• 제목/요약/키워드: P-N Curve

검색결과 456건 처리시간 0.026초

Serum miR-19a Predicts Resistance to FOLFOX Chemotherapy in Advanced Colorectal Cancer Cases

  • Chen, Qi;Xia, Hong-Wei;Ge, Xiao-Jun;Zhang, Yu-Chen;Tang, Qiu-Lin;Bi, Feng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7421-7426
    • /
    • 2013
  • Background: Colorectal cancer is the fourth most common cancer worldwide and the second leading cause of cancer-related death. FOLFOX is the most common regimen used in the first-line chemotherapy in advanced colorectal cancer, but only half of the patients respond to this regimen and we have almost no clue in predicting resistance in such first-line application. Methods: To explore the potential molecular biomarkers predicting the resistance of FOLFOX regimen as the first-line treatment in advanced colorectal cancer, we screened microRNAs in serum samples from drug-responsive and drug-resistant patients by microarrays. Then differential microRNA expression was further validated in an independent population by reverse transcription and quantitative real-time PCR. Results: 62 microRNAs expressing differentially with fold-change >2 were screened out by microarray analysis. Among them, 5 (miR-221, miR-222, miR-122, miR-19a, miR-144) were chosen for further validation in an independent population (N=72). Our results indicated serum miR-19a to be significantly up-regulated in resistance-phase serum (p=0.009). The ROC curve analysis showed that the sensitivity of serum miR-19a to discriminate the resistant patients from the response ones was 66.7%, and the specificity was 63.9% when the AUC was 0.679. We additionally observed serum miR-19a had a complementary value for cancer embryonic antigen (CEA). Stratified analysis further revealed that serum miR-19a predicted both intrinsic and acquired drug resistance. Conclusions: Our findings confirmed aberrant expression of serum miR-19a in FOLFOX chemotherapy resistance patients, suggesting serum miR-19a could be a potential molecular biomarker for predicting and monitoring resistance to first-line FOLFOX chemotherapy regimens in advanced colorectal cancer patients.

환경부 8일 유량.수질 자료를 이용한 SWAT 자동보정 모듈 개선 및 적용 평가 (Enhancement and Application of SWAT Auto-Calibration using Korean Ministry of Environment 8-Day Interval Flow/Water Quality data)

  • 강현우;류지철;강형식;최재완;문종필;최중대;임경재
    • 한국물환경학회지
    • /
    • 제28권2호
    • /
    • pp.247-254
    • /
    • 2012
  • Soil and Water Assessment Tool (SWAT) model has been widely used in estimation of flow and water quality at various watersheds worldwide, and it has an auto-calibration tool that could calibrate the flow and water quality data automatically from thousands of simulations. However, only continuous measured day flow/water quality data could be used in the current SWAT auto-calibration tool. Therefore, 8-day interval flow and water quality data measured nationwide by Korean Ministry of Environment (MOE) could not be used in SWAT auto-calibration even though long-term flow and water quality data in the Korean Total Maximum Daily Load (TMDL) watersheds available. In this study, current SWAT auto-calibration was modified to calibrate flow and water quality using 8-day interval flow and water quality data. As a result of this study, the Nash and Sutcliffe Efficiency (NSE) values for flow estimation using auto-calibration are 0.77 (calibration period) and 0.68 (validation period), and NSE value for water quality (T-P load) estimation (using the 8-day interval water quality data) is 0.80. The enhanced SWAT auto-calibration could be used in the estimation of continuous flow and water quality data at the outlet of TMDL watersheds and ungaged point of watersheds. In the next study, the enhanced SWAT auto-calibration will be integrated with Web based Load Duration Curve (LDC) system, and it could be suggested as methods of appraisal of TMDL in South Korea.

수도냉해의 발생기구와 그의 대책에 관한 연구 제1보 수도의 생장과 무기양분흡수에 미치는 온도의 영향 (Causes of Cold Damage of Rice Plant and Its Control 1. Effects of Temperature on the Growth and Absorption of Mineral Nutrients)

