• Title/Summary/Keyword: Over Temperature Protection

Search Result 124, Processing Time 0.044 seconds

A STUDY OF LOW-LEVEL BOUNDARY-LAYER TEMPERATURE INVERSION EVENTS IN TAIWAN

  • Liou, Yuei-An;Yan, Shiang-Kun;Wang, Kuo-Chung
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.320-323
    • /
    • 2006
  • Temperature inversion may cause air pollution problems because air pollutants cannot be dissipated through vertical motion of the atmosphere and are accumulated near the surface. The air quality is worsen gradually if an inversion event lasts for a long time. An inversion event is defined as consecutive temperature profiles with occurrence of the temperature inversion condition. In this paper, temperature inversion events over three major cities on Taiwan are analyzed. They are measured by ground-based microwave radiometers installed in Taipei, Taichung, and Kaohsiung from 2002 to 2004 by the Environment Protection Administration (EPA) of Taiwan. Characteristics of temperature inversion events at the three cities are extracted using different classification methods.

  • PDF

Distributed fiber-optic sensor network for the over temperature protection relay of electric power systems (전력설비 보호를 위한 온도계전기용 광섬유 분배센서)

  • Park, Hyoung-Jun;Lee, June-Ho;Song, Min-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.86-90
    • /
    • 2006
  • We prosed a distributed fiber-optic sensor system with 10 fiber Bragg gratings, for over temperature protection relay in power systems. We applied Gaussian line-fitting algorithm to compensate the distortion effects in the wavelength-scanned Farby-Perot filter demodulation scheme. Compared with the highest-peak-detection method, the proposed algorithm was proved to minimize the random errors of distorted PD profiles. From experimental results, the overall measurement error was within 1 % compared with the reference thermocouple and the linearity error was less than 0.37 %.

  • PDF

The Coupled Electro-Thermal Field Analysis for Predicting Over-Current Protector Behavior

  • Bae, Jae-Nam;Lee, Sung-Gu;Han, Jung-Ho;Chung, Hae-Yang;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.7
    • /
    • pp.43-48
    • /
    • 2008
  • The characteristics of heat transfer of the bimetal disc for over-current protection device is specified. Bimetal consists of two metals which have a different thermal expansion coefficient. To analyze the thermal characteristics, temperature distribution when bimetal acts as a switch is calculated. As usual, heat source is applied to the bimetal and electric current is heat source in the over-current protection switch. In this paper, thermal distribution are obtained by solving a coupled electro-thermal field with 3D finite element method.

A Study on Railway Electric Traction Protection System (전철용 보호계전기 시스템에 관한 연구)

  • Lee, Hee-Yong;Kim, Wang-Gon;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1390-1395
    • /
    • 2004
  • Recently, the load increasement and new regenerative systems of electrified railway system make it a difficult to distinguish between the load current and fault current. The failure of traction system perhaps causes over-current to flow. The high current can collapse other railway systems. If failures of the traction system takes place, the failures are detected and protected lest it should provoke high current flow. The over current from such a traction system failure permit to charge high tension voltage and produces high temperature arc, voltage instability, current cutting, and break down railway systems. The traction system failures detect and the system has to immediately cut off from over-current flow. To isolate the failure, the system can distinguish failure current from current flows. It forces us to adapt such as a new intelligent protection system. The protective system in traction system play a role of detecting and isolating failure points. In this paper, we proposed intelligent algorithm for discriminating normal and abnormal situation instead of the system being operated abnormally.

  • PDF

A study on the safe operation condition for Bi-2223/Ag tapes with applied alternating currents (교류용 Bi-2223/Ag 선재의 안정 통전 조건에 관한 연구)

  • Yim S. W.;Sohn S. H.;Hwang S. D.;Lim S. H.
    • Progress in Superconductivity
    • /
    • v.6 no.2
    • /
    • pp.138-141
    • /
    • 2005
  • Bi-2223/Ag tapes need to be safe, even it is under the over-critical current state for the protection of a superconducting power machine. However, it is not easy to identify the condition for the safe operation because of their broad S/N transition region. In this paper, for the study of the operation condition of Bi-2223/ Ag tapes, we investigated the V-I curves and the temperature variation of Bi-2223/ Ag tapes experimentally, applying alternating over-currents, and analyzed the relationship between resistance and temperature increase. For the experiments, a Bi-2223/Ag tape of 57 A $I_c$ was prepared, and the over-critical current characteristics under adiabatic state from $LN_2$ was measured. From the experiments, we confirmed that the Joule heating predicted by V-I curve corresponded with the increase of the measured temperature exactly. Using the results, a safe operation condition of Bi-2223 tape was discussed.

  • PDF

Measurement of temperature rise over time for commercially available night lights(tea lights) (가정용 촛불의 시간경과에 따른 온도 상승 측정)

  • Gwak, Ji-Hyeon
    • Fire Protection Technology
    • /
    • s.37
    • /
    • pp.32-35
    • /
    • 2004
  • 나이트 라이트 촛불의 사용이 최근 수년간 증가되어 왔으며, 현재 많은 가정집에서 유행중이다. 그 인기의 이유 중 하나는, 침실과 거실이 잘 장식되어 나오는 텔레비전 제작 프로그램의 인기 상승을 포함하여 상대적으로 저렴하고 이용이 쉽기 때문이다. 본 연구는 주위 공기가 무풍일 때와 유속이 있을 때의 나이트 라이트 알루미늄 케이스의 온도 상승을 단일 촛불 심지와 이중 심지에 대해 조사한다. 보통 이중 심지의 경우 온도상승이 빨랐으며, 쉽게 200 이상에 도달하였다.

