• Title/Summary/Keyword: P(Y) code

Search Result 583, Processing Time 0.026 seconds

Analysis on Software Static Testing Results of Railway Signaling System (열차제어시스템 소프트웨어 정적 테스팅 적용시험 결과 분석)

  • Hwang, Jong-Gyu;Jo, Hyun-Jeong;Jeong, Rak-Gyo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.1
    • /
    • pp.30-35
    • /
    • 2013
  • Many function of railway signalling system which is in charge of most core function in a railway system are being operated by the software according to the development of computer technology. Accordingly, the source code testing to verify the safety of the railway signalling system software becomes to be more important, and related international standards highly recommend verifications on the source code also. For this reason, several related studies on vital source code verification were executed from several years ago in Korea. This paper performed tests through the application to railway signalling system being applied to the existing actual domestic railway sites through automated testing tools for coding rules of signalling system software and another signaling system software under development in Korea recently, and analyzed their results.

A Fault Diagnosis Method of Oil-Filled Power Transformers Using IEC Code based Neuro-Fuzzy Model (IEC 코드 기반의 뉴로-퍼지모델을 이용한 유입변압기 고장진단 기법)

  • Seo, Myeong-Seok;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.1
    • /
    • pp.41-46
    • /
    • 2016
  • It has been proven that the dissolved gas analysis (DGA) is the most effective and convenient method to diagnose the transformers. The DGA is a simple, inexpensive, and non intrusive technique. Among the various diagnosis methods, IEC 60599 has been widely used in transformer in service. But this method cannot offer accurate diagnosis for all the faults. This paper proposes a fault diagnosis method of oil-filled power transformers using IEC code based neuro-fuzzy model. The proposed method proceeds two steps. First, IEC 60599 method is applied to diagnosis. If IEC code can't determine the fault type, neuro-fuzzy model is applied to effectively classify the fault type. To demonstrate the validity of the proposed method, experiment is performed and its results are illustrated.

Design in shear of reinforced concrete short columns

  • Moretti, M.L.;Tassios, T.P.
    • Earthquakes and Structures
    • /
    • v.4 no.3
    • /
    • pp.265-283
    • /
    • 2013
  • This research was prompted by the paucity of specific code provisions regarding the design of short columns for shear. The purpose of this paper was to investigate whether the use of the normal shear design procedure of various codes may or may not be applied to reliably calculate the shear strength of short columns. Provisions of the codes American ACI 318M-08, Canadian CSA A23.3-04, Japanese AIJ Guidelines, New Zealand NZS 3101, European EN 1998 (EC8) parts 1 and 3, combined with EN 1992-1-1 (EC2), and draft fib Model Code 2010, as well as a strut-and-tie model are applied on short columns tested under cyclic loading that failed in shear. Actual shear resistances are compared to predictions, and the resulting shortcomings of the codes are identified. EN1998-3 appears to be the only code among those considered that may be reliably applied to estimate the shear resistance of short columns. Further, the proposed strut-and tie model can be a useful tool for the detailed design and assessment of short columns.

Delayed Parallel Interference Cancellation for GPS C/A Code Receivers

  • Glennon, Eamonn P.;Bryant, Roderick C.;Dempster, Andrew G.
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.261-266
    • /
    • 2006
  • A number of different techniques are available to mitigate the problem of cross correlations caused by the limited dynamic range of the 10-bit Gold codes in the GPS C/A code. These techniques include successive-interference cancellation (SIC) and parallel-interference cancellation (PIC), where the strong signals are subtracted at IF prior to attempting to detect the weak signals. In this paper, a variation of these techniques is proposed whereby the subtraction process is delayed until after the correlation process, although still employing a pure reconstructed C/A code signal to permit prediction of the cross correlation process. The paper provides details on the method as well as showing the results obtained when the method was implemented using a software GPS receiver. The benefits of this approach are also described, as is the application of the method to the cancellation of CW interference.

  • PDF

Perception and Performance about Patients' Medical Information Protection in Allied Health College Students (보건계열 대학생의 환자 의료 정보 보호에 대한 인식과 수행)

  • Choi, Seon Young;Lim, Do Yeon;Ko, Il Sun;Moon, In Oh
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.22 no.1
    • /
    • pp.83-95
    • /
    • 2016
  • Purpose: This study aims to identify perception, performance, and the related factors of performance in regards to patients' medical information protection among allied health college students. Methods: Four hundred twelve subjects from three colleges located in Jeonbuk and Kyungbuk province consented to participate. Data was collected from November 28 to December 15, 2012. To assess perception and performance in regards to patients' medical information protection, a self-reporting questionnaire was used. Data was analyzed via SPSS 18.0 program. Results: The score of perception and performance about patients' medical information protection were 4.07 and 3.56, respectively. All item's scores of performance were significantly lower than those of perception. The perception score was significantly different according to recognition of hospital ethics code (t=1.95, p=.052), and recognition of association ethics code (t=2.88, p=.004). The performance score was significantly different according to gender (t=-3.32, p=001), major (F=14.41, p<.001), clinical practicum hospitals (F=8.22, p<.001), and method of electronic medical record access (F=3.23, p=.023). The factors influencing performance were perception(${\beta}=.46$, p<.001), duration of clinical practice(${\beta}=-.36$, p<.001), and gender(${\beta}=.09$, p=.033). Conclusion: In order to improve performance in regards to patients' medical information protection of allied health college students, we should develop ethical education programs and standardize them through multidisciplinary collaboration.

