• Title/Summary/Keyword: Output unit

Search Result 968, Processing Time 0.028 seconds

Power Supply for Induction Heating using High Frequency Twin Resonant Inverter (TWIN RESONANT 방식을 이용한 고주파 공진형 유도가열 전원장치)

  • Kwon, Soon-Kurl;Park, Gil-Tae;Kim, Yo-Hee;Jeo, Ki-Yeon;Yoo, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1108-1113
    • /
    • 1992
  • In this paper, the high frequency twin resonant inverter using MOSFET is presented. The output control is excellent and the EMI noise is reduced, because the output appear as the vector sum of current in each unit inverter. The output voltage and the output current of the inverter are controlled by PLL. In this paper, the principle of the twin resonant method is described. And computer simulations and experimental results are shown.

  • PDF

A Study on configuration of a laser resonator with high alignment stability (높은 정렬 안정성을 갖는 레이저 공진기 구성에 관한 연구)

  • 차혁진
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.279-288
    • /
    • 2000
  • The variations of output energy due to tilt output coupler for different types of pulsed Nd:YAG laser resonators were compared by measuring FWHM (full width at half maximum) which means the width of angle displacement where maximum output energy decreases to half value. We proposed a new configuration of pulsed solid-state laser resonator which had high FWHM for tilting of output coupler and which was little sensitive for tilting of rear optics. We proved that our laser resonator had high alignment stability using ABeD ray matrix method because the ray matrix of such a resonator corresponded to unit matrix. atrix.

  • PDF

Position Control of Chained Multiple Mass-Spring-Damper Systems - Adaptive Output Feedback Control Approaches

  • S. S. Ge;L. Huang;Lee, T. H.
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.2
    • /
    • pp.144-155
    • /
    • 2004
  • This paper addresses the issue of position control of a chain of multiple mass-spring-damper (CMMSD) units which can be found in many physical systems. The dynamic model of a CMMSD system with any degrees of freedom is expressed in a closed-form for the convenience of the controller design. Backstepping and model reference adaptive control (MRAC) approaches are then used to develop two adaptive output feedback controllers to control the position of a CMMSD system. The proposed controllers rely on the measurements of the input (force) and the output (position of the mass unit at the end of the chain) of the system without the knowledge of its parameters and internal states. Simulations are used to verify the effectiveness of the controllers

Development of a Multiple SMPS System Controlling Variable Load Based on Wireless Network

  • Ko, Junho;Park, Chul-Won;Kim, Yoon Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1221-1226
    • /
    • 2015
  • This paper proposes a multiple switch mode power supply (SMPS) system based on the wireless network which controls variable load. The system enables power supply of up to 600W using 200W SMPS as a unit module and provides a controlling function of output power based on variable load and a monitoring function based on wireless network. The controlling function for output power measures the variation of output power and facilitates efficient power supply by controlling output power based on the measured variation value. The monitoring function guarantees a stable power supply by observing the multiple SMPS system in real time via wireless network. The performance of the proposed system was examined by various experiments. In addition, it was verified through standardized test of Korea Testing Certification. The results were given and discussed.

THE CHARACTERISTICS OF OUTPUT FOR INVERTER TYPE X-RAY GENERATOR

  • Lim, Hong-Woo;Han, Euam-Yong;Baek, Hyung-Lae;Lee, Seong-Kil
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.431-435
    • /
    • 1998
  • This paper deals with the output characteristics of resonant PWM inverter type X-ray generators connected to different DC power units i.e. a single phase full bridge rectifier, a three phase full bridge rectifier and a power storage unit(PSU). The quality of X-ray beam depend on the pulsation waveforms of DC voltage supplied to the X-ray tulbe. In a X-ray generator, the waveforme of DC output voltage can be affected from hramonic distortion of DC input power. When a tube voltage waveform is distorded, the property of X-ray beam such as reproducibility, direcibility and doesage can be reduced. Therefore, we compared DC output waveforms and doesages with three thpe of DC power units and show the experimental results in this paper

  • PDF

Development of a 0.5MW PCS for efficient connection operation of wind power system (풍력 발전시스템의 효율적인 연계운전을 위한 0.5MW급 PCS 개발)

  • Lee, Yun-Jae;Choi, Eun-Sik;Lee, Chung-Woo;Ryu, Kang-Yeul;Jo, Jang-Ho;Lee, Jin
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.498-500
    • /
    • 2012
  • According to the climatic characteristics of the wind power output is difficult to predict and a severe strain due to a change in output has been very influential in the grid. Jeju Hangwon wind farm, many of the wind generator is installed in a wide area because it is not have this device that artificially Smoothing is needed. In addition, By the requirements of the power company active power supply / control and improve power system reliability and energy storage during the peak demand for electricity using the energy stored in the power supply is needed. In this paper, Unit 12 in Jeju Hangwon demonstrated 0.5MW PCS and energy storage system associated with the wind through the stabilization of output and the leveling of output and test results will be introduced.

  • PDF

A novel resonant pulse control in resonant DC link inverter (공진형 직류 링크 인버터의 공진 펄스 제어기)

  • 유동욱;원충연
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.5
    • /
    • pp.152-158
    • /
    • 1996
  • A novel resonant pulse control technique which generates high-quality sinusoidal output voltage from a resonant dc link inverter is presented for UPS applicatons. The proposed control technique limits resonant voltae overshoot without any passive or active clamp circuit, resulting in resonant pulses iwth uniform amplitude and high efficiency. The output voltage is controlled by the third order contorller iwth an inner loop of th efilter inductor current and the feedforward controller. Analysis and design of the proposed control technique are illustrated and verified on a 5kVA experimental unit.

  • PDF

A Study on Bypass Characteristics for Photovoltaic Module (태양광모듈 바이패스 특성에 관한 연구)

  • Chae, Myoung-Suk;Suh, Hun-Young
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.79-80
    • /
    • 2014
  • In this paper, to make sure that the photovoltaic solar cell module of the system can be normal for output in each solar cell module, input and output unit is installed in the bypass device, and then through the voltage and current monitoring to determine abnormality of the solar cell module, in the case of abnormal occurring, the bypass device can be pass to the next solar module of the serial structure.

  • PDF

Thermodynamic Analysis of Power Generation Cycle Utilizing LNG (LNG 냉열이용 동력사이클 해석)

  • 최권일;장호명
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.165-168
    • /
    • 1999
  • Thermodynamic cycle analysis has been performed for the power generation systems to utilize the cold energy of liquefied natural gas (LNG). Among many possible configurations of the cycle, the open Rankine cycle, the closed Rankine cycle, and the closed Brayton cycle are selecte for the analysis because of their practical importance. The power output per unit mass of LNG has been analytically calculated for various design parameters. The optimal conditions for the parameters to maximize the power output are presented and some of the design considerations are discussed.

  • PDF

Output Filter Design of Voltage Source Inverter for CVCF System (CVCF용 VSI의 출력필터 설계)

  • 김재식;최재호
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.287-290
    • /
    • 1999
  • This paper describes an optimal design method of VSI output filter for CVCF system. The cost function is used for design, and all parameters are described in p.u(per unit) so that can be adapted to the change of CVCF rating. The capacitor current feedback scheme is proposed to control the damping ratio of the filter plant to meet the system more stable. This means that the LC resonance can be suppressed well in transient condition and can use the same control gains under the change of system capacity. The validity of the proposed method is well verified with the theoretical analysis and simulation results.

  • PDF