• 제목/요약/키워드: Output unit

검색결과 968건 처리시간 0.025초

Verification of an Autonomous Decentralized UPS System with Fast Transient Response Using a FPGA-Based Hardware Controller

  • Yokoyama, Tomoki;Doi, Nobuaki;Ishioka, Toshiya
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.507-515
    • /
    • 2009
  • This paper proposes an autonomous decentralized control for a parallel connected uninterruptible power supply (UPS) system based on a fast power detection method using a FPGA based hardware controller for a single phase system. Each UPS unit detects only its output voltage and current without communications signal exchange and a quasi dq transformation method is applied to detect the phase and amplitude of the output voltage and the output current for the single phase system. Fast power detection can be achieved based on a quasi dq transformation, which results in a realization of very fast transient response under rapid load change. In the proposed method, the entire control system is implemented in one FPGA chip. Complicated calculations are assigned to hardware calculation logic, and the parallel processing circuit makes it possible to realize minimized calculation time. Also, an Nios II CPU core is implemented in the same FPGA chip, and the software can be applied for non-time critical calculations. Applying this control system, an autonomous decentralized UPS system with very fast transient response is realized. Feasibility and stable operation are confirmed by means of an experimental setup with three UPSs connected in parallel. Also, rapid load change is applied and excellent performance of the system is confirmed in terms of transient response and stability.

산업연관분석법을 이용한 학교 건물에서의 환경영향평가 - 경기지역의 초등학교를 대상으로 - (Environmental Impact Assessment at a School Building using Input-output Table - Focused on Elementary School in Gyeonggi-do -)

  • 최두성;전흥찬;조균형
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.57-62
    • /
    • 2016
  • Purpose: A lot of active researches have addressed the impact of a building on global environment, but most of the researches focus on a residential building and a large office building. Hereupon, this study assessed the impact on environment quantitatively through the analysis of input materials targeting a school building. Method:This study calculated embodied energy of input materials suggested in a construction statement on a school building using the input-output analysis. This study finally carried out environmental impact assessment by applying LCIA DB shown in the preceding researches to the calculated embodied energy. Result: The analysis result revealed that the environmental impact per unit area(/$m^2$) at a school building was $4.11E-02PE{\cdot}yr$, among which Construction was found to be $3.59E-02PE{\cdot}yr$, being analyzed to account for about 87% of the total environmental impact. Also, as a result of detailed environmental impact, the impact on global warming among the total environmental impact was analyzed to be high, accounting for about 76%.

고주파 여기식 매트릭스형 도파관 이산화탄소 레이저 (The radio-frequency excited matrix waveguide CO2 laser)

  • 최종운;안명수;이영우
    • 한국광학회지
    • /
    • 제15권4호
    • /
    • pp.343-348
    • /
    • 2004
  • 고주파로 여기 되는 매트릭스형 도파관 이산화탄소 레이저를 개발하였다. 단위길이당 레이저 출력을 증가시키기 위하여 4개의 고주파 방전관을 2 ${\times}$ 2 형태의 매트릭스 구조로 제작하여 한개의 공진기 속에 배치하였다. 레이저 출력은 출력경으로부터 가까운 거리에서는 4개의 독립된 형태로 출력되었고, 출력경으로부터 거리가 멀어질수록 4개의 빔이 하나로 합쳐짐으로서 가우시안 모드에 가까워지는 것을 확인하였다. 레이저에 주입되는 혼합 가스압력이 45 mbar, 가스 혼합비율이 $CO_2$ : $N_2$ : He : Xe = 1 : 1 : 3 : 0.2, 고주파입력 파워가 200 W일 때 약 12 W의 광출력을 얻었다.

A Decade-Bandwidth Distributed Power Amplifier MMIC Using 0.25 μm GaN HEMT Technology

  • Shin, Dong-Hwan;Yom, In-Bok;Kim, Dong-Wook
    • Journal of electromagnetic engineering and science
    • /
    • 제17권4호
    • /
    • pp.178-180
    • /
    • 2017
  • This study presents a 2-20 GHz monolithic distributed power amplifier (DPA) using a $0.25{\mu}m$ AlGaN/GaN on SiC high electron mobility transistor (HEMT) technology. The gate width of the HEMT was selected after considering the input capacitance of the unit cell that guarantees decade bandwidth. To achieve high output power using small transistors, a 12-stage DPA was designed with a non-uniform drain line impedance to provide optimal output power matching. The maximum operating frequency of the proposed DPA is above 20 GHz, which is higher than those of other DPAs manufactured with the same gate-length process. The measured output power and power-added efficiency of the DPA monolithic microwave integrated circuit (MMIC) are 35.3-38.6 dBm and 11.4%-31%, respectively, for 2-20 GHz.

