• Title/Summary/Keyword: P-wave

검색결과 1,591건 처리시간 0.026초

Inner harbour wave agitation using boussinesq wave model

  • Panigrahi, Jitendra K.;Padhy, C.P.;Murty, A.S.N.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제7권1호
    • /
    • pp.70-86
    • /
    • 2015
  • Short crested waves play an important role for planning and design of harbours. In this context a numerical simulation is carried out to evaluate wave tranquility inside a real harbour located in east coast of India. The annual offshore wave climate proximity to harbour site is established using Wave Model (WAM) hindcast wave data. The deep water waves are transformed to harbour front using a Near Shore spectral Wave model (NSW). A directional analysis is carried out to determine the probable incident wave directions towards the harbour. Most critical threshold wave height and wave period is chosen for normal operating conditions using exceedence probability analysis. Irregular random waves from various directions are generated confirming to Pierson Moskowitz spectrum at 20m water depth. Wave incident into inner harbor through harbor entrance is performed using Boussinesq Wave model (BW). Wave disturbance experienced inside the harbour and at various berths are analysed. The paper discusses the progresses took place in short wave modeling and it demonstrates application of wave climate for the evaluation of harbor tranquility using various types of wave models.

앙안에서 정상 단안시와 약시안의 P-VEP 분석 (The Analysis of the P-VEP on the Normal Monocular Vision and Amblyopia in Binocular)

  • 김덕훈;김규수;성아영;박원학
    • 한국안광학회지
    • /
    • 제10권1호
    • /
    • pp.41-46
    • /
    • 2005
  • 본 연구의 목적은 양안에서 정상 단안시와 약시에서 P-VEP의 파형을 분석하였다. P-VEP는 3채널의 Nicolet system으로 기록하였다. 5명의 성인 피검자(남성 3인, 여성 2명: 평균 22세, 연령은 19세와 24 세 사이)를 기록하였다. 피검자는 전신건강, 약물복용, 유전, 알레르기 그리고 안질환을 포함하는 문진을 조사하였다. 시력과 입체시 검사는 각 피검자의 단안과 양안을 기록하였다. 피검자는 VEP 의 기록을 하는 동안 교정된 시력을 통해서 단안과 양안으로 P-VEP 자극을 본다. 연구의 결과 양안의 시력은 정상 단안 시력보다 좋은 것으로 나타났다. 입체시는 140초 이상을 가졌다. 한편 P-VEP 의 자극을 받은 단안 정상안은 양안으로 본 것과 비교해서 높은 진폭을 나타내었다. 그러나 약시의 파형은 정상 단안시와 양안시에 비해서 상당히 감소함을 가졌다. 결론적으로 본 연구에서는 시력검사에는 양안시가 정상 단안시에 비해서 좋은 시력을 나타내나, P-VEP 검사에서는 오히려 단안 정상 안이 양안에 비해서 높은 진폭을 나타내었다. 그러나 약시안은 시력과 P-VEP 모두 감소함을 나타내었다.

  • PDF

Advanced Channel Estimation Method for IEEE 802.11p/WAVE System

  • Jang, DongSeon;Ko, Kyunbyoung
    • International Journal of Contents
    • /
    • 제15권4호
    • /
    • pp.27-35
    • /
    • 2019
  • In this paper, we propose an advanced Minimum Mean Square Error (MMSE) channel estimation method for IEEE 802.11p/Wireless Access in Vehicular Environments (WAVE) systems. To improve the performance of MMSE method, we apply the Weighted Sum using Update Matrix (WSUM) scheme to the step of calculating the instantaneously estimated channel and then, a time domain selectively averaging method is applied after the WSUM scheme. Based on that, the accuracy of instantaneously estimated channel increases and then, the accuracy of auto covariance matrix also increases. Consequently, we can achieve the performance gain over the conventional MMSE method. Through simulations based on the IEEE 802.11p standard, it is confirmed that the proposed scheme can outperform the existing channel estimation schemes.

Wave height from satellite altimetry and its comparison with ECMWF product

  • Kim, Seung-Bum;Cotton, P.David
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.337-340
    • /
    • 2002
  • Monitoring of wave height is important primarily to reduce storm risks at sea and along the coast. Wave heights in recent years have increased 50% for the last 40 years, thus requiring intensive monitoring. Satellite altimetry offers a powerful tool for regular and extensive monitoring of the wave height. We extracted significant wave height (SWH) using several altimeter missions from 1987-1995 over the Northwest Pacific and compared with ECMWF reanalysis (ERA) products. For large wave heights > 2.5 m, the ERA wave heights are smaller than the altimetric ones, while for small wave heights the ERA wave heights are larger. Comparison in SWH between altimetric derivations and ERA model products shows the discrepancy of 0.46-0.21$\times$SWH(m).

