• Title/Summary/Keyword: Ozone Process

Search Result 421, Processing Time 0.024 seconds

ULTRA-FINE PARTICLES AND GASEOUS VOLATILE ORGANIC COMPOUND EXPOSURES FROM THE REACTION OF OZONE AND CAR-AIR FRESHENER DURING METROPOLIS TRAVEL

  • Lamorena, Rheo B.;Park, Su-Mi;Bae, Gwi-Nam;Lee, Woo-Jin
    • Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.72-80
    • /
    • 2007
  • Experiments were conducted to identify the emissions from the car air freshener and to identify the formation of ultra-fine particles and secondary gaseous compounds during the ozone-initiated oxidations with emitted VOCs. The identified primary constituents emitted from the car air freshener in this study were $\alpha$-pinene, $\beta$-pinene, $\rho$-cymene and limonene. Formation of ultra-fine particles (4.4-160 nm) was observed when ozone was injected into the chamber containing emitted monoterpenes from the air freshener. Particle number concentrations, particle mass concentrations, and surface concentrations were measured in time dependent experiments to describe the particle formation and growth within the chamber. The irritating secondary gaseous products formed during the ozone-initiated reactions include formaldehyde, acetaldehyde, acrolein, acetone, and propionaldehyde. Ozone concentration (50 and 100 ppb) and temperature (30 and $40^{\circ}C$) significantly affect the formation of particles and gaseous products during the ozone-initiated reactions. The results obtained in this study provided an insight on the potential exposure of particles and irritating secondary products formed during the ozone-initiated reaction to passengers in confined spaces.

A Study on the Pretreatment Process for Sewage Reuse by Microfiltration Process (정밀여과에 의한 하수고도처리수의 재이용을 위한 전처리법에 관한 연구)

  • Kuk, Young-Long;Joo, Jae-Young;Bae, Yoon-Sun;Lee, Hye-In;Jung, In-Ho;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.595-601
    • /
    • 2010
  • It is evident that Korea will continue its battle with water shortage and alternative program are being taken into action. One of the main actions is reusing 1,800 tons of effluent of 357 sewage treatment plant located nationwide. Therefore this study supplemented ozone oxidation methods that would increase the efficiency of organic oxidation and coagulation. Through this method, fouling will be controled sufficiently by preventing membrane process in the system for advanced sewage treatment. In this study, ozone-coagulation-microfiltration membrane were used. The final removal efficiency of the pretreated water from the result of the ozone-coagulation were 50% of CODcr, 38% of TP and 11% of TOC respectively. Water quality treatment has decreased about 80% for TP. Ozone-coagulation-microfiltration membrane maintains the high flux while decreasing the number of organic matter and the membrane fouling, and reducing the TP. As a result, in order to reuse the water from the sewage, the ozone-coagulation-microfiltration membrane type must be considered in order to achieve the best efficiency.

Development of the DIW-$O_3$ Cleaning Technology Substituted for the Semiconductor Photoresist Strip Process using the SPM (SPM을 이용한 반도체 포토레지스트 제거 공정 대체를 위한 DIW-$O_3$ 방식 세정기술 개발)

  • Son, Yeong-Su;Ham, Sang-Yong
    • 연구논문집
    • /
    • s.33
    • /
    • pp.99-109
    • /
    • 2003
  • Recently the utilization of the ozone dissolved de-ionized water(DIW-$O_3$) in semiconductor wet cleaning process and photoresist stripping process to replace the conventional sulfuric acid and hydro peroxide mixture(SPM) method has been studied. In this paper, we propose the water-electrode type ozone generator which has the characteristics of the high concentration and purity to produce the high concentration DIW-$O_3$ for the photoresist strip process in the semiconductor fabrication. The proposed ozone generator has the dual dielectric tube structure of silent discharge type and the water is both used to electrode and cooling water. Through this study, we obtained the results of the 10.3 wt% of ozone gas concentration at the oxygen gas of 0.5 [liter/min.] and the DIW-$O_3$ concentration of 79.5 ppm.. Through the photoresist stripping test using the produced DIW-$O_3$, we confirmed that the photoresist coated on the silicon wafer was removed effectively in the 12 minutes.

