• Title/Summary/Keyword: Oxidation resistant

Search Result 123, Processing Time 0.03 seconds

High Temperature Oxidation and Sulfidation of Ni-15at.%W Coatings

  • Kim Chanwou;You Teayoul;Shapovalov Yuriy;Ko Jaehwang;Lee Dongbok;Lee Kyuhwan;Chang Doyon;Kim Dongsoo;Kwon Sikchol
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • Ni-15at.% W coatings with film thicknesses of 20-40 ㎛ were electroplated on a steel substrate, and their oxidation behavior was investigated at 700 and 800℃ in air. For comparison, a pure Ni coating and a bulk Ni were also oxidized. The Ni-15at.%W coating displayed the worst oxidation resistance, due to the formation of less-protective NiO, Fe₂O₃, NiFe₂O₄ and NiWO₄. The corrosion behavior Ni-15at.%W coatings electroplated on a steel substrate was similarly investigated at 700 and 800℃ in the Ar-l%SO₂ atmosphere. For comparison, the uncoated steel substrate was also corrosion-tested in the Ar-l %SO₂ atmosphere. Severe scale spallation and the internal corrosion of the steel that occurred in the uncoated substrate were not observed in the coated specimen. However, it seemed that the Ni-15at.%W coating cannot be a potential candidate as a sulfidation-resistant coating, due to the formation of less-protective NiO, NiS, WO₃ and NiWO₄.

Biocompatibility of STS304, 316 acupuncture needle (침의 재료인 스테인리스강 STS304 및 STS316의 생체적합성에 대한 고찰)

  • Hwang, Eui-Hyoung;Koo, Sung-Tae;Lee, In-Hwan;Lee, Min-Ho;Jang, In-Soo
    • Korean Journal of Acupuncture
    • /
    • v.24 no.1
    • /
    • pp.59-63
    • /
    • 2007
  • Objectives : To discuss the biocompatibility of stainless steel for using acupuncture needles. Results and Conclusions : It is widely assumed that stainless steel is one of the good corrosion-resistant materials and is safe for human body, Most of metal acupuncture needles are made of STS304 and STS316 in light of human body safety: STS304 in more differences between STS304 and STS316 in light of human body safety: STS304 is more vulnerable to oxidation than STS316. A variety of literature survey showed that although STS316 is more corrosion-resistant than STS304 there is no evidence supporting the hypothesis that STS304 has the potential danger to human body, Further study would be necessary to draw more decisive conclusion.

  • PDF

Development of C/SiC Composite Parts for Rocket Propulsion (로켓 추진기관용 C/SiC 내열부품 개발)

  • Kim, Yunchul;Seo, Sangkyu
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.2
    • /
    • pp.68-77
    • /
    • 2019
  • C/SiC composites were developed by a liquid silicon infiltration(LSI) method for use as heat-resistant parts of solid and liquid rocket propulsion engines. The heat resistance characteristics according to the composition ratio (carbon / silicon / silicon carbide) were evaluated by specimen test through arc plasma, supersonic torch test. An ablation equation for oxidation reactions was presented. Through the combustion test it was verified that various parts such as nozzle insert, exit cone and combustion chamber heat resistant parts for rocket propulsion can be manufactured and proved high ablation performance and thermal structure performance.

Membrane Based Removal of Antibiotics from Wastewater: A Review (폐수중 항생제의 막기반 제거에 관한 연구: 검토)

  • Ryoo Wanki;Rajkumar Patel
    • Membrane Journal
    • /
    • v.34 no.2
    • /
    • pp.96-104
    • /
    • 2024
  • Antibiotics is one of the emerging pollutants found in various water sources as well as wastewater due to its excessive use. Different techniques are available for treating antibiotics contaminants in water such as advanced oxidation process and biological treatment etc. These two processes are ineffective, and the generation of side products makes this process more complicated. Membrane technology is another alternative for the removal of contaminants. To improve the removal of antibiotics and their resistant gene, membrane bioreactors are modified with NaClO and carbon materials. The generation of abundant reactive species is active against the antibiotic's resistant genes.

