• 제목/요약/키워드: Over-modulation region

검색결과 34건 처리시간 0.026초

A Simplified Carrier-Based Pulse-Width Modulation Strategy for Two-level Voltage Source Inverters in the Over-modulation Region

  • Jing, Feng;He, Feng-You
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1480-1489
    • /
    • 2017
  • In this study, a carrier-based pulse-width modulation (PWM) method for two-level voltage source inverters in the over-modulation region is proposed. Based on the superposition principle, the reference voltage vectors outside the linear modulation boundary are adjusted to relocate to the vector hexagon, while their fundamental magnitudes are retained. In accordance with the adjusted reference vector, the corresponding modulated waves are respectively deduced in over-modulation mode I and II to generate the gate signals of the power switches, guaranteeing the linearity of the fundamental output phase voltage in the over-modulation region. Moreover, due to the linear relationship between the voltage vector and the duty ratios, the complicated sector identification and holding angle calculation found in previous methods are avoided in the modulated wave synthesis, which provides great simplicity for the proposed carrier-based over-modulation strategy. Experimental results demonstrate the effectiveness and validity of the proposed method.

SVPWM Overmodulation Scheme of Three-Level Inverters for Vector Controlled Induction Motor Drives

  • Kwon, Kyoung-Min;Lee, Jae-Moon;Lee, Jin-Mok;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.481-490
    • /
    • 2009
  • This paper describes a SVPWM overmodulation scheme of NPC type three-level inverter for traction drives which extends the modulation index from MI=0.907 to unity. SVPWM strategy is organized by two operation modes of under-modulation and over-modulation. The switching states under the under-modulation modes are determined by dividing them with two linear regions and one hybrid region the same as the conventional three-level inverter. On the other hand, under the over-modulation mode, they are generated by doing it with two over-modulation regions the same as the conventional over-modulation strategy of a two level inverter. Following the description of over-modulation scheme of a three-level inverter, the system description of a vector controlled induction motor for traction drives has been discussed. Finally, the validity of the proposed modulation algorithm has been verified through simulation and experimental results.

과변조 영역에서의 3고조파 주입형 PWM 인버터 제어 (Control of the Third Harmonics Injected PWM Inverter in Over Modulation Mode)

  • 김영렬
    • 전력전자학회논문지
    • /
    • 제7권1호
    • /
    • pp.101-110
    • /
    • 2002
  • 본 논문에서는 3고조파를 주입한 정현파 PWM 인버터의 과변조 영역에서, 인버터 전압을 선형적으로 제어하기 위한 방법을 제시한다. 정현파 PWM에 3고조파를 삽입하면 단순한 정현파 PWM에 비해 선형영역을 확장할 수 있다. 그러나 이 경우에도 선형영역은 six-step 인버터에 비해 90% 정도까지가 된다. 따라서 PWM 인버터를 six-step 인버터의 출력에 이르기까지 선형적으로 제어하기 위해, PWM 인버터의 과변조 영역에서의 변조지수와 인버터 출력의 기본파 전압 크기와의 관계를 분석하여, 과변조 영역에서 기준전압을 보정해 줄 수 있는 방법을 제시하였다. 보정된 기준 전압을 명령 값으로 사용함으로써 반복 계산 없이 3고조파 주입형 정현파 PWM에서 출력전압을 six-steP에서의 전압에 이르기까지 선형적으로 제어할 수 있게 된다. 제안된 방법을 인버터-유도전동기 시스템에 대한 시뮬레이션을 통하여 확인하였고 실험으로 입증하였다.

A Dynamic Power Distribution Strategy for Large-scale Cascaded Photovoltaic Systems

  • Wang, Kangan;Wu, Xiaojie;Deng, Fujin;Liu, Feng
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1317-1326
    • /
    • 2017
  • The cascaded H-bridge (CHB) multilevel converter is a promising topology for large-scale photovoltaic (PV) systems. The output voltage over-modulation derived by the inter-module active power imbalance is one of the key issues for CHB PV systems. This paper proposed a dynamic power distribution strategy to eliminate the over-modulation in a CHB PV system by suitably redistributing the reactive power among the inverter modules of the CHB PV system. The proposed strategy can effectively extend the operating region of the CHB PV system with a simple control algorithm and easy implementation. Simulation and experimental results carried out on a seven-level CHB grid-connected PV system are shown to validate the proposed strategy.

과변조 영역에서의 제3고조파 주입형 PWM 인버터 제어 모델 분석 (Analysis of the Control Model of Third Harmonics Injected PWM Inverter in Over Modulation Mode)

  • 김영렬
    • 조명전기설비학회논문지
    • /
    • 제14권5호
    • /
    • pp.66-73
    • /
    • 2000
  • 본 논문에셔는 3고초파를 주입한 정현파 PWM 인버터의 과변조 영역에서 인버터를 전형적으로 제어하기 위한 새로운 방법을 제시한다. 정현파 PWM에 3고조파를 삽입하면 단순한 정현파 PWM에 비해 선형영역을 확장할 수 있다. 그러나 이 경우에도 선형영역은 six-step 인버터메 비해 90% 정도가 된다. 따라서 과변조 영역에서 변조지수와 인버터 출력의 기본파 전압의 크기에 대한 관계를 분석함으로써, 과변조 영역에서 기준전압올 보정해 줄 수 있다. 보정된 기준 전압을 명령값으로 사용하게 되므로 반복 계산 없이 3고조파 주입형 정현파 PWM에서 출력전압을 SIX-step에샤의 전압에 이로는 과변조 영역까지 선형적으로 제어가 가능하다. 인버터-유도전동기시스템에 대한 시뮬레이션 결과를 통하여 이를 확인하였다.

