• Title/Summary/Keyword: Output response

Search Result 1,399, Processing Time 0.025 seconds

Output LC Filter Design for UPS Inverter Considering the Response of System (시스템 응답을 고려한 UPS 인버터의 출력 LC필터 설계)

  • Kim, Jae-Sig;Lee, Sang-Hoon;Choi, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.7
    • /
    • pp.347-355
    • /
    • 2001
  • The conventional output filter design methods of a voltage source inverter includes two main problems: the performance is not sure to satisfy the specification under the nonlinear load; the designed filter must be occasionally modified when the controller is designed. In this paper, we analyze the relation between both linear and nonlinear loads, the output voltage magnitude, LC lowpass filter parameters, and the control response time. Upon the basis, both filter and controller are simultaneously designed for the performance to satisfy the specification under the nonlinear load as well as linear load. The proposed method sharply enhances the reliability of the performance. P.U is used for the method to be applied to all the quantities of the system. The simulation and the experiment of the proposed method carried out respectively to verify the validity.

  • PDF

Soft-Switching Auxiliary Current Control for Improving Load Transient Response of Buck Converter

  • Kim, Doogwook;Shin, Joonho;Shin, Jong-Won
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.160-162
    • /
    • 2020
  • A control technique for the auxiliary buck/boost converter is proposed herein to improve the load transient response of the buck converter. The proposed technique improves the system efficiency by enabling the soft switching operation of the auxiliary converter. The design guidelines for achieving capacitor charge balance for the output capacitor during the transient are also presented herein. The experimental results revealed that the output voltage undershoot and settling time during the load step-up transient were 40 mV and 14 ㎲, respectively, and the output voltage overshoot and settling time during the load step-down transient were 35 mV and 21 ㎲, respectively. The performance and effectiveness of the proposed technique were experimentally verified using a prototype buck converter with a 15-V input, 3.3-V output, and 200-kHz switching frequency.

  • PDF

Monetary Policy Transmission during Multiple Indicator Regime: A Case of India

  • SETHI, Madhvi;BABY, Saina;DAR, Vandita
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.6 no.3
    • /
    • pp.103-113
    • /
    • 2019
  • The effectiveness of monetary policy critically depends upon how well the transmission mechanism functions, so that the desired impact on output and inflation is achieved. The purpose of this paper is to study the transmission mechanism of monetary policy by analyzing the impact on inflation and output during multiple indicator regime (1998-99 to 2014) in an emerging economy-India. The Inflation Targeting Regime is also briefly outlined alongwith the impact on output and inflation. Using quarterly data for the period 1997 to 2017, the paper uses weighted average call money market rate as a proxy for the policy rate and evaluates the strength of the interest rate channel. We use a conventional Structural vector auto regression (SVAR) methodology to evaluate the efficacy and show the impluse response functions. Our results find that changes in the policy rate impact output growth steeply with a lag of about two quarters and the impact on inflation is maximized after three quarters. The study concludes that the monetary policy in India has a significant impact on output and inflation in the short-to-medium-run. After the policy shock, the fall in the output growth rate is of greater magnitude than the fall in inflation.

Verification of an Autonomous Decentralized UPS System with Fast Transient Response Using a FPGA-Based Hardware Controller

  • Yokoyama, Tomoki;Doi, Nobuaki;Ishioka, Toshiya
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.507-515
    • /
    • 2009
  • This paper proposes an autonomous decentralized control for a parallel connected uninterruptible power supply (UPS) system based on a fast power detection method using a FPGA based hardware controller for a single phase system. Each UPS unit detects only its output voltage and current without communications signal exchange and a quasi dq transformation method is applied to detect the phase and amplitude of the output voltage and the output current for the single phase system. Fast power detection can be achieved based on a quasi dq transformation, which results in a realization of very fast transient response under rapid load change. In the proposed method, the entire control system is implemented in one FPGA chip. Complicated calculations are assigned to hardware calculation logic, and the parallel processing circuit makes it possible to realize minimized calculation time. Also, an Nios II CPU core is implemented in the same FPGA chip, and the software can be applied for non-time critical calculations. Applying this control system, an autonomous decentralized UPS system with very fast transient response is realized. Feasibility and stable operation are confirmed by means of an experimental setup with three UPSs connected in parallel. Also, rapid load change is applied and excellent performance of the system is confirmed in terms of transient response and stability.

