• Title/Summary/Keyword: Overcurrent Relay

Search Result 59, Processing Time 0.039 seconds

Optimal Setting of Overcurrent Relay in Distribution Systems Using Adaptive Evolutionary Algorithm (적응진화연산을 이용한 배전계통의 과전류계전기 최적 정정치 결정)

  • Jeong, Hee-Myung;Lee, Hwa-Seok;Park, June-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1521-1526
    • /
    • 2007
  • This paper presents the application of Adaptive Evolutionary Algorithm (AEA) to search an optimal setting of overcurrent relay coordination to protect ring distribution systems. The AEA takes the merits of both a genetic algorithm (GA) and an evolution strategy (ES) in an adaptive manner to use the global search capability of GA and the local search capability of ES. The overcurrent relay settings and coordination requirements are formulated into a set of constraint equations and an objective function is developed to manage the overcurrent relay settings by the Time Coordination Method. The domain of overcurrent relays coordination for the ring-fed distribution systems is a non-linear system with a lot of local optimum points and a highly constrained optimization problem. Thus conventional methods fail in searching for the global optimum. AEA is employed to search for the optimum relay settings with maximum satisfaction of coordination constraints. The simulation results show that the proposed method can optimize the overcurrent relay settings, reduce relay mis-coordinated operations, and find better optimal overcurrent relay settings than the present available methods.

An Adaptive Overcurrent Relay for a Wind Power Generator Having Variable Outputs (풍력발전기의 출력변화에 따른 적응형 과전류계전기)

  • Choi, Dong-Min;Kwon, Young-Jin;Lee, Dong-Kyu;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.99-101
    • /
    • 2005
  • This paper presents an adaptive overcurrent relay applied to interconnecting wind generators in distribution networks. When a fault occurs in the case of the decreasing the wind power generator output, the conventional overcurrent relay can't detect the fault. The suggested adaptive overcurrent relay can detect. An adaptive overcurrent relay improves reliability and security of the power system protection with distributed generator APSCAD/EMTDC simulation results have shown effectiveness of the proposed method.

  • PDF

A Study of the Operating Characteristic for Voltage Restrained Overcurrent Relay using the ATPDraw5.7p4 Modeling Data (ATPDraw5.7p4 모델링 데이터를 이용한 전압억제 과전류계전기 동작특성에 관한 연구)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • The market of domestic Power Plant Generator Protection and Control System (GPCS) is narrow and required the high reliability, and technology. So, it is still operated as turn-key. In recent years, digital relays has evolved into IED can perform the control and monitoring functions without central monitoring based on IEC61850 international standards communications, and attention for advancement of smart grid and ECMS has been increased in South Korea. The increasing attention on multi-function IED, DGPS(digital generator protection system), for internal fault protection of large generator results in starting a national project in South Korea, the IED prototype development for next-generation power units. The voltage restrained overcurrent relay have been used as back-up overcurrent protection for generators. In this paper, voltage restrained overcurrent relay is one of the back-up protective factors in generator protection IED was presented. For evaluation performance of the voltage restrained overcurrent relay, the data of ATPDraw5.7p4 modeling was used.

Correction of Overcurrent Protective Relay on Distribution Feeders Considering the Power Output of Wind Farm Interconnected with Utility Networks (계통 연계 풍력발전단지의 출력 조건을 고려한 배전선 과전류 계전기 정정)

  • Kim, J.W.;Jang, S.I.;Kim, K.H.;Yoo, N.S.;Park, H.J.;Song, D.S.;Lee, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.342-344
    • /
    • 2003
  • This paper describes the correction of overcurrent protective relaying set value in distribution networks interconnected with wind farm by dedicated line. The wind farm composed of wind turbine generators is one of the great energy sources; however, it would be also highly possible that the current in the point of common coupling is influenced by the output power of wind farm. So, the overcurrent relay applied in distribution feeders might generate trip signal for normal operation. In order to prevent the mal-operation of overcurrent relay, it is necessary to correct the relay's setting value according to the output power of end farm. This paper presents the influence of wind farm on the overcurrent relaying set value in distribution feeders for cases of fault as well as normal operation and proposes the basic strategy for correction of overcurrent relaying set value.

  • PDF

Study of Speed-biased Overcurrent Relay for High-Inertia Drive Motor (고관성부하용 전동기보호를 위한 속도감지형 과전류계전기 연구)

  • Lim, Jin-Ok;Cho, Sung-Don;Kang, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.506-508
    • /
    • 1995
  • The relay protection engineers are sometimes faced with the difficulties in full protection of high-inertia drive motors during acceleration period. The problem results from lower permitted locked rotor time of the motor compared with motor starting time. Even though the various types of protection relay and other device (Speed switch, Distance relay) are used, the full protections against abnormal starting conditions may not be available. So, the development of a new speed-biased overcurrent relay is suggested in this paper. This paper also presents that speed-biased overcurrent relay can fully protect the high-inertia motor during abnormal starting condition by computer simulation.

