• 제목/요약/키워드: P-V value

Search Result 1,083, Processing Time 0.028 seconds

Electrical Characteristics Analysis of LED Lamps using Internal Converter for Road and Street Lighting (컨버터 내장형 LED 가로등 및 보안등의 전기적 특성 분석)

  • Kim, Hyang-Kon;Gil, Hyoung-Jun;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.238-244
    • /
    • 2010
  • In this paper, we studied electrical characteristics of internal converter type of LED lamps for road and street lighting. We surveyed electro-technical regulations and KS(Korean industrial standards) about LED luminairs. Waveforms of voltage and current, thermal distributions, insulation resistances between live parts and exposed conductive parts, and flame test of cover of LED lamps were experimented and analyzed. In regulations, insulation resistance between live conductors and exposed conductive parts should be greater than $0.2M{\Omega}$ in case nominal voltage of wiring is 220V. In KS codes, the value of insulation resistance should be greater than $2M{\Omega}$ while applying DC 500V or DC 100V. In the result of this study, waveforms of primary voltage and current were distorted. There was difference in waveforms of secondary voltage and current according to composition of converter. Mostly, insulation resistances were measured high more than regulation and code value but some measured points were measured badly($0.0M{\Omega}$). Cover of LED lamps was ignited easily. We expect that the results of this study would be helpful for revision of regulations and national codes for the electrical safety of LED road and street lighting.

A Study for the Reaction of ${\beta}$-Picoline with p-Substituted Benzoyl Chlorides by Pressure (압력변화에 따른 ${\beta}$-피콜린과 염화벤조일류의 반응에 대한 연구)

  • Yeong Cheul Kim;Se Kyong Kim
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.4
    • /
    • pp.517-522
    • /
    • 1992
  • The reaction of ${\beta}$-picoline with substituted benzoyl chlorides has been studied by means of conductometry under various pressures in acetonitrile. From the values of pseudo-first order and second order rate constants, the activation parameters (${\Delta}V{\neq}$, ${\Delta}{\beta}{\neq}$, ${\Delta}H{\neq}$, ${\Delta}S{\neq}$ and ${\Delta}G{\neq}$) and the pressure dependence of Hammett ${\rho}$ value were studied. The activation volume, the activation compressibility coefficient and the activation entropy were all negative. By increasing pressure the rate constant and Hammett ${\rho}$ value were increased, and the reaction mechanism was proceed in bond formation favored.

  • PDF

A Study on the Electrical Properties of Transformer Oils for Large Power (대용량 변압기유의 전기적특성에 관한 연구)

  • 이용우;김왕곤;홍진웅
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.3
    • /
    • pp.81-88
    • /
    • 1996
  • In order to investigate the electrical properties of transformer oils for large power, the characteristics of AC and Impulse breakdown in gap length of 1.0~2.5mm and that of volume resistivity were researched in temperature range of 20~$100^{\circ}C$. An geometrical capacitance of electrode with coaxial cylindrical shape for measuring the volume resistivity was 16pF, and highmegohm meter with model no. VMG-1000 was used, and also the applied voltage were DC 100, 250 and 500V. In the dependance of breakdown characteristics due to electrode gap length, it was confirmed that breakdown voltage was nearly uniform by volume effect according to the increase of gap. In the characteristics for AC breakdown, the dielectric strength was increased to $90^{\circ}C$ but decreased over $90^{\circ}C$, and also in case of impulse breakdown, it was increased to 7$0^{\circ}C$ and at dated $70^{\circ}C$ over in temperature range. The calculated mobility of oils in the characteristics for impulse breakdown were about $10^{-5}$~$10^{-4}cm^2/V{\cdot}S$, and the value of volume resistivity was almost invariable in low temperature range, regardless of voltage by the stable thermal properties, and it indicated a peak at $50^{\circ}C$ and had a sudden change to decrease over that temperature, and also the value of volume resistivity in 250V/mm at $80^{\circ}C$ is suitable for the International electrical standards, it was confirmed.

