• Title/Summary/Keyword: Oxidation efficiency

Search Result 952, Processing Time 0.029 seconds

Study on the Photocatalytic Characteristic and Activity of Cu2O/TiO2 Heterojunction Prepared by Ultrasonification (초음파 합성 적용 Cu2O/TiO2 이종접합 소재의 특성 및 활성도 평가에 관한 연구)

  • Choi, Jeong-Hak;Lee, Joon Yeob
    • Journal of Environmental Science International
    • /
    • v.29 no.12
    • /
    • pp.1213-1222
    • /
    • 2020
  • In the current study, a Cu2O/TiO2 photoinduced nanocomposite materials prepared by ultrasonification method was evaluated the photocatalytic oxidation efficiency of volatile organic compounds (BTEX) under visible-light irradiation. The results of XRD confirmed the successful preparation of photoinduced nanocomposite materials. However, diffraction peaks belonging to TiO2 were not confirmed for the Cu2O/TiO2. The possible reason for the absence of Cu2O peak is their low content and small particle size. The result of uv-vis spectra exhibited that the fabricated Cu2O/TiO2 can be activated under visible light irradiation. The FE-SEM/EDS and TEM showed the formation of synthesized nanocomposites and componential analysis in the undoped TiO2 and Cu2O/TiO2. The photocatalytic oxidation efficiencies of benzene, toluene, ethylbenzene, and o-xylene with Cu2O/TiO2 were higher than undoped TiO2. According to light sources, the average oxidation efficiencies for BTEX by Cu2OT-0.5 were exhibited in the orer of 8 W day light > violet LEDs > white LEDs. However, the photocatalytic oxidation efficiencies normalized to supplied electric power were calculated to be in the following order of violet LEDs > white LEDs > 8 W day light, indicating that the LEDs could be a much more energy efficient light source for the photo-oxidation of gaseous BTEX using Cu2O/TiO2.

Performance Evaluation of Diesel Oxidation Catalysts for Diesel Vehicles (디젤자동차용 산화촉매의 성능 평가)

  • 최병철;박희주;정명근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.59-64
    • /
    • 2003
  • Recently, as people pay attention to the environmental pollution, the emissions of diesel engine have been a serious problem. We carried out the performance evaluation test of Diesel Oxidation Catalysts (DOC) for HSDI diesel engine equipped vehicles. The DOC, basically coated with Pt catalyst, was manufactured with various washcoat materials. It was found that CO conversion efficiency depends on temperature, but THC conversion efficiency is dominated by temperature and space velocity. The THC and CO conversion efficiencies of aged catalysts were increased with additions of $ZrO_2$ and zeolite B in the washcoat. We found that DOC performance changes with coating techniques, even through it has same washcoat materials. The DOC coated by high temperature washcoat coating technology showed good conversion efficiency than low temperature washcoat coated DOC.

Degradation of Trichloroethylene in Aqueous Phase by Electrochemical Ferrate(VI) (전기화학적 합성 Ferrate(VI)를 이용한 수중 Trichloroethylene 분해특성 연구)

  • Nam, Ju-Hee;Kwon, Byung-Hyuk;Kim, Il-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.453-461
    • /
    • 2012
  • The degradation characteristics of TCE by Ferrate(VI) oxidation have been studied. Ferrate(VI) were prepared by electrochemical method. The degradation efficiency of TCE in aqueous solution was investigated at various pH values, Ferrate(VI) doses and aqueous solution temperature values. GC-ECD was used to analyze TCE. TCE was degraded rapidly by ferrate(VI) in aqueous solution, Also, the experimental results showed that TCE removal efficiency increased with the increase of Ferrate(VI) doses. The effect of pH was investigated and the maximum degradation efficiency was obtained at pH 7. And intermediate products were identified by GC-MS techniques. Ethyl Chloride, Dichloroethylene, Chloroform, 1,1-dichloropropene, Trichloroacetic acid and Trichloroethane were identified as a reaction intermediate, and $Cl^-$ was identified as an end product.

