• 제목/요약/키워드: Overhead-line

검색결과 455건 처리시간 0.036초

전차선로 검측을 위한 네트워크 기반 델레메트리 시스템 개발 (The Development of Network-based Telemetry System for Railway Catenary Inspection)

  • 나해경;박영;조용현;박현준;최원석;김응권;송준태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.478-479
    • /
    • 2007
  • With increasing interest in the reduction of cost for operation and maintenance of overhead catenary system, various methods of condition monitoring have been developed. In this paper, we proposed network-based telemetry system for condition monitoring in railway and acquired data from any kind of sensor in catenary line and structure at high voltage. This development gives the solution for online condition monitoring in railway. To check the validity of our approach in terms of application, we realized network-based telemetry System.

  • PDF

순간전압강하 가혹지역에 기반한 사고예방 대책 수립 (Establishment of Preventive Measures against Faults Based on the Area of Severity to Voltage Sags)

  • 박창현;이계병;이한상;윤동희
    • 전기학회논문지
    • /
    • 제64권11호
    • /
    • pp.1611-1617
    • /
    • 2015
  • This paper presents an effective approach for establishing countermeasures against voltage sags based on the concept of area of severity. In order to apply preventive measures against faults such as lightning arrester, overhead earth wires and so on, it is important to find optimal points for installing the preventive measures. The optimal points can be determined by the calculation of the area of severity(AOS) to voltage sags and the expected sag frequency per unit length of line. In this paper, an effective method to find optimal points to apply countermeasures against voltage sags is addressed with case studies.

154kV 수전설비용 가선금구(인류형 클램프)와 자기애자에서 발생하는 코로나 특성 (Corna Characteristics of Between Compression Clamp or Dead End clamp and Porcelain Insulator Used 154kV Receiving Electrical Facility)

  • 한운기;김종민;방선배;김한상;최형준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2044-2045
    • /
    • 2007
  • 코로나 발생은 전극의 첨점이 형성되어 전극에 전계가 집중될 경우 불균질성에 의한 방전이다. 수용가용 154kV 인류형 클램프 말단의 전선처리는 코로나 발생을 가속시켜 전력손실, 노이즈 발생 등의 영향을 미친다. 본 연구에서는 수용가용 154kV 수전설비용 자기애자 (Porcelain Insulator)와 가공선로(Overhead Line)의 지지용 금구사이에서 발생하는 코로나 특성을 고찰하였다, 일반적 방법으로 확인 되지않는 코로나를 UV Image 이용하여 애자의 소손 위험성 및 상태를 제시하였으며, 유한요소법(FEMLAB)을 이용하여 나전선의 길이별로 전계분포에 의한 위험성을 제시하였다. 수전설비의 설치조건 및 금구류의 유지보수 및 안전성 향상에 활용될 것으로 기대한다.

  • PDF

배전용 지지물의 FRP 적용 기술 (Applied Technology of FRP Single Pole for Power Distribution Line)

  • 박기호;조한구;한동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.79-81
    • /
    • 2000
  • Outdoor insulation of overhead distribution lines with wood, concrete and steel pole has been safety under various environmental conditions including contamination, moisture condensation, rain and lightning overvoltages. In this paper introduce to FRP technology of the power distribution single pole. FRP pole has been used very much as high strength material for insulators because of its high strength and good insulation properties. In addition, FRP pole was made by filament winding method. In a filament winding process, a band of continuous resin-impregnated rovings or monofilaments is wrapped around a rotating mandrel and cured to produce axisymmetric hollow parts.

  • PDF

지중케이블 변전소의 고장전류 분류율과 접지전위상승 특성 (Characteristics of Fault Current Division Factor & Groud Potential Rise of a Substation fed exclusively by Power Cables)

  • 최종기;정길조;김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.295-297
    • /
    • 1998
  • This paper shows characteristics of fault current division factor $S_f$, which is a ratio of earth- return current to total fault current, at a substation fed exclusively by power cables under unsymmetrical fault condition, such as single line-to-ground fault. In substation grounding system design, $S_f$ is a very important factor determining GPR, touch and step voltage at a substation under fault condition. In case of substations fed by overhead lines, 40-60% of $S_f$ has been typically used, although it is a very conservative value with no other network conditions considered. It is authors' hope that $S_f$ presented in this paper could hopefully be a basic reference in designing of substation grounding system, especially for a substation fed exclusively by power cables.