  • 임형빈
    • Journal of Plant Biology
    • /
    • 제17권4호
    • /
    • pp.31-37
    • /
    • 1974
  • Seedlings of Nongbaek representing strong cold tolerant variety of rice plant, Jinheung of medium variety and Tongil of weak variety were used respectively for the present study. These seedlings were water cultured in phytotron which maintained at the daytime and night temperature of 30-$25^{\circ}C$, 20-2$0^{\circ}C$, 20-15$^{\circ}C$ and 15-1$0^{\circ}C$. The growth rate of plant height, tillering rate, increase in dry weight and absorption pattern of important mineral nutrients at their early growth stage under each temperature conditions were observed. Generally, it appeared that Nongbaek was more active in the growth of plant height than Jinheung, and Jinheung was more active than Tongil under low temperature condition. The tillering rate of these three varieties was equally rapid while it was decreased in the order of weak cold tolerant variety, such as Tongil, Jinheung and Nongbaek as the temperature declined gradually. The dry weigh tincreasing curve showed almost the same pattern in the varieties at the treatment of each temperature. Under low temperature conditions, Nongbaek showed higher absorption rate of N per dry weight and higher absorption amount of per plant body, Jinheung followed and Tongil was the lowest. The absorption amount of P2O5 increased in the top part compared with the roots as temperature rose and decreased as temperature declined. There seemed to be no difference of absorption among the varieties which have different cold tolerance each other. Under low temperature the absorption rate of K per dry weight was high, as a whole, especially Nongbaek was markedly higher than the other two. The absorption rate of Ca, Mg and Fe was also equally high in all varieties under low temperature and Nongbaek showed a more absorptive tendency in the absorption amount under low temperature.

  • PDF

Cloning and Regulation of Schizosaccharomyces pombe Gene Encoding Ribosomal Protein L11

  • Kim, Hong-Gyum;Lee, Jin-Joo;Park, Eun-Hee;Sa, Jae-Hoon;Ahn, Ki-Sup;Lim, Chang-Jin
    • BMB Reports
    • /
    • 제34권4호
    • /
    • pp.379-384
    • /
    • 2001
  • The cDNA encoding ribosomal protein was identified from a cDNA library of Schizosaccharomyces pombe. The nucleotide sequence of the 548 by cDNA clone reveals an open reading frame, which encodes a putative protein of 166 amino acids with a molecular mass of 18.3 kDa. The amino acid sequence of the S. pombe L11 protein is highly homologous with those of rat and fruit, while it is clearly less similar to those of prokaryotic counterparts. The 1,044 by upstream sequence, and the region encoding N-terminal 7 amino acids of the genomic DNA were fused into the promoterless $\beta$-galactosidase gene of the shuttle vector YEp357 in order to generate the fusion plasmid pHY L11. Synthesis of $\beta$-galactosidase from the fusion plasmid varied according to the growth curve. It decreased significantly in the growth-arrested yeast cells that were treated with aluminum chloride and mercuric chloride. However, it was enhanced by treatments with cadmium chloride ($2.5\;{\mu}M$), zinc chloride ($2.5\;{\mu}M$), and hydrogen peroxide (0.5 mM). This indicates that the expression of the L,11 gene could be induced by oxidative stress.

  • PDF

유역모형을 이용한 유량조건별 배출계수 산정 및 활용방안 연구 (Study on Estimation and Application of Discharge Coefficient about Nonpoint Source Pollutants using Watershed Model)

  • 황하선;이한필;박지형;김용석;이성준;안기홍
    • 한국물환경학회지
    • /
    • 제31권6호
    • /
    • pp.653-664
    • /
    • 2015
  • TPLMS (Total water pollutant load management system) that is the most powerful water-quality protection program have been implemented since 2004. In the implementation of TPLMS, target water-quality and permissible discharged load from each unit watershed can be decided by water-quality modeling. And NPS (Non-point sources) discharge coefficients associated with certain (standard) flow are used on estimation of input data for model. National Institute of Environmental Research (NIER) recommend NPS discharge coefficients as 0.15 (Q275) and 0.50 (Q185) in common for whole watershed in Korea. But, uniform coefficient is difficult to reflect various NPS characteristics of individual watershed. Monthly NPS discharge coefficients were predicted and estimated using surface flow and water-quality from HSPF watershed model in this study. Those coefficients were plotted in flow duration curve of study area (Palger stream and Geumho C watershed) with monthly average flow. Linear regression analysis was performed about NPS discharge coefficients of BOD, T-N and T-P associated with flow, and R2 of regression were distributed in 0.893~0.930 (Palger stream) and 0.939~0.959 (Geumho C). NPS Discharge coefficient through regression can be estimated flexibly according to flow, and be considered characteristics of watershed with watershed model.