Example of the Structural Design with Applied SNiP codes in the Commonwealth of Independent States (CIS) (CIS 국가 내진 설계 방법과 SNiP Code를 적용한 주거시설 구조설계 사례)

  • Lee, Dong-Woo;Kwak, Chul-Seung;Jeong, Hoon-Sik
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.232-237
    • /
    • 2008
  • In the Commonwealth of Independent States (CIS), the international organization, or alliance, consisting of eleven former Soviet Republics, their own regulation and standard, codes of the building are based on SNiP issued from the Russia. The SNiP for the seismicity is based on Kazakhstan codes where earthquake is very strong. After their independence, Seismic codes for Former Soviet Republics have been developed in their own accord. The building subjected by more than certain magnitude should be followed by TU as well as SNiP. In this paper, the residential complex project where seismic stability is considered from schematic design will be introduced. In this project, Local analysis program and method for arrangement of bar was applied. In the structural drawings, Korean and Local methods was compromised.

  • PDF

An Evaluation Method for Tornado Missile Strike Probability with Stochastic Correlation

  • Eguchi, Yuzuru;Murakami, Takahiro;Hirakuchi, Hiromaru;Sugimoto, Soichiro;Hattori, Yasuo
    • Nuclear Engineering and Technology
    • /
    • v.49 no.2
    • /
    • pp.395-403
    • /
    • 2017
  • An efficient evaluation method for the probability of a tornado missile strike without using the Monte Carlo method is proposed in this paper. A major part of the proposed probability evaluation is based on numerical results computed using an in-house code, Tornado-borne missile analysis code, which enables us to evaluate the liftoff and flight behaviors of unconstrained objects on the ground driven by a tornado. Using the Tornado-borne missile analysis code, we can obtain a stochastic correlation between local wind speed and flight distance of each object, and this stochastic correlation is used to evaluate the conditional strike probability, $Q_V(r)$, of a missile located at position r, where the local wind speed is V. In contrast, the annual exceedance probability of local wind speed, which can be computed using a tornado hazard analysis code, is used to derive the probability density function, p(V). Then, we finally obtain the annual probability of tornado missile strike on a structure with the convolutional integration of product of $Q_V(r)$ and p(V) over V. The evaluation method is applied to a simple problem to qualitatively confirm the validity, and to quantitatively verify the results for two extreme cases in which an object is located just in the vicinity of or far away from the structure.

Performance Analysis of PCM Cell Search Algorithm for Fast Cell Search in WCDMA Systems (WCDMA. 시스템에서 빠른 셀 탐색을 위한 극성 변조 셀 탐색 알고리즘의 성능 분석)

  • 배성오;임재성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.8A
    • /
    • pp.598-606
    • /
    • 2003
  • In this paper, we analyze the performance of the PCM cell search algorithm proposed for fast cell search of WCDMA systems. In order to improve both performance and complexity of the cell search algorithm standardized for WCDMA systems the PCM scheme uses a group of the polarization codes produced by a Gold code generator. The PCM scheme only uses one synchronization channel since the polarization codes modulated on P-SCH can replace the RS codes of S-SCH. Thus, the PCM reduces the BS's transmission power since only one synchronization channel can be used, and it can also reduce the complexity of receiver as compared with the conventional one. In this paper, by defining a numerical model, we analyze the performance of the PCM cell search algorithm in terms of detection probability and mean acquisition time. Consequently, we could demonstrate that the PCM cell search algorithm is superior to the standard WCDMA cell search algorithm.

Analysis of Simple Creep Stress Calculation Methods for Creep Life Assessment (크리프 수명 평가를 위한 간략 크리프 응력 산출 방법론 분석)

  • Seo, Jun Min;Lee, Han Sang;Kim, Yun Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.703-709
    • /
    • 2017
  • Creep analysis takes much more time than elastic or elastic-plastic analysis. In this study, we conducted elastic and elastic-plastic analysis and compared the results with creep analysis results. In the elastic analysis, we used primary stress, which can be classified by the $M{\alpha}-tangent$ method and stress intensities recommended in the ASME code. In the elastic-plastic analysis, we calculated the parameters recommended in the R5 code. For the FE models, a bending load, uniaxial load, and biaxial load were applied to the cross shaped welded plate, and a bending load and internal pressure were applied to the elbow pipe. To investigate the element size sensitivity, we conducted FE analysis for various element sizes for the cases where bending load was applied to the cross shaped welded plate. There was no significant difference between the creep stress and the alternative methods; however, in the $M{\alpha}-tangent$ method, the results were affected by the element size.

Transmutation of Am-241, 243 and Cm-244 in a Conventional Pressurized Water Reactor

  • Koh, Duck-Joon;Lee, Myung-Chan;Jeong, Woo-Tae;Boris P. Kochurov
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.423-428
    • /
    • 1996
  • The feasibility study on burning Am-241, 243 and Cm-244 nuclides in a conventional PWR (Pressurized Water Reactor) was carried out by using the TRIFON code that was developed by the Institute of Theoretical and Experimental Physics in Russia in 1992. TRIFON code uses updated ABBN Russian nuclear cross section library. The reference reactor is the Korea nuclear power plant unit 8 (YGN 2). The burning effect of Am-241, 243 and Cm-244 nuclides was studied with UO$_2$(3.5 w/o)fuel assembly and MOX (4.44 w/o) fuel assembly. The loaded mass ratio of Am-241, 243 and Cm-244 nuclides was obtained from the mass ratio of Am-241, 243 and Cm-244 nuclides in 10 year cooling spent fuel with average discharge burnup of 33 GWD/MTU. The effective transmutation rates of Am-241, 243 and Cm-244 nuclides in UO$_2$ fuel assembly were found to be higher than those in MOX fuel assembly. The result from TRIFON code was compared to that from CASMO-3/NEM-3D code system. For more reliable calculation of transmutation for MA(Minor Actinides) more sophisticated decay chain scheme of MA should be investigated and nuclear cross section library of MA should be considerably improved.

  • PDF