• 제목/요약/키워드: Overheat

검색결과 73건 처리시간 0.028초

통계적 패턴인식에 의한 유도가열 솥의 비파괴 불량 검사 방법 (A defect inspection method of the IH-JAR by statistical pattern recognition)

  • 오기태;이순걸
    • 제어로봇시스템학회논문지
    • /
    • 제6권1호
    • /
    • pp.112-119
    • /
    • 2000
  • A die-casting junction method is usually used to manufacture the tub of an IH(induction heating) jar. If there is a very small air bubble in the junction area, the thermal conductivity is deteriorated and local overheat occurs. Such problem brings serious inferiority of the IH jar. In this paper, we propose a new method to detect such defect with simply measured thermal data. Thermal distribution of preheated tubs is obtained by scanning with infrared thermal sensors and analyzed with the statistic pattern recognition method. By defining the characteristic feature as the temperature difference between sensors and using ellipsoid function as decision boundary, a supervised learning method of genetic algorithm is proposed to obtain the required parpameters. After applying the proposed method to experiment, we have proved that the rate of recognition is high even for a small number of data set.

  • PDF

발전기의 불평형 검출을 위한 디지털 역상 계전 알고리즘 (Digital Negative Sequence Relay Algorithm for Detection of Unbalanced State in a Generator)

  • 박철원
    • 전기학회논문지P
    • /
    • 제62권4호
    • /
    • pp.198-203
    • /
    • 2013
  • There are conditions that can be unbalanced three phase currents in a large generator by untransposed lines, unbalanced loads, unsymmetrical faults, and open phases. The unbalanced conditions can producing negative sequence components of current that induce two times frequence current in the surface of the rotor, the retaining rings, the slot wedges in the field windings. These rotor currents make the rotor rapidly overheat, so the rotor can cause substantial damage in a very short time. This paper presents the digital negative sequence relay algorithm for unbalanced protection in a generator. The proposed algorithm was tested by using collected current signals on PSCAD/EMTDC considering a hydro turbine based generator control system. It can be seen that the proposed relaying by negative sequence current is useful for detection of unbalanced state of large generator.

3상 4선식에서 비선형 부하의 운전시 유도전동기의 특성 해석 (Characteristics Analysis of Induction Motor by Operation of Non- linear Loads under the 3-phase 4-wire grid system)

  • 김종겸;박영진;이은웅
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.43-48
    • /
    • 2006
  • This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system. Under the combination operation of single & three phase load, voltage unbalance will be generated and current unbalance will be more severe by the dropped voltage quality. All power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. Moors may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration.

  • PDF

노트북 컴퓨터 어댑터용 LLC 하프 브리지 공진형 컨버터 최적설계 (Optimal Design of the LLC HB Resonant Converter for Notebook Computer Adapter)

  • 유병선;김창선
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1418-1423
    • /
    • 2007
  • The topology of LLC half bridge resonant converter provides ZVS characteristic. The voltage stress and current stress are smaller than that of the general resonant converters. So the LLC HB resonant converter can be considered as a optimal circuit for the notebook computer adapter. In the adapter design, we should consider the weight, the size and the overheat of the adapter. Thus the higher efficiency is an essential particular. First of all, the optimal design of transformer is the most important facts. Some parameters should be considered in order to get the highest efficiency. The adapter is designed through the considering of these parameters including the PFC circuit as the pre-regulator. It converts AC line input into about DC 390V link voltage of the LLC HB converter input and the converter has 16V/90W ratings. The efficiency measured is about up to 93%.

고압전동기 고정자권선의 턴단락 및 소선단락 써지시험 특성분석 (Surge Property Analysis for Shorted Turn and Shorted Strand in High Voltage Motor Stator Winding)

  • 공태식;김희동;이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2030-2031
    • /
    • 2007
  • This paper is purpose to understand the surge property for the shorted turn or shorted strand in high voltage motor stator windings. a shorted turn in high voltage motor windings causes a huge circulating current. and overheat windings, consequently burns the motor. a few shorted strands not cause winding failure immediately, but they increase the winding loss and temperature increase due to contact resistance. We carried out the surge test for three cases, normal winding, shorted turn winding and shorted strand winding. and we analyzed the test result.

  • PDF

전기철도에서의 고조파 발생과 계통응답특성(I) - 계통응답특성을 중심으로 - (Harmonic Generation and System Response Characteristics in Electrified Railway(I) - Focused on System Response Characteristics -)

  • 오광해;이장무
    • 한국철도학회논문집
    • /
    • 제7권1호
    • /
    • pp.60-64
    • /
    • 2004
  • Harmonic current originating from electric locomotives can be magnified due to the impedance characteristics of power supply circuit and bring about various problems. That is, electromagnetic interference with communication lines, operational trouble in signaling, overheat and/or vibration in power capacitor, mis-operation in protection relay and so on. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. for these reasons, this study propose a new approach to model and to analyse traction power feeding system focused on system response to current and voltage harmonic(PART I). Measurements of harmonics are also performed for railway power supply systems under normal operation. Spectrum and distortion analyses in measurement data are variously described in PART II.

