• Title/Summary/Keyword: P/C Based Method

Search Result 944, Processing Time 0.032 seconds

2D Correlation Analysis of Spin-Coated Films of Biodegradable P(HB-co-HHx)/PEG Blends

  • Kim, Min-Kyung;Ryu, Soo-Ryeon;Noda, Isao;Jung, Young-Mee
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.11
    • /
    • pp.4005-4010
    • /
    • 2011
  • We investigated thermal behavior of spin-coated films of P(HB-co-HHx)/PEG blends by using infraredreflection absorption (IRRAS) spectroscopy and 2D correlation spectroscopy. Based on 2D IRRAS correlation spectra, we could determine the sequence of spectral intensity changes with increasing temperature that PEG band changes first and then a band for crystalline component of P(HB-co-HHx) changes before a band for amorphous component. The intensities of bands for PEG and amorphous P(HB-co-HHx) were changed greatly as PEG weigh % of P(HB-co-HHx)/PEG blends increased. Transition temperatures of P(HB-co-HHx)/PEG blends were successfully determined by 2D gradient mapping method. The transition temperature of spincoated films of 98/2 and 90/10 P(HB-co-HHx)/PEG blends and 80/20 P(HB-co-HHx)/PEG blend determined by 2D gradient map are, respectively, about 137.5 and $132.5^{\circ}C$. Furthermore, P(HB-co-HHx)/PEG blends show an additional transition temperature that have been interpreted in terms of different lamellar thicknesses in spin coated films.

Alanysis of the Optical Properties of p-type ZnO Thin Films Doped by P based on Ampouele-tube Method (Ampoule-tube 법으로 Phosphorus를 도핑한 P형 ZnO 박막의 광학적 특성 분석)

  • Yoo, In-Sung;Oh, Sang-Hyun;So, Soon-Jin;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.145-146
    • /
    • 2006
  • The most Important research topic in the development of ZnO LED and LD is the production of p-type ZnO thin film that has minimal stress with outstanding stoichiometric ratio. In this study, Phosphorus diffused into the undoped ZnO thin films using the ampoule-tube method for the production of p-type znO thin films. The undoped ZnO thin films were deposited by RF magnetron sputtering system on $GaAs_{0.6}P_{0.4}$/GaP and Si wafers. 4N Phosphorus (P) was diffused into the undoped ZnO thin films in ampoule-tube which was performed and $630^{\circ}C$ during 3hr. We found the diffusion condition of the conductive ZnO films which had p-type properties with the highest mobility of above 532 $cm^2$/Vs compared with other studies PL spectra measured at 10K for the purpose of analyzing optical properties of p-type ZnO thin film showed strong PL intensity in the UV emission band around 365nm ~ 415nm and 365nm ~ 385nm.

  • PDF

Studies of plant Tumor induction (III) - Antimicrobial action of some bacteriacidal agents to obtain Bacteria-Free Tumor tissue (식물의 암종유발에 관한 연구 (제 3보) - Bacteria-free 암종조직의 획득에 있어서 항생제의 효과)

  • 이민재;홍순우;최영길
    • Korean Journal of Microbiology
    • /
    • v.5 no.2
    • /
    • pp.97-101
    • /
    • 1967
  • Up to the present time, there are only three methods by which we can obtain bacteria free crown gall tissue. According to some papers related to this field, the first method is based on the works of Braun(53') who maintained infected plants at 46-47'c for several days. But the method has a problem that very few plants can tolerate this temperature. The second method is based on the well known observation that old tumors appear to be bacteria free at least 1 or 2% of the explants. Also this method is known to us as laborious and time consuming. The third method is the one we were using that was attempting to kill the bacteria with bacteriacidal agent such as Antibiotics. In fact., it is reported that almost complete control of crown gall of tomato was obtained by Blanchard('51) when plants were grown in a nutrient containing Aureomycin(20${\mu}g$/ml) following needle puncture with the gall bacteria. We have been engaged in making the experiment by applying solution of Penicillin, Streptomycin and of Chloramphenicol(Succinate free) to find the strong bacteriacidal agent through the method of disc plate, and to confirm the effect of antimicrobial action through the method of plant tissue culture system without possible injury to the host plant. The result of this report is the fact the strongest bacteriacidal agent among the above three Antibiotics was Chloramphenicol(Succinate free 1000 p.p.m). and that there happened no injury to the tissue cultures in a White's 10X media containing 1000 p.p.m. of Chloramphenicol.

