• 제목/요약/키워드: Overall uncertainty

검색결과 285건 처리시간 0.027초

Motion-based design of TMD for vibrating footbridges under uncertainty conditions

  • Jimenez-Alonso, Javier F.;Saez, Andres
    • Smart Structures and Systems
    • /
    • 제21권6호
    • /
    • pp.727-740
    • /
    • 2018
  • Tuned mass dampers (TMDs) are passive damping devices widely employed to mitigate the pedestrian-induced vibrations on footbridges. The TMD design must ensure an adequate performance during the overall life-cycle of the structure. Although the TMD is initially adjusted to match the natural frequency of the vibration mode which needs to be controlled, its design must further take into account the change of the modal parameters of the footbridge due to the modification of the operational and environmental conditions. For this purpose, a motion-based design optimization method is proposed and implemented herein, aimed at ensuring the adequate behavior of footbridges under uncertainty conditions. The uncertainty associated with the variation of such modal parameters is simulated by a probabilistic approach based on the results of previous research reported in literature. The pedestrian action is modelled according to the recommendations of the Synpex guidelines. A comparison among the TMD parameters obtained considering different design criteria, design requirements and uncertainty levels is performed. To illustrate the proposed approach, a benchmark footbridge is considered. Results show both which is the most adequate design criterion to control the pedestrian-induced vibrations on the footbridge and the influence of the design requirements and the uncertainty level in the final TMD design.

Absolute Distance Measurements Using the Optical Comb of a Femtosecond Pulse Laser

  • Jin, Jong-Han;Kim, Young-Jin;Kim, Yun-Seok;Kim, Seung-Woo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권4호
    • /
    • pp.22-26
    • /
    • 2007
  • We describe a new way of implementing absolute displacement measurements by exploiting the optical comb of a femtosecond pulse laser as a wavelength ruler, The optical comb is stabilized by locking both the repetition rate and the carrier offset frequency to an Rb clock of frequency standard. Multiwavelength interferometry is then performed using the quasi-monochromatic beams of well-defined generated wavelengths by tuning an external cavity laser diode consecutively to preselected light modes of the optical comb. This scheme of wavelength synthesizing allows the measurement of absolute distances with a high precision that is traceable to the definition of time. The achievable wavelength uncertainty is $1.9{\times}10^{-10}$, which allows the absolute heights of gauge blocks to be determined with an overall calibration uncertainty of 15 nm (k = 1). These results demonstrate a successful industrial application of an optical frequency synthesis employing a femtosecond laser, a technique that offers many possibilities for performing precision length metrology that is traceable to the well-defined international definition of time.

소아과 외래와 응급실 내원 아동 부모의 불확실성 인지와 간호서비스 만족도 (Perception of Uncertainty and Satisfaction for Nursing Service of Children's Parents Visiting to Pediatrics Outpatient Department and Emergency Room)

  • 오진아
    • 부모자녀건강학회지
    • /
    • 제13권1호
    • /
    • pp.35-43
    • /
    • 2010
  • Purpose: This study was a descriptive research to provide fundamental data in ensuring a high quality of nursing service needed by children's parent according to perception of uncertainty and care satisfaction of them between pediatric outpatient department and emergency room. Methods: For this study, 192 children's parents were questioned in a general hospital located in Busan from August 1 to 31. 2009. The collected data were scored by use of frequencies, $x^2$ test, t-test, AONVA, Pearson's correlation coefficient via SPSS/WIN 17.0. Results: With the compare of characteristics related to children's parents visiting emergency room and pediatric outpatient department, there were statistically significant difference in relation and age of parent, main caregiver, cause of arrival, and waiting time from arrival to procedure. The perception of uncertainty for parent in the emergency room showed significant difference to outpatient department. In nursing service, the highest score was category of professional skill and technic. In addition, overall parents' perceptions on providing information showed lower than any other nursing service. Last but not least, a significant correlation indicated between the perception of uncertainty and satisfaction of nursing service. Conclusion: Efforts to improve parent satisfaction for nursing service are needed to decrease their perception of uncertainty. Providing information and communication by nurses are necessary to improve quality of nursing service.