  • PDF

진원지 인근 지진 조기 경보를 위한 선착 P파 다중 탐지 시스템 개발 (Development of Earthquake Early Warning System nearby Epicenter based on P-wave Multiple Detection)

  • 이태희;노진석;홍승서;김영석
    • 한국지반신소재학회논문집
    • /
    • 제18권4호
    • /
    • pp.107-114
    • /
    • 2019
  • 본 논문에서는 진원지 주변에서 빠르고 정확한 지진 조기 경보를 수행하기 위한 선착 P파 다중 탐지 시스템과 이를 구동하기 위한 지진파 초동 탐지 및 경보 알고리즘을 개발하였다. 공용 중인 5개소(포항지역 4개소)의 건축물을 선정하여 개발한 계측 시스템을 설치하였고, 지반 진동을 실시간 모니터링하며 실증시험을 진행하였다. 실증 모니터링 중 2019년 9월 26일 포항 지역에서 규모 2.3의 지진이 발생하였다. 포항지역에 설치된 총 4개소의 시스템 중 3개소에서 P파 초동 탐지 알고리즘이 작동되어 지진동 이벤트로 기록되었다. 진원지로부터 5.5 km로 가장 가까운 계측소는 지진 발생 후 1.2초 후 P파 초동이 감지되었으며, P파 도달 후 약 1.02초 후 S파가 도달하여 다소의 경보시간을 제공해주었다. P파가 탐지된 3곳의 최대 가속도는 각각 6.28gal, 6.1gal, 5.3gal로 기록되었으며, 이벤트 경보 발령을 위한 최대 지반 가속도의 임계값(25.1gal)을 초과하지 않아 경보 알고리즘이 작동하지 않았다. 향후 지속적인 모니터링 및 분석을 통해 추가 검증이 이루어진다면 국내 실정에 맞는 실효성 높은 지진 경보 시스템으로 활용 될 수 있을 것으로 판단된다.

심전도 자동 진단 알고리즘 및 장치 구현(III) - 심방 및 심실활동 검출기 (An implementation of automated ECG interpretation algorithm and system(III) - Detector of atrium and ventricle activity)

  • 권혁제;이정환;윤지영;최성균;이준영;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.288-292
    • /
    • 1996
  • This paper describes far the detection of heart event that is, QRS complex and P wave which are result from heart activity. The proposed QRS detection method by using the spatial velocity was identified as having the 99.6% detection accuracy as well as fast processing time. Atrial flutter, coupled P wave, and noncoupled P wave as well as atrial fibrillation could be detected correctly by three different algorithms according to their origination farm. About 99.6% correction accuracy coupled P wave could be obtained and we could be found that most detection errors are caused by establishing wrong search interval.

  • PDF

Pressure pain threshold and visual analogue scale changes in the high and low energy extracorporeal shock wave

  • Yang, You-Jin;Lee, Seung-Joon;Choi, Matthew
    • Physical Therapy Rehabilitation Science
    • /
    • 제3권2호
    • /
    • pp.142-147
    • /
    • 2014
  • Objective: This study aims to investigate high energy and low energy extracorporeal shockwave therapy (ESWT) and which one is more effective for shoulder pain. Design: Single blind randomized controlled trial. Methods: Fifty two subjects with upper trapezius (UT) trigger point (TrP) participated in this study. They were allocated to high energy (n=26) and low energy group (n=26). This study applies ESWT and investigates the changes of pressure pain threshold (PPT) and visual analogue scale (VAS). The high and low energy groups received focused piezo electric type ESWT 4 Hz, 1,000 pulses and 0.351 and $0.092mJ/mm^2$ respectively. Outcome measures of PPT and pain was measured by algometer and pain VAS. These measurements were performed before and after treatment. Results: The PPT value was significantly increased in both groups after treatment (p<0.05) and VAS scores were significantly decreased after treatment in both groups (p<0.05). However, there were no significant differences between groups. Conclusions: ESWT is an effective treatment for the application of the UT TrP. Although there were significant effects of extracorporeal shock wave therapy on PPT and VAS scores, there were no signficant differences between high and low energy extracorporeal shock wave therapy.

Median and ulnar F-wave inversion as a supplementary criterion for diagnosis of carpal tunnel syndrome