  • PDF

Ozone Effect on the Formation of Chlorine Disinfection Byproducts in Water Treatment Process (정수처리공정상 염소소독부산물형성에 미치는 오존의 영향)

  • Seong, Nak Chang;Park, Hyeon Seok;Lee, Seong Sik;Lee, Yong Hui;Lee, Jong Pal;Yun, Tae Gyeong
    • Journal of Environmental Science International
    • /
    • v.13 no.1
    • /
    • pp.55-59
    • /
    • 2004
  • The effect of ozone on the formation and the removal of disinfection byproducts(DBPs) of chlorination process was studied to elucidate the performance of water treatment process. The samples of raw water, prechlorination process, and preozonation process were analyzed quantitatively according to the Standard Methods for the Examination of drinking water. As a result, most of total trihalomethanes(THMs) which were formed in prechlorine treatment process was not removed in the preozonation process. Most of haloacetic acids(HAAs), haloacetonitriles(HANs), and chloral hydrate(CH) was removed in sedimentation and biological activated carbon(BAC) filtration processes. However, DBPs were increased more or less by postchlorine step. In particular, the formation of THMs and HAAs depends on ozone more than chlorine, but, the formation of HANs and CH depends on chlorine more than ozone. The seasonal variation of DBPs concentration for the year needs to be investigated to study the temperature effect because DBPs strongly depend on temperature among various efficient factors.

Removal of residual ozone in drinking water treatment using hydrogen peroxide and sodium thiosulfate (과산화수소와 티오황산나트륨을 이용한 정수처리공정에서의 잔류오존 제거)

  • Kwon, Minhwan;Kim, Seohee;Ahn, Yongtae;Jung, Youmi;Joe, Woo-Hyun;Lee, Kyunghyuk;Kang, Joon-Wun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.4
    • /
    • pp.481-491
    • /
    • 2015
  • The aim of this study was to evaluate the chemical quenching system for residual ozone and to determine the operating condition for the quenching system. Hydrogen peroxide ($H_2O_2$) and sodium thiosulfate ($Na_2S_2O_3$) were investigated as quenching reagents for ozone removal, and the tendency of each chemical was notably different. In the case of $H_2O_2$, the degradation rate of ozone was increased as the concentration of $H_2O_2$ increase, and temperature and pH value have a significant effect on the degradation rate of ozone. On the other hand, the degradation rate of ozone was not affected by the concentration of $Na_2S_2O_3$, temperature and pH value, due to the high reactivity between the ${S_2O_3}^{2-}$ and ozone. This study evaluates the decomposition mechanism of ozone by $H_2O_2$ and $Na_2S_2O_3$ with consideration for the water quality and reaction time. Furthermore, the removal test for the quenching reagents, which can be remained after reaction with ozone, was conducted by GAC process.

Effect of Ozone Treatment for Nakdong River Raw Water - II. Removal of VOCs and Algae in Raw Water by Conducting Batch Test of Ozonation Experiments - (낙동강 상수원수의 오존처리 효과 - II. 회분식 오존처리에 의한 휘발성유기화합물 및 조류제거 효과 -)

  • 임영성;이홍재;이도진;허종수;손보균;조주식
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1267-1274
    • /
    • 2002
  • This study was carried out to evaluate the pollutant removal efficiencies of the advanced drinking water treatment using ozonation process. For raw water, Nakdong River was used. By conducting batch test of ozonation, the following results were obtained. When ozone dosage of $5 mg/{\ell}$ was used, ozone transfer and utilization efficiencies of the ozonation were 94 to 92%, respectively. Removal efficiencies of single VOC compound or mixed VOC compounds in the raw water were 80% to 90% by the ozonation with $2 mg/{\ell}$ dosage and 10 minutes contact time. Removal efficiencies of ABS by the ozonation with $1 mg/{\ell}$, $3 mg/{\ell}$ dosage and 20 minutes contact time were 83% to 96%, respectively. Almost 67% of chlorophyll-a at the concentration of $38.4\mu\textrm{g}/{\ell}$ was removed by ozonation at ozone dosage of $1 mg/{\ell}$ for 20 min. Considering the efficiency of ozone utilization and water treatment, the most effective ozonation could be obtained with high ozone dosage and short contact time.

