• Title/Summary/Keyword: Overvoltage Protection

Search Result 67, Processing Time 0.029 seconds

A Study on the Protective Coordination of Generator Overexcitation and Overvoltage Relay (발전기 과여자 및 과전압 계전기 보호협조에 관한 연구)

  • Park, Ji-Kyung;Kim, Kwnag-Hyun;Kim, Chul-Hwan;Lyu, Young-Sik;Yang, Jeong-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1187-1194
    • /
    • 2017
  • After North American wide area black out on August 14, 2003, various studies have been conducted to find out the reason of the disaster. One of main reasons was misoperation of generator protection system. Since then, protective coordination between generator protection system and excitation system controls has been hot issue among electrical engineers. Among various generator protection relays, in this paper, we focused on generator overvoltage and overexcitation relay, which protect the over-flux condition of the generator. Thus, at first, we modeled the generator overvoltage, overexcitation relay and detailed power system including excitation system, governor and etc., based on actual field data. And then, we reviewed the protective coordination of generator overvoltage and overexcitation relay using electromagnetic transient program. In addition, we discussed the protective coordination method for redundant protection relays in both automatic voltage regulator and generator side.

A Stuty of Protection Circuit for Discharge Lamp Ballast (방전등 안정기의 보호회로 기술 현황)

  • Han, Soo-Bin;Park, Suck-In;Song, Eu-Gine;Jeoung, Hak-Guen;Jung, Bong-Man
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.133-135
    • /
    • 2008
  • In a design of ballast for discharge lamp, various kind of protection circuit are essential for safe operation. In this paper, overvoltage and current detection, no-load detection, lamp-fault detection, end of lamp detection for protection are introduced. Individual circuit operation and their function are described with the base that all circuit form is similar with overvoltage protection circuit.

  • PDF

Analysis of Protection Circuits of Overcurent and Overvoltage on Transmission Line Induced by External Electromagnetic Pulse (외부 전자파 펄스에 의해 전송선로에 유기되는 과전류 및 과전압 보호회로의 해석)

  • 하헌태;김세윤;이경재;오명환
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.1
    • /
    • pp.8-14
    • /
    • 1991
  • A new algorithm for calculation of overcurrent and overvoltage at load for parallel two-wire transmission line with nonlinear protection circuits induced by and external electromagnetic pulse is suggested. The rigorous solution is obtained for a particular type of the incident waveform and protection circuit. The validity of our algorithm is checked by comparing numerical results to the analytic solution in the particular case.

  • PDF

Evaluation of the Impacts of SPD Connecting Lead Lengths and SPD Protection Distance to the Apparatus in Apartments (공동주택에서 SPD의 리드선 길이 및 보호거리에 대한 영향 평가)

  • Lee, Ki-Hong;Kang, Moo-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.94-101
    • /
    • 2011
  • The proper installation of SPD and the evaluation of the SPD protection distance are basic steps for the effective protection measures of apparatus against surges within a structure. A novel method for installing SPD on the conventional distribution board without any modification was proposed and it's effectiveness was evaluated by experiments. Also, the transient overvoltage occurred across the power line from the SPD to the load was simulated with EMTP software to see how different the protection distances affecting the magnitude of the transient overvoltage. As evaluated, the effective protection method of apparatus against surges, coordinated SPD protection system is suggested as a proper measure to protect within the apartment.

Judgement of the need for Over-Voltage Control of the Low-Voltage Electrical Installations (저압 전기설비의 과전압 억제 필요성 판단)

  • Lee, Ju-Cheol;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.91-96
    • /
    • 2015
  • There are provision for risk analysis in IEC standards. It is to determine the need for installation of a surge protection device (SPD) in order to protect the low-voltage electrical installations from overvoltages caused by atmospheric phenomena and the like. However, scattered many related standards, the lack of details are not easy to apply it in the field. We investigated the relevant domestic and international standards for applies to the international standards in domestic. And we proposed the flow chart for determining the need for protection of the low-voltage electrical installations from overvoltage due to atmospheric phenomena and it set the appling target facility.