  • Kim, Yoohwan;Jang, Jae-Hong;Cho, Charles S.;Kim, Byung-Jo
    • Annals of Clinical Neurophysiology
    • /
    • 제19권1호
    • /
    • pp.13-19
    • /
    • 2017
  • Background: Median F-wave latencies are physiologically shorter than ulnar latencies, but they are often longer relative to ulnar latencies in carpal tunnel syndrome (CTS). This study aimed to investigate the value of absolute F-waves and relative latency changes compared to ulnar latencies in the diagnosis of CTS. Methods: F-wave latencies of median and ulnar nerves in 339 hands from 339 patients with CTS and 60 hands from 60 control subjects were investigated. Mean F-wave minimal latencies of median and ulnar nerves were compared between groups. Patients were further divided into subgroups based on Canterbury grading and then analyzed using F-wave latency differences (FWLD) and F-wave ratio (FWR). Results: Of 339 hands in the CTS group, 236 hands exhibited F-wave inversion based on the FWLD criterion and 277 hands had F-wave inversion based on the FWR criterion. F-wave inversion had a sensitivity of 81.7% using the FWR criterion to diagnose CTS. The mean FWLD and FWR were significantly greater in all patient subgroups compared to the control group (p < 0.001). In addition, mean FWLD and FWR showed significant correlations (r = -0.683 and r = 0.674, respectively, p < 0.001) with disease severity. Conclusions: F-wave studies are effective supplementary diagnostic tools comparing to other standard electrophysiologic criteria for screening patients with CTS.

너울성파랑 정의를 위한 파랑스펙트럼의 형상모수 특성 분석 (Analysis of the Wave Spectral Shape Parameters for the Definition of Swell Waves)

  • 안경모;천후섭;정원무;박등대;강태순;홍성진
    • 한국해안·해양공학회논문집
    • /
    • 제25권6호
    • /
    • pp.394-404
    • /
    • 2013
  • 본 연구에서는 너울성파랑을 정의하기 위한 첫 단계로 확률모의실험을 통해 파랑스펙트럼 첨두모수 $Q_p$, 주파수폭대역 모수 ${\varepsilon}$, 파랑스펙트럼 폭 모수 ${\nu}$의 특성들을 분석하였다. 이를 위해 유의파고 및 첨두주기의 결합확률 밀도함수를 새롭게 유도한 후, MCMC(Markov Chain Monte Carlo)기법을 이 함수에 적용하여 가상의 유의파고 및 첨두주기를 생성하였다. 그리고, 이 때 생성된 파랑자료들을 파랑스펙트럼모형에 적용하여 각각에 대한 파랑스펙트럼 형상모수들을 산정한 다음, 각각의 파랑자료들과 파랑스펙트럼 형상모수들의 상관관계 계수를 산정하는 방법으로 각 파랑스펙트럼 형상모수의 특성들을 조사하였다. 본 연구의 결과에 의하면, 파랑스펙트럼 형상모수 중 파랑스펙트럼 첨두모수가 유의파고 및 첨두주기에 관계없이 파랑스펙트럼의 뾰족한 정도를 잘 나타내고 있었는데, 이러한 특성은 후포 및 울릉도 파랑관측자료에서도 동일하게 나타나고 있는 것으로 확인되었다. 너울성파랑 정의를 위한 대표적인 파랑스펙트럼 형상모수로 파랑스펙트럼 첨두모수를 사용하는 것이 가장 적절한 것으로 보인다.

낮은 변환손실 특성의 94 GHz MHEMT MIMIC Resistive 믹서 (Low Conversion Loss 94 GHz MHEMT MIMIC Resistive Mixer)

  • 안단;이복형;임병옥;이문교;오정훈;백용현;김성찬;박정동;신동훈;박형무;박현창;김삼동;이진구
    • 대한전자공학회논문지TC
    • /
    • 제42권5호
    • /
    • pp.61-68
    • /
    • 2005
  • 본 논문에서는 낮은 변환손실 특성의 94 GHz MIMIC(Millimeter-wave Monolithic Integrated Circuit) resistive 믹서를 설계 및 제작하였다. MIMIC resistive 믹서는 $0.1{\mu}m$ InGaAs/InAlAs/GaAs Metamorphic HEMT (High Electron Mobility Transistor)를 이용하여 설계 및 제작되었다. 제작된 MHEMT는 드레인 전류 밀도 665 mA/mm, 최대 전달컨덕턴스(Gm)는 691 mS/mm를 얻었으며, RF 특성으로 fT는 189 GHz, fmax는 334 GHz의 양호한 성능을 나타내었다. 94 GHz MIMIC 믹서의 개발을 위해 MHEMT의 비선형 모델과 CPW 라이브러리를 구축하였으며, 이를 이용하여 MIMIC 믹서를 설계하였다. 설계된 믹서는 본 연구에서 개발된 MHEMT MIMIC 공정을 이용해 제작되었다. 94 GHz MIMIC resistive 믹서의 측정결과 변환손실 특성은 94 GHz에서 8.2 dB의 양호한 특성을 나타내었으며, 입력 P1 dB는 9 dBm, 출력 P1 dB는 0 dBm의 결과를 얻었다. Resistive 믹서의 LO-IF 격리도는 94.03 GHz에서 15.6 dB의 측정 결과를 얻었다. 본 논문에서 설계 및 제작된 94 GHz MIMIC resistive 믹서는 기존의 W-band 대역 resistive 믹서와 비교하여 낮은 변환손실 특성을 나타내었다.