5.56mm 소총 과열에 의한 운용한계 분석 - 인간공학 중심으로 (Study on Operating Limits of 5.56mm Rifle Overheat - Focusing on Human Engineering)

  • 이호준;최시영;신태성
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.49-56
    • /
    • 2020
  • 소총 사격 중 발생하는 고온의 열은 총기의 성능을 저하시킬 뿐 아니라 사용자의 원활한 운용에 제한을 가져온다. 본 연구에서는 인간공학 설계 기준을 참조하여 사격에 따른 총열덮개의 온도변화를 측정하고 재질에 따른 운용성을 검토하였다. 인간공학 설계 기준은 피부에 직접적으로 닿을 경우 단열재를 필요로 하는 것을 명시하고 있다. 이에 따라 사격시험을 위하여 총열덮개의 재질별로 대한민국 제식소총 3종과 해외 모델 1종을 선정하였으며, 접촉식 온도 측정기를 이용하여 사격시험을 실시하였다. 시험결과 열전도도가 낮은 플라스틱 총열덮개를 사용하는 소총과 열전도도가 높은 알루미늄 총열덮개를 사용하는 소총 모두 낮은 온도에서 100발 이상 사격에도 맨손으로 운용이 가능하였다. 그러나 평균 대기온도에서 약 60발 이상 사격 시 알루미늄 총열덮개는 맨손으로 운용이 제한되며, 다량으로 빠른 시간에 사격이 이뤄질 경우 덮개 재질에 관계없이 총열덮개의 운용이 제한되었다. 소총의 발열에 의한 운용제한 해소를 위해서는 장갑 또는 손잡이, 덮개 등을 활용하여 피부와 직접적인 접촉 차단이 필요하다. 본 연구를 통해 소총의 열 위험에 대한 운용성을 파악할 수 있었으며, 타 소총 및 군수품의 인간공학적 설계를 위한 기초자료로 활용 될 수 있을 것으로 기대된다.

향 검지 시스템의 특성 해석 및 평가에 관한 연구 (A Study on the Properties Analysis and Estimation of Odor Detection System)

  • 최충석
    • 한국화재소방학회논문지
    • /
    • 제23권2호
    • /
    • pp.1-5
    • /
    • 2009
  • 본 연구에서는 분전반의 설치 형태를 조사하였고, 향 검지 시스템의 재현 실험을 통해서 전기 재해 예방의 가능성을 확인하고자 한다. 주택용 분전반 내에 설치된 차단기는 MCCB, RCD 순서로 되어 있으나, 산업용은 혼용되고 있다. 접속이 부적절하게 된 단자대에 가진기를 이용하여 진동을 가했을 때 불꽃이 확인되었다. 단자대에 향 캡슐을 부착하여 실험한 결과, 발생한 열에 의해 캡슐이 정확하게 작동되었다. 센서의 설치 위치에 따라 검지 시간의 차이는 약 10초 이었다. 향 검지 시스템은 전기 설비 사고 예방이 가능한 것으로 판단된다. 전선의 접속부에서 이상 발열이 있을 때 과열의 상태를 관리자에게 경보해 줌으로써 사고 예방이 가능할 것으로 판단된다.

선형 및 비선형 부하 혼합 운전시 유도전동기의 동작 분석 (Operation Analysis of Induction Motor under the Combination of Linear & Non-linear Loads)

  • 김종겸;박영진;이동주;김준호;이종한;정종호;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.65-67
    • /
    • 2006
  • This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system. Under the combination operation of single & three phase load, voltage unbalance will be generated and current unbalance will be more severe by the dropped voltage quality. All power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. Motors may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration.

  • PDF

비선형 부하에 적용이 가능한 IED에 관한 연구 (A Study on the Intelligent Electronic Device for Non-Linear Loads)

  • 박종찬;김병진;김수곤;전희종
    • 전력전자학회논문지
    • /
    • 제8권5호
    • /
    • pp.381-388
    • /
    • 2003
  • 본 논문에서는 IED(Intelligent Electronic Devices)에서의 고조파 문제를 연구하였다. 최근 전력전자 기술의 급격한 발전으로 비선형부하에 의한 전력 품질의 왜곡이 심각해지고 있다. 연속적인 고조파 전류는 전련기기의 수명을 단축시키고 발열 문제가 발생하며 비정상적인 동작을 유발한다. 이러한 문제를 해결하기 위한 디지털 보호계전 시스템에서 전통적인 방법으로 전력을 계측하면 고조파의 영향을 고려할 수 없다. 이러한 문제를 해결하기 위하여 본 연구에서는 TMS320C32 DSP와 CPLD를 이용한 IED prototype을 구현하여 실험을 통해 성능을 확인하였다.