• Title/Summary/Keyword: P-V value

Search Result 1,083, Processing Time 0.029 seconds

EFFECT OF SURFACE PENETRATING SEALANT ON THE MICROLEAKAGE OF CERVICAL RESTORATIONS (Surface penetrating sealant가 치경부 수복물의 미세누출에 미치는 영향)

  • 김성원;조용범;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.64-76
    • /
    • 2001
  • Despite the improvements in bond strengths of dentin adhesives and resin-modified glass ionomers, the marginal seal of cervical restorations remains a concern. Microleakage at poorly sealed margins can result in staining, post-operative sensitivity, pulpal irritation, and recurrent caries. The objective of this study was to evaluate the effect of surface penetrating sealant(SPS) on the microleakage of cervical restorations. 45 extracted human teeth were selected, and Class V preparations were prepared on the both buccal and lingual surface of the teeth to the following dimensions : 1.5mm axially, 3mm mesiodistally, and 3mm incisogingivally. After cervical restoration with composite resin, compomer, glass ionomer each restoration was treated as three methods: No Tx., Scotchbond Multipurpose Adhesive$^{\circledR}$, Fortify$^{\circledR}$. The sections were examined with a stereomicroscope to determine the extent of microleakage at enamel and dentin margins. The results of this study were as follows. 1. All groups showed some microleakage. 2. Gingival cavity wall with cementum margin showed significantly higher leakage value than occlusal cavity wall with enamel margin. 3. The group treated with SPS showed significantly lower leakage value than no treated group(p<0.05). But there is no difference between Fortify$^{\circledR}$ and Scotchbond Multipurpose adhesive$^{\circledR}$. The results of this study suggest that SPS are effective in reducing microleakage of class V restorations. But it is certain that some microleakage still occurred despite the application of SPS.

  • PDF

Evaluation of Mixtures of Certain Market Wastes as Silage

  • Ozkul, H.;Kilic, A.;Polat, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.9
    • /
    • pp.1243-1248
    • /
    • 2011
  • The aim of this study was to determine the usefulness of vegetable wastes as silage for ruminants. Varying amounts of wheat straw (WS), wheat bran (WB) and salt (S) were combined with minced vegetable wastes (VW) during ensilage. Seven different ingredient combinations were investigated viz: 100% VW (Group I, control), 90% VW+9% WS+1% S (Group II), 80% VW+15% WS+4% WB+1% S (Group III), 70% VW+20% WS+9% WB+1% S (Group IV), 90% VW+9% WB+1% S (Group V), 80% VW+15% WB+4% WS+1% S (Group VI) and 70% VW+20% WB+9% WS+1% S (Group VII). The inclusion of straw and bran increased (p<0.01) the DM content of silage. The highest contents of the pure silage were CP (p<0.001), EE (p<0.01) and NFE (p<0.05). NDF contents of VW silage and group V were significantly lower and especially the VW silage was found to have the lowest ADL content (p<0.01). The in vitro ME values of VW silage and bran added silage were higher than other groups (p<0.01). pH, lactic acid and acetic acid values of silage groups were changed between 4.09-4.20, 2.43-3.46% and 0.60-0.86%, respectively. In conclusion, different mixtures of VW have a high ensilage capacity and can serve as an alternative roughage source for ruminants. The addition of 9% bran significantly improved the silage in view of both dry matter content and nutritive value.

Formation of p$^{+}$-n ultra shallow junction with Co/Ti bilayer silicide contact (Co/Ti 이중막 실리사이드 접촉을 갖는 p$^{+}$-n 극저접합의 형성)

  • 장지근;엄우용;신철상;장호정
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.5
    • /
    • pp.87-92
    • /
    • 1998
  • Ultr shallow p$^{+}$-n junction with Co/Ti bilayer silicidde contact was formed by ion implantation of BF$_{2}$ [energy : (30, 50)keV, dose:($5{\times}10^{14}$, $5{\times}10^{15}$/$\textrm{cm}^2$] onto the n-well Si(100) region and by RTA-silicidation and post annealing of the evaporated Co(120.angs., 170.angs.)/Ti(40~50.angs.) double layer. The sheet resistance of the silicided p$^{+}$ region of the p$^{+}$-n junction formed by BF2 implantation with energy of 30keV and dose of $5{\times}10^{15}$/$\textrm{cm}^2$ and Co/Ti thickness of $120{\AA}$/(40~$50{\AA}$) was about $8{\Omega}$/${\box}$. The junction depth including silicide thickness of about $500{\AA}$ was 0.14${\mu}$. The fabricated p$^{+}$ -n ultra shallow junction depth including silicide thickness of about $500{\AA}$ was 0.14${\mu}$. The fabricated p$^{+}$-n ultra shallow junction with Co/Ti bilayer silicide contact did not show any agglomeration or variation of sheet resistance value after post annealing at $850^{\circ}C$ for 30 minutes. The boron concentration at the epitaxial CoSi$_{2}$/Si interface of the fabricated junction was about 6*10$6{\times}10^{19}$ / $\textrm{cm}^2$./TEX>.

