• 제목/요약/키워드: Oxygen capacity

검색결과 675건 처리시간 0.026초

로잉 에르고미터 훈련이 남자고등학생의 유산소능력과 근력에 미치는 효과 (Effect of Rowing Ergometer Training on the Aerobic Capacity and Strength of Male High School Students)

  • 김동희;육지민;박혁;임재헌;김석환
    • PNF and Movement
    • /
    • 제16권2호
    • /
    • pp.187-194
    • /
    • 2018
  • Purpose: This study aimed to assess the effect of rowing ergometer training on the aerobic capacity and strength of male high school students over a 12-week period. Methods: Fourteen high school students volunteered to participate in the study. The subjects were divided into two groups: seven subjects in the experimental group and seven in the control group. The subjects in the experimental group performed rowing ergometer training for 75 min per session at three days a week for 12 weeks. The exercise intensity set the maximum heart rate (HRmax) from 40% to 80%. Aerobic capacity was measured by ventilation, cardiac output, and oxygen intake per body weight. Strength was measured by grip strength and back strength before and after training. Results: A significantly increased ventilation (p=0.01), cardiac output (p=0.01), and oxygen intake per body weight (p=0.00) were found in the experimental group. A significantly increased grip strength in the right and left hands (p=0.00, 0.00) and back strength (p=0.04) were observed in the experimental group. Conclusion: Rowing ergometer training can be an effective combined exercise for aerobic capacity and strength of high school students.

부영양화된 북만의 용존산소 수지에 의한 자정능력 (Self-purification Capacity of Eutrophic Buk Bay by DO mass Balance)

  • 최우정;나기환;전영열;박청길
    • 한국수산과학회지
    • /
    • 제24권1호
    • /
    • pp.21-30
    • /
    • 1991
  • 충무시 북서쪽에 위치한 폐쇄성 내만으로 만 외측에는 굴 양식을 하고 있는 북만의 부영양화현상을 구명하고 수질이 최악에 달하는 하계에 일정수준 이상의 용존산소를 유지하기 위한 적정오염부하량 산정을 위해 1988년 1월부터 동년 12월까지 평균 월 4회 조사한 결과를 요약하면 다음과 같다. 전 조사 지점에서 총무기질소는 $0.10{\~}127.41$(평균: 10.71)$\{mu}g-at/l$, 인산 인은 ND-4.29(평균: 0.40) ${\mu}g-at/l$, Chlorophyll-a는 $0.35{\~}132.75$(평균; 11.90) $mg/m^3$이었고, 여름철 동안 평균농도는 각각 $11.06{\mu}g-at/l,\;0.80\mu g/l,\;11.11mg/m^3$로 이미 부영양상태에 있었다. 용존산소는 전 조사지점에서 $0.00{\~}13.42$(평균:6.45)ml/l 였고, 장마가 끝나고 일정한 기간이 경과한 시점인 7월에 전 지점의 저층에서 평균 2.08ml/l의 저산소수괴가 형성되었으며, 8월이후 증감을 되풀이하면서 점차 회복되는 경향을 보였다. 하계에 북만의 시간에 따른 용존산소 변화곡선은 $DO(ml/l)=15.57-1.40{\times}(day)+0.03{\times}(day)^2+0.0001{\times}(day)^3+......$와 같이 나타낼 수 있었고, 이와 같은 산소변화 특성으로부터 구한 산소소비계수 및 공급계수의 고유치는 각각 0.222/day, 0.018ml/l/day로 북만의 용존산소 수지 특성으로 볼 때 하계에 무산소 또는 저산소 상태를 막고 4ml/l이상의 용존산소를 유지하기 위해서는 이 일대의 해역에 수로의 변경이나 산소 공급장치를 이용 0.856ml/l/day 만큼의 산소를 공급하든지 또는 이 량에 해당되는 유입 BOD 부하를 폐수처리장 건설 등을 통하여 감소시켜야 할 것으로 생각된다.