  • PDF

표면미세가공기술을 이용한 수평감지방식의 정전용량형 다결정 실리콘 가속도계의 설계, 제작 및 가공 오차 영향 분석 (Design, Fabrication and Micromachining Error Evaluation for a Surface-Micromachined Polysilicon Capacitice Accelerometer)

  • 김종팔;한기호;조영호
    • 대한기계학회논문집A
    • /
    • 제25권3호
    • /
    • pp.529-536
    • /
    • 2001
  • We investigate a surface-micromachined capacitive accelerometer with the grid-type electrodes surrounded by a perforated proof-mass frame. An electromechanical analysis of the microaccelerometer has been performed to obtain analytical formulae for natural frequency and output sensitivity response estimation. A set of prototype devices has been designed and fabricated based on a 4-mask surface-micromachining process. The resonant frequency of 5.8$\pm$0.17kHz and the detection sensitivity of 0.28$\pm$0.03mV/g have been measured from the fabricated devices. The parasitic capacitance of the detection circuit with a charge amplifier has been measured as 3.34$\pm$1.16pF. From the uncertainty analysis, we find that the major uncertainty in the natural frequency of the accelerometer comes from the micromachining error in the beam width patterning process. The major source of the sensitivity uncertainty includes uncertainty of the parasitic capacitance, the inter-electrode gap and the resonant frequency, contributing to the overall sensitivity uncertainty in the portions of 75%, 14% and 11%, respectively.

매개변수화 어파인 모델에 기반한 꼬리날개 제어유도탄의 적응제어 (Adaptive Control based on a ParametricAffine Model for tail-control led Missiles)

  • 최진영;좌동경
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.2-2
    • /
    • 2000
  • This paper presents an adaptive control against uncertainties in tail-controlled STT (skid-to-Turn) missiles. First, we derive an analytic uncertainty model from a parametricaffine missile model developed by the authors. Based on this analytic model, an adaptive feedbacklinearizing control law accompanied by a sliding model control law is proposed. We provide analyses of stability and output tracking performance of the overall adaptive missile system. The performance and validity of the proposed adaptive control scheme is demonstrated by simulation.

  • PDF

Dynamic Aspects in Reconstructability Analysis: The Role of Minimum Uncertainty Principles

  • Klir, George J.
    • 한국지능시스템학회논문지
    • /
    • 제3권1호
    • /
    • pp.29-40
    • /
    • 1993
  • The role of principles of minimum uncertainty in dealing with the reconstruction problem of systems with dynamic properties is discussed. The aim of the reconstruction problem, one of two problems addressed by reconstruct ability analysis, is to determine the smallest possible sub-systems by which a given overall system can be adequately represented.

  • PDF

비구조적인 불확실성을 가지는 시스템에 대한 반복 제어기의 설계 (Design of a repetitive controller for the system with unstructured uncertainty)

  • 도태용;문정호;정명진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.779-782
    • /
    • 1996
  • Repetitive control is a proposed control strategy in view of the internal model principle and achieves a high accuracy asymptotic tracking property by implementing a model that generates the periodic signals of period into the closed-loop system. Since the repetitive control system contains a periodic signal generator with positive feedback loop, which reduces the stability margin, in the overall closed-loop system, the stability of the closed-loop system should be considered as an important problem. In case that a real system has plant uncertainties which are not represented through modeling, the robust stability problem of the repetitive control system has not been considered sufficiently. In this paper, we propose the robust stability condition for the system with modeling uncertainty. The proposed robust stability condition will be obtained using the robust performance condition in the H$_{\infty}$ control. Moreover, by use of the proposed robust stability condition, we propose a procedure that designs a repetitive controller and a feedback controller simultaneously which can stabilize the overall closed-loop system robustly and which can also do the closedloop system without repetitive controller..

