• Title/Summary/Keyword: Output measurement

Search Result 1,462, Processing Time 0.023 seconds

Diminution of Current Measurement Error in Vector Controlled AC Motor Drives

  • Jung Han-Su;Kim Jang-Mok;Kim Cheul-U;Choi Cheol;Jung Tae-Uk
    • Journal of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.151-159
    • /
    • 2005
  • The errors generated from current measurement paths are inevitable, and they can be divided into two categories: offset error and scaling error. The current data including these errors cause periodic speed ripples which are one and two times the stator electrical frequency respectively. Since these undesirable ripples bring about harmful influences to motor driving systems, a compensation algorithm must be introduced to the control algorithm of the motor drive. In this paper, a new compensation algorithm is proposed. The signal of the integrator output of the d-axis current regulator is chosen and processed to compensate for the current measurement errors. Usually the d-axis current command is zero or constant to acquire the maximum torque or unity power factor in the ac drive system, and the output of the d-axis current regulator is nearly zero or constant as well. If the stator currents include the offset and scaling errors, the respective motor speed produces a ripple related to one and two times the stator electrical frequency, and the signal of the integrator output of the d-axis current regulator also produces the ripple as the motor speed does. The compensation of the current measurement errors is easily implemented to smooth the signal of the integrator output of the d-axis current regulator by subtracting the DC offset value or rescaling the gain of the hall sensor. Therefore, the proposed algorithm has several features: the robustness in the variation of the mechanical parameters, the application of the steady and transient state, the ease of implementation, and less computation time. The MATLAB simulation and experimental results are shown in order to verify the validity of the proposed current compensating algorithm.

Study on the Dose Characteristics of the PTW-LinaCheck Dosimeter and Its Application to Daily Output Measurement (PTW-LinaCheck 측정기의 선량 특성과 일일 출력측정 응용에 관한 연구)

  • Jeong, Dong-Hyeok;Lee, Kang-Kyoo;Moon, Un-Chul;Kim, Hyun-Jin;Kim, Young-Seok;Moon, Sun-Rock
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.56-62
    • /
    • 2008
  • In this study, we have investigated the dose characteristics of PTW-LinaCheck designed to detect output of medical LINAC and discussed clinical use of the detector. The reproducibility, linearity, and dose rate dependency of the dosimeter were measured for photons of 6 and 15MV and the electrons of 4, 6, 9, 12, and 16MeV. To know the error ranges of the measured data in daily output measurement, the response variations due to geometrical setup errors were measured. As a result of measurement, the error range from the geometrical setup and the reproducibility was less than ${\pm}0.6%$ for given beam qualities in daily output measurement, where the errors from the linearity and the dose rate dependency were negligible. Finally, we concluded that the LinaCheck dosimeter has a good characteristics in terms of dose and setup convenience in daily output measurement. In addition we have shown an examples of clinical use of this dosimeter for measuring daily output more than 60 days.

  • PDF

Measurement Technology of the Dissolved Hydrogen Gas Due to Partial Discharge in Oil using Gas Sensor (가스센서를 이용한 부분방전특성에 따른 유중수소가스 측정연구)

  • Heo, Jong-Cheol;Sun, Jong-Ho;Kang, Dong-Sik;Jeong, Joo-Young;Choo, Y.B.;Park, Jung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1784-1789
    • /
    • 2009
  • This paper describes the measurement technology of the dissolved hydrogen gas due to partial discharge in oil using gas sensor. For higher resolution and less error in measurement of the dissolved hydrogen gas in oil, the sensor outputs with ambient temperature which affect the sensor output characteristics should be considered. The sensor output trends with ambient temperature and the properties of the dissolved hydrogen gas in oil with partial discharge characteristic were analyzed through the test results. It was indicated that the sensor peak and the base voltage with measuring time were affected by ambient temperature and the measurement errors of the sensor output by temperature were reduced by using the difference between the peak and the base voltage rather than just the peak voltage. In addition, the hydrogen gas sensor outputs were increased with the increase of partial discharge energy.

The Study of Characteristics Evaluation for Bimorph PZT Cantilever and its Application (바이몰프 PZT 캔틸레버 특성평가 및 응용연구)

  • 김석삼;채영훈;권현규
    • Tribology and Lubricants
    • /
    • v.19 no.3
    • /
    • pp.133-138
    • /
    • 2003
  • The characteristics for bimorph PZT cantilever of laboratory-fabricated have been evaluated experimentally. The deflections of cantilever with PZT are result from a capillary force between a water drop and a tip of cantilever. The output voltage due to deflect cantilever are depend on the tip shape and thickness of cantilever. We applied a bimorph PZT cantilever to oil thickness measurement. This reasonable concept is that the output voltage be caused by different defected characteristics between oil and surface. Experimental results demonstrated that the high measurement accuracy of the oil film thickness is obtained from the probe.

Reduction of Minimum Switching Duration in the Measurement of Three Phase Current with DC-Link Current Sensor (DC링크 전류센서를 이용한 삼상전류 측정 방식에서 최소 스위칭 시간의 단축)

  • 김경서
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.649-654
    • /
    • 2003
  • The simplest method for measuring output currents of the three phase inverters is to measure them with three current sensors such as hall sensors. This method requires at least two current sensors, and these types of sensors are somewhat expensive. More economical method is measuring DC link current with a simple shunt resistor, then, reconstructing output current using the DC link current value and the switching status. However, in low speed region, the measurement becomes difficult and even impossible due to the requirement of minimum switching duration for A/D conversion. These problems can be overcome by limitation of switching duration. Limitation of switching, however, causes voltage and current distortion. Owing to compensation, distortion can be effectively suppressed. However these increase acoustic noise due to increment of current ripple. In this paper, a current measurement method is proposed, which can reduce minimum switching duration resulting in reduction of acoustic noise. The validity of proposed method is confirmed through experiment.

