• 제목/요약/키워드: Overdenture attachment

검색결과 103건 처리시간 0.022초

상악 임플랜트 Overdenture에서 Bar Attachment 설계에 따른 유지력 변화에 관한 연구 (COMPARATIVE STUDIES OF RETENTIVE FORCES IN MAXILLARY OVERDENTURE BAR ATTACHMENTS)

  • 손차영;정창모;전영찬;임장섭;정희찬
    • 대한치과보철학회지
    • /
    • 제43권5호
    • /
    • pp.650-661
    • /
    • 2005
  • Statement of problem: It could be hypothesised that attachments, which provide more retention against vortical and horizontal dislodgement, will be associated with more favorable parameters of oral function. Purpose: This study was to provide data of initial retentive force and retention loss of different bar attachment systems recommended for use with maxillary implant overdentures. Material and method: 4 implants were placed in the anterior region of edentulous maxilla, five different systems of bar attachment were fabricated as follows: cantilevered Hader bar using clips (Type 1), Hader bar using clips without cantilever (Type 2), Hader bar using clip and ERA attachment orange male (Type 3), Hader bar using clip and ERA attachment white male (Type 4), and Bar using magnets (Type 5). Each samples were placed in the universal testing machine for determination of retentive forces(at initial and after every 200 cycles up to 1,000 cycles). Results and Conclusion 1. Attachment type 1 showed the biggest initial retentive force followed by type 3, type 2, type 4, and lastly type 5(P<0.001). 2. After 1,000 cycles of repeated removals of attachments, significant loss of retentive forces was taken place except for attachment type 5. 3. After 1,000 cycles of repeated removals, the loss of retentive force between type 1 and type 2, which used Hader bar and clip attachments. was greater in type 1 that had wider clip formation. And between type 3 and type 4, which used ERA attachments, the loss of retentive force was greater in type 4 that had white male attached (P<0.001). 4. After 1.000 cycles of repeated removals, attachment type 3 showed the biggest retentive force followed by type 2, type 4, type 1 and lastly type. 5. There was no significant difference between attachment type 3 and 4, and type 4 and 1(P<0.001).

임플랜트지지 피개의치를 이용한 무치악환자의 구강회복 (Mandibular Implant-Retained Overdenture: A Case Report)

  • 이홍석;송광엽;김자영;이정준;박주미;안승근;박찬운
    • 구강회복응용과학지
    • /
    • 제24권1호
    • /
    • pp.91-104
    • /
    • 2008
  • 최근에, 의치의 유지, 안정성, 지지를 개선시키기 위해 골유착 임플란트가 사용되고 있다. 여러 연구에서 하악에 두 개의 임플란트를 식립한 후 제작된 피개의치가 환자 보철에서 기능과 만족의 유의한 증가를 나타내고 있다. stud, magnet, 그리고 bar attachment를 포함하여 다양한 attachment 시스템을 사용해 임상적으로 예상 가능하고 효과적인 것이 증명되었다. 본 증례에서 2개의 임플란트를 이용한 피개의치가 무치하악의 치료를 위한 고려의 기본이 될 수 있다는 것을 나타낸다.

Bar attachment와 Konus telescope를 이용한 부분 무치악 환자의 수복 (Clinical Appliance of Konus Telescope Denture and Bar-Retained Overdenture on Partially Edenturous Patient)

  • 최성호;심준성;이호용;이근우
    • 구강회복응용과학지
    • /
    • 제18권2호
    • /
    • pp.119-126
    • /
    • 2002
  • The purpose of this study was to restorate a patient who has a few remaining teeth with #15,23,24 supported Konus telescope denture in Maxillar and #44,43,33,34 supported Dolder bar retained overdenture in Mandible. Konus telescope and bar retained overdenture was taken better results in retention, support, stability compair with regular Removable partial denture. In Removable partial denture, the change of remaining teeth and edentulous ridge is natural. But Konus telescope and bar retained overdenture is a little effected in this change, so it is possiblble in long-term use. In cosider of patient's medical history and the possibility of additional tooth loss, Konus telescope denture can be easily repaired. Compaired with Konus telescope and bar retained overdenture showed high stability and easy cleansing because of rigid support, cross - arch splinting, and simple design. In delivery, patient had a difficulty with removal of denture and plaque control, but showed better condition, good oral hygienic care. Patient satisfied with denture functionally and esthetically. This study showed Konus telescope and bar retained overdenture was effective for treatment of patient remaing a few teeth in function, esthetic and psycologic satisfaction.

Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage

  • Kim, Min-Jeong;Hong, Sung-Ok
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.85-93
    • /
    • 2016
  • PURPOSE. The purpose of this study was to determine the effect of anchorage systems and palatal coverage of denture base on load transfer in maxillary implant-retained overdenture. MATERIALS AND METHODS. Maxillary implant-retained overdentures with 4 implants placed in the anterior region of edentulous maxilla were converted into a 3-D numerical model, and stress distribution patterns in implant supporting bone in the case of unilateral vertical loading on maxillary right first molar were compared with each other depending on various types of anchorage system and palatal coverage extent of denture base using three-dimensional finite element analysis. RESULTS. In all experimental models, the highest stress was concentrated on the most distal implant and implant supporting bone on loaded side. The stress at the most distal implant-supporting bone was concentrated on the cortical bone. In all anchorage system without palatal coverage of denture base, higher stresses were concentrated on the most distal implant and implant supporting bone on loaded side. CONCLUSION. It could be suggested that when making maxillary implant retained overdenture, using Hader bar instead of milled bar and full palatal coverage rather than partial palatal coverage are more beneficial in distributing the stress that is applied on implant supporting bone.

Immediate loading on mandibular edentulous patient with SFI Bar$^{(R)}$ overdenture

  • Kim, Ha-Young;Kim, Jin-Young-Ryan;Qadeer, Sarah;Jeong, Chang-Mo;Shin, Sang-Wan;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권1호
    • /
    • pp.47-50
    • /
    • 2011
  • Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar$^{(R)}$ (Cendres et Me$\'{e}$taux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.

상악 임플란트 피개의치에서 유지장치 종류와 구개 피개 유무에 따른 응력분포에 대한 유한요소분석 (Effect of attachments and palatal coverage of maxillary implant overdenture on stress distribution: a finite element analysis)

  • 박종희;왕원곤;이정진;박연희;서재민;김경아
    • 구강회복응용과학지
    • /
    • 제36권2호
    • /
    • pp.70-79
    • /
    • 2020
  • 목적: 상악 임플란트 피개의치에서 유지장치 종류와 구개 피개 유무에 따른 응력분포를 3차원 유한요소분석법을 통해 알아보고자 한다. 연구 재료 및 방법: CAD를 이용하여 전방부에 4개의 임플란트를 식립한 4종류의 상악 임플란트 피개의치에 대한 3차원 모델을 디자인하였다. 1) Ball-F: 볼 유지장치를 사용하고 구개를 피개한 군, 2) Ball-P: 볼 유지장치를 사용하고 구개를 피개하지 않은 군, 3) Bar-F: 바 유지장치를 사용하고 구개를 피개한 군, 4) Bar-P: 바 유지장치를 사용하고 구개를 피개하지 않은 군. 응력분석은 유한요소 분석 프로그램인 ANSYS Workbench Ver. 14를 사용하였으며, 편측 저작의 상황을 고려하여 우측 제1대구치에 100 N의 정적하중을 적용하여 임플란트, 임플란트 주위 골, 점막에 발생하는 최대 응력값을 기록하였다. 결과: 볼 유지장치를 사용한 군이 바 유지장치를 사용한 군보다 임플란트 및 임플란트 주위골에 발생하는 최대 응력값이 작았다. 하지만 점막에서의 최대 응력값은 그 반대로 나타났다. 구개를 피개하면 유지장치의 종류와 무관하게 임플란트, 임플란트 주위 골, 점막 모두에서 최대응력값이 작아졌다. 결론: 본 연구의 한계 내에서 상악동 전방부에 4개의 임플란트를 식립하여 수복된 피개의치에서 바 유지장치보다는 볼 유지장치를 사용하고 구개를 완전히 피개하는 경우가 임플란트와 임플란트 주위 골의 응력분산에 효과적이다.

상악 무치악 환자에서 Milled Bar와 ADD-TOC을 이용한 임플란트 피개의치 수복 증례 (Implant-assisted overdenture using milled bar and ADD-TOC in edentulous maxilla: A case report)

  • 조용범;정창모;허중보;윤미정;이소현;김민정
    • 대한치과보철학회지
    • /
    • 제60권2호
    • /
    • pp.160-167
    • /
    • 2022
  • 잔존골 흡수가 진행된 상악 무치악 환자의 수복 계획시 전통적인 총의치로의 치료보다는 임플란트를 식립 한 뒤 milled bar와 가철성 보철물을 제작하여 attachment로 연결하는 임플란트 피개의치를 우선적으로 고려할 수 있다. Milled bar와 attachment를 사용하면 상악 의치의 유지력 및 안정성의 증가뿐만 아니라 구개 피개 부위를 일부 감소시킬 수 있어 환자의 불편감을 줄여줄 수 있다는 장점이 있다. 또한 소수의 임플란트를 식립 할 경우 상부 보철물을 milled bar로 제작하면 임플란트 고정체 간에 연결고정되는 효과가 있어 저작과 같은 기능 하에서 역학적으로 유리해진다. 본 증례의 환자는 기존의 실패한 임플란트를 제거한 뒤 잔존 치조골이 상당량 소실된 상악 무치악 환자로 양측에 각 3개의 임플란트를 식립한 후 milled bar와 ADD-TOC attachment를 사용하여 임플란트 피개의치를 제작하였다. Attachment 장착을 통해 얻어진 부가적인 유지력을 바탕으로 구개부 피개량 감소하여 총의치 제작 가능하였고 이렇게 milled bar와 attachment를 병용하여 충분한 유지력 뿐만아니라 지지 및 안정을 얻음으로써 심미성 및 기능성 모두에서 만족할 만한 결과를 얻었기에 보고하는 바이다.