의료서비스산업의 산업연관분석 (Input-Output Analysis on the Medical Service Industry between Korea and Japan)

  • 이견직;정영호
    • 보건행정학회지
    • /
    • 제10권1호
    • /
    • pp.126-147
    • /
    • 2000
  • This paper empirically explores the nature of the medical service industry and its various propagation effects on the economy in the input-output model, as revealed by a comparative analysis between Korea and Japan. The main findings of the paper are as follows; First, the growth of medical industry induces above-average effect on employment. Second, the industry is of the characteristics of weak both backward and forward linkage effects implying a 'final demand dependency industry'. When compared with public service sectors, however, the medical services industry shows stronger backward linkage effect than those sectors. Furthermore, it has strong repercussion effects on the goods industries. Third, in order to produce per unit of services, the medical services industry of Korea uses relatively more drugs and medical devices than that of Japan. In general, it has been shown that production structure of medical service industry in Korea is 'hardware-oriented' one; on the other hand, 'software-oriented' in Japan which means that, as intermediate inputs, outsourcing and informatization has been used than those of Korea. From the findings of the paper it could be emphasized that the medical organizations in Korea should put more efforts on shifting the current hardware-oriented production structure to strengthen core competence by enhancing productivity and by outsourcing to improve efficiency of production process. However, the medical organizations in Korea would not have enough incentives for high value-added production structure because they enjoy high operating surplus. Therefore, it would be necessary that government policy should be taken into account of these environments.

  • PDF

돌극형 회전화 단상 SRM의 쇄교자속 측정 (Measurement of Flux Linkage in Salient Pole Rotor Type Single Phase SRM)

  • 김준호;이은웅;오영웅;이민명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.123-125
    • /
    • 2001
  • Salient pole rotor type single phase SRM(switched reluctance motor) uses the magnetic fluxes of radial and axial direction at the same time. Therefore the output power per unit volumn is very high and shaft length can be shorter than any other types of SRM with same output. Also, It can be manufactured with low cost thanks to simple structure and driving circuit. We already designed and manufactured prototype using the dynamic output equation of general rotating machine but the effect by salient pole structure was not considered. The most optimal design parameters for salient pole rotor type single phase SRM will be selected by comparing and analyzing the results from 3D FEM analysis, experimental values of the torque versus speed characteristics. and the nux linkage of prototype. Results for the former 3D FEM analysis and torque vs. speed characteristics were already obtained. Finally, we will measure the nux linkage of salient pole rotor type single phase SRM.

  • PDF

Assessment and Implications of Maximizing the Capacities in Social and Physical Infrastructure in Middle-Income Asian countries

  • YASMIN, Fouzia;SAFDAR, Noreen;KHATOON, Sabila;ALI, Fatima
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권12호
    • /
    • pp.85-94
    • /
    • 2021
  • Infrastructure capacities are essential elements and one of the sustainable lines to drive economic growth. Infrastructure development, both physical and social, is vital to sector-wise economic development. However, there is limited evidence of how infrastructure development in certain sectors benefits the economy as a whole. This study explains the relationships between infrastructure and economic growth in selected middle-income Asian countries, highlighting the essential criteria to benefit from both physical and social infrastructure, as well as sectoral (agriculture, industry, and services) economic output. The research uses the data from 1990 to 2020 for empirical estimations. The study used Levin, Lin, & Chu test, ADF- Fischer chi- Square, and PP- Fischer Chi-Square to test unit root and to observe the stationary nature of the panel. Padroni and Kao cointegration is applied to check the cointegration among different panes. A Fully Modified OLS was employed for checking the association between physical and social infrastructure and economic growth. Results show that physical and social infrastructure negatively impact sectoral output in Asia's middle-income countries. Apart from infrastructure the per capita GDP growth, tax to GDP ratio, and population growth shows a simultaneous relation between infrastructure and sectoral economic growth.