  • PDF

Low-Temperature Chemical Sintered TiO2 Photoanodes Based on a Binary Liquid Mixture for Flexible Dye-Sensitized Solar Cells

  • Md. Mahbubur, Rahman;Hyeong Cheol, Kang;Kicheon, Yoo;Jae-Joon, Lee
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.453-461
    • /
    • 2022
  • A chemically sintered and binder-free paste of TiO2 nanoparticles (NPs) was prepared using a binary-liquid mixture of 1-octanol and CCl4. The 1:1 (v/v) complex of CCl4 and 1-octanol easily interacted chemically with the TiO2 NPs and induced the formation of a highly viscous paste. The as-prepared binary-liquid paste (PBL)-based TiO2 film exhibited the complete removal of the binary-liquid and residuals with the subsequent low-temperature sintering (~150℃) and UV-O3 treatment. This facilitated the fabrication of TiO2 photoanodes for flexible dye-sensitized solar cells (f-DSSCs). For comparison purposes, pure 1-octanol-based TiO2 paste (PO) with moderate viscosity was prepared. The PBL-based TiO2 film exhibited strong adhesion and high mechanical stability with the conducting oxide coated glass and plastic substrates compared to the PO-based film. The corresponding low-temperature sintered PBL-based f-DSSC showed a power conversion efficiency (PCE) of 3.5%, while it was 2.0% for PO-based f-DSSC. The PBL-based low- and high-temperature (500℃) sintered glass-based rigid DSSCs exhibited the PCE of 6.0 and 6.3%, respectively, while this value was 7.1% for a 500℃ sintered rigid DSSC based on a commercial (or conventional) paste.

Standardization of an enzyme-linked immunosorbent assay for detection of antibody to avian reticuloendotheliosis virus (세망내피증 바이러스 항체검출을 위한 ELISA 표준화)

  • Sung, Haan Woo;Lee, Su Jeong
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.4
    • /
    • pp.569-574
    • /
    • 2005
  • Enzyme-linked immunosorbent assay (ELISA) for detection of antibodies to reticuloendotheliosis virus (REV) at single serum dilution was standardized. REV HI, one of the Korean field isolates, was inoculated into chicken embryo fibroblast (CEF) cells and was harvested from the culture fluids and cells after 10 to 12 days. Viruses were purified by centrifugation at the $107,000{\times}g$ for 12 hours on 20, 30, 45% (W/V) sucrose gradient. Virus specific fraction was collected and used as ELISA antigen. To standardize ELISA, the optimal concentration of coating antigen ($1{\mu}g/well$) and conjugate (1/1000) was determined by corrected OD (OD value of positive serum-OD value of negative serum) and P/N ratio (OD value of positive serum/OD value of negative serum). To calculate ELISA titer by measuring absorbance at 1/400 single serum dilution, serum titrations were carried out for various sample sera together with standard positive and negative sera. The observed titers of serum samples were plotted against sample/positive (s/p) ratios at 1/400 serum dilution. From the above data, the ELISA titers could be calculated by the equation of $log_{10}$ ELISA titer = 2.2763 ($log_{10}$ s/p) + 3.482 (r = 0.93). For evaluating the sensitivity, the standardized method were compared with conventional agar gel immunodiffusion (AGID) test method using serum samples collected from REV infected field chicken flocks. Fifty seven of 60 samples (95%) were positive for REV by ELISA, whereas only 11 (18.3%) samples were positive by AGID test. This results suggested that the ELISA tests developed in this study could be used for detection of antibodies to REV with high sensitivity.

Studies on the Aging of Bovine Muscle at Adding Proteolytic Enzyme -Part V. Studies on the Tenderness Evaluation of Bovine Muscle Treated with Papain by Using Penetration Value- (단백질(蛋白質) 분해효소(分解酵素) 첨가시(添加時) 우육(牛肉)의 숙성(熟成)에 관(關)한 연구(硏究) -제5보 Papain처리(處理) 우육(牛肉)의 Penetration Value에 의한 유연성(柔軟性) 평가(評價)에 관(關)하여-)

  • Youn, Jung-Eae;Yang, Ryung
    • Korean Journal of Food Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.208-211
    • /
    • 1975
  • Round muscle of Korean cattle treated with papain were examined the tenderness relation by use of penetrometer which results were indicated as follows. 1. Measuring method of tenderness effect in bovine muscle was acknowledged that there are correlation by using penetrometer (p<.05) 2. Penetration value were also proportional increased according to increasing of enzyme concentration. 3. It was acknowledged as considerable difference in penetration value cf longitudinal and cross section against muscle fiber. 4. In the case of 0.05% enzyme addition, there are extremely high increasing rate of tenderness in longitudinal and cross section but it was not acknowledged as significant difference in 0.1% of enzyme concentration.

