ the peak period (TP), and ANN with 3 parameters (${\sqrt{SNR}}$, TP, and Rval > k). The estimated significant wave heights of the X-band images were compared with wave measurement using ADCP(AWC: Acoustic Wave and Current Profiler) at Hujeong Beach, Uljin, Korea. Estimation of Hs using ANN with 3 parameters (${\sqrt{SNR}}$, TP, and Rval > k) yields best result.

A High Power 60 GHz Push-Push Oscillator Using Metamorphic HEMT Technology (Metamorphic HEMT를 이 용한 60 GHz 대역 고출력 Push-Push 발진기)

  • Lee Jong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.7 s.110
    • /
    • pp.659-664
    • /
    • 2006
  • This paper reports a high power 60 GHz push-push oscillator fabricated using $0.12{\mu}m$ metamorphic high electron-mobility transistors(mHEMTs). The devices with a $0.12{\mu}m$ gate-length exhibited good DC and RF characteristics such as a maximum drain current of 700 mA/mm, a peak gm of 660 mS/mm, an $f_T$ of 170 GHz, and an $f_{MAX}$ of more than 300 GHz. By combining two sub-oscillators having $6{\times}50{\mu}m$ periphery mHEMT, the push-push oscillator achieved a 6.3 dBm of output power at 59.5 GHz with more than - 35 dBc fundamental suppression. The phase noise of - 81.5 dBc/Hz at 1 MHz offset was measured. This is one of the highest output power obtained using mHEMT technology without buffer amplifier, and demonstrates the potential of mHEMT technology for cost effective millimeter-wave commercial applications.

Design of Temperature Compensation Circuit for W-band Radar Receiver (W-band 레이더 수신기용 온도보상회로 설계)

  • Lee, Dongju;Kim, Wansik;Kwon, Jun-Beom;Seo, Mihui;Kim, Sosu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.4
    • /
    • pp.129-133
    • /
    • 2020
  • In this paper, a temperature compensation circuit is presented in order to mitigate gain variability due to temperature in the W-band low-noise amplifier (LNA). The proposed cascode temperature compensation bias circuit automatically controls gate bias voltages of the common-source LNA in order to suppress variations of small-signal gain. The designed circuit was realized in a 100-nm GaAs pHEMT process. The simulated voltage gain of W-band LNA including the proposed bias circuit is >20 dB with gain variability less than ±0.8 dB in the range of temperatures between -35 to 71℃. We expect that the proposed circuit contributes to millimeter-wave receivers for stable performances in radar applications.

Estimation of the Depth of Embedded Sheet Piles Using Two Types of Geophysical Loggings (다종 물리검층을 통한 시트파일 근입 심도 추정 연구)

  • Hwang, Sungpil;Kim, Wooseok;Jeoung, Jaehyeung;Kim, Kiju;Park, Byungsuk;Lee, Chulhee
    • The Journal of Engineering Geology
    • /
    • v.32 no.4
    • /
    • pp.525-534
    • /
    • 2022
  • This investigation used two different geophysical logging techniques to confirm the depth to which a sheet pile was driven. Depth was estimated through analysis of the movement speed and three-component movement directions of a P-wave transmitted through the ground. It was also estimated by pole-pole and pole-dipole methods using electrical data logging to measure apparent resistivity. The two methods' respective results were 9.0 m (±1.5 m) and 7.5 m. As field ground conditions will include mixtures of various materials, electrical data logging is judged to be suitable for assessing depth due to its low signal-to-noise ratio.

A Study on Design and Implementation of Low Noise Amplifier for Satellite Digital Audio Broadcasting Receiver (위성 DAB 수신을 위한 저잡음 증폭기의 설계 및 구현에 관한 연구)

  • Jeon, Joong-Sung;You, Jae-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.28 no.3
    • /
    • pp.213-219
    • /
    • 2004
  • In this paper, a LNA(Low Noise Amplifier) has been developed, which is operating at L-band i.e., 1452∼1492 MHz for satellite DAB(Digital Audio Brcadcasting) receiver. The LNA is designed to improve input and output reflection coefficient and VSWR(Voltage Standing Wave Ratio) by balanced amplifier. The LNA consists of low noise amplification stage and gain amplification stage, which make a using of GaAs FET ATF-10136 and VNA-25 respectively, and is fabricated by hybrid method. To supply most suitable voltage and current, active bias circuit is designed Active biasing offers the advantage that variations in $V_P$ and $I_{DSS}$ will not necessitate a change in either the source or drain resistor value for a given bias condition. The active bias network automatically sets $V_{gs}$ for the desired drain voltage and drain current. The LNA is fabricated on FR-4 substrate with RF circuit and bias circuit, and integrated in aluminum housing. As a reults, the characteristics of the LNA implemented more than 32 dB in gain. 0.2 dB in gain flatness. lower than 0.95 dB in noise figure, 1.28 and 1.43 each input and output VSWR, and -13 dBm in $P_{1dB}$.

Polarization Precession Effects for Shear Elastic Waves in Rotated Solids

  • Sarapuloff, Sergii A.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.842-848
    • /
    • 2013
  • Developments of Solid-State Gyroscopy during last decades are impressive and were based on thin-walled shell resonators like HRG or CRG made from fused quartz or leuko-sapphire. However, a number of design choices for inertial-grade gyroscopes, which can be used for high-g applications and for mass- or middle-scale production, is still very limited. So, considerations of fundamental physical effects in solids that can be used for development of a miniature, completely solid-state, and lower-cost sensor look urgent. There is a variety of different types of bulk acoustic (elastic) waves (BAW) in anisotropic solids. Shear waves with different variants of their polarization have to be studied especially carefully, because shear sounds in glasses and crystals are sensitive to a turn of the solid as a whole, and, so, they can be used for development of gyroscopic sensors. For an isotropic medium (for a glass or a fine polycrystalline body), classic Lame's theorem (so-called, a general solution of Elasticity Theory or Green-Lame's representation) has been modified for enough general case: an elastic medium rotated about an arbitrary set of axes. Travelling, standing, and mixed shear waves propagating in an infinite isotopic medium (or between a pair of parallel reflecting surfaces) have been considered too. An analogy with classic Foucault's pendulum has been underlined for the effect of a turn of a polarizational plane (i.e., an integration effect for an input angular rate) due to a medium's turn about the axis of the wave propagation. These cases demonstrate a whole-angle regime of gyroscopic operation. Single-crystals are anisotropic media, and, therefore, to reflect influence of the crystal's rotation, classic Christoffel-Green's tensors have been modified. Cases of acoustic axes corresponding to equal velocities for a pair of the pure-transverse (shear) waves have of an evident applied interest. For such a special direction in a crystal, different polarizations of waves are possible, and the gyroscopic effect of "polarizational precession" can be observed like for a glass. Naturally, formation of a wave pattern in a massive elastic body is much more complex due to reflections from its boundaries. Some of these complexities can be eliminated. However, a non-homogeneity has a fundamental nature for any amorphous medium due to its thermodynamically-unstable micro-structure, having fluctuations of the rapidly-frozen liquid. For single-crystalline structures, blockness (walls of dislocations) plays a similar role. Physical nature and kinematic particularities of several typical "drifts" in polarizational BAW gyros (P-BAW) have been considered briefly too. They include irregular precessions ("polarizational beats") due to: non-homogeneity of mass density and elastic moduli, dissymmetry of intrinsic losses, and an angular mismatch between propagation and acoustic axes.

  • PDF