  • PDF

Reconfigurable Selective Harmonic Elimination Technique for Wide Range Operations in Asymmetric Cascaded Multilevel Inverter

  • Kavitha, R;Rani, Thottungal
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1037-1050
    • /
    • 2018
  • This paper presents a novel reconfigurable selective harmonic elimination technique to control harmonics over a wide range of Modulation Indexes (MI) in Multi-Level Inverter (MLI). In the proposed method, the region of the MI is divided into various sectors and expressions are formulated with different switching patterns for each of the sectors. A memetic BBO-MAS (Biogeography Based Optimization - Mesh Adaptive direct Search) optimization algorithm is proposed for solving the Selective Harmonic Elimination - Pulse Width Modulation (SHE-PWM) technique. An experimental prototype is developed using a Field Programmable Gate Array (FPGA) and their FFT spectrums are analyzed over a wide range of MI using a fluke power logger. Simulation and experimental results have validated the performance of the proposed optimization algorithms and the reconfigurable SHE-PWM technique. Further, the sensitivity of the harmonics has been analyzed considering non-integer variations in the magnitude of the input DC sources.

Advanced Static Over-modulation Scheme using Offset Voltages Injection for Simple Implementation and Less Harmonics

  • Lee, Dong-Myung
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.138-145
    • /
    • 2015
  • In this paper, a novel static overmodulation scheme (OVM) for space-vector PWM (SVPWM) is proposed. The proposed static OVM scheme uses the concept of adding offset voltages in linear region as well as overmodulation region to fully utilize DC-link voltage. By employing zero sequence voltage injection, the proposed scheme reduces procedures for achieving SVPWM such as complicated gating time calculation. In addition, this paper proposes a stepwise discontinuous angle movement in high modulation region in order to reduce Total Harmonic Distortion (THD). The validity of the proposed scheme is verified through theoretical analysis and experimental results.

3-level인버터를 이용한 과변조영역에서의 간접벡터 유도전동기 구동 (Driving the induction motor of indirect vector control using the 3-level inverter in the overmodulation region)

  • 이재문;정헌선;노세진;이은규;염상구;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.403-405
    • /
    • 2007
  • This paper presents the over-modulation strategy and indirect vector control drive of NPC type PWM inverter. NPC inverter has three level phase voltage output.It can perform in high voltage through assembling switching components. It has less harmonics and surge voltage stress at motor terminals than the 2 level inverter in same switching frequency through 3 level voltage. The conventional railway vehicle has used the vector control to MI=0.907 and the slip-frequency control from MI=0.907 to six-step mode. The slip-frequency control has bad motive power and slow torque control response. But vector control has good motive power and can instant torque control. In this paper, output voltage is controlled linearly from linear region to six-step mode by using over-modulation strategy. And NPC inverter is used.

  • PDF

Link Adaptation and Selection Method for OFDM Based Wireless Relay Networks

  • Can, Basak;Yomo, Hiroyuki;Carvalho, Elisabeth De
    • Journal of Communications and Networks
    • /
    • 제9권2호
    • /
    • pp.118-127
    • /
    • 2007
  • We propose a link adaptation and selection method for the links constituting an orthogonal frequency division multiplexing (OFDM) based wireless relay network. The proposed link adaptation and selection method selects the forwarding, modulation, and channel coding schemes providing the highest end-to-end throughput and decides whether to use the relay or not. The link adaptation and selection is done for each sub-channel based on instantaneous signal to interference plus noise ratio (SINR) conditions in the source-to-destination, source-to-relay and relay-to-destination links. The considered forwarding schemes are amplify and forward (AF) and simple adaptive decode and forward (DF). Efficient adaptive modulation and coding decision rules are provided for various relaying schemes. The proposed end-to-end link adaptation and selection method ensures that the end-to-end throughput is always larger than or equal to that of transmissions without relay and non-adaptive relayed transmissions. Our evaluations show that over the region where relaying improves the end-to-end throughput, the DF scheme provides significant throughput gain over the AF scheme provided that the error propagation is avoided via error detection techniques. We provide a frame structure to enable the proposed link adaptation and selection method for orthogonal frequency division multiple access (OFDMA)-time division duplex relay networks based on the IEEE 802.16e standard.

진행파 광변조기의 Taper영역 전극 설계 : SOR기법 (Design of Electrodes of the Tapered Region of the Traveling-Wave Optical Modulator: SOR Method)

  • 정석원;김창민
    • 한국광학회지
    • /
    • 제7권1호
    • /
    • pp.77-86
    • /
    • 1996
  • $Ti:LiNbO_3$ Mach-Zehnder 진행파형 광변조기의 CPW(coplanar waveguide) 전극구조, 특히 taper영역을 해석하기 위해서 SOR(successive over relaxation)법을 이용하였다. 변조기의 taper영역에서는 임피던스 정합, 즉 $Z_c 가 50\omega$이 만족되는 전극구조를 설계하였다. 변조기의 변조영역에서는 $Z_c=50\omega, n$$Z_c$ c/=50.OMEGA., n=2.26인 설계파라미터와, n$_{eff}$=2.2, Z$_{c}$=47.7.OMEGA.인 설계파라미터를 찾았다.

  • PDF