  • PDF

Performance Characteristics of p-i-n Type Organic Thin-film Photovoltaic Cell with CuPc: $F_4$-TCNQ Hole Transport Layer (CuPc: $F_4$-TCNQ 정공 수송층이 도입된 P-i-n형 유기 박막 태양전지의 성능 특성 연구)

  • Park, So-Hyun;Kang, Hak-Su;Senthilkumar, Natarajan;Park, Dae-Won;Choe, Young-Son
    • Polymer(Korea)
    • /
    • v.33 no.3
    • /
    • pp.191-197
    • /
    • 2009
  • We have investigated the effect of strong p-type organic semiconductor $F_4$-TCNQ-doped CuPc hole transport layer on the performance of p-i-n type bulk heterojunction photovoltaic device with ITO/PEDOT:PSS/CuPc: $F_4$-TCNQ(5 wt%)/CuPc:C60(blending ratio l:l)/C60/BCP/LiF/Al, architecture fabricated via vacuum deposition process, and have evaluated the J-V characteristics, short-circuit current ($J_{sc}$), open-circuit voltage($V_{oc}$), fill factor(FF), and power conversion efficiency(${\eta}_e$) of the device. By doping $F_4$-TCNQ into CuPc hole transport layer, increased absorption intensity in absorption spectra, uniform dispersion of organic molecules in the layer, surface uniformity of the layer, and enhanced injection currents improved the current photovoltaic device with power conversion efficiency(${\eta}_e$) of 0.16%, which is still low value compared to silicone solar cell indicating that many efforts should be made to improve organic photovoltaic devices.

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF

Fermentative Quality of Guineagrass Silage by Using Fermented Juice of the Epiphytic Lactic Acid Bacteria (FJLB) as a Silage Additive

  • Bureenok, S.;Namihira, T.;Tamaki, M.;Mizumachi, S.;Kawamoto, Y.;Nakada, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.6
    • /
    • pp.807-811
    • /
    • 2005
  • This experiment examined the characteristics of fermented juice of epiphytic lactic acid bacteria (FJLB) prepared by the addition of glucose, sucrose and molasses as a fermentation substrate. The effect of FJLB on the fermentative quality and changes in chemical composition during fermentation of guineagrass silage were also investigated. The pH value of the silages treated with FJLB rapidly decreased, and reached to the lowest value within 7 days of start of fermentation, as compared to the control. The number of lactic acid bacteria (LAB) in the treated silages increased for the first 3 days, thereafter the number of LAB declined gradually up to the end of the experiment. Silages treated with FJLB had larger populations of LAB than the control. Ammonia-nitrogen production increased throughout the ensiling period, which in the control and no-sugar added FJLB silages were higher than the other treated silages. Lactic acid levels varied with the time of ensiling and among the silage treatments. For any sugar FJLB treated silages, the lactic acid increased initially, and then slightly reduced to less than 50 g/kg of dry matter until 49 days after ensiling, except the silage treated with glucose added FJLB. Nevertheless, lactic acid content of the control decreased constantly from the beginning of ensiling and was not found after 35 days. Moreover, acetic acid content increased throughout the ensiling period. All the FJLB treated silages had significantly (p<0.05) lower pH and ammonia-nitrogen content, while significantly (p<0.05) higher lactic acid content and V-score value compared with the control. This study confirmed that the applying of FJLB with any sugar substrate improved fermentative quality of silage.

THE REPRODUCIBILITY OF VARIOUS PORCELAIN COLOR SELECTION SYSTEMS USING SPECTROPHOTOMETRY (수종 도재 색조 선택 시스템의 spectrophotometer를 이용한 색조 재현성 평가)

  • Kim Lee-Kyoung;Cho In-Ho;Shin Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.544-555
    • /
    • 2004
  • Statement of problem: Shade selection has traditionally been accomplished by visual examination, which is particularly relevant to the shade selection of anterior teeth, but the subjective nature of visual analysis can lead to errors in shade matching. Recently shade selection systems have been developed to provide a more objective and scientific approach to understanding and clarifying shade selection. Purpose : The purpose of this study was analysis of various shade analyzing equipment with the goal of providing a more objective shade selection. Materials and method: Visual shade matching system selection(Vita Lumin Vacuum shade guide, Vitapan 3D Master shade guide) and mechanical shade matching method($ShadeEye^{(R)}$-EX Chroma Meter, $Shadescan^{TM}$ System) used for this study. The shade guide tap specimens for 10 extracted maxillary anterior teeth were produced by selecting shades using each shade matching system. The accuracy of the selection of shades for the teeth and fabricated specimens were evaluated by analyzing the calculated shade difference(${\Delta}E^*$), using a spectrophotometer and calculating the output of value $L^*,\;a^*,\;b^*$. Results and conclusion: The results show that the average ${\{Delta}E^*$ value (difference of shade) of the shade tap specimens to the actual specimen decreased in the following order: Vita Lumin Vacuum Shade Guide(VL), $ShadeEye^{(R)}$-EX Chroma Meter(SE) Vitapan 3D Master Shade guide(V3), and $Shadescan^{TM}$ System(55) : and that there are significant statistical differences between the VL and SS (p<0.05). In the analysis of the ${\Delta}E^*$ (difference of shade) value,40% of the VL group was found to be less than 3.3 (limit value of shade tap specimens clinically acceptable), 60% in the V3 group, 50% in the SE group, and 80% in the SS group.