  • PDF

Decision-making process and satisfaction of pregnant women for delivery method (임산부의 분만방법 결정과정과 만족도)

  • Jun, Hae-Ri;Park, Jung-Han;Park, Soon-Woo;Huh, Chang-Kyu;Hwang, Soon-Gu
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.4 s.63
    • /
    • pp.751-769
    • /
    • 1998
  • This study was conducted to assess the attitude of pregnant women toward delivery method, understanding of the reason for determining her own delivery method, participation in decision-making process and satisfaction with delivery method after labor. Study subjects were 693 pregnant women who had visited obstetric clinic for prenatal care in the last month of pregnancy in one general hospital and one obstetrics-gynecology specialty hospital in Taegu city from February 1 to March 31 in 1998. A questionnaire was administered before and after labor and a telephone interview was done one month after labor. Proportion of women who had health education and/or counselling about delivery method during prenatal care was 24.0% and this proportion was higher for women who had previous c-section(35.5%) than others. Women thought vaginal delivery is better than c-section for both maternal and baby's health regardless of previous delivery method. About 90% of primipara and multiparous women who had previous vaginal delivery wanted vaginal delivery for the index birth, while 85.6% of multiparous women who had previous c-section wanted repeat c-section. Reasons for choosing c-section in pregnant women who preferred vaginal delivery before labor were recommendation of doctors(81.9%), recommendation of husband (0.8%), agreement between doctor and pregnant woman(4.7%), and mother's demand (12.6%). Reasons for choosing vaginal delivery were mother's demand(30.6%) and no indication for c-section(67.2%). Reasons for choosing c-section in pregnant women who preferred c-section before labor were recommendation of doctors(76.2%), mother's demand(20.0%), recommendation of husband(1.3%), and agreement between doctor and pregnant woman(2.5%). Of the pregnant women who had c-section, by doctor's recommendation, the proportion of women who had heard detailed explanation about reason for c-section by doctor was 55.1%. Mother's statement about the reason for c-section was consistent with the medical record in 75.9% . However, over 5% points disparities were shown between mother's statement and medical record in cases of the repeat c-section and mother's demand. In primipara and multiparous women who had previous vaginal delivery, the delivery method for index birth had statistically significant association with the preference of delivery method before labor(p<0.05). All of the women who had previous c-section had delivered the index baby by c-section. Among mothers who had delivered the index baby vaginally, 84.9% of them were satisfied with their delivery method immediately after labor and 85.1% at 1 month after labor. However, mothers who had c-section stated that they are satisfied with c-section in 44.6% immediately after labor and 42.0% at 1 month after labor. Preferred delivery method for the next birth had statistically significant association with delivery method for the index birth both immediately after labor and in 1 month after labor. The proportion of mothers who prefer vaginal delivery for the next birth increased with the degree of satisfaction with the vaginal delivery for the index birth but the proportion of mothers who prefer c-section for the next birth was high and they did not change significantly with the degree of satisfaction with the c-section for the index birth. These results suggest that the current high technology-based, physician-centered prenatal and partritional cares need to be reoriented to the basic preventive and promotive technology-based, and mother-fetus-centered care. It is also suggested that active involvement of pregnant woman in decision-making process for the delivery method will increase the rate of vaginal birth after c-section and decrease c-section rate and improve the degree of maternal satisfaction after delivery.

  • PDF

Classification of Online and Offline linked Advertisements in 4th Industrial Revolution (4차 산업혁명 시대에 따른 온라인과 오프라인 연계 광고의 유형화)

  • Kim, Eun Seo;Park, Jae Wan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.147-153
    • /
    • 2020
  • The purpose of this study is to suggest the value and type of online and offline linked advertisement, which is a new advertisement type that emerged with the advent of the 4th industrial revolution. In this study, based on literature research, we understood the marketing method that evolves from "4P (product, price, place, promotion)" to "4C (co-creation, community, conversation, currency)" and extracted derive 4C elements. Based on this, we analyzed what elements of 4C showed online and offline connectivity through the investigation of on and offline linked advertisements. Through the analysis results, online and offline linked advertisements were classified into 4 types and 14 detailed types according to how they were connected to the number of 4C elements. In this paper, as a final result, we verified that 4C elements of marketing that appeared in the era of the 4th Industrial Revolution are represented in advertisements and suggested the typology of advertisements accordingly. This study is expected to contribute to providing new insights to advertisers and researchers who produce and study online and offline advertisements.

Thermal Analysis and Design of AlGaInP-based Light Emitting Diode Arrays

  • Ban, Zhang;Liang, Zhongzhu;Liang, Jingqiu;Wang, Weibiao;JinguangLv, JinguangLv;Qin, Yuxin
    • Current Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.143-149
    • /
    • 2017
  • LED arrays with pixel numbers of $3{\times}3$, $4{\times}4$, and $5{\times}5$ have been studied in this paper in order to enhance the optical output power and decrease heat dissipation of an AlGaInP-based light emitting diode display device (pixel size of $280{\times}280{\mu}m$) fabricated by micro-opto-electro-mechanical systems. Simulation results showed that the thermal resistances of the $3{\times}3$, $4{\times}4$, $5{\times}5$ arrays were $52^{\circ}C/W$, $69.7^{\circ}C/W$, and $84.3^{\circ}C/W$. The junction temperature was calculated by the peak wavelength shift method, which showed that the maximum value appears at the center pixel due to thermal crosstalk from neighboring pixels. The central temperature would be minimized with $40{\mu}m$ pixel pitch and $150{\mu}m$ substrate thickness as calculated by thermal modeling using finite element analysis. The modeling can be used to optimize parameters of highly integrated AlGaInP-based LED arrays fabricated by micro-opto-electro-mechanical systems technology.