Degradation of Benzothiophene by Potassium Ferrate(VI) (Potassium Ferrate(VI)를 이용한 Benzothiophene 분해특성 연구)

  • Lee, Kwon-Chul;Kim, Il-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.643-649
    • /
    • 2011
  • Degradation of benzothiophene(BT) in the aqueous phase by potassium ferrate(VI) was investigated. Potassium ferrate(VI) was prepared by the wet oxidation method. The degradation efficiency of BT was measured at various values of pH, ferrate(VI) dosage and initial concentration of BT. BT was degraded rapidly within 30 seconds by ferrate(VI). While the highest degradation efficiency was achieved at pH 5, the lowest degradation efficiency was achieved at pH 9. Also, the initial rate constant of BT increased with decreasing of the BT initial concentration. In addition, the intermediate analysis for the reaction of BT and ferrate(VI) has been conducted using GC-MS. Benzene, styrene, benzaldehyde, formaldehyde, benzoic acid, formic acid, and acetic acid were identified as reaction intermediates, and ${SO_4}^{2-}$ was identified as an end product.

Evaluation of electrical energy consumption in UV/H2O2 advanced oxidation process for simultaneous removal of NO and SO2

  • Shahrestani, Masoumeh Moheb;Rahimi, Amir
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.389-396
    • /
    • 2019
  • The electrical energy consumption (EEC) in removal of NO by a $UV/H_2O_2$ oxidation process was introduced and related to removal efficiency of this gas. The absorption-reaction of NO was conducted in a bubble column reactor in the presence of $SO_2$. The variation in NO removal efficiency was investigated for various process parameters including NO and $SO_2$ inlet concentrations, initial concentration of $H_2O_2$ solution and gas flow rate. EEC values were obtained in these different conditions. The removal efficiency was increased from about 22% to 54.7% when $H_2O_2$ concentration increased from 0.1 to 1.5 M, while EEC decreased by about 70%. However, further increase in $H_2O_2$ concentration, from 1.5 to 2, had no significant effect on NO absorption and EEC. An increase in NO inlet concentration, from 200 to 500 ppm, decreased its removal efficiency by about 10%. However, EEC increased from $2.9{\times}10^{-2}$ to $3.9{\times}10^{-2}kWh/m^3$. Results also revealed that the presence of $SO_2$ had negative effect on NO removal percentage and EEC values. Some experiments were conducted to investigate the effect of $H_2O_2$ solution pH. The changing of pH of oxidation-absorption medium in the ranges between 3 to 10, had positive and negative effects on removal efficiency depending on pH value.

Surface Passivation of Tunnel Silicon Oxide Grown by Ozone Oxidation (오존 산화에 의해 형성된 터널 실리콘 산화막의 표면 패시베이션)

  • Baek, Jong Hoon;Cho, Young Joon;Chang, Hyo Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.5
    • /
    • pp.341-344
    • /
    • 2018
  • In order to achieve a high efficiency for the silicon solar cell, a passivation characteristic that minimizes the electrical loss at a silicon interface is required. In this paper, we evaluated the applicability of the oxide film formed by ozone for the tunnel silicon oxide film. To this end, we fabricated the silicon oxide film by changing the condition of ozone oxidation and compared the characteristics with the oxide film formed by the existing nitric acid solution. The ozone oxidation was formed in the temperature range of $300{\sim}500^{\circ}C$ at an ozone concentration of 17.5 wt%, and the passivation characteristics were compared. Compared to the silicon oxide film formed by nitric acid oxidation, implied open circuit voltage (iVoc) was improved by ~20 mV in the ozone oxidation and the ozone oxidation after the nitric acid pretreatment was improved by ~30 mV.

