• Title/Summary/Keyword: Ozonizer

Search Result 114, Processing Time 0.023 seconds

Ozone Production Characteristics of the DBD Discharge the Electrode Shape at the Same Electrode surface area (동일한 전극 표면적에서 DBD방전형 내부전극 형상에 따른 오존생성특성 연구)

  • Kwon, Young-Hak;Park, Hyunmi;Song, HyunGig;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.71-77
    • /
    • 2016
  • The dielectric barrier discharge (DBD) has low efficiency due to about 70% input power is consumed as thermal energy in the discharge space. However, because of the usage of DBD ozone generator is easier than other methods. The DBD ozone generator has been widely applied for high concentration ozone generation in the industrial application. But, the low-capacity compact DBD ozone generator is not applied so far. Therefore, the DBD ozone generator is necessary to improve ozone production efficiency and reduce the capacity. In this paper, the stainless steel pipe inner electrode was designed with hall type and screw type to improve the ozone production yield. The manufactured two inner electrodes were experimented with normal type for comparison of the discharge characteristics and the ozone generating characteristics. As the experimental results, the discharge current effective value of designed inner electrodes with hall type and screw type are higher than the normal type, due to unequal electric field is formed at the boundary. However, the difference of designed and original electrodes is less than 0.1mA that has no effect on the discharge characteristic. On the other hand, the screw type inner electrode increased higher than original model about 7 times when the flow rate of the oxygen source gas was increased from $0.6{\ell}/min$ to $1.0{\ell}/min$ The reason was assumed by the flow rate of the raw gas through the inner electrode was became fast that has a cooling effect. The designed hall type and screw type inner electrodes have shown good performances in ozone generation and ozone production that better than normal type in the same electrode surface area.

A Study on the Improved Lamp Ttpe Ozonizer(ILO) (개선된 램프형 오존발생기에 관한 연구)

  • Rahman, Fayzur;Lee, Sang-Keun;Chun, Byung-Joon;Song, Hyun-Jig;Lee, Kwang-Sik;Lee, Dong-In
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.109-117
    • /
    • 1999
  • In this paper, improved lamp type ownizer( ILO ), which utilizes the superposition of lamp type ownizer( LO ) and surface discharge operation, is designoo and manufactured for the purpose of characteristic improverrent of an LO employoo for installation of environrrent improverrent and good health using Ultraviolet(U.V.) photochemical reactions Irethoc1s. The ownizer consists of 2 types( LO and ILO ), and owne concentration, owne generation and owne yield were investigated in accordance with discharge power and quantity of suwlioo gas. The results of owne concentration, owne generation and owne yield were ILO > LO. So, owne generation characteristics of the lamp type ownizer were improved. At a discharge power of 19[W], owne concentration, owne generation, and owne yield of the ILO are each improvoo than LO 124[%] at the gas flow $1[\ell/min]$ and 143[%] at the gas flow $1[\ell/min]$. The maximum values of owne concentration, owne generation and owne yield were found as 712[ppm], 128[mg/h] and 6750[mg/kWh] respectively.tively.

  • PDF

A Study on Cooling Effect and Power Control of a Mini Ozonizer (소형 오존발생장치의 전력제어와 냉각효과에 관한 연구)

  • Woo, Sung-Hoon;Park, Seung-Cho;Yoon, Sung-Yoon;Park, Jee-Ho;Woo, Jung-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.97-103
    • /
    • 2006
  • In this paper, a control method of a mini ozone generator is proposed, and also a cooling technique is described which is cooling down the flowing air gap into a silent discharger to $2^{\circ}C$ to generate ozone of high density and diffusing power. As the digital control system for this method, a double feedback loop is designed which detects the voltage and current of equivalent capacitor of the discharger and compensates for the poor power waveform caused by the noise at high discharging frequency. During the plant modeling of this system, computing time factor is considered as a unique parameter of the power system to improve the transient responses with regard to fluctuating load and to replenish the computing time delay of the controller. Through the experiment, sinusoidal input current for discharger can be acquired and all the effectiveness of this accurate control system over unstable ozone discharger are proved.

Development of Ozone Generation Technology Using Gaseous Electrical Discharge for Environment Improvement (환경개선용 기체전기방전을 이용한 오존발생기술 개발)

  • 이동헌;송현직;구건효
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.25-34
    • /
    • 2001
  • In this paper, discharge lamp ozonizer(DLO) of a new discharge type using superposition of gaseous electrical discharge for environment improvement was designed and manufactured. DLO is equipped with 3 electrodes(central ground electrode of discharge lamp type internal high voltage electrode of mesh type and external high voltage electrode of spiral type), and it is composed of double gap(gap between discharge lamp and internal electrode, gap between discharge lamp and external electrode). Internal and external electrodes are respectively applied AC high voltage which has 180[$^{\circ}$] phase difference. Ozone is generated by overlaying of each silent discharge which is respectively came from two gaps. At the moment discharge characteristics and ozone generation characteristics of DLO were investigated in accordance with quantity of supplied gas, discharge power and the number of DLO. When ozone generated by DLO was in contact with NO gas, removal characteristics was excellent, so it confirmed that DLO could be used as air environment improvement facility.

  • PDF