Unbalance Control Strategy of Boost Type Three-Phase to Single-Phase Matrix Converters Based on Lyapunov Function

  • Xu, Yu-xiang;Ge, Hong-juan;Guo, Hai
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.89-98
    • /
    • 2019
  • This paper analyzes the input side performance of a conventional three-phase to single-phase matrix converter (3-1MC). It also presents the input-side waveform quality under this topology. The suppression of low-frequency input current harmonics is studied using the 3-1MC plus capacitance compensation unit. The constraint between the modulation function of the output and compensation sides is analyzed, and the relations among the voltage utilization ratio and the output compensation capacitance, filter capacitors and other system parameters are deduced. For a 3-1MC without large-capacity energy storage, the system performance is susceptible to input voltage imbalance. This paper decouples the inner current of the 3-1MC using a Lyapunov function in the input positive and negative sequence bi-coordinate axes. Meanwhile, the outer loop adopts a voltage-weighted synthesis of the output and compensation sides as a cascade of control objects. Experiments show that this strategy suppresses the low-frequency input current harmonics caused by input voltage imbalance, and ensures that the system maintains good static and dynamic performances under input-unbalanced conditions. At the same time, the parameter selection and debugging methods are simple.

시변 변환 행렬을 이용한 시간에 안정된 RGB LED Backlighting 구동 전류 제어 (Driving Current Control for Time-Stable RGB LED Backlighting Using Time-Varying Transform Matrix)

  • 박기현;하영호
    • 대한전자공학회논문지SP
    • /
    • 제46권4호
    • /
    • pp.42-49
    • /
    • 2009
  • 본 논문에서는 red, green, blue(RGB) 광학 센서를 이용하여 RGB light-emitting diode(LED) back light unit(BLU)의 출력색 자극의 변화를 점검하여 RGB LED BLU가 시간에 따라 일정한 목표 색 자극을 출력할 수 있도록 하는 RGB LED BLU 구동 전류 펄스 duty 값을 도출하는 알고리즘을 제안한다. 우선, 현재 RGB LED BLU가 발하는 색 자극 정보를 획득하기 위해 RGB 광학 센서의 출력으로부터 CIEXYZ 색 자극을 계산할 수 있는 RGB to XYZ 변환 행렬을 도출한다. 다양한 RGB LED BLU 색 자극 샘플에 대한 RGB 광학 센서의 출력 값과 CIEXYZ 색 자극 값의 쌍을 이용하여 다항 회귀 방정식을 만들고 각 항의 계수로 행렬을 구성한다. 다음으로, 현재 RGB LED BLU 상태에서 목표 색 자극 값을 발할 수 있는 duty 값을 구하기 위해 목표 색 자극으로부터 duty 값을 계산할 수 있는 XYZ to Duty 변환 행렬을 도출한다. 현재, 한 단계 이전, 두 단계 이전 시점에서 RGB 광학 센서의 출력으로부터 추정한 CIEXYZ 값과 그때 인가된 duty 값의 쌍을 이용하여 다항 회귀 방정식을 만들고 각 항의 계수로 행렬을 구성한다. 일정 시간 간격으로 RGB LED BLU의 출력 색 자극을 점검할 때마다 XYZ to Duty 변환 행렬은 RGB LED BLU의 현재 상태에 적응적으로 변하게 되어 목표 색 자극을 출력할 수 있는 duty 값을 계산할 수 있게 된다.

PFM/PWM 듀얼 모드 피드백 기반 LED BLU 구동용 LLC 공진 변환 제어 IC 설계 (A Design of PFM/PWM Dual Mode Feedback Based LLC Resonant Converter Controller IC for LED BLU)

  • 유창재;김홍진;박영준;이강윤
    • 전기전자학회논문지
    • /
    • 제17권3호
    • /
    • pp.267-274
    • /
    • 2013
  • 본 논문은 Pulse Frequency Modulation(PFM)/Pulse Width Modulation(PWM) 듀얼 모드 피드백 기반 LED 백라이트 유닛 구동용 LLC 공진 변환 제어 IC 설계에 대한 내용을 제시한다. 공진형 변환기에서 하나의 변압기를 사용하면서, 두 가지 출력 전압을 생성할 수 있는 구조를 제안하였으며, Master 출력은 PFM 방식으로 Slave 출력은 PWM 방식으로 제어하도록 설계 하였다. 2차 측 Master 출력을 제어하기 위해서 파워 스위치 제어 신호의 주파수를 조절하는 PFM 피드백과 2차 측 Slave 출력을 제어하기 위해서 파워 스위치 제어 신호의 펄스 폭을 조절하는 PWM 피드백 회로를 설계하였다. 설계된 IC는 $0.35{\mu}m$ 2 Poly 3 Metal BCD(Bipolar-CMOS-DMOS) 공정을 이용하여 레이아웃 되었으며, 면적은 $2.3mm{\times}2.2mm$ 이다. 또한, 설계한 칩은 5 V 공급 전압으로부터 26 mA의 전류를 소모하였다.