  • PDF

순산소 연소를 위한 초저온 공기분리장치의 최적공정 설계 연구 (A Study on the Optimal Process Design of Cryogenic Air Separation Unit for Oxy-Fuel Combustion)

  • 최형철;문흥만;조정호
    • Korean Chemical Engineering Research
    • /
    • 제56권5호
    • /
    • pp.647-654
    • /
    • 2018
  • 지구 온난화 문제 해결과 온실가스 감축을 위하여 화력발전소를 중심으로 순산소 연소를 통한 $CO_2$ 포집 기술이 개발되었으나, 산소 생산 비용이 높아 경제성이 떨어지는 문제를 가지고 있다. 순산소 연소에 필요한 대량의 산소(>2,000 tpd)를 생산하는 방법은 초저온 공기분리장치(ASU: Air Separation Unit)가 가장 적합한 것으로 알려져 있으나, 대부분 고순도(>99.5%) 산소 생산에 최적화되어 건설되었다. 이런 초저온 공기분리장치에서 순산소 연소에서 사용이 가능한 낮은 순도(90~97%)의 산소를 생산하고 공정을 최적화할 경우, 공정 효율이 높아져 산소 생산 비용 절감이 가능하다. 본 연구에서는 순산소 연소 발전시스템에 산소를 공급할 수 있는 초대형(>2,000 tpd $O_2$) ASU 개발을 위하여 공정 분석 및 비교 평가를 수행하였다. 상용 프로그램인 AspenHysys를 이용하여 산소 순도에 따른 회수율 및 전력소모량을 계산하고 공정의 효율을 평가하였다. 그 결과 ASU를 통해 순산소 연소에 공급되는 산소는 약 95%가 최적이며, 생산 공정 최적화 시 약 12~18%의 전력소모량 절감이 가능한 것을 확인 할 수 있었다.

만성 폐쇄성 폐질환(COPD) 환자에서 운동 시 발생하는 산소 불포화 반응과 관련된 인자 (Factors Related to Exertional Oxygen Desaturation in Patients with COPD)

  • 심상우;조준연;권용식;채진녕;박지혜;이미영;노병학;최원일
    • Tuberculosis and Respiratory Diseases
    • /
    • 제70권6호
    • /
    • pp.498-503
    • /
    • 2011
  • Background: The causes of exertional desaturation in patients with COPD can be multifactorial. We aimed to investigate factors predict exertional desaturation in patients with moderate to severe COPD. Methods: We tested 51 consecutive patients with stable COPD (FEV1/FVC, $40{\pm}13%$ predicted). Patients performed a six minute walk test (6MWT). Pulse oxymetric saturation (SpO2) and pulse rate were recorded. Results: Oxygen desaturation was found in 15 subjects after 6MWT, while 36 subjects were not desaturated. Lung diffusing capacity was significantly lower in desaturation (DS) group ($62{\pm}18%$ predicted) compared with not desaturated (ND) group ($84{\pm}20$, p<0.01). However there was no statistical difference of FEV1/FVC ratio or residual volume between two groups. The pulse rate change was significantly higher in the desaturated compared with the not desaturated group. Six minute walking distance, subjective dyspnea scale, airflow obstruction, and residual volume did not predict exertional oxygen desaturation. Independent factors assessed by multiple logistic regression revealed that a pulse rate increment (odd ratio [OR], 1.19; 95% confidence interval [CI], 1.01~1.40; p=0.02), a decrease in baseline PaO2 (OR, 1.105; 95% CI, 1.003~1.218; p=0.04) and a decrease in lung diffusing capacity (OR, 1.10; 95% CI, 1.01~1.19; p=0.01) were significantly associated with oxygen desaturation. Receiver operator characteristic (ROC) analysis showed that an absolute increment in pulse rate of 16/min gave optimal discrimination between desaturated and not desaturated patients after 6MWT. Conclusion: Pulse rate increment and diffusion capacity can predict exertional oxygen desaturation in stable COPD patients with moderate to severe airflow obstruction.

The beneficial effect of ginsenosides extracted by pulsed electric field against hydrogen peroxide-induced oxidative stress in HEK-293 cells