A Spectrophotometric Assay for Cytochrome P450 Monooxygenase Activity

  • Lee, Sung-Eun;Choi, Won-Sik;Park, Byeoung-Soo;Lee, Byung-Ho
    • Applied Biological Chemistry
    • /
    • v.41 no.4
    • /
    • pp.213-217
    • /
    • 1998
  • An assay for cytochrome P450 monooxygenase activity by determination of the products of organophosphate oxidation via inhibition of acetylcholinesterase was described. Extracts from strains of Oryzaephilus surinamensis selected for resistance to chlorpyrifos-methyl (QVOS 102), fenitrothion (VOS F) and malathion (VOS 3), and a standard susceptible strain VOS 48, were incubated with an organophosphate in the presence of a NADPH-generating system and acetylcholinesterase. The degree of inhibition of the acetylchoinesterase activity was converted to manooxygenase activity using standard curves for the inhibition of acetylcholiesterase by chlorpyrifos-methyl-oxon, fenitrooxon and malaoxan. Activity was detectable in VOS 48 and was present at different increased levels with the different organophosphates in the three resistant strains, suggesting that different forms of P450 might be involved in organophosphate oxidation in these insects. The assays were carried out using crude insect homogenates and much smaller samples of insect material than the standard aldrin to dieldrin assay. It should be possible to use the method for determination of monooxygenase activity in single insert.

  • PDF

High-temperature Corrosion of CrAlSiN Films in Ar/1%SO2 Gas

  • Lee, Dong Bok;Xiao, Xiao;Hahn, Junhee;Son, Sewon;Yuke, Shi
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.5
    • /
    • pp.246-250
    • /
    • 2019
  • Nano-multilayered $Cr_{25.2}Al_{19.5}Si_{4.7}N_{50.5}$ films were deposited on the steel substrate by cathodic arc plasma deposition. They were corroded at $900^{\circ}C$ in $Ar/1%SO_2$ gas in order to study their corrosion behavior in sulfidizing/oxidizing environments. Despite the presence of sulfur in the gaseous environment, the corrosion was governed by oxidation, leading to formation of protective oxides such as $Cr_2O_3$ and ${\alpha}-Al_2O_3$, where Si was dissolved. Iron diffused outward from the substrate to the film surface, and oxidized to $Fe_2O_3$ and $Fe_3O_4$. The films were corrosion-resistant up to 150 h owing to the formation of thin ($Cr_2O_3$ and/or ${\alpha}-Al_2O_3$)-rich oxide layers. However, they failed when corroded at $900^{\circ}C$ for 300 h, resulting in the formation of layered oxide scales due to not only outward diffusion of Cr, Al, Si, Fe and N, but also inward movement of sulfur and oxygen.

Characterization of Lactobacillus fermentum PL9988 Isolated from Healthy Elderly Korean in a Longevity Village

  • Park, Jong-Su;Shin, Eunju;Hong, Hyunjin;Shin, Hyun-Jung;Cho, Young-Hoon;Ahn, Ki-Hyun;Paek, Kyungsoo;Lee, Yeonhee
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.9
    • /
    • pp.1510-1518
    • /
    • 2015
  • In this work, we wanted to develop a probiotic from famous longevity villages in Korea. We visited eight longevity villages in Korea to collect fecal samples from healthy adults who were aged above 80 years and had regular bowel movements, and isolated lactic-acid-producing bacteria from the samples. Isolated colonies that appeared on MRS agar containing bromophenol blue were identified by means of 16S rRNA sequencing, and 102 of the isolates were identified as lactic-acid-producing bacteria (18 species). Lactobacillus fermentum was the most frequently found species. Eight isolates were selected on the basis of their ability to inhibit the growth of six intestinal pathogens (Escherichia coli O157:H7, Salmonella enterica subsp. enterica Typhimurium, Salmonella enterica subsp. enterica Enteritidis, Enterococcus faecalis, Staphylococcus aureus, and Listeria monocytogenes) and their susceptibility to 15 antimicrobial agents. Among these eight isolates, four Lactobacillus fermentum isolates were found not to produce any harmful enzymes or metabolites. Among them, Lactobacillus fermentum isolate no. 24 showed the strongest binding to intestinal epithelial cells, the highest immune-enhancing activity, anti-inflammation activity, and anti-oxidation activity as well as the highest survival rates in the presence of artificial gastric juice and bile solution. This isolate, designated Lactobacillus fermentum PL9988, has all the characteristics for a good probiotic.