An Aalternating Motion Measurement Technique Using Linear Variables Differential Transformers (선형변이 차동변압기를 이용한 왕복운동 계측기법)

  • Choi, Ju-Ho;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.5
    • /
    • pp.455-460
    • /
    • 1997
  • This paper presents a recoil and counter recoil motion measurement method using linear variable differential transformers(LVDT). The output of a LVDT is obtained from the differential voltage of the 2nd transformers. As the sensor core is attached to the motion body, the output is directly proportional to the core motion. Displacement, velocity and acceleration are measured from the core length. A comparison between the measurement result and the known value, which is obtained by the precision steel tape, shows that the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

A Study of the Real-time Sensing by the Optical Current Sensor for GIS

  • Park, Won-Zoo;Kim, Yeong-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.75-80
    • /
    • 2009
  • In this study, a Web server was constructed using LabVIEW's DataSocket, which makes possible acquisition, analysis, and saving in real time. The output value of the optical current sensor at the web server PC was measured and the output value was displayed using the Web browser of the client PC. DataSocket by LabVIEW makes the construction of a Web server easier than other languages and is compatible with other application programs. An optical current sensor was composed using a 1310 [nm] laser diode, and 9/125 [${\mu}m$] standard single mode optical fiber and was created to be a close type sensor. Data measurement using Web servers has the advantage of monitoring electric power systems at a great distance and can fuse IT technology and electric power systems. Also, this measurement uses inexpensive mounting and programming when compared to existing measurement equipment allowing the construction of a measurement system in any situation or surrounding.

The Estimation on Switching Technique via Output Power Source Analysis of Power Conversion System in an Electric Railway Vehicle (철도차량내의 전력변환장치 출력전원 분석을 통한 스위칭 기법 추정)

  • Kim, Jae-Moon;Lee, Eul-Jae;Yun, Cha-Jung;Kim, Yang-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.185-190
    • /
    • 2010
  • This paper presents the estimation on switching technique via output power source analysis of power conversion unit in electric railway vehicle. The focus of this study suggested an alternative on critical problems by using head electric power(HEP). To achieve this, we have measured output power of HEP, and measurement devices set up at output of transformer connected HEP to analysis quality on output power source of head electric power(HEP) unit in electric railway vehicle. Using results of measurement of it, parameters are assumed for simulation to confirm estimation on switching technique. It is confirmed that switching technique is Selected Harmonic Elimination PWM(SHEPWM) and inverter switching frequency is less than 500[Hz]. Throughout experiment and simulation, it is estimated that switching technique used HEP is advanced SHEPWM and switching frequency is about 300[Hz]. Also leakage inductance in transformer is about $180[{\mu}H]$ less than $365[{\mu}H]$ known.

The Acoustic Output Estimation for Therapeutic Ultrasound Equipment using Electro-Acoustic Radiation Conductance (전기-음향 방사컨덕턴스를 이용한 치료용 초음파 자극기의 음향출력 예측)

  • Yun, Yong-Hyeon;Jho, Moon-Jae;Kim, Yong-Tae;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.264-269
    • /
    • 2011
  • To increase therapeutic efficiency and biological safety, it is important to precision control of acoustic output for therapeutic ultrasound equipment. In this paper, the electro-acoustic radiation conductance, one of electroacoustic characteristics of therapeutic ultrasound equipment, was measured by the radiation force balance method according to IEC 61161 standards and the acoustic output was estimated using the electro-acoustic radiation conductance. The estimation of acoustic output was conducted to continuous wave mode and pulse wave mode of duty cycle between 20% and 80%. The differences between prediction values and measurement results are within 5% of measurement uncertainty, which is a reasonably good agreement. The results show that acoustic output controlled by electro-acoustic radiation conductance was found to be an effective method.

Measurement of Structural Stress Concentration by PVDF Film Sensors (압전필름센서에 의한 구조물의 응력집중의 측정)

  • Kwon, Il-Bum;Kim, Chi-Yeop;Choi, Man-Yong;Lim, Jong-Mook;Kim, In-Gul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.4
    • /
    • pp.109-119
    • /
    • 2000
  • PVDF film sensor was applied to measure the stress concentration for monitoring the structural integrity. The strain calibration of this film sensor was performed by the bending test of aluminum beam. The PVDF sensor and the electrical strain gage were bonded on the beam. When the beam was loaded, the output of electrical strain gage was compared with the output of the PVDF sensor. The waveform of PVDF sensor output was shown as the same form of the output of electrical strain gage. The gain was determined as 1.7 by comparing these two signals to determine the exact value of the strain. In order to experiment the stress concentration, the stress field was analyzed by finite element analysis. The tensile test of notched steel specimens was conducted to develop the measurement technique of stress concentration. The output voltage ratio between the PVDF sensor near the notch and the PVDF sensor far from the notch could give the information about the load bearing capacity of steel specimen.

  • PDF