• Title/Summary/Keyword: P-wave

Search Result 1,576, Processing Time 0.025 seconds

The influence of initial stress on wave propagation and dynamic elastic coefficients

  • Li, Xibing;Tao, Ming
    • Geomechanics and Engineering
    • /
    • v.8 no.3
    • /
    • pp.377-390
    • /
    • 2015
  • The governing equations of wave propagation in one dimension of elastic continuum materials are investigated by taking the influence of the initial stress into account. After a short review of the theory of elastic wave propagation in a rock mass with an initial stress, results indicate that the initial stress differentially influences P-wave and S-wave propagation. For example, when the initial stress is homogeneous, for the P-wave, the initial stress only affects the magnitude of the elastic coefficients, but for the S-wave, the initial stress not only influences the elastic coefficients but also changes the governing equation of wave propagation. In addition, the P-wave and S-wave velocities were measured for granite samples at a low initial stress state; the results indicate that the seismic velocities increase with the initial stress. The analysis of the previous data of seismic velocities and elastic coefficients in rocks under ultra-high hydrostatic initial stress are also investigated.

A P-wave Detection Algorithm by Template Matching Method (템플레이트 매칭에 의한 심전도 신호의 P파 검출 알고리즘에 관한 연구)

  • Hong, Jae-Woo;Jeong, Hee-Kyo;Shin, Kun-Soo;Lee, Myoung-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.05
    • /
    • pp.21-24
    • /
    • 1990
  • This paper presents a new algorithm for P-wave detection in the ECG signal, we get the peak, onset and offset point by using significant point extraction algorithm with 5-point derivative. To these set of extracted significant points, we apply amplitude and duration threshold criterion. we define the set of significant point meeting the criterion as P-wave candidate. Then P-wave candidate is classified through match-process with template. The template with maximum number or P-wave candidate is selected to be the P-wave.

  • PDF

Comparison of Characteristics of P-Wave Detection in ECG with Wireless Patch Electrodes

  • Cho, Young Chang;Kim, Min Soo;Yoon, Jeong Oh
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.1
    • /
    • pp.43-52
    • /
    • 2014
  • P-wave characteristic in the human electrocardiogram (ECG) is important in the diagnosis of atrial conduction pathology. In this paper, we measured an ECG signal from patient with cardiovascular disease using one lead ECG electrode system which is based on the wireless cardiac monitoring system. And we detected a P-wave in ECG signal using the complex-valued continuous wavelet transforms (CWT) according to two kinds of patch type electrodes such as an existing narrow patch type electrode and the improved wide patch type electrode presented in this paper. Also, we compared the characteristics in detecting the P-wave in terms of the magnitude and the width of P-waves. From the results of comparison we found that the width and the magnitude of P-wave detected using the wide patch type electrode is improved to be interpreted easier compared to those using the narrow patch type electrode. Furthermore, we have also proven that the complex-valued CWT can be used as a robust detector for P-wave in ECG signal analysis.

Prognostic Value of Inferior Shift of P wave Axis after Catheter Ablation for Longstanding Persistent Atrial Fibrillation based on Dallas Lesion Set Including Anterior Line

  • Shin, Dong Geum;Kim, Tae-Hoon;Jeong, Hyunmin;Kim, Alexander;Uhm, Jae-Sun;Joung, Boyoung;Lee, Moon-Hyoung;Hwang, Chun;Pak, Hui-Nam
    • International Journal of Arrhythmia
    • /
    • 제18권2호
    • /
    • pp.66-76
    • /
    • 2017
  • Background and Objectives: Although an anterior linear ablation is an effective lesion set in radiofrequency catheter ablation (RFCA) for longstanding persistent atrial fibrillation (L-PeAF), its durability for bidirectional block (BDB) is only about 60% at repeat procedure. We hypothesized that changes in electrocardiogram (ECG) may predict an anterior line block state and the clinical outcome of L-PeAF ablation. Subjects and Methods: We studied 304 L-PeAF patients (77% male, $60{\pm}10yrs$), who consistently underwent RFCA Dallas lesion set (circumferential pulmonary vein isolation, posterior box lesion, and anterior line) protocol with subsequent comparison of pre-procedural and post-procedural P wave axes, and one year follow-up (n=205) sinus rhythm (SR) ECGs. Results: 1. P wave axis shifted inferiorly at immediate post-procedure (p<0.001), and was independently correlated with BDB of anterior line (${\ss}=10.4$, 95% confidence interval [CI] 2.79-17.94, p=0.008). 2. The degree of post-procedural inferior shift of P wave axis did not reflect clinical recurrence within one-year (n=205, p=0.923), potentially due to conduction recovery of an anterior line. However, among 160 patients without clinical recurrence within one-year, P wave axis at one-year ECG was independently associated with very late recurrence of AF after one-year (n=160, hazard ratio [HR] 0.98; 95% CI 0.97-0.99, p=0.001), during $45.6{\pm}16.7$ months of follow-up. 3. Among 22 patients who underwent repeat procedures, P wave axis shift was more significant in patients with maintained BDB of an anterior line than in those without (p=0.015). Conclusion: An inferior shift of P wave axis reflects the achievement and the maintenance of an anterior line BDB, and is associated with better long-term clinical outcome after catheter ablation for L-PeAF based on Dallas lesion set.

