• Title/Summary/Keyword: Oxygen Line

Search Result 438, Processing Time 0.025 seconds

Application of Oxygen Uptake Rate Measured by a Dynamic Method for Analysis of Related Fermentation Parameters in Cyclosporin A Fermentation:Suspended and Immobilized Cell Cultures

  • Chun, Gie-Taek;Agathos, S.N.
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.6
    • /
    • pp.1055-1060
    • /
    • 2001
  • Experimental data for the on-line estimation of cell concentration and growth rate are presented. For this purpose, we utilized the on-line calculation of the oxygen uptake rate (OUR), which was derived from a liquid phase dynamic mass balance for the oxygen during the active growth phase in cyclosporin A (CyA) fermentation. The cell yield coefficient, based on the oxygen $(Y_{x/o})$for both suspended and immobilized cells of Tolypocladium inflatum, was estimated as $1.9 gDCW/gO_2$ from a very good linear correlation between the cell mass produced and the total oxygen consumed. The calculated yield showed a good agreement with the value of $(Y_{x/o})$ generated from the correlation between the cell growth rate and the oxygen uptake rate. In addition, further experimental data are given, which were also applied to determine the specific oxygen uptake rate of T. inflatum cells during the exponential phase of CyA fermentation. A theoretical basis for the analysis of these fermentation parameters is also provided.

  • PDF

Hydrogen Plasma와 Oxygen Plasma를 이용한 50 nm 텅스텐 패턴의 Oxidation 및 Reduction에 관한 연구

  • Kim, Jong-Gyu;Jo, Seong-Il;Nam, Seok-U;Min, Gyeong-Seok;Kim, Chan-Gyu;Yeom, Geun-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.288-288
    • /
    • 2012
  • The oxidation characteristics of tungsten line pattern during the carbon-based mask layer removal process using oxygen plasmas and the reduction characteristics of the WOx layer formed on the tungsten line surface using hydrogen plasmas have been investigated for sub-50 nm patterning processes. The surface oxidation of tungsten line during the mask layer removal process could be minimized by using a low temperature ($300^{\circ}K$) plasma processing instead of a high temperature plasma processing for the removal of the carbon-based material. Using this technique, the thickness of WOx on the tungsten line could be decreased to 25% of WOx formed by the high temperature processing. The WOx layer could be also completely removed at the low temperature of $300^{\circ}K$ using a hydrogen plasma by supplying bias power to the tungsten substrate to provide an activation energy for the reduction. When this oxidation and reduction technique was applied to actual 40 nm-CD device processing, the complete removal of WOx formed on the sidewall of tungsten line could be observed.

  • PDF

On-line monitoring of microorganism cultivation processes using optical sensing membranes for simultaneous detection of dissolved oxygen and pH (용존산소와 pH의 동시 검출용 광학 센서 막을 이용한 미생물 발효공정의 온라인 모니터링)

  • Kim, Chun-Kwang;Rhee, Jong-II
    • KSBB Journal
    • /
    • v.24 no.1
    • /
    • pp.106-112
    • /
    • 2009
  • An optical sensing membrane has been fabricated to measure the concentration of dissolved oxygen(DO) and pH value simultaneously. It has employed HPTS as a pH sensitive dye and a ruthenium(II) complex as a DO sensitive dye. The sensing membrane has been applied to wells in a 24-well microtiter plate. Using the 24-well microtiter plate the concentrations of dissolved oxygen and pH values have been on-line monitored during the cultivations of E.coli DH5${\alpha}$, B.cereus 318 and P.pastoris X-33. On-line monitoring of DO and pH in microorganism cultivation processes showed good performance of the sensing membrane containing 5 mM HPTS and 2 or 5 mg/mL Rudpp.