  • Liu, Di;Zhang, Ting;Chen, Zhifei;Wang, Ying;Ma, Shuang;Liu, Jiyun;Liu, Jingbo
    • Journal of Ginseng Research
    • /
    • 제41권2호
    • /
    • pp.169-179
    • /
    • 2017
  • Background: Ginsenosides are the main pharmacological components of Panax ginseng root, which are thought to be primarily responsible for the suppressing effect on oxidative stress. Methods: 2,2-diphenyl-1-picrylhydrazyl radical scavenging activity and oxygen radical absorption capacity were applied to evaluate the antioxidant activities of the ginsenosides. Human embryonic kidney 293 (HEK-293) cells were incubated with ginsenosides extracted by pulsed electric field (PEF) and solvent cold soak extraction (SCSE) for 24 h and then the injury was induced by $40{\mu}M$ $H_2O_2$. The cell viability and surface morphology of HEK-293 cells were studied using MTS assay and scanning electron microscopy, respectively. Dichloro-dihydro-fluorescein diacetate fluorescent probe assay was used to measure the level of intracellular reactive oxygen species. The intracellular antioxidant activities of ginsenosides were evaluated by cellular antioxidant activity assay in HepG2 cells. Results: The PEF extracts displayed the higher 2,2-diphenyl-1-picrylhydrazyl radical scavenging activity and stronger oxygen radical absorption capacity (with an oxygen radical absorption capacity value of $14.48{\pm}4.04{\mu}M\;TE\;per\;{\mu}g/mL$). The HEK-293 cell model also suggested that the protective effect of PEF extracts was dose-dependently greater than SCSE extracts. Dichloro-dihydro-fluorescein diacetate assay further proved that PEF extracts are more active (8% higher than SCSE extracts) in reducing intracellular reactive oxygen species accumulation. In addition, scanning electron microscopy images showed that the HEK-293 cells, which were treated with PEF extracts, maintained more intact surface morphology. Cellular antioxidant activity values indicated that ginsenosides extracted by PEF had stronger cellular antioxidant activity than SCSE ginsenosides extracts. Conclusion: The present study demonstrated the antioxidative effect of ginsenosides extracted by PEF in vitro. Furthermore, rather than SCSE, PEF may be more useful as an alternative extraction technique for the extraction of ginsenosides with enhanced antioxidant activity.

A Study on the Electrode Characteristics of Hypo-Stoichiometric Zr-based Hydrogen Storage Alloys

  • Lee, Sang-Min;Kim, Seoung-Hoe;Lee, Jai-Young
    • 한국수소및신에너지학회논문집
    • /
    • 제10권4호
    • /
    • pp.197-210
    • /
    • 1999
  • The hydrogen storage performance and electrochemical properties of $Zr_{1-X}Ti_X(Mn_{0.2}V_{0.2}Ni_{0.6})_{1.8}$(X=0.0, 0.2, 0.4, 0.6) alloys are investigated. The relationship between discharge performance and alloy characteristics such as P-C-T characteristics and crystallographic parameters is also discussed. All of these alloys are found to have mainly a C14-type Laves phase structure by X-ray diffraction analysis. As the mole fraction of Ti in the alloy increases, the reversible hydrogen storage capacity decreases while the equilibrium hydrogen pressure of alloy increases. Furthermore, the discharge capacity shows a maxima behavior and the rate-capability is increased, but the cycling durability is rapidly degraded with increasing Ti content in the alloy. In order to analyze the above phenomena, the phase distribution, surface composition, and dissolution amount of alloy constituting elements are examined by S.E.M., A.E.S. and I.C.P. respectively. The decrease of secondary phase amount with increasing Ti content in the alloy explains that the micro-galvanic corrosion by multiphase formation is little related with the degradation of the alloys. The analysis of surface composition shows that the rapid degradation of Ti-substituted Zr base alloy electrode is due to the growth of oxygen penetration layer. After comparing the radii of atoms and ions in the electrolyte, it is clear that the electrode surface becomes more porous, and that is the source of growth of oxygen penetration layer while accelerating the dissolution of alloy constituting elements with increasing Ti content. Consequently, the rapid degradation (fast growth of the oxygen-penetrated layer) with increasing Ti substitution in Zr-based alloy is ascribed to the formation of porous surface oxide through which the oxygen atom and hydroxyl ion with relatively large radius can easily transport into the electrode surface.

  • PDF

인력물자취급의 권장안전하중에 대한 생리학적 고찰 (Physiological viewpoint of the recommended safe weights of load for manual materials handling tasks)