P-version Finite Element Analysis of the Irregular Shaped Plates with Singularities (특이성을 갖는 비정형 평판의 p-version 유한요소해석)

  • 우광성
    • Computational Structural Engineering
    • /
    • v.3 no.3
    • /
    • pp.101-111
    • /
    • 1990
  • The elastic analysis of floor slabs using the p-version of finite element method encounters stress singularities at certain types of reentrant corners, openings and cut-outs. Results obtained using the computer code based on C.deg. - hierarchic plate element formulated by Reissner-Mindlin theory are compared with theoretical predictions and with computational results reported in the literature. The convergence rate of h-, p- and hp-version can be estimated on the basis of the energy norm in global sense. If accuracy in terms of the number of degree-of-freedom is used as a criterion, the solutions presented here are the most efficient that have been published up to date. Examples are the rhombic plate with the obtuse angle of 150.deg. and the square plate with cut-outs.

  • PDF

An Efficient Approach for Cloning P450 Hydroxylase Genes from Actinomycetes

  • Hyun, Chang-Gu;Kim, Jung-Mee;Hong, Soon-Kwang;Suh, Joo-Won
    • Journal of Microbiology and Biotechnology
    • /
    • v.8 no.3
    • /
    • pp.295-299
    • /
    • 1998
  • Oligonucleotide primers were designed and successfully applied to amplify DNA fragments of P450 hydroxylase genes from actinomycetes which produce a large variety of medically important metabolites. Primers were designed based on several regions of strong similarities in amino acid sequence of P450 hydroxylases from a variety of actinomycetes, primarily in the regions of an oxygen binding site and a heme ligand pocket. These primers were used to amplify DNA fragments from seven different actinomycetes species producing a variety of different compounds. The deduced amino acid sequences of the isolated fragments revealed significant similarities to known P450 hydroxylase including the product of the suaC or subC genes from Streptomyces griseolus that is capable of metabolizing a number of sulfonylurea herbicides, and to the product of the $P450_{sca2}$ from S. carbophilus that produces a specific HMG-CoA reductase inhibitor. This method should help researchers in cloning the P450 hydroxylase genes involved in the biosynthesis of useful compounds.

  • PDF

A New Prediction Method for Scintillation Expression

  • Chutchavong, Vanvisa;Nakasuwan, Jintana;Sangaroon, Ornlarp;Jenchitrapongvej, Kanok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2082-2086
    • /
    • 2003
  • This paper presents the analysis of satellite received signal by focus on the new prediction method for amplitude scintillation expression. A predict method based in the relationship of standard deviation values and the peak to peak values of amplitude scintillation in various of time period and various of sampling rate of signal variation. The principal techniques finding, the proper sampling rate and time interval, for the best expression method. The experiment has been performed in Bangkok of Thailand, at King Mongkut's Institute of Technology, Ladkrabang, data collected in C-Band and Ku-Band on high elevation angles. The result of analysis shows the relationship between two methods is given by ${\sigma}_x={\alpha}(P-P)+{\beta}$. The value of ${\alpha}$ depends on sampling rate by closely with three-minute maximum time interval.

  • PDF

UHF Narrow Band Type Partial Discharge Diagnosis Method for the Internal Insulation Performance Verification of the Gas Insulated Switchgear (가스절연 개폐장치의 내부절연 성능검증을 위한 UHF 협대역 부분방전 진단법)

  • Song Won-Pyo;Kim Jung-Bae;Kim Min-So;Jung Jae-Ryong;Park Seung-Jae;Ko Heui-Suk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.9
    • /
    • pp.414-420
    • /
    • 2005
  • A method for partial discharge diagnosis based on UHF narrow band type for GIS has been developed and calibrated. In generally, PD cannot be directly measured under on-line condition, but we can indirectly measure the electromagnetic wave made by PD using the high-frequency antenna. Compared with VHF band, electromagnetic waves of UHF band have a low influence for external noise in high-voltage substation. Therefore, we can detect the real abnormality with several pC in GIS using UHF narrow-band type method. For the case of no internal VHF sensor for GIS of the domestic substation, it has applied to use the external UHF sensor attached in spacer in GIS of existing substation. In this paper, we firstly described the technique of partial discharge measurement using frequency analysis and phase analysis in UHF band. Secondly, we presented the results of sensitivity test, the relationship of dBm-pC and diagnosis result of the cause of PD source by phase analysis. And then, we report the diagnosis result of partial discharge on the real GIS in domestic substation. These results make above method applicable for measurement of quantity and cause of PD for real operation GIS in high-voltage substation.