  • PDF

A Study on the Properties Analysis of an Iron Fittings Type CSST Damaged by the PCITS (PCITS에 의해 소손된 강이음쇠형 CSST의 특성 해석에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.121-127
    • /
    • 2016
  • This study analyzed the structural and electrical characteristics of an iron fittings type Corrugated Stainless Steel Tubing (CSST) damaged by the Primary Current Injection Test System (PCITS). CSST consists of cladding, tube, nuts, clamp ring, flare cap, socket, and ball valve. For an evaluation of the dielectric withstand voltage, the area between the live part and non-live part of the CCST shall withstand a voltage of 220 V AC for one minute. For an evaluation of the insulation performance by 500 V DC, it is required that the insulation exceed more than $1M{\Omega}$ before the temperature rise test, $0.3M{\Omega}$ after the test. Although the average resistance of the product was $11.5m{\Omega}$, that of the product damaged at a current of 130 A by the PCITS was $11.50m{\Omega}$. Furthermore, parts of the cladding were melted and black smoke appeared when a current of 130 A applied for 10 s. After 60 s, most parts were heated and turned red. At 120 s, the parts that turned red had widened. Although it did not form a normal distribution because the P value was 0.019 with a confidential interval of 95%, it revealed outstanding characteristics with an AD (Anderson-Darling) value of 0.896 and a standard deviation of 0.5573.

A Study on the Character and Walking Velocity of Crowd Going up Stairs (계단에서 올라가는 군집보행의 속도에 관한 조사 및 특성에 관한 연구)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.72-77
    • /
    • 2011
  • The effort of transferring some parts of urban functions to the underground space is growing trend among modem cities because of the limit of horizontal land use, the rise of land value, the diversification of human desire, etc. Thus, the basement of building and the subway station have deepened. It calls our attention to safety about evacuation from the underground space to the ground. Until now, the study about crowding walk in stairs has been progressed, focusing on the crowding walk that is going down the stairs, and there is no study about crowding walk that is going up the stairs. This study measured walking pace by crowd density that is going up the stairs in the subway station stairs making one-way movement of crowd. The actual survey showed that the mathematical relation 'V=0.638-0.0949p' determines going up walking velocity at a gradient of $23^{\circ}$, and the mathematical relation will be 'V=0.597-0.1067p' at a gradient of $30^{\circ}$, when it is converted, based on the average walking velocity of crowd by the slope of the stairs which is recommended by Architectural Institute of Japan.

A Study on the Electrical Characteristic Analysis of c-Si Solar Cell Diodes

  • Choi, Pyung-Ho;Kim, Hyo-Jung;Baek, Do-Hyun;Choi, Byoung-Deog
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.1
    • /
    • pp.59-65
    • /
    • 2012
  • A study on the electrical characteristic analysis of solar cell diodes under experimental conditions of varying temperature and frequency has been conducted. From the current-voltage (I-V) measurements, at the room temperature, we obtained the ideality factor (n) for Space Charge Region (SCR) and Quasi-Neutral Region (QNR) of 3.02 and 1.76, respectively. Characteristics showed that the value of n (at SCR) decreases with rising temperature and n (at QNR) increases with the same conditions. These are due to not only the sharply increased SCR current flow but the activated carrier recombination in the bulk region caused by defects such as contamination, dangling bonds. In addition, from the I-V measurements implemented to confirm the junction uniformity of cells, the average current dispersion was 40.87% and 10.59% at the region of SCR and QNR, respectively. These phenomena were caused by the pyramidal textured junction structure formed to improve the light absorption on the device's front surface, and these affect to the total diode current flow. These defect and textured junction structure will be causes that solar cell diodes have non-ideal electrical characteristics compared with general p-n junction diodes. Also, through the capacitance-voltage (C-V) measurements under the frequency of 180 kHz, we confirmed that the value of built-in potential is 0.63 V.

Fabrication and Its Biomedical Application of the pH-ISFET Microprobe (pH-ISFET 마이크로프로브의 製作과 그 生醫學的 應用)

  • Lee, Kwang-Man;Sohn, Byung-Ki
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.11
    • /
    • pp.1335-1341
    • /
    • 1988
  • A pH-ISEFET microprobe for in vivo measurements has been fabricated by combining ISFET (SL-IIS) chip and capillary thin film reference electrode. A two-step TCE oxidation for the gate oxide layer and multilayer encapsulation using silicone rubber and epoxy were specially used for the improvement of the stability and temperature dependence of the ISFET's. The measured sensitivit, response time and temperature dependence of the pH-ISFET microprobes are 50 mV/pH, less than one second, and - 0.01 pH/$^{\circ}$ , respectively. By operating continuously more than 40 days, a long term stability of 0.016 pH/day is obtained. The result of pH monitoring of femoral arterial blood in a rabbit is fairly good agreement with the value of blood gas analysis.