An Experimental Study on the Secondary Waveform Analysis according to Measure of Electronic Control Waveform (가솔린엔진의 전자제어 센서파형 측정을 통한 점화2차 파형 분석에 관한 실험적 연구)

  • Yoo, Jong-Sik;Kim, Chul-Soo;Cha, Kyoung-Ok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.1
    • /
    • pp.95-100
    • /
    • 2011
  • The test was done on cars travelling at speeds of 20km/h, 60km/h and 100km/h, the performance testing mode for chassis dynamometer. In this test, the secondary waveform were measured, including those using faulty MAP sensors, oxygen sensors and spark plugs. The results from these measurements and their analysis of secondary waveform can be summarized as follows: 1) The secondary waveform measured from the faulty oxygen sensor showed a lot of noise around peak voltage and in the rising and falling sections during spark line which means that the air fuel mixture was non-homogeneous. 2) The secondary waveform from the faulty MAP sensor showed the worst shape compared to other sensors, including variation of spark line, state of air-fuel mixture and velocity of flame front. 3) The spark line time of secondary waveform using a faulty spark plug displayed the shortest and smallest energy spark line, which means that a misfire occurred.

On-Line Measurement System for the Determination of Chemical Oxygen Demand (화학적 산소 요구량 측정을 위한 On-Line 측정 시스템에 관한 연구)

  • 정형근;차기철
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.203-208
    • /
    • 1998
  • A simple on-line measurement system consisting of a conventional peristaltic pump, a HPLC-type heater, and a flow-through spectrophotometer is introduced for the determination of chemical oxygen demand(CODI. The system was configured such that the reaction mixture in the highly concentrated surffuric acrid medium flowing through the PTFE reaction tubing was heated at 150℃ and the absorbance of dichromate was continuously moutored at 445 m. The same addation principle as in the standard procedure was employed akcept the use of CoSO4 as a new effective catalyst. To test the system, potassium hydrogen phthalate was selected as a COD standard material. With suitably optimized reaction condition, the applicable concentration range depends on the concentration of potassium dichromate in the oxidizing reagent. With 2.0×10-3 M and 5.0×10-4M dichromate, the linear dynamic range was observed up to 400 ppm and 100 ppm, respectively. The standards in the Unear ranges were shown to be completely oxidized, which was confirmed with sodium oxalate or Mohr's salt. In all cases, the typical reproduclbility for betweenruns was 2% or less. The proposed measurement system provides the valuable in- formation for the further development of automated analysis system based on the present standard procedure.

  • PDF

Simultaneous measurement of oxygen permeability by using of multi-functional oxygen electrode (다기능 산소전극에 의한 산소투과특성 동시측정)

  • 이동희;정진휘;유형풍;김태진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.532-535
    • /
    • 2000
  • We have fabricated a sensor system for on-line monitoring the oxygen permeability and diffusivity of six different polymer films using the miniaturized 6 cathode(Ag)-single anode(Ag/AgCl) type hexagonal oxygen electrode. This system consists of multiple input front-end electronics, signal conditioning circuit using the embedded microcontroller 80C196KC, PC interface circuit and PC with the OS for microcontroller and the operating program for this system. The digital low-[ass filter was programmed and the simulated filter characteristics were enough to eliminate the noise from sensor signal. According to the experimental results, the linearity coefficients of the output voltage to oxygen partial pressure for each sensor electrode of six cathode type oxygen sensor are 0.998, 0.997, 0.998, 0.997, 0.997, 0.997 respectively, and the response times are all within 4 minutes.

  • PDF

Effect of Vitamin E Against the Cytotoxicity of Reactive Oxygen Species on Vascular Endothelial Cells