Hot Corrosion Properties of Heat Resistant Chrome Steels (내열강의 고온부식특성에 대한 크롬함량의 영향)

  • Lee, Han-sang;Jung, Jine-sung;Yoo, Keun-bong;Kim, Eui-hyun
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.4
    • /
    • pp.277-288
    • /
    • 2010
  • The hot corrosion properties of heat-resistant steels were investigated in an oxidation atmosphere including artificial ash and sulfur dioxide. The heat-resistant steels of T22, T92, T122, T347HFG, Super304H and HR3C were evaluated at 620, 670 and $720^{\circ}C$ for 400 hours. The relationship between the corrosion rate and the temperature followed a bell-shaped curve with a peak rate at around $670^{\circ}C$. The corrosion rates showed a decreasing tendency as the chrome contents of these steels increased from 2.15 wt.% to 24.5 wt.%, and austenitic steels had a lower corrosion rate than ferritic steels. Sulfidation by $SO_2$ as well as molten salt corrosion also had an effect on the total corrosion rate, especially showing an increase in the corrosion rate in ferritic steels. Regardless of the chrome content in the steels and irrespective of the test temperature, the corrosion scale was composed of an outer oxide and an artificial ash mixed layer, a middle oxide layer and inner sulfide, and a mixed oxide layer. As the chrome content increased, the proportion of chrome oxide in the corrosion scale increased. Before spalling of the corrosion scale, voids and cracks were initiated in the sulfide and the mixed oxide layer or at the interface with the substrate.

The Lubricant Effect of Oxidation and Wear Products of HVOF Co-alloy T800 Powder Coating

  • Cho, Tong Yul;Yoon, Jae Hong;Kim, Kil Su;Song, Ki Oh;Youn, Suk Jo;Chun, Hui Gon;Hwang, Soon Young
    • Corrosion Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.159-163
    • /
    • 2007
  • Micron size Co-alloy 800 (T800) powder is coated on the high temperature, oxidation and corrosion resistant super alloy Inconel 718 substrate by the optimal high velocity oxy-fuel (HVOF) thermal spray coating process developed by this laboratory. For the study of durability improvement of high speed spindle operating without lubricants, friction and sliding wear behaviors of the coatings are investigated both at room and at an elevated temperature of $1000^{\circ}F(538^{\circ}C)$. Friction coefficients, wear traces and wear debris of coatings are drastically reduced compared to those of non-coated surface of Inconel 718 substrate both at room temperature and at $538^{\circ}C$. Friction coefficients and wear traces of both coated and non-coated surfaces are drastically reduced at higher temperature of $538^{\circ}C$ compared with those at room temperature. At high temperature, the brittle oxides such as CoO, $Co_{3}O_{4}$, $MoO_2$ and $MoO_3$ are formed rapidly on the sliding surfaces, and the brittle oxide phases are easily attrited by reciprocating slides at high temperature through oxidation and abrasive wear mechanisms. The brittle solid oxide particles, softens, melts and partial-melts play roles as solid and liquid lubricants reducing friction coefficient and wear. These show that the coating is highly recommendable for the durability improvement coating on the machine component surfaces vulnerable to frictional heat and wear.

Oxidized Biotite in the Weathering Profile of Andong Cranite (안동화강암의 풍화단면에서 산출되는 산화흑운모)

  • 정기영;김혜빈
    • Journal of the Mineralogical Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.183-194
    • /
    • 2002
  • Biotite and its weathering Products in the weathering Profile of Andong granite were examined using X-ray diffraction, chemical analysis, and electron microscopy. Major weathering product of biotite was oxidized biotite, which is decomposed into kaolinite in the upper part. Discrete vermiculite or hydrobiotite was not detected although minor vermiculite (5%) was randomly interstratified with oxidized biotite. Excess positive charge induced by iron oxidation was balanced by release of Fe (16%) and Mg (12%) from octahedral site and K (13%) from interlayer site. After slight chemical and structural modification induced by iron oxidation, oxidized biotite persists through the weathering profiles with partial decomposition in the upper part of the profile. Formation environments and dissolution experiments of oxidized biotite highly resistant to weathering are required to understand the elemental behavior in the surface environments on the biotite-bearing bedrocks.