BCC계 Ti-Cr-V 합금의 전기화학적 특성에 미치는 Mn 및 $AB_5$계 합금 첨가 효과 (Effects of the Addition of Mn and $AB_5$ Type Alloy on the Electrochemical Characteristics of Ti-Cr-V BCC Type Alloys)

  • 김종연;유정현;박충년;박찬진;최전;조성욱
    • 한국수소및신에너지학회논문집
    • /
    • 제18권1호
    • /
    • pp.52-59
    • /
    • 2007
  • We investigated the effects of the addition of Mn and $AB_5$ type alloy on the electrochemical characteristics of Ti-Cr-V BCC type alloys as anode materials for Ni-MH battery. The activation behavior and discharge capacity of the BCC type alloys were significantly improved by ball-milling with the $LmNi_{4.1}Al_{0.25}Mn_{0.3}Co_{0.65}$ alloy, because the $AB_5$ type alloy acted as hydrogen path on the surface of the BCC type alloy. Among the Mn substituted alloys($Mn=0.03%{\sim}0.08%$), the $Ti_{0.32}Cr_{0.38}Mn_{0.05}V_{0.25}$ alloy ball-milled with $AB_5$ type alloy exhibited the greatest discharge capacity of $336\;mAh{\cdot}g^{-1}$. In addition, Mn substituted alloys exhibited the lower plateau pressure in P-C- T curve, the better hydrogen storage capacity and faster surface activation compared with the alloy without Mn.

Differential Absorption Analysis of Nonmagnetic Material in the Phantom using Dual CT

  • Kim, Ki-Youl;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.286-292
    • /
    • 2016
  • This study evaluates the change of computer tomography (CT) number in the case of the metal artifact reduction (MAR) algorithm, using the phantom. The images were obtained from dual CT using a gammex 467 tissue characterization phantom, which is similar to human tissues. The test method was performed by dividing pre and post MAR algorithm and measured CT values of nonmagnetic materials within the phantom. In addition, the changes of CT values for each material were compared and analyzed after measuring CT values up to 140 keV, using the spectral HU curve followed by CT scan. As a result, in the cases of N rod (trabecular bone) and E rod (trabecular bone), the CT numbers decreased as keV increasing but were constant above 90 keV. In the cases of I rod (dense bone) and K rod (dense bone), the CT numbers also decreased as keV increased but were uniform above 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of J rod (liver), D rod (liver), L rod (muscle), and F rod (muscle). For A rod (adipose), G rod (adipose), B rod (breast) and O rod (breast), the CT numbers increased as keV increased but were constant after 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of C rod (lung (exhale)), P rod (lung (exhale)), M rod (lung (inhale)) and H rod (lung (exhale)). Conclusively, because dual CT exhibits no changes in image quality and is able to analyze nonmagnetic materials by measuring the CT values of various materials, it will be used in the future as a useful tool for the diagnosis of lesions.

p" Color Field Emission Displays Using Carbon Nanotube Emitters

  • Lee, N.S.;Park, W.B.;Kim, J.M.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.211-211
    • /
    • 2000
  • Carbon nanotubes (CNTs) have been spotlighted as one of promising field emission displays(FEDs). For the first time, to authors knowledge, we have developed the 9" color CNT-FEDs with the resolution of 240x576 lines. The 9" CNT-FEDs with diode-type and triode-type structures are presented. The well-dispersed CNT paste was squeezed onto the metal-patterned cathode glass. For the anode plate, the Y2O2S:Eu, ZnS:Ag,Cl low-voltage phosphors were printed for red, green, and blue colors, respectively. The vacuum-packaged panel maintained the vacuum level of 1x10-7 Torr. The uniform moving images vacuum-packaged panel maintained the vacuum level of 1x10-7 Torr. The uniform moving images were demonstrated at 2 V/um. High brightness of 800, 200, and 150cd/m2 was observed on the green, red, and blue phosphors at V/um, respectively. Field emission characteristics of a triode-type CNT-FED were simulated using a finite element method. the resultant field strength on the cathode was modulated by gate bias and emitted electrons were focused on the anode. A relatively uniform emission image was experimentally achieved at the 800V anode. A relatively uniform emission image was experimentally achieved at the 800V anode and the 50-180 V gate biases. Energy distribution of electrons emitted from CNTs was measured using an energy analyzer. The maximum peak of energy curve corresponded to the Fermi energy level of CNTs. The whole fabrication processed of CNT-FEDs were fully scalable and reproducible. Our CNT-FEDs has demonstrated the high potential of large-area and full-color applications with very low cost fabrication and low power consumption.