Chromaticity removal by chlorine and ozone oxidation in water treatment (상수처리에서 염소 및 오존산화를 이용한 색도제거)

  • Lee, Jeonghoon;Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.273-279
    • /
    • 2017
  • Optimal processes to remove chromaticity at E water treatment plant(WTP) mainly caused by algae of E lake in Jeju island were investigated based on lab-tests of chlorine and ozone oxidation. 42.9% of chromaticity of filtered water was removed by chlorine oxidation under pH 7.0~8.0, dose of 1.0 mg/L with contact time of 30~60 min. On the other hand, chromaticity removal was 71.4% when post-ozone dose of 0.9~1.9 mg/L and pH 9.0, while it was increased to 86.7% under post-ozone dose of 3.1~7.3 mg/L and pH 9.0. However, there was no significant chromaticity removal efficiency increase when ozone doses were higher than 5.0 mg/L regardless of feeding point(i.e., pre-ozonation and post-ozonation) and pHs(i.e., 7.0 and 9.0.) under the experimental conditions. Based on the results, chlorine oxidation using existing chlorination facilities at the WTP is recommended for lower chromaticity while ozone oxidation is recommended for higher chromaticity by installing new ozone feeding facilities.

A Study of Simultaneous Reaction for NOx, Soot and Thermal Shock according to Pt Catalyst's Supports (담체에 따른 Pt 촉매의 NOx, soot 동시 반응특성과 열충격에 관한 연구)

  • Kim, Sung Su;Park, Kwang Hee;Bae, Se Hyun;Hong, Sung Chang
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.437-442
    • /
    • 2009
  • In this work, thermal shock and simultaneous removal reaction for NOx, soot over Pt catalysts using $TiO_2$, $Al_2O_3$ as support were studied. The catalytic reaction test for NOx and soot were also performed independently and simultaneously, as a result, it showed different NOx removal efficiency and soot oxidation rate according to support and phase, and the onset temperature of soot oxidation has correlation to NOx removal efficiency for the catalyst. The onset temperature of soot oxidation shifted to lower temperature by generated $NO_2$ at the simultaneous reaction for NOx and soot. Also Pt/$TiO_2$ catalyst is more affected than Pt/$Al_2O_3$ on NOx removal efficiency caused by thermal shock while Pt sintering effect induced to reduce the performance on soot oxidation rate for all catalysts.

Studies of Methane Oxidation Catalyst on H2-CNG Mixed Fuel Vehicles (수소-CNG 혼소연료 차량에서의 메탄 저감을 위한 산화촉매에 관한 연구)

  • Lee, Ung-Jae;Shim, Kyung-Sil;Yang, Jaechun;Kim, Tae-Min
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.22-27
    • /
    • 2013
  • HCNG engine is performed as a future engine because of high combustion efficiency and eco-friendly property, and is predicted to a brdge of hydrogen vehicles. As EURO-6 regulagion is due to be applied in 2014, consolidated regulations of methane gas that is exhausted from CNG and HCNG vehicles will come into effect. In this studies, methane oxidation catalyst is introduced to remove methane gas from HCNG emissions. Methane oxidation efficiency on catalyst was studied when it is driven long time. And characterization like metal dispersion, surface area was performed to investigate the correlation of catalyst efficiency and characteristics.

Enhancement of Biodegradation Rate of Petroleum Hydrocarbons-contaminated Soil with Addition of Organic Composite Nutrients and a Chemical Oxidation (유기성 영양분 첨가 및 화학적 산화 연계를 통한 유류오염 토양의 생물학적 정화효율 향상에 관한 연구)

  • Kim, Guk-Jin;Oh, Seung-Taek;Lee, Cheol-Hyo;Seo, Sang-Ki;Kang, Chang-Hwan;Chang, Youn-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.3
    • /
    • pp.59-66
    • /
    • 2008
  • A biological study was conducted to evaluate the enhancement of landfarming of soil contaminated with petroleum hydrocarbon (TPH) applying organic composite nutrients and a chemical oxidation during bioremediation. The target value of soil TPH after treatment was 500 mg/kg TPH. Addition of an organic compost and liquid swine manure for the removal of soil THP showed higher efficiency as 84.4% and 92.2% respectively than inorganic nutrients of 80.2%. In addition to the removal of non-biodegradable portion of residual hydrocarbons in soil, a chemical oxidation was applied during tailing period of the biological remediation, which showed high remediation efficiency as 98.1% compared with single bioremediation efficiency of 84.7%.