  • PDF

Study on Improvement of Overcurernt Relay (OCR)'s Operation Due to Application of Superconducting Fault Current Limiter (SFCL) in Power Distribution System with a Dispersed Generation (분산전원이 도입된 배전계통에 초전도한류기 적용에 따른 과전류계전기 동작향상 연구)

  • Lim, Seung-Taek;Lim, Sung-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.300-304
    • /
    • 2017
  • Due to the introduction of various types of dispersed generations (DGs) with larger capacity in a power distribution system, the short-circuit current is expected to be increased, which more requires for the effective fault current limiting methods. As one of the promising countermeasures, the superconducting fault current limiter (SFCL) has been noticed. However, the decreased fault current by SFCL affects the operation of the overcurrent relay (OCR), representative protective device in a power distribution system. In this paper, the operation of the overcurrent relay due to the application of a SFCL in a power distribution system with DG linked by its bus line was analysed through the short-circuit tests. To analyze the effect of the SFCL application in a power distribution system with DG, the experimental simulated circuits were designed and the short-circuit tests for the power distributed system assembled with the DG, the OCR and the SFCL were carried out. Through the analysis on the short-circuit tests, the application of the SFCL in a power distribution system with DG could be confirmed to be contributed to the operational improvement of overcurrent relay.

A Study on the Overcurrent Relay Coordination in Power Systems (전력계통에서의 과전류계전기 보호협조에 관한 연구)

  • Choi, Hong-Kyoo;Kim, Kyung-Chul;Oh, Jung-Suk;Kim, Byung-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.351-358
    • /
    • 2004
  • When fault occur in power systems, the protective relay plays a roles of protecting power system according to its setting values. There, it is very important that the protective relay have high selectivity performance in power system by correct setting the relays. This paper analyzed protect device protect cooperation or Transient stability and apply to Overcurrent relay in the real power system operation environment by using EDSA Program.

  • PDF

Development of the Automative Correction System for the Digital Over-current Relay With Distribution System (배전계통에서의 디지털 과전류 계전기 자동 정정 시스템 개발)

  • Baek, Young-Sik;Lee, Ho-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.677-682
    • /
    • 2007
  • In the distribution system, Change of system happens frequently. However, most of the relays are operated manually by a person or not changed when system changed. So, when fault happened, a case that relaydoes not act rapidly happens. Also, in current power system, digital relays are used because of digitization of relay. Digital relay has very many advantages than existing analog relay. One of these advantages is that communication is available and easily can make characteristic curve. If specific values are sent to a relay by communication, A relay can make suitable characteristic curve according to the value. In this paper, by using voltages and currents measured by relay, state of CB(Circuit Breaker) and these relays, SCADA(Supervisory Control And Data Acquisition) system that control and correct characteristic curve of overcurrent relay at system change by using HMI(Human Machine Interface) is proposed.

An Investigation on Correction of Overcurrent Protective Relaying Set Value for Bus Interconnected with Distributed Generations (분산전원의 계통 연계에 따른 모선 보호용 과전류 계전기 설정치 정정에 대한 고찰)

  • Jang, Sung-Il;Kim, Ji-Won;Park, In-Ki;Kwon, Hyouk-Jun;Kim, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.137-140
    • /
    • 2002
  • This paper describes the effect of distributed generations (DG) on the bus protection scheme. When the generating capacity of DG is larger than 3 MVA totally, DG are generally connected to the 22.9 kV bus directly with the dedicated line. Due to the fault current contribution of DG, the overcurrent protective relay that have conventional set value cannot detect the fault occurred in distribution power network with DG. Therefore. the impacts from interconnection of DG on the overcurrent protective relay for bus protection should be accurately assessed and mitigated. Simulation results show that it would be necessary to modify the overcurrent protective relay set value for protecting the bus according to the generating capacity of DG.

  • PDF

An Innovative Fast Relay Coordination Method to Bypass the Time Consumption of Optimization Algorithms in Relay Protection Coordination

  • Kheshti, Mostafa;Kang, Xiaoning;Jiao, Zaibin
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.612-620
    • /
    • 2017
  • Relay coordination in power system is a complex problem and so far, meta-heuristic algorithms and other methods as an alternative approach may not properly deal with large scale relay coordination due to their huge time consuming computation. In some cases the relay coordination could be unachievable. As the urgency for a proper approach is essential, in this paper an innovative and simple relay coordination method is introduced that is able to be applied on optimization algorithms for relay protection coordination. The objective function equation of operating time of relays are divided into two separate functions with less constraints. As the analytical results show here, this equivalent method has a remarkable speed with high accuracy to coordinate directional relays. Two distribution systems including directional overcurrent relays are studied in DigSILENT software and the collected data are examined in MATLAB. The relay settings of this method are compared with particle swarm optimization and genetic algorithm. The analytical results show the correctness of this mathematical and practical approach. This fast coordination method has a proper velocity of convergence with low iteration that can be used in large scale systems in practice and also to provide a feasible solution for protection coordination in smart grids as online or offline protection coordination.