  • PDF

Characterization of degradation products of the Balsalazide by Mass spectrometry: Optimization of stability-indicating HPLC method for separation and quantification of process related impurities of Balsalazide

  • Chilakabattina Naga Narasimha Babu;Ch. Srinivasa Reddy;Bhagya Kumar Tatavarti;M. Radha Madhavi;Venkateswara Rao Anna
    • 분석과학
    • /
    • 제37권1호
    • /
    • pp.25-38
    • /
    • 2024
  • The study aimed to investigate a novel approach by utilizing liquid chromatography (LC) and liquid chromatography-mass spectrometry (LC-MS) to separate, identify and characterize very nominal quantities of degradation products (DPs) of balsalazide along with its process related impurities without isolation from their reaction mixtures. The impurities along with balsalazide were resolved on spherisorb ODS2 (250×4.6 mm, 5.0 ㎛) column at room temperature using 0.2 M sodium acetate solution at pH 4.5 and methanol in the ratio of 55:45 (v/v) as mobile phase pumped isocratically at 1.0 mL/min as mobile phase and UV detection at 255 nm. The method shows sensitive detection limit of 0.003 ㎍/mL, 0.015 ㎍/mL and 0.009 ㎍/mL respectively for impurity 1, 2 and 3 with calibration curve liner in the range of 50-300 ㎍/mL for balsalazide and 0.05-0.30 for its impurities. The balsalazide pure compound was subjected to stress studies and a total of four degradation products (DPs) were formed during the stress study and all the DPs were characterized with the help of their fragmentation pattern and the masses obtained upon LC-MS/MS. The DPs were identified as 3-({4-[(E)-(4-hydroxyphenyl) diazenyl]benzoyl}amino)propanoic acid (DP 1), 4-[(E)-(4-hydroxyphenyl)diazenyl] benzamide (DP 2), 5-[(E)-(4-carbamoylphenyl)diazenyl]-2-hydroxybenzoic acid (DP 3) and 3-({4-[(E)-phenyldiazenyl]benzoyl}amino)propanoic acid (DP 4). Based on findings, it was concluded that, the proposed method was successfully applicable for routine analysis of balsalazide and its process related impurities in pure drug and formulations and also applicable for identification of known and unknown impurities of balsalazide.

경동맥 폐관류 신티그라피를 이용한 상하지 동정맥 혈관기형의 진단과 치료 평가 (Diagnosis and Post-Therapeutic Evaluation of Arteriovenous Malformations in Extremities Using Transarterial Lung Perfusion Scintigraphy)

  • 정현우;최준영;김영욱;김동익;도영수;이은정;이수진;조영석;현승협;이경한;김병태
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권6호
    • /
    • pp.316-321
    • /
    • 2006
  • 목적: 동정맥 혈관기형은 혈역학적 변화를 일으켜 생명에 위험을 줄 수 있으므로, 사지의 선천성 혈관기형 환자에서 동정맥 혈관기형과 비동정맥 혈관기형을 정확히 감별진단 하는 것이 중요하다. 이 연구에서는 혈관조영술과 비교하여 경동맥 폐관류 신티그라피(transarterial lung perfusion scintigraphy, TLPS)가 선천성 혈관기형 중 상하지에 위치하는 동정맥 혈관기형의 진단과 치료 효과 평가에 유용한 지를 알아보았다. 대상 및 방법: 색전술/경화요법 전에 처음 TLPS를 시행 받은 57명(나이: $21{\pm}13$세, 남:여 = 26:31)이 연구대상이 되었다. 병변의 위치는 상지가 9명이었고 하지가 48명이었다. TLPS에서 폐의 시간 방사능 곡선을 이용하여 혈액 단락량을 구하였다. 모든 환자들에서 혈관조영술을 시행하여 혈관기형의 해부학적 및 혈역학적 평가를 하였다. 혈관조영술로 동전맥 혈관기형이 진단된 환자들은 치료 후 TLPS를 추적 시행하였다. 결과: 혈관조영술상 16명은 동정맥 혈관기형(상지 8명, 하지 8명), 나머지 41명은 비동정맥 혈관기형(상지 1명, 하지 40명)으로 진단되었다. 동정맥 혈관기형 환자들의 치료 전 평균 혈액 단락량은 비동정맥혈관기형 환자들에 비하여 유의하게 높았다($66.4{\pm}25.8%\;vs.\;2.8{\pm}4.3%$, p<0.0001). TLPS의 치료 전 상하지 동정맥 혈관기형을 진단하는 예민도와 특이도, 정확도는 각각 93.8% (15/16), 100% (41/41), 98.2% (56/57)이었다(혈액 단락량 기준 역치 = 20%). 동정맥 혈관기형 환자 16명은 추적 TLPS를 시행하였고 이 중 13명은 치료 평가에서 혈관조영술과 일치하는 결과를 보여주었다(81.3%). 색전술/경화요법 시행 후 TLPS 혈액 단락량은 유의하게 감소하였다($69.5{\pm}24.0%\;vs.\;41.0{\pm}34.7%$, p = 0.01). 결론: TLPS는 상하지동정맥 혈관기형에서 혈액 단락량의 반정량적인 정보를 제공해주며 혈관 조영술과 높은 검사결과 일치도를 보여주었다. 그러므로, TLPS는 상하지 동정맥 혈관기형의 진단과 치료 평가에 유용하다.