완전 무치악 환자에서 Locator® system을 이용한 임플란트 피개의치 수복 증례 (Implant Supported Overdenture using Locator® System on Edentulous Patient)

  • 이상엽;신수연
    • 구강회복응용과학지
    • /
    • 제24권4호
    • /
    • pp.351-359
    • /
    • 2008
  • 임플란트의 도입으로 악골이 흡수된 무치악 환자의 보철 치료에 획기적인 변화가 가능해졌다. 특히 하악 무치악 환자의 경우 2개의 임플란트에 의해 유지를 얻는 피개의치가 일반적인 총의치의 대안으로 자리잡았으며 첫 번째로 고려되어야 할 치료 방법으로 받아들여지고 있다. 본 증례는 상하악 완전 무치악 환자로서 상악에는 일반적인 총의치, 하악에는 2개의 임플란트를 식립하고 $Locator^{(R)}$ Attachment를 사용하여 수복한 임상과정 및 결과에 관하여 보고하고자 한다.

파킨슨 병을 가진 환자의 상악 마그네틱 피개의치 및 하악 임플란트 피개의치 수복 증례 (Overdentures of the patient with Parkinson's disease: A case report)

  • 민병귀;신은정;방몽숙;양홍서;박상원;윤귀덕;임현필
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.352-358
    • /
    • 2015
  • 파킨슨 병을 가지고 있는 환자의 총의치는 혀와 입술의 불수의적 운동으로 인해 유지와 안정이 좋지 않은 경우가 많다. 또한 제한된 수의 운동으로 인해 피개의치의 장착에 어려움이 어려울 수 있다. 본 증례는 파킨슨병을 가진 상, 하악 부분 무치악 환자에서 상악에서는 잔존치근을 이용한 magnetic attachment와 하악에서는 2개의 임플란트를 이용한 $Locator^{(R)}$ attachment를 통해 유지와 안정을 증진시킨 피개의치 수복증례로서, 기능적으로 개선된 보철물을 제작했기에 보고하는 바이다.

CAD/CAM system을 이용한 하악 임플란트 피개의치 수복증례 (The implant overdenture on the edentulous mandible using CAD/CAM system: A case report)

  • 이시은;이소현;전영찬;정창모;윤미정;허중보
    • 대한치과보철학회지
    • /
    • 제53권1호
    • /
    • pp.66-73
    • /
    • 2015
  • 완전, 혹은 부분 무치악 환자의 가철성 보철물 수복치료에서 치아 상실에 따른 치조골 감소와 별형은 의치 사용에 어려움을 준다. 이런 문제를 극복하기 위해 임플란트를 이용하여 가철성 보철물에 지지, 유지, 및 안정을 제공할 수 있다. 임플란트를 이용한 피개의치에 사용되는 어태치먼트는 여러 종류가 있는데, 환자의 여러 조건을 고려하여 어태치먼트를 선택해야 한다. 그 중 milled bar의 경우 임플란트 간 거리가 좁아서 기성 bar를 사용할 수 없는 경우, 또는 기성 bar보다 상부 구조물의 확고한 안정성과 지지를 얻고자 할 때 선택 된다. Milled bar는 cross arch stabilization을 이룰 수 있고, 저작 시 의치의 움직임이 없어 환자에게 편안함을 제공하지만, 숙련된 기공과정을 요한다. 그러나 최근 CAD/CAM의 발전을 통해 milled bar의 제작이 간결해지고 적합성을 증진시킬 수 있었다. 본 증례는 8개의 임플란트가 식립된 하악 완전 무치악의 알츠하이머 환자로 milled bar와 magnet을 이용한 피개의치를 제작하였다. 전신병력이 양호해진 기간 동안 빠른 치료종결이 필요했기 때문에, 통법의 기공 작업을 CAD를 통해 시뮬레이션하여 복잡한 기공과정을 좀더 단순하게 하였고 이로써 치료 기간을 줄일 수 있었다. 이상과 같이 milled bar를 이용한 임플란트 지지 피개의치를 제작하는 과정 중 CAD/CAM system을 적절히 사용하여 심미적, 기능적으로 만족할 만한 결과를 얻었기에 보고하고자 한다.