  • PDF

대체용매를 이용한 금속가공유 측정방법 타당성에 대한 현장평가 (Field Validation of alternative extraction method for the determination of airborne MWFs)

  • 정지연;백남원
    • 한국산업보건학회지
    • /
    • 제19권2호
    • /
    • pp.96-101
    • /
    • 2009
  • The purpose of this study was to conduct the field validation of alternative method(ETM method) by using non-carcinogenic, and less toxic solvents than NIOSH (National Institute for Occupational Safety and Health) analytical method 5524 for measuring the airborne metalworking fluids in workplaces. We carried out the field validation test by using the exposure chamber, guaranteeing the air sampling homogeneously in a machining environment. The ETM mixed solvent presented the complete solubility of MWFs used in test field. Based on the field test data, the bias of the ETM method from reference method, NIOSH analytical method 5524, was from -7.0% to 5.1%. The overall uncertainty of the ETM nethod was 21.6%, which satisfied the NIOSH criteria for the sampling and analytical criteria.

항암화학요법을 받는 부인암 환자의 삶의 질에 관한 연구 (Quality of Life in Gynecological Cancer Patients During Chemotherapy)

  • 이주영;최스미
    • 여성건강간호학회지
    • /
    • 제13권4호
    • /
    • pp.290-298
    • /
    • 2007
  • Purpose: This study was to measure the quality of life(QOL) and to identify the related factors in gynecological cancer patients during chemotherapy. Method: The subjects of this study were the patients who had undergone a hysterectomy and were admitted for chemotherapy at S university hospital between November 2006 and April 2007. Data was collected from 106 gynecological cancer patients with the use of a structured questionnaire which measured the QOL(FACT-G), body image, the presence of anxiety & depression, uncertainty, and family support. The data was analyzed by the SPSS win 12.0 program. Results: The mean FACT-total score was 62.1$({\pm}16.7)$ (range; 26-107). Positive correlations were found between QOL and body image(r= .67, p= .00), and QOL and family support(r= .32, p= .00), whereas there were negative correlations between QOL and anxiety(r= -.54, p= .00), QOL and depression(r= -.70, p= .00), and QOL and uncertainty(r= -.59, p= .00). Fifty seven pre cent of the variance in subjective overall QOL can be explained by depression, body image, and uncertainty(Adj $R^2$= .57, F=47.00, p= .00). Conclusion: Our patients had a relatively low QOL score. Factors significantly affecting quality of life were depression, body image and uncertainty. Nursing interventions, therefore, should be focused on improving QOL in gynecological cancer patients during chemotherapy, particularly so in patients with depression, uncertainty or poor body image.

  • PDF

2,4-DNPH와 가스크로마토그래프를 이용한 포름알데히드 분석방법 (Analytical method for analyzing formaldehyde using 2, 4-DNPH and gas chromatography/FID, NPD)

  • 정지연;박승현;이광용;오세민
    • 한국산업보건학회지
    • /
    • 제10권1호
    • /
    • pp.126-146
    • /
    • 2000
  • To develop and evaluate formaldehyde measurement method using 2,4-dinitro-phenylhydrazine (2,4-DNPH) coated sampler and gas chromatography, laboratory test and field test were conducted. Results of this study are as follows. Limit of detection(LOD) of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is $0.008{\mu}g/m{\ell}$ $0.060{\mu}g/m{\ell}$, $0.472{\mu}g/m{\ell}$ respectively. Coefficiency of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is 0.008, 0.009, 0.020 respectively. Desorption efficiency of sep-pak xposure aldehyde sampler and sorbent sample tube is 1.05(range : 0.99 - 1.12), 1.02(range : 0.99 - 1.06) respectively. Samples of sorbent sample tube and sep-pak xposure aldehyde sampler turned out to be stored at refrigerator, according to storage test results. Measurement methods of HPLC-UVD, GC-NPD, GC-FID, according to results of precision for the combined sampling and analytical procedure, became acceptable to OSHA evaluation standard. Field test using exposure chamber met the NIOSH overall uncertainty recommendation(less than 25%). Overall uncertainty of Sepak-HPLC(UVD), Tube-GC(NPD), Tube-GC(FID) is 11.0% - 17.0%. Consequently gas chromatography(GC-NPD, GC-FID) and high performance liquid chromatography(EPA TO-11) using 2,4-DNPH coated sampler for formaldehyde measurement turned out to be suitable to measure personal formaldehyde exposure at workplaces.

  • PDF