  • Kwon O-Yu;Park Seung-Taeck
    • Biomedical Science Letters
    • /
    • v.12 no.3
    • /
    • pp.255-259
    • /
    • 2006
  • Reactive oxygen species (ROS) is one of the main pathological factors in endothelial disorder. For example, an atherosclerosis is induced by the dysfunction of vascular endothelial cells. The dysfunction of vascular endothelial cells cascades to secrete intercellular adhesion molecule (ICAM)-l substance by ROS. Therefore, The ROS is regraded as an important factor of the injury of vascular endothelial cells and inducement of atherosclerosis. Oxygen radical scavengers playa key role to prevention of many diseases mediated by oxidative stress of ROS. In this study, the toxic effect of ROS on vascular endothelial cells and the effect of antioxidant, vitamin E on bovine pulmonary vascular endothelial cell line (BPVEC) treated with hydrogen peroxide were examined by the colorimetric assay. ROS decreased remarkably cell viability according to the dose- and time-dependent manners. In protective effect of vitamin E on BPVEC treated with hydrogen peroxide, vitamin E increased remarkably cell viability compared with control after BPVEC were treated with $15{\mu}M$ hydrogen peroxide for 6 hours. From these results, it is suggested that ROS has cytotoxicity on cultured BPVEC and oxygen radical scavenger such as vitamin E is very effective in prevention of oxidative stress-induced cytotoxicity.

  • PDF

Continuous On-line Estimation of Cell Growth and Substrate Consumption Using a Computer-coupled Mass Spectrometer (Computer-coupled Mass Sepctrometer를 이용한 세포증식과 기질소모의 연속적 On-line추정)

  • 남수완;김정희
    • KSBB Journal
    • /
    • v.4 no.2
    • /
    • pp.118-122
    • /
    • 1989
  • From the on-line mass spectrometric analyese of the exhaust gaseous composition of fermentor and the material balance equations for oxygen and carbon dioxide, oxygen uptake rate (OUR) and carbon dioxide evolution rate (CER) were calculate using a personal computer (IBM PC-AT) interfaced to a quadrupole mass spectromter. The calculate OUR and CER were used for the indirect estimation of cell and substrate concentrations during the batch culture of Candida utilis. For the estimation of sustrate concentration, the yield model of Pirt was applied. It was found that the cell and substrate (glucose) concentration could be ssatisfactorily estimataed and the results showed the more accurate estimations of both fermentation state variables when OUR data were used than CER data.

  • PDF

Performance Test and Calculation of Recirculation Line in Propellant Feeding System (기체공급계 재순환배관의 성능시험 및 계산)

  • Kwon, Oh-Sung;Cho, Nam-Kyung;Chung, Yong-Gahp;Han, Sang-Yeop;Kim, Young-Mog
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.2
    • /
    • pp.9-17
    • /
    • 2007
  • The performance test of recirculation line in propellant feeding system was carried out. Liquid oxygen was used as cryogenic propellant and helium was used as recirculation promotion gas. Tests were done in cases at atmospheric pressure and at pressure of 4 barg in the ullage space of propellant tank. Liquid oxygen recirculation flowrate with helium injection flowrate and temperature distribution along the line were measured. There was appropriate helium injection flowrate for gas-lift recirculation system. Test data were used to make calculation program by test data correlation method. In this paper the procedure of calculation was presented and the results were compared to test data.

A measurement of the line spread function of computed radiography (Computed radiograhy의 line spread funciton(LSF) 측정)

  • Kim, Chang-Bok;Kim, Young-Keun;Kim, Keon-Jung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.124-130
    • /
    • 2003
  • Zinc Oxide(ZnO) thin films on Si (100) substrate were deposited by RF magnetron sputter with changing sputtering conditions such as argon/oxygen gas ratios, RF power, and substrate temperature, chamber pressure and target-substrate distance. To analyze a crystallographic properties of the films, $\theta/2\theta$ mode X-ray diffraction, SEM, and AFM analyses. C-axis preferred orientation, resistivity. and surface roughness highly depended on $Ar/O_2$ gas ratios. The resistivity of ZnO thin films rapidly increased with increasing oxygen ratio and the resistivity value of $9{\times}10^7{\Omega}cm$ was obtained at a working pressure of 10 mTorr with $Ar/O_2$=50/50. The surface roughness was also improved with increasing oxygen ratio and the ZnO films deposited with $Ar/O_2$=50/50 showed the excellent roughness value of $28.7{\AA}$.

  • PDF