  • PDF

Evaluation of Piezoelectric Properties in Pb(Zr1Ti)O3-PVDF Composites for Thick Film Speaker Application (후막 스피커 응용을 위한 Pb(Zr1Ti)O3-PVDF 복합체의 압전 특성 평가)

  • Son Yong-Ho;Kim Sung-Jin;Kim Young-Min;Jeong Joon-Seok;Ryu Sung-Lim;Kweon Soon-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.10
    • /
    • pp.966-970
    • /
    • 2006
  • We reported on characteristics of the piezoelectric ceramic-polymer composite for the application of the thick-film speaker. The PVDF-PZT composites were fabricated to incorporate the advantages of both ceramic and polymer with various mixing ratios by 3-roll mill mixer. The composite solutions were coated by the conventional screen-printing method on ITO electrode coated PET (Polyethylene terephthalate) polymer film. After depositing the top-electrode of silver-paste, 4 kV/mm of DC field was applied at $120^{\circ}C$ for 30 min to poling the composite films. The value of $d_{33}$ (piezoelectric charge constant) was increased when the PZT weight percent was increased. The maximum value of the $d_{33}$ was 24 pC/N at 70 wt% PZT. But the $g{33}$ (piezoelectric voltage constant) showed the maximum value of $32mV{\cdot}m/N$ at 65 wt% of PZT powder. The SPL (sound pressure level) of the speaker fabricated with the 65:35 composite film was about 68 dB at 1 kHz.

Natural dyeing of silk fabric with Polygonum cuspidatum (호장근을 이용한 견직물의 천연염색)

  • Kim, Sangyool
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.5
    • /
    • pp.768-777
    • /
    • 2015
  • In this study, the dyeing of silk fabric with Polygonum cuspidatum extracts was investigated. The contents of this study are as follows. First, the proper dyeing conditions were investigated by measuring the dye uptake (K/S value) that depended on the dyeing conditions when silk fabric was dyed with Polygonum cuspidatum extract. Second, the brightness (L), hue, and chroma differences that appear after mordanting with Al, Cu and Fe were investigated by measuring the CIELAB and Munsell values. And third, the colorfastness and antibacterial property were measured. When the silk fabric was dyed with Polygonum cuspidatum extract, the proper dyeing conditions were a colorant concentration of 90% v/v, a dyeing of time 100 minutes, a dyeing temperature of $70^{\circ}C$, and a dyeing of pH 3. In mordanting methods, the dyeabilities of post-mordanting were higher than those of premordanting. The hue value displayed yellow (Y) and yellow-red (YR) in cases of pre and post mordanting. The C value decreased by the mordanting of Polygonum cuspidatum extracts. Generally the colorfastness of mordanted fabrics was improved by mordanting. The dyed fabrics showed a 90.6% of Staphylococcus aureus reduction rate, and the dyed and mordanted fabrics showed 97.1% bacteria reduction rate. The dyed and mordanted fabrics showed above 90.5% Klebsiella pneumoniae reduction rate, and Cu mordant revealed the most effective bacterial reduction.

Analysis of Biomechanics of Push-up Movement (팔 굽혀 펴기에 대한 생체역학 분석)

  • Rho, Tae-Hwan;Kim, Jeong-Hyo;Park, Si-Baek;Lee, Na-Na
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.4
    • /
    • pp.269-274
    • /
    • 2009
  • Purpose:The purpose of this study is an interval palmar width according to change of muscle activation under push-up movement. Methods:Three, this study participation normal young adult (male 3, mean age ; 24yaers). The subject performed maximum contraction under push-up movement. EMG activaty patterns is measured with three different width. The EMG activity of pectoralis major and latissimus dorsi were measured using surface electromyography. Results:EMG activation of pectoralis major and latissimus dorsi following of push-up was shown significant difference(p<.05). Also, experiment value was agree with calculation value and width of shoulder position was minimum of pectoralis major and latissimus dorsi muscle activity. Conslusion:RMS values in case of fretum and wide width of the hands on Latissimus Dorsi are shown muscle activity $132{\mu}V$ and $173.5{\mu}V$, respectively. Especialy, RMS value in terms of wide width of the hands on muscles is shown very enhanced muscle activity. It is suggest that interval palmar width of the hands on pectoralis major and latissimus dorsi in push-up movement was effective to intensify of the muscle activity.

  • PDF