  • 김홍기
    • 대한인간공학회지
    • /
    • 제16권3호
    • /
    • pp.23-36
    • /
    • 1997
  • The objective of this study was to make a comparison of the oxygen consumption rates during the lifting activities and the physiological criteria of the recommended weights of RWL, AL, and MPL by NIOSH Guideline. The physical Work Capacity (PWC) based on the bicycle ergometer was 2562.71ml/min, and the one based on the treadmill was 2874.89ml/min for the college male students of Korea. Lifting activities with four different lifting frequencies(2, 5, 8, 11 lifts/min) for one lifting range from floor to 76cm height were studied. The oxygen consumption rates and the heart rates were measured or recorded while subjects were lifting the weight of RWL, AL, and MPL. The heart rates and the oxygen consumption rates increased as the frequency increased from 2 to lifts/min. However, those slightly decreased at the frequency of 11 lifts/ min. The measured oxygen consumption rates were ranging from 2.3% to 29.6% higher than the physiological criteria 620, 700, and 1000ml/min, respectively, of the RWL, AL, and MPL for all the lifting frequencies (5, 8, 11 lift/min) except 2 lifts/min. It si suggested that the physiological criteria of NIOSH Guideline should be based on the lifting PWC, which can consider the type of lifting activity and the frequency of the task, rather than using the PWC by ergometer or treadmill. The measured oxygen consumption rates were ranging from 13.26% to 40.11% higher than the values estimated using the models by Garg and Kim. From these findings it is suggested that the NIOSH Equation should not be directly applied to Korean without resonable modifications.

  • PDF

Nonstoichimetry (x) of Nuclear Materials UO2+x and $(Ce_yU_{1-y})O_{2+x}$ at High Temperatures as a Function of Oxygen Activity$(a_o_2)$

  • Kang, Sun-Ho;Yoo, Han-Ill;Kim, Han-Soo;Lee, Young-Woo
    • The Korean Journal of Ceramics
    • /
    • 제4권2호
    • /
    • pp.78-82
    • /
    • 1998
  • The oxygen nonstoichiometry (x) of UO$_{2+x}$ and $(Ce_yU_{1-y})O_{2+x}$ (y=0.05, 0.25) has been measured as a function of oxygen activity (a02) at 100$0^{\circ}C$ by a solid state coulometri titration technique. The results for UO$_{2+x}$ are in a good agreement with literature data and the ao2-dependence of the nonstoichimetry has been well explained with (2:2:2) cluster model. The equilibrium oxygen activity of $(Ce_yU_{1-y})O_{2+x}$ increases with Ce-content (y) for given nonstoichiometry (x), which is ascribed to the fact that Ce is present as Ce$^{3+}\; and\; Ce^{4+}$, and, therefore, the addition of Ce reduces the oxidation capacity of UO$_{2+x}$. From the oxygen activity dependence of x in $(Ce_yU_{1-y})O_{2+x}$ the defect structure of $(Ce_yU_{1-y})O_{2+x}$ is discussed.

  • PDF

정수장의 무성방전형 오존발생기 최적활용방안에 관한 연구 (A Study on the Optimal Use of Silent Discharge Type Ozonizer in Purification Plant)

  • 신홍섭;박현미;권영학;송현직;박원주
    • 조명전기설비학회논문지
    • /
    • 제29권3호
    • /
    • pp.54-60
    • /
    • 2015
  • There are 5 purification plants with the adopted advanced water purification treatment process in Korea. Annual operating costs were 8,990 million won including purchase cost of oxygen and power usage charges. We need research to optimize, in the future, when considering the direction of domestic water treatment continues to adopt advanced water treatment process. In this paper, calculate the optimal operating costs by injected the oxygen gas, used power cost. approximately 25% of the operating costs can be reduced when injected the ozone gas is 1.0ppm than 2.0ppm, the necessary amount of oxygen is increased then power is lower. so operating costs are decided according to oxygen costs. On the other hand, high ozone concentration 2.0ppm, the necessary power is increased then amount of oxygen is lower. Therefore, in the case of G purification plant, the controlling factor of the input ozone concentration 2ppm, PID control operation by setting the concentration of over 10Wt% is efficient. The installed capacity is the more little the more better when considering on Ozone injection rate in the process of water treatment.

현장근로자의 생체부하에 관한 인간공학적 연구 (An Ergonomic Study on the Work Loads of Manual Workers)

  • 이상도;우동필
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.174-180
    • /
    • 1999
  • The objective of this study was to investigate the effects of carrying postures and weight of load carried one time on a worker when carrying heavy loads. Six male students participated in this study to perform a manual materials carrying task as subjects. To make comparison of work loads with physical work capacity, maximal oxygen uptake measurement tests were performed with submaximal test. The average oxygen consumption for the tasks of this study was 27.59~31.93% $VO_2$max. The results showed that the weight of load carried one time affects on working heart rate and oxygen consumption($VO_2$). It was found that the workload was significantly lower when handling a 20kg load at a frequency rate of 3times/min than when handling a 40kg load at a frequency rate of 1.5 times/min. There was no difference between carrying postures. It is concluded from the results of this study that the workload can be reduced by controlling conditions of a manual materials handling task.

  • PDF