  • PDF

Study of Cresol-Novolac Epoxy Systems on Fusion Bonded Epoxy Coatings for Pipeline Protection

  • Chung, Chi Wook;Lee, Sang Sun;Chai, Soo Gyum;Lim, Jong Chan
    • Corrosion Science and Technology
    • /
    • v.2 no.4
    • /
    • pp.202-206
    • /
    • 2003
  • Fusion Bonded Epoxy(FBE) systems have been widely used to protect pipelines for over 30 years. Numerous attempts have so far been made to improve the properties of FBE coatings such as chemical resistance, adhesion, water resistance, cathodic disbondment resistance, impact resistance, and flexibility to protect pipelines at a wet and a high temperature condition. But these attempts have not been successful in reducing some weakness, for instance, in pipeline operating at high temperature due to poor hot water resistance and cathodic protection. The purpose here is to build a basis for getting better corrosion resistance of FBE systems. Cresol-novolac epoxy coating systems were studied compared to bisphenol A type epoxy systems. After the immersion of the film in water at a high temperature for a long period, good adhesion to metal substrate and excellent cathodic disbond resistance were observed in the cresol-novolac epoxy resin systems. It is well known that the adhesion of organic coatings to metal substrate might be decreased due to the disruption of a chemical bond across the film and metal interface induced by water molecules. A high crosslinking density might decrease water permeability and improve cathodic disbonding protection in the coatings. Other factors are studied to understand anti-corrosion mechanism of Cresol-novolac epoxy coatings. In addition, the water absorption rate and the effect of cure temperature on the adhesion and cathodic disbonding resistance ofthe films were studied in different epoxy coatings and the effect of substrate was evaluated. The results of field application are proved that the Cresol-novolac epoxy coating system developed recently is one of the most suitable coatings for protection of pipelines.

Study on the Explosion and Fire Risks of Lithium Batteries Due to High Temperature and Short Circuit Current (고온 및 단락전류에 따른 리튬배터리의 폭발 및 화재 위험성에 관한 연구)

  • Sim, Sang-Bo;Lee, Chun-Ha;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.114-122
    • /
    • 2016
  • This study is to analyze the explosion and fire risks due to high temperature and short circuit current of Lithium batteries. This study selected the typical types of Li-polymer batteries and Li-ion batteries as the test samples. The result of explosion risk assessment due to the high temperature showed that, while a Li-polymer battery had $170^{\circ}C$ explosion on average, a Li-ion battery had $187^{\circ}C$ explosion. The measurement result of temperature increase due to short circuit current revealed that, in case that protection circuit module (PCM) was normally working, there was little of temperature increase due to over-current limitation. However, in case that PCM was out of order, the temperature of a Li-polymer battery increased up to an average of $115.7^{\circ}C$ and the temperature of a Li-ion battery increased up to an average of $80.5^{\circ}C$, which showed the higher risks of fire and burn.

Design of Gate Driver Chip for Ionizer Modules with Fault Detection Function (Fault Detection 기능을 갖는 이오나이저 모듈용 게이트 구동 칩 설계)

  • Jin, Hongzhou;Ha, PanBong;Kim, YoungHee
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.132-139
    • /
    • 2020
  • The ionizer module used in this air cleaner supplies high voltages of 3.5KV / -4KV to the discharge electrode HV+ / HV- using a winding transformer to generate positive and negative ions by electric field radiation of carbon fiber brush. The ionizer module circuit using the existing MCU has the disadvantage of large PCB size and expensive price, and the gate driver chip using the existing ring oscillator has oscillation period sensitive to PVT (Process-Voltage-Temperature) fluctuation and there is risk of fire or electric shock because there is no fault detection function by short circuit of HV+ and GND as well as HV- and GND. Therefore, in this paper, even though PVT fluctuates, by using 7-bit binary up counter, HV+ voltage reaches the target voltage by adjusting oscillation period. And an HV+ short fault detection circuit for detecting a short circuit between HV+ and GND, an HV- short fault detection circuit for detecting a short circuit between HV- and GND, and an OVP (Over-Voltage Protection) for detecting that HV+ rises above an overvoltage are newly proposed.

The coupling field analysis of a thermal transfer phenomenon by an magnetic field (자계 분포시 열유동 현상 분석을 통한 결합계 해석)

  • Son, Rak-Won;Jang, Kwang-Yong;Bae, Jae-Nam;Kim, Sung-Ju;Choi, Sung-Gil;Ju, Lee
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.862-863
    • /
    • 2007
  • In this article, we researched the characteristics of heat transfer of the bimetal for over-current protection device. Bimetal consists of two metals which have a different thermal expansion coefficient. To analyze the heat transfer characteristics, by using a bimetal which has a single metal, we analyzed the temperature distribution when bimetal acts a switch. As usual, heat source is applied to the bimetal. But, in the over-current protection switch, the current become heat source. So, by using the current as source, we performed the magnetic analysis and thermal analysis together.

  • PDF