Applicability of Messenger Wire for Purpose of Lightning Protection

  • Seo, Hun Chul;Han, Joon;Choi, Sun Kyu;Lee, Byung Sung;Rhee, Sang Bong;Kim, Chul Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.167-174
    • /
    • 2016
  • The Korean distribution line currently consists of overhead ground wires (OHGW), overhead distribution lines, neutral wires (NW), and messenger wires (MW). The MW is installed under the NW. The lightning protection system in Korea is focused on OHGW and lightning arrester and the MW are not considered. Therefore, this paper proposes the applicability of MW for purpose of lightning protection. For this, we analyzed the effects of lightning overvoltage according to the existence of OHGW and MW and the grounding conditions of the MW in the Korean distribution system. The grounding conditions of the MW that we took into consideration were the common or separate grounding of the MW and NW. The analysis based on the equivalent circuit of the distribution pole at each condition was performed. The distribution lines and lightning were modeled using the Electromagnetic Transients Program (EMTP). For each of the installation conditions of the OHGW and MW, the various lightning conditions were simulated and analyzed for both direct and indirect lightning. The simulation results showed that, if the OHGW was not installed in the Korean distribution system, the lightning overvoltage could be reduced by the common grounding of the MW and NW.

Overvoltage Protection Controller Design of Distributed Generation Connected to Power Grid Considering Islanding Condition

  • Cha, Jae-Hun;Park, Kyung-Won;Ahn, Hong-Seon;Kwon, Kyoung-Min;Oh, Jin-Hong;MAHIRANE, Philemon;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.599-607
    • /
    • 2018
  • Distributed generation (DG) is being highlighted as an alternative for future power supplies, and the number of DG systems connected to conventional power systems is steadily increasing. DG generators are designed using power electronics and can give rise to various power quality problems, such as overvoltage or overcurrent. Particularly, unintentional islanding operation can occur in a conventional power system when the power grid is separated from the DG systems. Overvoltage may occur in this situation, depending on the power generation and power consumption. However, overvoltage phenomena might not happen even when islanding occurs. Therefore, it is necessary to analyze the fault characteristics during islanding. In this study, a fault analysis of islanding operation was carried out using PSCAD/EMTDC, and a countermeasure for the overvoltage problem is proposed.

A Study on Overvoltage Protection for HID Lamp (HID 안정기에서의 보호회로에 관한 연구)

  • Han, Soo-Bin;Park, Suck-In;Jung, Hak-Kun;Song, Eu-Gine;Jung, Bong-Man
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.215-217
    • /
    • 2008
  • This paper suggests a overvoltage protection scheme for HID lamp. HID lamp has complex characteristics and long duration in process from starting to steady state condition. So it is necessary to protect both starting and normal lighting mode. The protection method is composed of two circuit: one is for ignition state and the other is for steady state.

  • PDF

Improved Gate Drive Circuit for High Power IGBTs with a Novel Overvoltage Protection Scheme (과전압 제한 기능을 갖는 새로운 IGBT 게이트 구동회로)

  • Lee, Hwang-Geol;Lee, Yo-Han;Suh, Bum-Seok;Hyun, Dong-Seok;Lee, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.346-349
    • /
    • 1996
  • In application of high power IGBT PWM inverters, the treatable power range is considerably limited due to the overvoltage caused by the stray inductance components within the power circuit. This paper proposes a new gate drive circuit for IGBTs which can actively suppress the overvoltage across the driven IGBT at turn-off and the overvoltage across the opposite IGBT at turn-on while preserving the most simple and reliable power circuit. The turn-off driving scheme has adaptive feature to the amplitude of collector current, so that the overvoltage is limited much effectively at the larger collector current. The turn-on scheme is to decrease the rising rate of the collector current by increasing input capacitance during turn-on transient when the gate-emitter voltage is greater than threshold voltage. The experimental results under various normal and fault conditions prove the effectiveness of the proposed circuit.

  • PDF