Numerical Study on the Process Analysis of Ozone Production due to Emissions Reduction over the Seoul Metropolitan Area (수도권 배출량 저감에 따른 오존 발생 과정 분석에 관한 수치연구)

  • Jeong, Yeo-Min;Lee, Soon-Hwan;Lee, Hwa-Woon;Jeon, Won-Bae
    • Journal of Environmental Science International
    • /
    • v.21 no.3
    • /
    • pp.339-349
    • /
    • 2012
  • In order to clarify the impact of emissions reductions on the air quality over Metropolitan area of Korean Peninsula, several numerical experiment and analysis of integrated process rate(IPR) of ozone were carried out. Numerical models used in this study are WRF for the estimate the meteorological elements and CMAQ for assessment of ozone concentration. As result in the sensitive test of VOC/NOx reduction experiments, although VOC reduction tends to induce the different impact on the advection and photochemical reaction rate of ozone in urban area and rural area, the mechanism of ozone appeared to be more sensitive to the reduction of VOC than that of NOx over the metropolitan and its surround area. So the control of VOC emission inventories is an effective means to decrease the ozone concentrations around this area.

A Study on Removal of Color in Dyeing Wastewater by Ozone Oxidation (오존산화에 의한 염색체수의 색도 제거에 관한 연구)

  • 정순형;최준호
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.4
    • /
    • pp.45-51
    • /
    • 2003
  • This study was conducted to remove the color in dyeing wastewater by ozone oxidation process, and the results were summarized as follows ; The 18.3% of BOD and 56.3% TOC were removed as decreasing with pH 1 in dyeing wastewater, containing the polyester reducing process. It showed that terephthalic acid was precipitated at low pH. The color of dyeing wastewater was removed by the first order reaction, and the reaction rate constants at pH 3, 7, 12 were investigated $0.234{\;}min^{-1},{\;}0.215{\;}min^{-1}{\;}and{\;}0.201{\;}min^{-1}$ respectively. It showed that color was more effectively removed with direct reaction of ozone than radical reaction(non-direct reaction). As increasing of the water temperature, the reaction rate constants were increased slightly. It indicated that activity of ozone was improved at high water temperature.

A Study on the Realization of the High Efficiency LCD Photoresist Removal Technology (고효율 LCD 감광막 제거기술 구현 연구)

  • Son, Young-Su;Ham, Sang-Yong;Kim, Byoung-Inn;Lee, Sung-Hwee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.11
    • /
    • pp.977-982
    • /
    • 2007
  • The realization of the photoresist(PR) removal method with vaporized water and ozone gas mixture has been studied for the LCD TFT array manufacturing. The developed PR stripper uses the water boundary layer control method based on the high concentration ozone production technology. We develop the prototype of PR stripper and experiment to find the optimal process parameter condition like as the ozone gas flow/concentration, process reaction time and thin boundary layer formation. As a results, we realize the LCD PR strip rate over the 0.4 ${\mu}m/min$ and this PR removal rate is more than 5 times higher than the conventional immersion type ozonized water process.

A Study on the Ozone Consumption Rate for Drinking Water Treatment Process with Ozone Application (오존의 정수처리 적용을 위한 오존소비인자에 관한 연구)

  • Kang, Tae-Hee;Oh, Byung-Soo;Kwon, Soon-Buhm;Sohn, Byeong-Yong;Kang, Joon-Wun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.663-669
    • /
    • 2005
  • The aim of this study was to investigate the ozone decay pattern for the effective application of ozone in drinking water treatment. In order to measure the ozone decomposition in water, ozone measuring instrument was developed with flow injection analysis (FIA) method. From the result of continuous residual ozone concentration in water, it was confirmed that the ozone decay pattern was divided with instantaneous ozone demand(I.D) and pseudo first-order rate($k_c$) phases, which were influenced by the variation of ozone dose. The empirical model obtained from I.D and $k_c$ values enabled us to predict the residual ozone concentration according to the reaction time, showing the high correlation between model and experimental values. The concentration of OH radical and $R__{ct}$ could be indirectly measured by OH radical probe compound. In both I.D and $k_c$ phases, the production pattern of OH radical could be observed, which was also affected by the variation of ozone dose. Finally, it was confirmed that the ozone consumption rate was varied according to the each drinking water treatment process and seasoning. Therefore, the optimum position and dosage of ozone have to be selected by considering various factors.