  • PDF

인입선 분기함의 안전대책에 관한 연구 (Safety Countermeasure of the distribution box of service wire)

  • 하태현;배정효;이현구;김대경;하윤철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.246-248
    • /
    • 2004
  • The lower voltage distribution box of service wire has been usually employed to supply an electric power to the consumers through low voltage overhead line. Now-a-days, electric shock accident at the distribution box of service wire installed in the seashore areas has been often occurred. The reason is mainly due to the electric leakage in the distribution box of service wire. This paper described insulation breakdown mechanism of distribution box of service wire, analysis of electric shock path and safety countermeasure of distribution box of service wire.

  • PDF

가공용 가스절연부하개폐기 가속수명시험 (Accelerated life test of SF_6 gas load break switch for overhead line)

  • 박승재;허종철;김맹현;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.551-553
    • /
    • 2004
  • SF_6 gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, with these trends, SF_6 load break switches have rapidly substituted for the air or oil-type load break switches, in order to get higher reliability. And, the national standard was made for reliability assessment of SF_6 gas load break switch and testing facilities was also set in KERI(Korea Electrotechnology Research Institute ). This paper introduces the synopsis for the reliability assessment requirements specified in the standard and the assessment results.

  • PDF

22.9kV 가공배전선로의 뇌 과전압 모의 및 실측 연구 (An Experimental Study on the Lightning Over-Voltages on 22.9kV Multi-Grounded Overhead Distribution Lines Simulated Using Impulse Current Generator and True-type Test Line)

  • 류희석;정동학;남기영;이재덕;김대경;박상만;정영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.372-374
    • /
    • 2004
  • 22.9kV 가공배전선은 여러 요소들로 구성되기 때문에 뇌격에 대한 반응도 단순하지 않다. 현재의 절연협조는 대표적인 선로모델에 패한 선로상수, 접지저항 등의 대표 값을 사용하여 EMTP로 계산한 뇌충격과전압 값을 근거로 하고 있다. 절연협조 수준에 따라 경제성이 결정되고 계산에 의한 모델해석결과는 실제의 현상과 많은 차이를 나타낼 수 있음에도 불구하고 현재의 기준은 계산과정에서 사용되는 모델과 특성 값의 유효성을 확인하는 수준에 머물고 있다. 이 연구에서는 ICG로 충격전류를 인가하여 여러 가지 경우에 애자 양단에 인가되는 과전압을 실측하였다. 실측 결과 접지특성은 애자에 인가되는 과전압에 많은 영향을 미치지 않는다는 것을 알 수 있었다.

  • PDF

AR모델을 이용한 직류 옵셋 성분 제거 알고리즘 (A DC-Offset Elimination Algorithm Based on an AR Model)

  • 장수영;이동규;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.289-291
    • /
    • 2004
  • ln this paper, A dc-offset elimination novel algorithm based on an An model is proposed. The algorithm can eliminate dc-offset rapidly than other algorithms. The signal of fault current can be presented as a linear equation combined sinusoidal with exponential signals. Then, the linear equation can be presented an auto-regressive(AR) model and do-offset can be calculated by the equation of AR model. So it is possible to be removed the dc-offset from the original current signal. Performance evaluation of the algorithm was tested on condition that A-phase ground fault on 154kV 25km overhead transmission line.

  • PDF

FTA를 이용한 교류전철변전소의 신뢰도 분석 (Reliability Analysis of AC Railway Substation by using FTA)

  • 구본희;차준민;김형철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.248-254
    • /
    • 2008
  • Electric railway system consists of traction power system, rolling stock, track, and overhead line system. A railway substation transforms the electric power transmitted from a electric power company and supply it to the railway power system for the operation of traction system.. It is very important to prevent a possible accident and keep the security of electric power system. This paper proposes a reliability analysis of AC railway substation by using Fault Tree Analysis(FTA). Failure rates of each equipment of railway substation are used to evaluate the reliability of railway substation. The analyzed results can be used to improve the system reliability. FTA is performed by the commercialized program of Relex(Ver. 7.7).

  • PDF