RF Circuit Design for IEEE 802.11p Implementation (IEEE 802.11p 구현을 위한 RF 회로 설계)

  • Lee, Se-Yeun;Lee, Myung-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.1
    • /
    • pp.54-61
    • /
    • 2012
  • The WAVE specification, which for the Next-Generation ITS environment is a common title: IEEE 802.11p and IEEE P1609 specifications. These days, there are many activities for researching WAVE specification by release of the IEEE 802.11p specification. The difference between high-speed vehicle environment and the indoor environment, the wireless communication channel mode is that much more severe. Thus, the wireless communication system design, temperature, noise, multipath fading and can degrade the performance of the system points should be fully considered matters of. In this paper, we showed WAVE wireless communication system which based on IEEE 802.11p PHY/MAC design process, and also showed solving process many implementation problems.

A study on P wave detection method in ECG (심전도에서 P파의 검출방법에 관한 연구)

  • Ju, Jang-kyu;Lee, Ki-Young;Bae, Cheol-Soo;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.1
    • /
    • pp.17-22
    • /
    • 2011
  • In this study, a P wave emphasizing and detection algorithm from ECG signal was proposed to read arrhythmia. The algorithm uses two slope tracing waveform, the descending slope tracing wave and the ascending slope tracing wave, developed for efficient determination of slope inverting points and sudden slope changing points. The algorithm generates the slope tracing waveform which trace the original ECG wave, and subtracts one tracing wave from the other to detect P and T waves. The algorithm has been applied to MIT/BIH database in order to verify its efficacy and validity in practical applications.

P-wave Detection Algorithm by Significant Point Extraction Method (특성점 추출에 의한 P파 검출 알고리즘에 관한 연구)

  • Hwang, Sun-Chul;Jeong, Hee-Kyo;Lee, Myoung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.162-165
    • /
    • 1989
  • This paper describes an algorithm of P-wave detection by significant point extraction method with digital differentiation. P-waves are detected by pattern matching algorithm with significant points. By means of defecting onset and offset points of P-waves, this algorithm can measure the PR intervals exactly which is important to diagnosis the atrial arrhythmia. Because P-wave duration is changed according to heart-rates, we calculate the R-R interval prior to the determination of P-wave duration threshold values in order to actively adapt to the change of P duration The results obtained from the proposed algorithm have defected successfully P-wave almost more than 90%.

  • PDF

Analysis of Offshore Wind Tower against Impulsive Breaking Wave Force by P-Y Curve

  • Kim, Nam-Hyeong;Koh, Myung-Jin
    • Journal of Navigation and Port Research
    • /
    • v.39 no.5
    • /
    • pp.385-391
    • /
    • 2015
  • In offshore, various external forces such as wind force, tidal current and impulsive breaking wave force act on offshore wind tower. Among these forces, impulsive breaking wave force is especially more powerful than other forces. Therefore, various studies on impulsive breaking wave forces have been carried out, but the soil reaction are incomplete. In this study, the p-y curve is used to calculate the soil reaction acting on the offshore wind tower when an impulsive breaking wave force occurs by typhoon. The calculation of offshore wind tower against impulsive breaking wave force is applied for the multi-layered soil. The results obtained in this study show that although the same wave height is applied, the soil reaction generated by impulsive breaking wave force is greater than the soil reaction generated by wave force.

A Study on S-wave Reflection method for the assessment of physical property of dam body (댐체 물성 평가를 위한 S파 반사법에 관한 연구)

  • Kim, Hyoung-Soo;Kim, Jung-Yul;Ha, Ik-Soo;Kim, Yoo-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.392-399
    • /
    • 2005
  • Shear modulus (or rigidity) of dam material is an important parameter which can be directly associated with the deformation of dam. Seepage or leakage of water can cause the defects or cracks of dam body. The existence of cracks and rigidity of dam body are decisive information for the estimation of dam safety. Rigidity of material is mainly determined from S-wave velocity and the defects of dam body can be detected by seismic reflection survey. Therefore, seismic reflection survey will be a desirable method which can give a solution about dam safety problem. Among various physical properties of dam body, S-wave velocity is the most important information but it is not easy to get the information. In this study, diverse measuring techniques of S-wave reflection survey were attempted to get the information about S-wave velocity of dam body. Ultimately, S-wave velocity could be estimated by the analysis of SH reflection events which can be easily observed in shot gather data obtained from SH measuring technique. Meanwhile, P-wave reflection survey was also performed at the same profile. P-beam radiation technique which can reduce the surface waves and reinforce the P-wave reflection events was applied for giving a help to analyse P-wave velocity. In the end, P-and S-wave velocity, Vs/Vp, Poisson's ratio distribution of the vertical section under the profile could be acquired.

  • PDF

A Study for measurement method of P-wave duration in Paroxysmal Atrial Fibrillation(PAF) subjects (발작성 심방세동 환자의 P파 간격 측정 방법에 관한 연구)

  • Lee, J.Y.;Yeo, H.S.;Han, W.T.;Kim, I.Y.;Lee, B.C.;Kim, J.S.;Mi, J.S.;Seo, J.D.;Lee, W.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.181-182
    • /
    • 1998
  • In previous study for correlation between P-wave Signal Averaged Electrocardiography (SAECG) and Paroxysmal Atrial Fibrillation (PAF) subjects, we showed that the duration of P-wave in subjects is longer than in controls. In this respect, the P-wave SAECG is a new method proving to be an accurate and independent noninvasive marker for the risk of PAF. To prove this suggestion, accurate detection and alignment of P-wave are indispensible. In previous study, we measured P-wave duration by manual. So it was not accurate and consistent. To measure the P-wave duration accurately and automatically, we have developed an automatic algorithm for P-wave duration measurement. We showed that the duration of P- wave in the subjects is longer than in controls with this algorithm.

  • PDF