THEORY OF BACKGROUND NOISE CANCELLATION ON PREDICTION OF RESPONSE PROBABILITY DISTRIBUTION FOR AN ARBITRARY SOUND WALL SYSTEM AND ITS APPLICATION TO ACTUAL SOUND WALL SYSTEMS

  • Ohta, M.;Takaki, N.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.740-745
    • /
    • 1994
  • In the actual situation of measuring the environmental noise, it is very often that only the resultant phenomenon fluctuation contaminated by the additional noise of arbitrary distribution type can be observed. Furthermore, the observed data is usually given in a sound level form the purpose of estimating only the undisturbed objective output response, some estimation method is necessary to reasonably remove the effect of the above additional noise. In this paper, first, a mathematical model of arbitrary sound insulation systems is introduced in the form of a linear system on intensity scale, by using the well-known additive property of energy quantities. Next, some estimation method of the output response under the existence of background noise is derived. Then, based on the expression of the above estimation method, a new prediction method of only the output response probability function form for arbitrary sound insulation systems without. a background noise is proposed by use of observed data contaminated by a background noise. Finally, the effectiveness of the proposed method is confirmed experimentally too by applying it to the actual various type sound wall systems.

  • PDF

Design of Fuzzy-PI Controllers for the Gas Turbine System (가스터빈 시스템을 위한 퍼지-PI 제어기의 설계)

  • Kim, Jong-Wook;Kim, Snag-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.11
    • /
    • pp.1013-1021
    • /
    • 2000
  • This paper suggests fuzzy-PI controllers for a heavy-duty gas turbine. The fuzzy-PI controllers are designed to regulate rotor speed and exhaust temperature of the gas turbine. The controller gains are tuned by genetic algorithm(GA). This paper also proposes a new fitness function of GA using a desired output response. The suggested controller is compared with previous controllers via simulations and it is shown that the rotor speed variation of our controller is smaller than those of previous ones.

  • PDF

Predictive Control of Structural Vibration Subject to Wind Loads (풍하중에 대한 구조진동의 예측제어)

  • 최창근;권대건;이은진
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.10a
    • /
    • pp.29-36
    • /
    • 1996
  • A procedure for the predictive control for structural vibration control in building subject to wind loads is presented. The building motions are modeled by the first mode of the response. Wind velocities are generated by the simulation using power spectral density function. Predictive control algorithm is the discrete-time formulation and that is developed as a control strategy that computes the control signal which makes the predicted process output equal to a desired process output. Results on the reduction of the dynamic response and control effectiveness of the algorithm are presented and discussed.

  • PDF

Gust Response Analysis and Alleviation Method for Aircraft Wing (항공기 날개 돌풍 응답해석 및 완화기법)

  • 이상욱;김태욱;황인희;하철근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.452-456
    • /
    • 2004
  • A study on gust loads alleviation using aircraft control surface was performed. Aeroservoelastic model including control surface controller was formulated and validated by comparing the results of continuous turbulence response analysis with those of MSC/NASTRAN. Optimal control with output feedback was adopted for designing the control surface controller, and the effects of gust loads alleviation was validated by performing the numerical simulation for the controller designed.

  • PDF

Response of an Elastic Pendulum under Random Excitations (불규칙 가진을 받는 탄성진자의 응답 해석)

  • Lee, Sin-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.18 no.2
    • /
    • pp.187-193
    • /
    • 2009
  • Dynamic response of an elastic pendulum system under random excitations was studied by using the Lagrangian equations of motion which uses the kinetic and potential energy of a target system. The responses of random excitations were calculated by using Monte Carl simulation which uses the series of random numbers. The procedure of Monte Carlo simulation is generation of random numbers, system model, system output, and statistical management of output. When the levels of random excitations were changed, the expected responses of the pendulum system showed various responses.

A Case Study for Finding an Efficient M&S Meta Model through Sequential Response Surface Methodology (축차적 반응표면 분석을 통한 M&S 메타모형 구축에 관한 사례 연구)

  • Kim, Sang-Ik;Kim, Yong-Dai;Lim, Yong-Bin;Choi, Ki-Heon;Kim, Jeong-Eun
    • Journal of Korean Society for Quality Management
    • /
    • v.40 no.1
    • /
    • pp.49-59
    • /
    • 2012
  • In computer simulation models the output from the computer code is often deterministic, i.e., running the code twice with the same values for the input variables would give the same output. It is discussed why the response surface method with polynomial approximation for the true response function is a good approximation to the computer experiments model. A sequential strategy to find the proper reduced quadratic polynomial model is illustrated with a case study in the military war game computer simulation model.